Loading...
HomeMy WebLinkAboutBELAND- ENERGY CALCFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: BELAND RESIDENCE Builder Name: Street: 7964 PLANTATION LAKES DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, Permit Number: Owner: EDDY AND CONNIE BELAND Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3398.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrER=0.0 3148.70 ft2 b. Frame - Wood, Adjacent R=13.0 250.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (3268.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=22.0 3268.00 ft2 6. Conditioned floor area above grade (ft2) 3268 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(745.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 165 a. U-Factor: Sgl, U=0.69 345.33 ft2 b. Sup: Attic, Ret: Attic, AH: Garage 6 120 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.43 160.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.26 a. Central Unit 42.0 SEER:16.00 b. Central Unit 17.7 SEER:16.00 c. U-Factor: Sgl, U=0.66 72.00 ft2 SHGC: SHGC=0.19 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 168.00 ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 8.343 ft. Area Weighted Average SHGC: 0.226 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (3268.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 3268.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.228 Total Proposed Modified Loads: 109.64 PASS Total Baseline Loads: 109.67 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this l� Code. calculation indicates compliance G'QQ with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 11-5-2020 this building will be inspected for compliance with Section 553.908 ��19E SrAT Q _ tt I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Florida Statutes. C7 ��i,�p� �.�`�•••�` OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT 5UMMAKY CHECKLIST REPORT PROJECT Title: BELAND RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3268 Lot # Owner Name: EDDY AND CONNIE BELAND Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 7964 PLANTATION LA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 2336 26735.2 2 AHU 2 932 10737.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfllID Finished Cooled Heated 1 GREAT RM 492 5904 No 0 1 Yes Yes Yes 2 BATH 4 60 600 No 0 1 Yes Yes Yes 3 OFFICE 271 3252 No 0 1 Yes Yes Yes 4 OFFICE CLST 28 280 No 0 1 Yes Yes Yes 5 BEDROOM 3 222 2220 No 0 1 1 Yes Yes Yes 6 CLST 3 14 140 No 0 1 Yes Yes Yes 7 BATH 2 105 1050 No 0 1 Yes Yes Yes 8 BEDROOM 2 205 2050 No 0 1 1 Yes Yes Yes 9 CLST 2 20 200 No 0 1 No Yes Yes 10 HALL 48 480 No 0 1 No Yes Yes 11 LAUNDRY 100 1000 No 0 1 Yes Yes Yes 12 BATH 3 72 720 No 0 1 No Yes Yes 13 KITCHEN/DINETTE 423 5076 Yes 0 1 Yes Yes Yes 14 DINING RM 144 1915.2 No 0 1 Yes Yes Yes 15 FOYER 132 1848 No 0 1 Yes Yes Yes 16 MASTER BEDROO 403 4836 No 0 1 1 Yes Yes Yes 17 WIC 1 77 770 No 0 1 Yes Yes Yes 18 M BATH 224 2688 No 0 1 Yes Yes Yes 19 WASH RM 42 420 No 0 1 No Yes Yes 20 WIC 2 54 540 No 0 1 No Yes Yes 21 DEN 126 1423.8 No 0 1 Yes Yes Yes 11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 DEN CLST 6 60 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation GREAT RM 29 ft 0 492 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulation BATH 4 14 ft 0 60 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulation OFFICE 36 ft 0 271 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulation OFFICE CLST 2 ft 0 28 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulation BEDROOM 3 18 ft 0 222 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulation CLST 3 2 ft 0 14 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulation BATH 2 7 ft 0 105 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulation BEDROOM 2 15 ft 0 205 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulation CLST 2 1 ft 0 20 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulation HALL 1 ft 0 48 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulation LAUNDRY loft 0 100 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulation BATH 3 1 ft 0 72 ft2 ---- 1 0 0 13SIab-On-Grade Edge Insulation KITCHEN/DINET 14 ft 0 423 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulation DINING RM 12 ft 0 144 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulation FOYER 11 ft 0 132 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulation MASTER BEDRO 38 ft 0 403 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulation WIC 1 11 ft 0 77 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulation M BATH 43 ft 0 224 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulation WASH RM 1 ft 0 42 ft2 ---- 1 0 0 20SIab-On-Grade Edge Insulation WIC 2 1 ft 0 54 ft2 ---- 1 0 0 21SIab-On-Grade Edge Insulation DEN 11 ft 0 126 ft2 ---- 1 0 0 22SIab-On-Grade Edge Insulation DEN CLST 1 ft 0 6 ft2 ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 3785 ft2 0 ft2 Medium N 0.2 No 0.9 No 22 30.3 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3268 ft2 N N FORM R405-2017 INPUT 5UMMAKY GNEGKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) GREAT RM 0 Blown 492 ft2 0.1 Wood 2 Under Attic (Unvented) BATH 4 0 Blown 60 ft2 0.1 Wood 3 Under Attic (U nvented) OFFICE 0 Blown 271ft2 0.1 Wood 4 Under Attic (Unvented) OFFICE CLST 0 Blown 28 ft2 0.1 Wood 5 Under Attic (Unvented) BEDROOM 3 0 Blown 222 ft2 0.1 Wood 6 Under Attic (Unvented) CLST 3 0 Blown 14 ft2 0.1 Wood 7 Under Attic (Unvented) BATH 2 0 Blown 105 ft2 0.1 Wood 8 Under Attic (Unvented) BEDROOM 2 0 Blown 205 ft2 0.1 Wood 9 Under Attic (Unvented) CLST 2 0 Blown 20 ft2 0.1 Wood 10 Under Attic (Unvented) HALL 0 Blown 48 ft2 0.1 Wood 11 Under Attic (Unvented) LAUNDRY 0 Blown 100 ft2 0.1 Wood 12 Under Attic (Unvented) BATH 3 0 Blown 72 ft2 0.1 Wood 13 Under Attic (Unvented) KITCHEN/DINET 0 Blown 423 ft2 0.1 Wood 14 Under Attic (Unvented) DINING RM 0 Blown 144 ft2 0.1 Wood 15 Under Attic (Unvented) FOYER 0 Blown 132 ft2 0.1 Wood 16 Under Attic (Unvented) MASTER BEDRO 0 Blown 403 ft2 0.1 Wood 17 Under Attic (Unvented) WIC 1 0 Blown 77 ft2 0.1 Wood 18 Under Attic (Unvented) M BATH 0 Blown 224 ft2 0.1 Wood 19 Under Attic (Unvented) WASH RM 0 Blown 42 ft2 0.1 Wood 20 Under Attic (Unvented) WIC 2 0 Blown 54 ft2 0.1 Wood 21 Under Attic (Unvented) DEN 0 Blown 126 ft2 0.1 Wood 22 Under Attic (Unvented) DEN CLST 0 Blown 6 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space o 1 E Exterior Concrete Block - Polystyr&REAT RM 0 5 0 12 0 60.0 ft2 0 0 0.2 0 2 S Exterior Concrete Block - Polystyr&REAT RM 0 24 0 12 0 288.0 ft2 0 0 0.2 0 3 S Exterior Concrete Block - PolystyrenBATH 4 0 7 0 10 0 70.0 ft2 0 0 0.2 0 4 W Exterior Concrete Block - Polystyren@ATH 4 0 7 0 10 0 70.0 ft2 0 0 0.2 0 5 E Exterior Concrete Block - Polystyrer@FFICE 0 16 0 12 0 192.0 ft2 0 0 0.2 0 6 S Exterior Concrete Block - Polystyrer@FFICE 0 17 0 12 0 204.0 ft2 0 0 0.2 0 7 W Exterior Concrete Block - Polystyrer@FFICE 0 3 0 12 0 36.0 ft2 0 0 0.2 0 8 E Exterior Concrete Block - Polystyi@f£ICE CLS 0 2 0 10 0 20.0 ft2 0 0 0.2 0 9 N Exterior Concrete Block - PolystyMDROOM 3 0 2 0 10 0 20.0 ft2 0 0 0.2 0 10 E Exterior Concrete Block - PolystyMDROOM 3 0 14 0 10 0 140.0 ft2 0 0 0.2 0 11 S Exterior Concrete Block - Polysty&EDROOM 3 0 2 0 10 0 20.0 ft2 0 0 0.2 0 12 E Exterior Concrete Block - PolystyrenDLST 3 0 2 0 10 0 20.0 ft2 0 0 0.2 0 13 E Exterior Concrete Block - Polystyren@ATH 2 0 7 0 10 0 70.0 ft2 0 0 0.2 0 14 E Exterior Concrete Block - PolystyMDROOM 2 0 15 0 10 0 150.0 ft2 0 0 0.2 0 15 N Garage Frame - Wood BEDROOM 2 13 13 0 10 0 130.0 ft2 0 0.1 0.2 0 16 N Garage Frame - Wood CLST 2 13 2 0 10 0 20.0 ft2 0 0.1 0.2 0 17 W Exterior Concrete Block - PolystyrdLAUNDRY 0 10 0 10 0 100.0 ft2 0 0 0.2 0 18 N Garage Frame - Wood LAUNDRY 13 10 0 10 0 100.0 ft2 0 0.1 0.2 0 11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space o 19 S Exterior Concrete Block - PolystyrKhWHEN/DI 0 9 0 12 0 108.0 ft2 0 0 0.2 0 20 W Exterior Concrete Block - PolystyrKhTeCHEN/DI 0 5 0 12 0 60.0 ft2 0 0 0.2 0 21 N Exterior Concrete Block - PolystyrGINING RM 0 12 0 13 4 160.0 ft2 0 0 0.2 0 22 N Exterior Concrete Block - Polystyren60YER 0 11 0 14 0 154.0 ft2 0 0 0.2 0 23 S Exterior Concrete Block - PolystyTER BE 0 19 0 12 0 228.0 ft2 0 0 0.2 0 24 W Exterior Concrete Block - Polystyd TER BE 0 19 0 12 0 228.0 ft2 0 0 0.2 0 25 W Exterior Concrete Block - Polystyrend/VIC 1 0 11 0 10 0 110.0 ft2 0 0 0.2 0 26 N Exterior Concrete Block - Polystyrerfd BATH 0 17 0 12 0 204.0 ft2 0 0 0.2 0 27 E Exterior Concrete Block - PolystyrerPd BATH 0 10 0 12 0 120.0 ft2 0 0 0.2 0 28 W Exterior Concrete Block - Polystyrertd BATH 0 16 0 12 0 192.0 ft2 0 0 0.2 0 29 N Exterior Concrete Block - Polystyrene DEN 0 11 0 11 4 124.7 ft2 0 0 0.2 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated LAUNDRY None .19 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 0.43 0.26 Y 24.0 ft2 14 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S 2 Metal Low-E Single Yes 0.43 0.26 Y 24.0 ft2 14 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 3 S 2 Metal Low-E Single Yes 0.69 0.22 Y 160.0 ft2 14 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 4 W 4 Metal Low-E Single Yes 0.69 0.22 Y 21.3 ft2 10 ft 6 in 1 ft 4 in None None 5 E 5 Metal Low-E Single Yes 0.43 0.26 Y 36.0 ft2 2 ft 6 in 1 ft 4 in None None 6 S 6 Metal Low-E Single Yes 0.52 0.21 Y 36.0 ft2 2 ft 6 in 1 ft 4 in None None 7 W 7 Metal Low-E Single Yes 0.43 0.26 Y 12.0 ft2 4 ft 6 in 1 ft 4 in None None 8 E 10 Metal Low-E Single Yes 0.66 0.19 Y 36.0 ft2 2 ft 6 in 1 ft 4 in None None 9 E 13 Metal Low-E Single Yes 0.43 0.26 Y 8.0 ft2 2 ft 6 in 1 ft 4 in None None 10 E 14 Metal Low-E Single Yes 0.66 0.19 Y 36.0 ft2 2 ft 6 in 1 ft 4 in None None 11 S 19 Metal Low-E Single Yes 0.43 0.26 Y 24.0 ft2 12 ft 6 in 1 ft 4 in None None 12 W 20 Metal Low-E Single Yes 0.43 0.26 Y 24.0 ft2 14 ft 6 in 1 ft 4 in None None 13 N 21 Metal Low-E Single Yes 0.43 0.24 Y 36.0 ft2 2 ft 6 in 1 ft 4 in None None 14 N 22 Metal Low-E Single Yes 0.69 0.22 Y 40.0 ft2 8 ft 6 in 1 ft 4 in None None 15 N 22 Metal Low-E Single Yes 0.69 0.22 Y 60.0 ft2 8 ft 6 in 1 ft 4 in None None 16 S 23 Metal Low-E Single Yes 0.66 0.21 Y 36.0 ft2 2 ft 6 in 1 ft 4 in Drapes/blinds None 17 S 23 Metal Low-E Single Yes 0.69 0.22 Y 64.0 ft2 12 ft 6 in 1 ft 4 in Drapes/blinds None 18 N 26 Metal Low-E Single Yes 0.52 0.21 Y 24.0 ft2 2 ft 6 in 1 ft 4 in Drapes/blinds None 19 W 28 Metal Low-E Single Yes 0.43 0.26 Y 8.0 ft2 2 ft 6 in 1 ft 4 in Drapes/blinds None 20 N 29 Metal Low-E Single Yes 0.43 0.24 Y 36.0 ft2 2 ft 6 in 1 ft 4 in None None 11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 950 ft2 950 ft2 25 ft 11 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000364 3122.8 171.43 322.41 .1458 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 27 kBtu/hr 1 COP:1 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Single SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 Single SEER: 16 17.7 kBtu/hr 531 cfm 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # ---- Supply---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 165 ft2 Attic 6 120 ft2 Attic Attic 17 ft2 Default Leakage Garage (Default) c(Default) c 12 ft2 Default Leakage Garage (Default) c(Default) c 1 1 2 2 11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: ling Jan Feb Mar Apr May Jun Jan H Feb H Mar �xJ j Jun rj rj Jul Aug rj �XjSep Oct Nov Dec Jan Venting Feb Mar Apr May Jun Jul Aug Sep Oct xl Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 GREAT RM Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 4 Default(8 Ibs/sq.ft. ftz ft 0.3 OFFICE Default(8 Ibs/sq.ft. ftz ft 0.3 OFFICE CLST Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ftz ft 0.3 HALL Default(8 Ibs/sq.ft. ftz ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ftz ft 0.3 BATH 3 Default(8lbs/sq.ft. ftz ft 0.3 KITCHEN/DINETTE Default(8 Ibs/sq.ft. ftz ft 0.3 DINING RM Default(8 Ibs/sq.ft. ftz ft 0.3 FOYER Default(8 Ibs/sq.ft. ftz ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ftz ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ftz ft 0.3 M BATH Default(8 Ibs/sq.ft. ftz ft 0.3 WASH RM Default(8 Ibs/sq.ft. ftz ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ftz ft 0.3 DEN Default(8 Ibs/sq.ft. ftz ft 0.3 DEN CLST 11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.