HomeMy WebLinkAboutBELAND- ENERGY CALCFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: BELAND RESIDENCE
Builder Name:
Street: 7964 PLANTATION LAKES DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL,
Permit Number:
Owner: EDDY AND CONNIE BELAND
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (3398.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead AggrER=0.0 3148.70 ft2
b. Frame - Wood, Adjacent
R=13.0 250.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (3268.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=22.0 3268.00 ft2
6. Conditioned floor area above grade (ft2) 3268
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(745.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 165
a. U-Factor: Sgl, U=0.69 345.33 ft2
b. Sup: Attic, Ret: Attic, AH: Garage
6 120
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.43 160.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.26
a. Central Unit
42.0 SEER:16.00
b. Central Unit
17.7 SEER:16.00
c. U-Factor: Sgl, U=0.66 72.00 ft2
SHGC: SHGC=0.19
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 168.00 ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC: other (see details)
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 8.343 ft.
Area Weighted Average SHGC: 0.226
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (3268.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 3268.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.228 Total Proposed Modified Loads: 109.64
PASS
Total Baseline Loads: 109.67
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
l�
Code.
calculation indicates compliance
G'QQ
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 11-5-2020
this building will be inspected for
compliance with Section 553.908
��19E SrAT
Q _ tt
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
Florida Statutes.
C7 ��i,�p� �.�`�•••�`
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
FORM R405-2017 INPUT 5UMMAKY CHECKLIST REPORT
PROJECT
Title:
BELAND RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 3268
Lot #
Owner Name:
EDDY AND CONNIE BELAND
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
7964 PLANTATION LA
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design
Daily Temp
v Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
2336
26735.2
2
AHU 2
932
10737.8
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfllID Finished Cooled
Heated
1
GREAT RM
492
5904
No
0
1
Yes
Yes
Yes
2
BATH 4
60
600
No
0
1
Yes
Yes
Yes
3
OFFICE
271
3252
No
0
1
Yes
Yes
Yes
4
OFFICE CLST
28
280
No
0
1
Yes
Yes
Yes
5
BEDROOM 3
222
2220
No
0
1
1
Yes
Yes
Yes
6
CLST 3
14
140
No
0
1
Yes
Yes
Yes
7
BATH 2
105
1050
No
0
1
Yes
Yes
Yes
8
BEDROOM 2
205
2050
No
0
1
1
Yes
Yes
Yes
9
CLST 2
20
200
No
0
1
No
Yes
Yes
10
HALL
48
480
No
0
1
No
Yes
Yes
11
LAUNDRY
100
1000
No
0
1
Yes
Yes
Yes
12
BATH 3
72
720
No
0
1
No
Yes
Yes
13
KITCHEN/DINETTE
423
5076
Yes
0
1
Yes
Yes
Yes
14
DINING RM
144
1915.2
No
0
1
Yes
Yes
Yes
15
FOYER
132
1848
No
0
1
Yes
Yes
Yes
16
MASTER BEDROO
403
4836
No
0
1
1
Yes
Yes
Yes
17
WIC 1
77
770
No
0
1
Yes
Yes
Yes
18
M BATH
224
2688
No
0
1
Yes
Yes
Yes
19
WASH RM
42
420
No
0
1
No
Yes
Yes
20
WIC 2
54
540
No
0
1
No
Yes
Yes
21
DEN
126
1423.8
No
0
1
Yes
Yes
Yes
11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22
DEN CLST 6
60
No
0
1 No
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
GREAT RM
29 ft
0
492 ft2
----
1 0
0
2 Slab -On -Grade Edge Insulation
BATH 4
14 ft
0
60 ft2
----
1 0
0
3 Slab -On -Grade Edge Insulation
OFFICE
36 ft
0
271 ft2
----
1 0
0
4 Slab -On -Grade Edge Insulation
OFFICE CLST
2 ft
0
28 ft2
----
1 0
0
5 Slab -On -Grade Edge Insulation
BEDROOM 3
18 ft
0
222 ft2
----
1 0
0
6 Slab -On -Grade Edge Insulation
CLST 3
2 ft
0
14 ft2
----
1 0
0
7 Slab -On -Grade Edge Insulation
BATH 2
7 ft
0
105 ft2
----
1 0
0
8 Slab -On -Grade Edge Insulation
BEDROOM 2
15 ft
0
205 ft2
----
1 0
0
9 Slab -On -Grade Edge Insulation
CLST 2
1 ft
0
20 ft2
----
1 0
0
10SIab-On-Grade Edge Insulation
HALL
1 ft
0
48 ft2
----
1 0
0
11SIab-On-Grade Edge Insulation
LAUNDRY
loft
0
100 ft2
----
1 0
0
12SIab-On-Grade Edge Insulation
BATH 3
1 ft
0
72 ft2
----
1 0
0
13SIab-On-Grade Edge Insulation
KITCHEN/DINET
14 ft
0
423 ft2
----
1 0
0
14SIab-On-Grade Edge Insulation
DINING RM
12 ft
0
144 ft2
----
1 0
0
15SIab-On-Grade Edge Insulation
FOYER
11 ft
0
132 ft2
----
1 0
0
16SIab-On-Grade Edge Insulation
MASTER BEDRO
38 ft
0
403 ft2
----
1 0
0
17SIab-On-Grade Edge Insulation
WIC 1
11 ft
0
77 ft2
----
1 0
0
18SIab-On-Grade Edge Insulation
M BATH
43 ft
0
224 ft2
----
1 0
0
19SIab-On-Grade Edge Insulation
WASH RM
1 ft
0
42 ft2
----
1 0
0
20SIab-On-Grade Edge Insulation
WIC 2
1 ft
0
54 ft2
----
1 0
0
21SIab-On-Grade Edge Insulation
DEN
11 ft
0
126 ft2
----
1 0
0
22SIab-On-Grade Edge Insulation
DEN CLST
1 ft
0
6 ft2
----
1 0
0
ROOF
Roof
Gable
Roof
Rad
Solar SA Emitt
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor. Tested
Tested Insul.
(deg)
1 Hip Flat tile/slate 3785 ft2
0 ft2
Medium
N
0.2 No 0.9
No 22
30.3
ATTIC
V
# Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Unvented
0
3268 ft2
N N
FORM R405-2017 INPUT 5UMMAKY GNEGKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) GREAT RM
0
Blown
492 ft2
0.1
Wood
2
Under Attic (Unvented) BATH 4
0
Blown
60 ft2
0.1
Wood
3
Under Attic (U nvented) OFFICE
0
Blown
271ft2
0.1
Wood
4
Under Attic (Unvented) OFFICE CLST
0
Blown
28 ft2
0.1
Wood
5
Under Attic (Unvented) BEDROOM 3
0
Blown
222 ft2
0.1
Wood
6
Under Attic (Unvented) CLST 3
0
Blown
14 ft2
0.1
Wood
7
Under Attic (Unvented) BATH 2
0
Blown
105 ft2
0.1
Wood
8
Under Attic (Unvented) BEDROOM 2
0
Blown
205 ft2
0.1
Wood
9
Under Attic (Unvented) CLST 2
0
Blown
20 ft2
0.1
Wood
10
Under Attic (Unvented) HALL
0
Blown
48 ft2
0.1
Wood
11
Under Attic (Unvented) LAUNDRY
0
Blown
100 ft2
0.1
Wood
12
Under Attic (Unvented) BATH 3
0
Blown
72 ft2
0.1
Wood
13
Under Attic (Unvented) KITCHEN/DINET
0
Blown
423 ft2
0.1
Wood
14
Under Attic (Unvented) DINING RM
0
Blown
144 ft2
0.1
Wood
15
Under Attic (Unvented) FOYER
0
Blown
132 ft2
0.1
Wood
16
Under Attic (Unvented) MASTER BEDRO
0
Blown
403 ft2
0.1
Wood
17
Under Attic (Unvented) WIC 1
0
Blown
77 ft2
0.1
Wood
18
Under Attic (Unvented) M BATH
0
Blown
224 ft2
0.1
Wood
19
Under Attic (Unvented) WASH RM
0
Blown
42 ft2
0.1
Wood
20
Under Attic (Unvented) WIC 2
0
Blown
54 ft2
0.1
Wood
21
Under Attic (Unvented) DEN
0
Blown
126 ft2
0.1
Wood
22
Under Attic (Unvented) DEN CLST
0
Blown
6 ft2
0.1
Wood
WALLS
Adjacent Cavity
Width
Height
Sheathing Framing Solar
Below
Space
o
1
E
Exterior Concrete Block - Polystyr&REAT RM
0
5
0 12
0
60.0 ft2
0
0
0.2
0
2
S
Exterior Concrete Block - Polystyr&REAT RM
0
24
0 12
0
288.0 ft2
0
0
0.2
0
3
S
Exterior Concrete Block - PolystyrenBATH 4
0
7
0 10
0
70.0 ft2
0
0
0.2
0
4
W
Exterior Concrete Block - Polystyren@ATH 4
0
7
0 10
0
70.0 ft2
0
0
0.2
0
5
E
Exterior Concrete Block - Polystyrer@FFICE
0
16
0 12
0
192.0 ft2
0
0
0.2
0
6
S
Exterior Concrete Block - Polystyrer@FFICE
0
17
0 12
0
204.0 ft2
0
0
0.2
0
7
W
Exterior Concrete Block - Polystyrer@FFICE
0
3
0 12
0
36.0 ft2
0
0
0.2
0
8
E
Exterior Concrete Block - Polystyi@f£ICE CLS
0
2
0 10
0
20.0 ft2
0
0
0.2
0
9
N
Exterior Concrete Block - PolystyMDROOM 3
0
2
0 10
0
20.0 ft2
0
0
0.2
0
10
E
Exterior Concrete Block - PolystyMDROOM 3
0
14
0 10
0
140.0 ft2
0
0
0.2
0
11
S
Exterior Concrete Block - Polysty&EDROOM 3
0
2
0 10
0
20.0 ft2
0
0
0.2
0
12
E
Exterior Concrete Block - PolystyrenDLST 3
0
2
0 10
0
20.0 ft2
0
0
0.2
0
13
E
Exterior Concrete Block - Polystyren@ATH 2
0
7
0 10
0
70.0 ft2
0
0
0.2
0
14
E
Exterior Concrete Block - PolystyMDROOM 2
0
15
0 10
0
150.0 ft2
0
0
0.2
0
15
N
Garage Frame - Wood BEDROOM 2
13
13
0 10
0
130.0 ft2
0
0.1
0.2
0
16
N
Garage Frame - Wood CLST 2
13
2
0 10
0
20.0 ft2
0
0.1
0.2
0
17
W
Exterior Concrete Block - PolystyrdLAUNDRY
0
10
0 10
0
100.0 ft2
0
0
0.2
0
18
N
Garage Frame - Wood LAUNDRY
13
10
0 10
0
100.0 ft2
0
0.1
0.2
0
11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
Space
o
19
S
Exterior
Concrete Block - PolystyrKhWHEN/DI
0
9
0
12
0
108.0 ft2
0
0 0.2
0
20
W
Exterior
Concrete Block - PolystyrKhTeCHEN/DI
0
5
0
12
0
60.0 ft2
0
0 0.2
0
21
N
Exterior
Concrete Block - PolystyrGINING RM
0
12
0
13
4
160.0 ft2
0
0 0.2
0
22
N
Exterior
Concrete Block - Polystyren60YER
0
11
0
14
0
154.0 ft2
0
0 0.2
0
23
S
Exterior
Concrete Block - PolystyTER BE
0
19
0
12
0
228.0 ft2
0
0 0.2
0
24
W
Exterior
Concrete Block - Polystyd TER BE
0
19
0
12
0
228.0 ft2
0
0 0.2
0
25
W
Exterior
Concrete Block - Polystyrend/VIC 1
0
11
0
10
0
110.0 ft2
0
0 0.2
0
26
N
Exterior
Concrete Block - Polystyrerfd BATH
0
17
0
12
0
204.0 ft2
0
0 0.2
0
27
E
Exterior
Concrete Block - PolystyrerPd BATH
0
10
0
12
0
120.0 ft2
0
0 0.2
0
28
W
Exterior
Concrete Block - Polystyrertd BATH
0
16
0
12
0
192.0 ft2
0
0 0.2
0
29
N
Exterior
Concrete Block - Polystyrene DEN
0
11
0
11
4
124.7 ft2
0
0 0.2
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated LAUNDRY
None
.19
3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E
1
Metal Low-E Single Yes
0.43
0.26
Y
24.0 ft2
14 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2
S
2
Metal Low-E Single Yes
0.43
0.26
Y
24.0 ft2
14 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
3
S
2
Metal Low-E Single Yes
0.69
0.22
Y
160.0 ft2
14 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
4
W
4
Metal Low-E Single Yes
0.69
0.22
Y
21.3 ft2
10 ft 6 in
1 ft 4 in
None
None
5
E
5
Metal Low-E Single Yes
0.43
0.26
Y
36.0 ft2
2 ft 6 in
1 ft 4 in
None
None
6
S
6
Metal Low-E Single Yes
0.52
0.21
Y
36.0 ft2
2 ft 6 in
1 ft 4 in
None
None
7
W
7
Metal Low-E Single Yes
0.43
0.26
Y
12.0 ft2
4 ft 6 in
1 ft 4 in
None
None
8
E
10
Metal Low-E Single Yes
0.66
0.19
Y
36.0 ft2
2 ft 6 in
1 ft 4 in
None
None
9
E
13
Metal Low-E Single Yes
0.43
0.26
Y
8.0 ft2
2 ft 6 in
1 ft 4 in
None
None
10
E
14
Metal Low-E Single Yes
0.66
0.19
Y
36.0 ft2
2 ft 6 in
1 ft 4 in
None
None
11
S
19
Metal Low-E Single Yes
0.43
0.26
Y
24.0 ft2
12 ft 6 in
1 ft 4 in
None
None
12
W
20
Metal Low-E Single Yes
0.43
0.26
Y
24.0 ft2
14 ft 6 in
1 ft 4 in
None
None
13
N
21
Metal Low-E Single Yes
0.43
0.24
Y
36.0 ft2
2 ft 6 in
1 ft 4 in
None
None
14
N
22
Metal Low-E Single Yes
0.69
0.22
Y
40.0 ft2
8 ft 6 in
1 ft 4 in
None
None
15
N
22
Metal Low-E Single Yes
0.69
0.22
Y
60.0 ft2
8 ft 6 in
1 ft 4 in
None
None
16
S
23
Metal Low-E Single Yes
0.66
0.21
Y
36.0 ft2
2 ft 6 in
1 ft 4 in
Drapes/blinds
None
17
S
23
Metal Low-E Single Yes
0.69
0.22
Y
64.0 ft2
12 ft 6 in
1 ft 4 in
Drapes/blinds
None
18
N
26
Metal Low-E Single Yes
0.52
0.21
Y
24.0 ft2
2 ft 6 in
1 ft 4 in
Drapes/blinds
None
19
W
28
Metal Low-E Single Yes
0.43
0.26
Y
8.0 ft2
2 ft 6 in
1 ft 4 in
Drapes/blinds
None
20
N
29
Metal Low-E Single Yes
0.43
0.24
Y
36.0 ft2
2 ft 6 in
1 ft 4 in
None
None
11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
950 ft2
950 ft2
25 ft 11 ft 13
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000364
3122.8 171.43 322.41 .1458 5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COP:1 27 kBtu/hr 1
COP:1 17 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
Single SEER: 16 42 kBtu/hr 1260 cfm 0.8 1
Single SEER: 16 17.7 kBtu/hr 531 cfm 0.8 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.98 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
V #
---- Supply----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
2
Attic 6 165 ft2
Attic 6 120 ft2
Attic
Attic
17 ft2 Default Leakage Garage (Default) c(Default) c
12 ft2 Default Leakage Garage (Default) c(Default) c
1 1
2 2
11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
ling Jan
Feb
Mar
Apr
May
Jun
Jan
H
Feb
H
Mar
�xJ
j
Jun
rj
rj Jul
Aug
rj
�XjSep
Oct Nov
Dec
Jan
Venting
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct xl
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
GREAT RM
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BATH 4
Default(8 Ibs/sq.ft.
ftz
ft
0.3
OFFICE
Default(8 Ibs/sq.ft.
ftz
ft
0.3
OFFICE CLST
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ftz
ft
0.3
CLST 3
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ftz
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ftz
ft
0.3
BATH 3
Default(8lbs/sq.ft.
ftz
ft
0.3
KITCHEN/DINETTE
Default(8 Ibs/sq.ft.
ftz
ft
0.3
DINING RM
Default(8 Ibs/sq.ft.
ftz
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ftz
ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
ftz
ft
0.3
WIC 1
Default(8 Ibs/sq.ft.
ftz
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ftz
ft
0.3
WASH RM
Default(8 Ibs/sq.ft.
ftz
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ftz
ft
0.3
DEN
Default(8 Ibs/sq.ft.
ftz
ft
0.3
DEN CLST
11/5/2020 12:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
This document was created with Win2PDF available at http://www.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.