Loading...
HomeMy WebLinkAboutEnergy Code\ c FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Regulation -.'Residential; Performance .Method N . Project Name: WYNNE-THE -MAN O-R, IMPACT Builder Name: WYNNE BUILDING CORP.. Street: THE -MANOR 71 � Permit Office: :ST. LUCIE.COUNTY City, State; Zip-., FT.:PIERCE', FL, . Permit Number:. : ' Owner: WYNNE BUILDING CORP. w C Jurisdiction: Design Location: FL, FortPierce County: - St. Lucie (Florida'Climate Zone 2 ) 1.: New construction or existing. New (From.Plans) 9.. Wall Types.(1654.2' sgft.) Insulation .Area 2. Single family or multiple family. Single-family ' a.'Concrete Block -.Int-Insul, Exterior. R=4.1 - 1374.20 ftZ b..Frame - Wood, Adjacent R=11.0 280.00 ftZ : 3. Number of units, if multiple family- 1 c. N/A R-:ftZ 4.' Number of Bedrooms . 2: d. N/A ' R= .. fE= . . 5. Is this a worst case? Yes 10. Ceiling Types. (1754.0 sgft.) Insulation .:.Area. .. a: Under Attic (Vented) R=30.0. 1724.00 ft2 ., 6. Conditioned floor area above grade (ftZ) 1724 - b. Knee, Wall .(Vented) :R=19.0 36.60 ftZ : Conditioned floor area below grade (ft2j 0 c. N/A R= ftZ .. 11. Ducts - R ftz. 7. Windows(153.4 sq%) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 150 a. U Factor: Sgl, U1:04 113.35 ftZ SHGC: SHGC=0.26 ti. U-Factor: Sgl, U=1.11 40.00 ftZ. 12. Cooling systems -. -kB.tu/hr - 'Efficiency .. SHGC: SHGC=0.27. a. Central Unit ,' . " .34.8 .SEER:15.00 c. U-Factor: N/A : - SHGC.: 13. Heating systems ': kBtu/hr . ':Efficiiency d. U-Factor: N/A ftZ. - a. Electric Heat Pump, . 34.8- •HSPF:8.50 SHGC:. Area Weighted AJerage:Overhang Depth: 3:010 ft.: ' Area Weighted Average SHGC:,: Q.285 .- 14. Hot water systems ; a: Electric Cap:.50 gallons 8. Floor Types (1723.6 sqft.) Insulation . Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1723.50 ftZ b. Conservation features - . 'b.. N/A . ' -.R= ' . ftZ.: None. c.- N/A.: R= ftZ .... .. 15 Credits : Pstat ...' . Total Proposed Modified Loads: 53.45 Glass/Floor Area: 0.089 A �� Total Baseline Loads: 54.1.2 hereby certify that the plans and specifications covered by - Review of the plans and - this calculation are in compliance -with the.Florida Energy specifications covered.by this Code. -calculation. indicates compliance �� with the Florida Energy'Code.: $ Nirir'x4 M1sr • PREPARED BY' DATE: 1-9-20 Before construction is:completed this building will, be inspectedfor compliance with Section 553.908. - .hereb certify that this buildiri , as designed, is in compliance. Y fY; 9 9_ Florida Statutes. . with 4he. Florida Energy Code .... OWNER/AQE T: - BUILDING OFFICIAL: DATE:: DATE: -. Compliance requires certification bythe air handler unit manufacturer tha .th le enclosure qualifies as. certifiedfactory-sealed in accordance with R40112.1. Compliance requires an. Air Barrier. And Insulation Inspection Checklist in accor project requires -an envelope.leakage.-test report with envelope leakage no greater than 5.00 ACH50 O®E COMPLBANCE ST. LUCIE COUNTY t B Rff C'C 1:/8/2020 4:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017. FBC. 6th Edition, (2017) Compliant Software-. Page 1. of 6 , FORM.R405-2017 INPUT. 5UMMARY:GIIE1L;KL151 KhPUKI . PROJECT. Title: WYNNE THE MANOR :IMPA Bedrooms: 2 Address Type:: Street Address Building Type: User Conditioned Area: 1724 Lot # Owner Name: WYNNE BUILDING COR.P. Total Stories: 1 - Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: _ WYNNE BUILDING CORP.- Rotate Angle:. 270 - Street:. THE MANOR 71. Permit Office: ST. LUCIE COUNTY Cross Ventilation:. No County:., St. Lucie . Jurisdiction: Whole House Fan: No City, State; Zip:.- FT. PIERCE., . Family Type: Single-family- _ FL New/Existing: New,(From Plans) Comment:. . CLIMATE . / Design Temp Int Design Temp Heating Design Daily Temp' Design Location TMY Site . 97.5 % 2.5 % Winter - Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH MUNI 39 90 70 75 299 62- tow: BLOCKS Number Name Area. Volume .1 Entire.House" 1724 14774.8 SPACES: Number: Name: Area : Volume Kitchen . Occupants- :Bedrooms: InfillD Finished Cooled . :Heated 1 GREAT ROOM 546 5350.8 No 0 1 Yes Yes Yes 2: MASTER BEDROO 354 2832 : No 2 1 1 . Yes Yes: :Yes " .... .. .. .... .. .. .. 3 - WIC.- 77 .... .. .. 616 No .. 0 .... 1: .. .. No ... .Yes .-Yes'. 4 -CLST. 35. 280 No 0 1 . No .: Yes -Yes . 5 M BATH 54 " 432 No . 0 1 .. Yes. Yes Yes 6 - KITCHEN 18.0: 1440 Yes 0 1 'Yes Yes " Yes 7 JUNIOR M. BED 198 1584 No- .01 1:_ 1 Yes - Yes Yes -8 BATH 50 -400. No 0 1 No Yes Yes 9 POWDER 35: 280 No 0. 1 .Yes Yes Yes 10 NOOK 42 336 No 0 1' Yes Yes Yes 11 - LAUNDRY - 49 392 No - 0 - 1 - Yes Yes Yes .12 ENTRY 104 . 832- No 0 1 Yes Yes- Yes' FLOORS 7 . Floor Type Space. Perimeter Perimeter R-Value . Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio ,:GREAT ROOM . 47.ft • 0 646 ft', : __ 0 ' . -1 0 2SIab-On=Grade Edge Insulatio MASTER BEDRO 46 ft . .0. 354.ft2 0. 1 0 . 3-Slab-On-Grade Edge: Insulatio WIC 1 ft - :0 - :77 ft= _e - 0 : 1: 0 4SIab=On-Grade Edge-Insulatio CLST. 1 ft 0 35 ftZ. 0 1 0 5 Slab -On -Grade Edge Insulatio M BATH 9 ft 0 54 ft'. 0. 1 0 FORM R405-2017 INPUT. SUMMAKY GIitGKLIb I KCPUK I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area - Joist R-Value Tile Wood Carpet: 6 Slab -On -Grade Edge-Insulatio KITCHEN Ifft 0 180 ft2 0 1. 0 7.Slab-On-Grade Edge Insulatio JUNIOR M. BED 14 ft 0 198 ft2 0 1 0. 8 Slab -On -Grade Edge Insulatio BATH 1 ft 0 50 ft2 0 1" 0 . 9 Slab -On -Grade Edge Insulatio POWDER 5 ft 0 35 ft?" __ 0 1 .0 AOSIab-On=Grade Edge. Insulatio NOOK- 6 ft 0 42 ft2.. _ .0 : 1 0. 11SIab-On-Grade Edge. Insulatio LAUNDRY 17 ft . 0 -49 ft2: __� . 0" 1: 0 12SIab-On-Grade Edge Insulatio ENTRY. 5.9 ft 0 16.5. ft2 .. ____ 0 . 1 0. ROOF: Roof Gable. Roof Rad Solar SA" Emitt -Ernitt• Deck Pitch V # . Type Materials Area Area Color Barr. . Absor. Tested . Tested Insul. (deg) 1 Hip Metal 1817 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC ,. V # . Type Ventilation Vent Ratio (1 in) Area : RBS IRCC 1 -Full attic Vented 300 1724 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1- Under Attic (Vented) GREAT ROOM 30 _ Blown 546 ft2 0.1 Wood- . 2 UnderAttic (Vented) MASTER BEDRO . 30 Blown 354 ft2 0.1 Wood 3 . Under.Attic (Vented) W16 :30. Blown 77 ft2 0.1 Wood . 4, Under Attic (Vented) CLST. 30 Blown 35 ft?, 0.1. Wood " 5. Under Attic (Vented) M BATH 30 Blown .. 54 ft2 0A Wood " -6 Under Attic (Vented) KITCHEN 30 Blown 180 ft? 0.1 Wood. 7 Under Attic (Vented) JUNIOR M. BED 30 Blown 198 ft2 0.1 Wood 8 Under Attic (Vented) BATH 30 Blown 50 ft2: 0.1 : Wood 9 Under Attic (Vented) POWDER. .. :30 Blown 35 12 0.1. Wood 10 Under Attic (Vented) NOOK 30 Blown " . 42-ft2 0.1 Wood 11 . Under Attic (Vented) " LAUNDRY' 30 Blown 49 ft2 0.1. Wood . 12 Under Attic (Vented) ENTRY 30 Blown. 104 ft2 -0.1 Wood 13 Knee Wall (Vented) GREAT ROOM 19 Blown. 30 ft2 0.1'1 .. Wood WALLS Adjacent Space.- Cavity Width In Height Pf Sheathing Framing ., Solar - Below 1 SW=>SE Exterior Concrete Block-- Int InsGREAT ROO 4.1 26 0 9 10 255.7 ft2 0 0 0.3 0 2 'NW=>S Exterior Concrete Block -. Int Ins(HREAT ROO -4.1 21 0 9 10 .206.5ft- 0 0 0.3. 0 - 3 NE=>NW Exterior. Concrete Block- Int InsMASTER BE 4.1 25 0 8 0' 200.0 ft2 0 0 0.3 0 • FORM• 14405=2017 INPUT SUMMARY: CHECKLIST REPORT WALLS . Adjacent' - .Space,. Cavity Width Height :" Sheathing Framing :.'Solar Below 4' SW=>SE Exterior Concrete Block - Int lnsMASTER BE 4.1 8 0 8 0 64.0 ft2 0 0 6.3 0 5 'NW=>S Exterior .Concrete Block -. Int InsMASTER BE .4.1 13 .0 8 0 104.0 ft2 0 0. 0.3. 6 6 NE=>NW Exterior Concrete Block - Int Insul M BATH 4A 9 0 8 0 72.0 ft2 0--' • 0 0.3 0 7 SW=>SE Exterior Concrete. Block- Int InsulKl fCHEN 4:1. 11 0 ' 8 0 88.0 ft2 0 .0-' : 0.3 -0 8 NE=>NW Exterior Concrete Block - Int InsdUNIOR M. B 4.1 14 0.: 8 0 .: 112.0 ft2 0 .= 0 0.3 0 9 SW=>SE Exterior -Concrete Block - Int InsuIPOWDER. 4.1 5. 0 8 0. 40.0 ft2 0. 0- 0.3 0 10 SW='>SE Exterior " Concrete Block, Int Insul NOOK .. . .... . .... 4.1 6 .. ... 0 .8 0 : -. 48.0 ft2 -. 0: ". .. .. .... 0 : .. 0.3 -0 .. 11 NE=>NW Exterior Concrete Block- Int InsuLAUNDRY 4.1 .3. 0 8. 0. 24.0 ft2 ; 0 0 . 0:3 0 12 SE=>NE Exterior Concrete Block - Int InsuLAUNDRY . 4.1 7 0 " .8 .0 56.0 ft2 .0- 0 0.3 0. 13 SW=>SE Exterior Concrete Block,- Int InsuLAUNDRY - 4.1 7. 0 8. 6: " 56.0 ft2- •' .. • 0 : 0 0.3 . ,' .0 14. SE=>NE -Exterior Concrete Block - Int Insul -ENTRY 4A .6 .0 ..8, 0, ...48.0 ft2 •. 0 0.. 0.3 • -0 15 N=>W Garage " Frame - Wood ENTRY' 11 . 35 8- 280.0 W 0.23 0.3 0 DOORS # Ornt . Door Type Space Storms U-Value Width Height Area . Ft In Ft In- 1 SE=>NE' 'Insulated ENTRY None .32 3 6 8 20 ft2 .:WINDOWS .. Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang . V # Ornt,..ID• Frame Panes:_ NFRC U-Factor SHGC Imp Area. Depth" Separation Int-Shade Screening 1 ' SW=>SE 1 Metal -Low E Single Yes 1.04 . 0.29, .-N 46.4 ft2 1 ft 0 in 1 ft 5 in None- None 2-:NW=>SW2 :Metal : Low-E Single - :Yes :1. 11: .0.27. N 40.0 ft2: 8 ft 0 in -: 1.ft 5 in None None: 3 NW=>SW 5. ' Metal Low-E Single Yes' 1.04 0."29 N • 32.4 ft2 . 1 ft 0 in' .1 ft 5 in None . None 4 . NE=>NW 6. ; .Metal . Low-E Single- . Yes -1.04 . 0.29 . - N :.6.9 ft2 . 1 ft 0 in .1 ft 5 in .. None . _ .. None. . 5 NE -NW 8:'- Metal Low.-E•Single Yes 1.04. 0:29• N 16.2 ft2 :1 ft 0 in " 1 ft 5 in None None - 6 SW=>SE 9 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft2 '1 ft 0 in 1 ff 5 in"- None None 7 SE=>NE 12_ Metal Low-E Single Yes 1,04 : 0.29 N 4.7 ft2 : 7 ft 0 in :1 ft5 in, None:. None :GARAGE # :Floor Area- . " Ceiling Area Exposed Wall Perimeter Avg. Wall Height: -Exposed Wall dnsulation 1 440 ft2 . 440 ft2: 35 ft 8 ft. 11 .... . ... .. .... .. .. . .. .... .. .. INFILTRATION .... .. # Scope _ Method' .. .. SLA .. CFM 50 :ELA EgLA. - .. ACH ACH 50. 1 WKolehouse Proposed ACH (50). ' 000272: 1231.2 67.59 127.12 .097 :5 FORM R405-2017 INPUT5UMMAKY:GIIEGKLIST REPUKT HEATING SYSTEM # System Type : Subtype Speed Efficiency - ;Capacity : : Block Ducts 1 Electric -Heat Pump/ None Singl HSPF:8.5 3448 kBtu/hr : 1: SO, COOLING SYSTEM # . System Type. Subtype Subtype . Efficiency. Capacity Air Flow SHR Block Ducts 1 - . Central Unit/ - _ Split -Sing) SEER: 15 -34.8 kBtu/hr 1044 cfm - 0.85: :1 - sys#1: HOT WATER SYSTEM System Type . SubType Location' EF: -Cap Use SetPnf : .. Conservation 1 Electric None Garage 0,95 ,50 gal 60.9 gal:. 120 deg None SOLAR HOT WATER SYSTEM . . . FSEC : Collector . Storage: -:Cert # Company Name - System Model # Collector Model # Area - Volume FEF None None. ft2. DUCTS.. / — Supply"— -- Return -- : Air: CFM 25. CFM25 HVAC # V: # Location R-Value Area - : • • Location Area Leakage Type Handler - -TOT, -OUT QN RLF- Heat Cool A Attic 6, 150 ft2 Attic' ... . .... -' 45 ft2 Default Leakage Attic: . .... .. .. (Default) (Default) .. .:.. - TEMPERATURES Pro able Thermostat: Y Ceiling Fans.' CoolingJan- Feb Mar - ,Heal - - Jan - . Feb f X� Mar Apr . f Apr•. I May Jun - Jul _ Auge May Jun Jul Aug Sep Oct : .Nov. f Oct Nov Dec Dec Ventin Jan• Feb [X Mar [ A r May Jun Jul Au Se [X Oct X Nov -Dec Thermostat Schedule: :HERS 2006 Reference Hours Schedule Type. 1 2 3 . 4 5 .. .. 6 7 8 9 10 .. 11 . . ' 12 Cooling (WD) - AM. 78 78 • 78 ..78. 78 78 78:- -78. '- 80 80 80- 80 PM 80 80 78 78 78 78 78 78 78 78 '78 78 Cooling (WEH) AM . 78 78 -78 78 .78 78 -78 78 78 78 78 78 PM. .: 78. _-78 .78. 78 -78 78, 78 78. 78 .78 , . 78 . 78. Heating (V11D) AM 66 66 66 66 66 68 : 68 68 68 68 68 68 PM 68 68 .68 68 68 68. 68• .68 68 68 66. .66 Heating (WEH) AM • 66 66 66 66 66 68 68 68. 68 .68 68 68 PM: • 68 68 68: 68 68 68 68 68 :68 68 66 66: ... .. ....... MASS .. .... .. .. : . Mass Type- Area Thickness Furniture Fraction Space . .. .. Default(8 lbs/sq.ft. 0 ft2 Oft .. :.. . - 0.3. BEDROOM -Default(8 Ibs/sq.ft: ft2 .. .. .. .. ft 0:3 WIC . Default(8 lbs/sq.ft. ft2 ft 0.3 M. BATH Default(814s/sq.ft. ft2. ft ..- 0.3.. KITCHEN . Def6ult(8lbs/sq.ft. : ft2. - ft 0.3 : BATH Default(8.lbs/sq:ft:, - ft? ._ ft . 0.3 BEDROOM 2. Defaylt(8 Ibs/sq.ft. ft2 ft - . 0:3 ENTRY ' Default(81bs/sq.ft. ft2: ft :0.3 :LAUNDRY FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT MASS . Mass Type Area Thickness: Furniture, Fraction: Space; Default 8 ltis/s :ft. �ftz .3 GREAT/DINING ft 0 Project Name: _ WYNNE THE.MANOR IMPACT Builder Name:. WYNNE BUILDING CORP._ Street:. THEWANOR 71 Permit Office: ST.:LUCIE COUNTY City; State, Zip: FT: PIERCE , FL, Permit Number:: Y W Owner: = WYNNE BUILDING CORP. Jurisdiction: :Design Location:: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA : General A continuous air barrier shall be installed in the building envelopa. Air -permeable insulation shall requirements The exterior thermal envelope contains a. continuous air barrier.. -or not be used as a sealing material. Breaks joints in the air barrier shall be sealed.. Ceiling/attic , The air barrier in:any dropped ceiling/soffit: shall be aligned with The insulation in any dropped ceiling/soffit . the. insulation and an a s in the.air.barrier-shall be sealed. . Y 9 P. . - shall be aligned with the,air barrier. . Access. openings, drop downstairs or knee wall doors_ to unconditioned attic spaces shall be sealed. WallsThe junction of the foundation and sill:plate shall'be sealed.: Cavities within comers:and headers of frame walls "by The junction of the top :plate:and the top of exterior walls shall be shall be insulated completely filling the:cavity . . sealed. with a material having a Thermal resistance of R-3% Knee walls shall be sealed. per inch minimum. Exterior thermal envelope:insulatiori for framed .: walls shall be installed in substantial contact and continuous alignment with the air barrier. , Windows':skylight's . The s ace. between window%door `ambs-and framing,. and and doors skylights and framing shall be sealed. Rim joists . Rim joists shall include the air barrier:. Rim joists shall be insulated. -Floors: The air barrier shall be: installed at any exposed edge of : Floor framing: cavity insulation shall be-installed'to " (including.. insulation. • maintain permanent contact with the underside of above -garage: subfloor decking, or floor framing cavity insulation : and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the. bottom. to the top of all perimeter floor framing . . members.. . Crawl space walls Exposed earth in rinvented crawl spaces shall be covered with - Where.provided instead of.floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,: penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned s ace shall be sealed.. ' - - Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities - cavities shall be filled by insulation that.on installation readily conforms to the available cavity . spaces: Garage separation Air sealing shall be provided between the garage and conditioned'spa. s. Recessed. lighting Recessed light fixtures installed. in the building thermal envelope Recessed light fixtures installed in the building . shall be sealed to the drywall. thermal envelope shall -be air tight and IC rated.. Plumbing and wiring.: Batt insulation shall be cut neatly to ft around wiring and, plumbing in exterior walls, or insulation that on installation readily conforms to available space shall • Shower/tub . The air barrier installed at exterior walls.adjacent to: showers and Exterior walls: adjacent to showers and tubs shall• onexteriorwall tubs shall separate them from the'showers.and tubs. - be insulated.: Electrical/phone box.or The air barrier shall. be installed behind.electrical or communication exterior walls boxes -or air -sealed boxes shall be installed. HVAC. register boots HVAC register boots that penetrate building thermal envelope.shall be sealed to. the sub=floor or. drywall. Concealed i When required to be sealed, concealed fire sprinklers: shall only be sprinklers sealed -in a niannerthat is recommended. by the manufacturer:.: ' Caulking or other adhesive sealants shall not be used to fill voids a. In addition, -inspection of log walls shall be in accordance with the provisions:of ICC-400: 1/8/2020 4:36 PM EnergyGauge@ USA 6.0:02 (Rev.,1) - FlaRes2017 FBC 6th Edition (2017)• Compliant Software Page 1 of 1. 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL)-DISPLAY: CARD'.. ESTIMATED ENERGY PERFORMANCE INDEX* _ 99, The lower. the Energy Performance Index, the more :efficient the home. 1. New home or, addition 1. -New (From Plans) 12. Ducts, location & insulation level 6) Supply ducts .. R 6.0 2: Single-family.or multiple -family 2. Single-family b) Return ducts,. R.- .: -6.0- - - c) AHU location . : Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4: .2 13. Cooling system: Capacity 34.8 a) Split system, SEER 15.0 . 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP , . 6. Conditioned floor area (sq. ft.) , 6. 1724 d) Room unit/PTAC EER . - e) Other . . 7. Windows, type and area ' U-factor:(weighted average.) 7a. 1.058 ..a) b) Solar Heat Gain Coefficient-(SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area.: 7c. 153.4 a). Split: system heat pump .: HSPF -- . b), Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, naturafgas,: AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace,. LPG AFUE f) Other 8.50 9. Floor type,.insulation level: a) Slab-on=grade (R-value) 9a.. 0.0. b) Wood, -raised (R-value) 96. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95-. b)Gas fired; natural gas. EF 10. Wall type.and insulation: c) Gas fired,. LPG .. EF. A. Exterior: d) Solar system with tank EF A. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2.- Masonry:(Insulation-R-value) . 10A2. 4.1 f) Heat.recovery unit, HeatRec% B: Adjacent:. 9) Other 1. Wood frame (Insulation R-value) -10B1. .11.0 2. Masonry (Insulation R-value) 10132. 16..HVAC credits -claimed (Performance Method)- 11. Ceiling type and insulation level a) Ceiling fans . a) Under attic 11a. 30.0- b)Cross ventilation No b) Single assembly :11 b: c) Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit - d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building,Code, Energy Conservation, through the'above energy saving features. whichmill. be installed (or exceeded) in this home before final inspection. Otherwise, a new. EPL display card will. be completed based.on installed code compliant -features.- Builder Signature: - - Date: Address of New.Home:. THE MANOR 71. � �. . ` V C-C-CCity/FL Zip: - FT. PIERCE, FL 1/8/2020 4:36:22 PM - : EnergyGauge®. USA 6.0.04 (Rev: 1) = FlaRes2017 FBC 6th Edition (2017):Compliant Software .Page 1 of 1