HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA. ENERGY EFFICIENCY CODE FOR BUILDING. CONSTRUCTION Florida Department of Business -and Professional. Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Stieet:. `qQ �j C� Permit Office: ST. LUCIE COUNTY. City, State, Zip: FT. -PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9.. Wall Ty0es.(1432.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ftz b., Frame - Wood, Adjacent R=11.0 208.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a Worst case? Yes 10. Ceiling. Types (1793.0 sqft.) Insulation . ; .Area. a. Under Attic (Vented) R=30.0 1753.00 ftz 6. Conditioned floor area above grade (ftz) 1753 b. Knee Wall (Vented) R=19.0 30.00 ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ft z 1.1. Ducts R ftz 7. Windows(151.4 sgft:) Description Area a: Sup: Attic, Ret: Attic, AH: Attic . 6 175 a. U-Factor: Sgl, U=1:04 1 I i m ftz SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ftz 12. Cooling systems kBtu/hr Efficiency , SHGC: SHGC=0.27 a. Central Unit -34.8 SEER:15:00 c. U-Factor: N/A ftz SHGC; 13. Heating systems kBtu/hr Efficiency d. U.-Factor: N/A ftz a. Electric Heat Pump 34.8 HSPF:8.50 SHGC:. Area Weighted Average Overhang Depth: 2:850 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1753.0 sgft.) Insulation . Area a. Electric Cap: : 40.gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ftz. b. Conservation features 0.970 b. N/A R= ftz None c. N/A R= ftz 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.20 ��� S Total Baseline Loads: 53.92 -hereby certify that the plans and -specifications covered by this calculation are in compliance with the Florida Energy Review of the plans and by this �5 specifications covered .Code. calculation indicates compliance �,,,°' -_�a ��.`�s► with the Florida Energy Code. 'PREPARED BY: Before construction is completed DATE: 1-9-20 this building will be inspected for ' �i. _4 compliance with Section 553.908 I.hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code�'jq" OWNER/A�E,�IT: BUILDING OFFICIAL: DATE` �, 1•� DATE: - Compliance requires certification by the air handier unit manufacturer that the air'handlereinclosure qualifies as. certified factory-aealed in accordance with 11403A2:1. - Compliance requires an. Air Barrierand Insulation Inspection Checklist in accordancg6apdi ffeaject requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (I140 B1J �y CODE COMPLOA6�C-E ST. LUCIE COMO. BOCC 1/8/2020 4:43 PM EnergyGauge® USA 6.0'.02.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms:. 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: #'of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle:. 0 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.6 % 2:5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES. Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished -Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No' 0 1 No: Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes 'Yes Yes 5 LAUDRY 36 2W No 0 1 No Yes Yes 6 BEDROOM 2 180 1440, No 0 1 1 Yes Yes Yes 7 DINING/GREAT.R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes '10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 -No 0 1 Yes Yes Yes .12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value . Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio .MASTER BEDRO .37 ft . .0 224 ftZ _ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH• 8 ft 0 56 ft2 __ 0 1 0 4 Slab -On -Grade Ed9e Insulatio M. BATH 7 ft 0 .61 ft2 _v 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1. ft 0 36 ft2 0 1 0 1/8/2020 4:43 PM , EnergyGauge® USA 6.0.02 (Rev. ,l) - FlaRes2017. FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0 7.SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588'ft2 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0_ 50 ft2 0 1 0 1.0SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ____ 0 1 0 11Slab-On-Grade Edge Insulatio FOYER .9 ft 0 92 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ____ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA. Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.4 No 0:9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood . 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 W 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 - '30 Blown 180 ft2 0.11 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 . Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Cavity Width Space. Height Sheathing Framing Solar Below 0 1. E Exterior Concrete Block - Int InsbiIASTER'BE 4.1 16 0 8 0• 128.0 ft2 0 0 6.3 0 2 W Exterior Concrete Block - Int Ins89ASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 . 3 S Exterior Concrete Block - Int InsiMASTER BE • 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3. of 6 FORM R405-2017 INPUT. SUMMARY: CHECKLIST REPdRT WALLS Adjacent Wall lypp SpaceIn Cavity' Width Height Area Sheathing' Framing " Solar Below Gradeo 4 E Exterior Concrete Block- Int InsiNASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 E Exterior Concrete Block - Int Instil M. BATH 4.1 7 0 8 0 56.0 ftz 0 0 0.3 0 6 E Exterior Concrete Block - Int InsBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 7 S Exterior Concrete Block - Int lns(A1NING/GRE 4.1 30 0 8 0 240.0 ftz 0 0 0.3 0 8 W Exterior Concrete Block - Int Ins(DINING/GRE 4.1, 20 0 8 0 160.0 W 0 0 0.3 0 _ 9 W Exterior Concrete Block - Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 10 E Exterior Concrete Block- Int Instil BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 _ 11 N Exterior Concrete Block - Int Insul FOYER, 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 12 N Exterior _ Concrete Block -_ Int Insul FOYER .4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _ 13 W Exterior Concrete Block - Int InsE1EDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 14 N Exterior Concrete Block - Int InsBIEDROOM 3 4A ' 1 ' 0 8 0 &0 ft2 0 0. . 0.3 0 _ 15 N Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Ornt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .32 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered:orientation: _> changed to Worst Case. / Wall Overhang V # Ornt ID frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 3 Metal Low-E Single Yes 1.04 0.29 N 32.4 ft2' 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 E 5 Metal Low E Single Yes 1.04 0.29 N 6.9 ft2 1 ft0 in 1 ft 6 in None None 3 E 6 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft2 , 1 ft 0 in 1 ft 5 in None None 4 S 7. Metal Low E Single Yes 1.04 0.29 N 39.8 ft2 1 ft 0 in 1 ft 5 in None None 5 W 8 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 5 in None None 6 W 13 Metal Low E Single Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in . Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall`Pedmeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION . # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 6416 120:66 .0881 5 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPnRT HEATING SYSTEM' # System Type 'Subtype Speed Efficiency Capacity Block Ducts 1 Electric'Heat Pump/ Split Singl. HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 .40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftZ DUCTS --- Supply -- ---- Return -- Air CFM 25. CFM25 HVAC # # Location R=Value Area Location Area Leakage Type. Handler TOT OUT QN RLF Heat _ Cool 1 Attic 6 . 175 ft? Attic 55 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans:' Cooling Jan Feb Heating Jan Feb Ventin Mar Mar A r Apr Jun Jul X Au I May Junjxj Ma rj Jul AuI X Se Sep Oct . Oct Nov Nov Dec Dec Jan Feb Mar A r [ l Ma Jun Jul [ Aug L [ Se Oct X Nov . Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4, 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 '78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68• 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66. 66 68 68 68 68 .68 68 68 PM' 68 68 68 68 68 68 68 68 68 68 .66 66 MASS Mass Type. Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ftz 0 ft 0.3, BEDROOM Default(8 lbs/sq.ft. ftz ft 0.3 WIC Default(8 lbs/sq.ft. ftz ft 0.3 M. BATH Default(8 lbs/sq.ft. ftz ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ftz It 0.3 BATH Default(8 lbs/sqA. ftZ ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ftz ft 0.3 ENTRY Default(8 lbs/sq.ft. ft? ft 0.3 LAUNDRY 1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT MASS Mass Type Area Thickness. Furniture Fraction 'Space Default 8 lbs/s ., ft2 ft 0:3 GREAT/DINING 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE:402.4.1.1 AIR BARRIERAND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE.WINDSOR•IMPACT Builder Name: WYNNE DEVELOPMENT Street:. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: v Owner: Jurisdiction: w Design Location: FL, Fort Pierce 0 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building:envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a. continuous. air barrier. not be used as a sealing material. Breaks or joints in air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit air the insulation and any gaps s in the air barrier.sfiall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall'be sealed. Cavities within corners and headers of frame walls The junction of the top plate -and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between windowldoor jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier: Rim joists shall be insulated. Floors : .The air barrier shall be installed at any exposed edge of Floor framing: cavity insulation shall be installed.to (including . insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends fromthe. bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations', and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Ds. Recessed lighting Recessed light fixtures Installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to. fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend bf-h nd piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls. adjacent'to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall. be installed behind.elpetricalor communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub=floor or drywall. Concealed When required to be sealed, concealed fire sprinklers:shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire spOnkler cover plates an d walls or cewlings. a. in addition, inspection of log walls snail tie-in accordance with the provisions of IGG-400. 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. I)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 r 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED. ENERGY PERFORMANCE INDEX* = 97 The lower the Energy P.erforinance Index,.the more ;efficient the home. . 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level ay Supply ducts R 6.0 2. Single-family.or multiple -family 2. Sinale-family b) Return :ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 5. Is this a worst case? (yes/no) 5. Yes 6.. Conditioned floor area (sq. ft.) 6. 1753 '7. Windows, type and area . a) U-factor:(weighted average) 7a. 1.056 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 c) Area 7c. 151.4 8. Skylights a) U-factor:(weighted average.) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b.. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R=value) c) Concrete; raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2.. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R=value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 1OA1. ' 1OA2. '' 4.1 106.1: '11.0 1062. 11a. 30.0 11.b: 11c. 19.0 11 d. No 13. Cooling system: Capacity 34.8 a) Split system, SEER 15.0 b) tingle package SEER c) Ground/water source SEER/COP ' d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 34.8. a). Split- system heat pump • HSPF . 8.5 b) Single package heat pump- HSPF . c) Electric resistance I COP d) Gas furnace, natural'gas. AFUE e) Gas furnace., LPG AFUE f) Other ' 15. Water heating system a) Electric resistance EF 0.97 b) Gas`fired; natural gas EF c) Gas fired,. LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g): Other 16. HVAC creditsclaimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat Yes *Label required bySection R303.1.3 of the Florida. Building Code, Energy Conservation, .if not DEFAULT I certify that this home has complied with the Florida Building. Code, Energy Conservation, through the above energy saving featuresr which: will be installed (or exceeded): in. this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features.' Builder Signature: Date: Address of -New Home: `� Q:C--Cr%, City/FL Zip:: FT. PIERCE: FL � LA 1/8/2020 4:43:52 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2011 FBC 6th Edition (2017) Compliant Software Page 1 of 1