HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA. ENERGY EFFICIENCY CODE FOR BUILDING. CONSTRUCTION
Florida Department of Business -and Professional. Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
Stieet:. `qQ �j C�
Permit Office: ST. LUCIE COUNTY.
City, State, Zip: FT. -PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9.. Wall Ty0es.(1432.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ftz
b., Frame - Wood, Adjacent
R=11.0 208.00 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftz
5. Is this a Worst case? Yes
10. Ceiling. Types (1793.0 sqft.)
Insulation . ; .Area.
a. Under Attic (Vented)
R=30.0 1753.00 ftz
6. Conditioned floor area above grade (ftz) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ft z
1.1. Ducts
R ftz
7. Windows(151.4 sgft:) Description Area
a: Sup: Attic, Ret: Attic, AH: Attic
.
6 175
a. U-Factor: Sgl, U=1:04 1 I i m ftz
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ftz
12. Cooling systems
kBtu/hr Efficiency ,
SHGC: SHGC=0.27
a. Central Unit
-34.8 SEER:15:00
c. U-Factor: N/A ftz
SHGC;
13. Heating systems
kBtu/hr Efficiency
d. U.-Factor: N/A ftz
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:.
Area Weighted Average Overhang Depth: 2:850 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1753.0 sgft.) Insulation . Area
a. Electric
Cap:
: 40.gallons
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ftz.
b. Conservation features
0.970
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.20
��� S
Total Baseline Loads: 53.92
-hereby certify that the plans and -specifications covered by
this calculation are in compliance with the Florida Energy
Review of the plans and
by this
�5
specifications covered
.Code.
calculation indicates compliance
�,,,°' -_�a ��.`�s►
with the Florida Energy Code.
'PREPARED BY:
Before construction is completed
DATE: 1-9-20
this building will be inspected for
'
�i. _4
compliance with Section 553.908
I.hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code�'jq"
OWNER/A�E,�IT:
BUILDING OFFICIAL:
DATE` �, 1•�
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air'handlereinclosure qualifies as.
certified factory-aealed in accordance with 11403A2:1.
- Compliance requires an. Air Barrierand Insulation Inspection Checklist in accordancg6apdi ffeaject requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (I140 B1J �y
CODE COMPLOA6�C-E
ST. LUCIE COMO.
BOCC
1/8/2020 4:43 PM EnergyGauge® USA 6.0'.02.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms:. 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
#'of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle:. 0
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.6 % 2:5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES.
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished -Cooled
Heated
1 MASTER BEDROO
224 1792 No 0
1
1
Yes
Yes
Yes
2 WIC
63 504 No' 0
1
No:
Yes
Yes
3 MASTER BATH
56 448 No 0
1
Yes
Yes
Yes
4 M.BATH
61 488 No 0
1
Yes
'Yes
Yes
5 LAUDRY
36 2W No 0
1
No
Yes
Yes
6 BEDROOM 2
180 1440, No 0
1
1
Yes
Yes
Yes
7 DINING/GREAT.R
588 4704 No 2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes 0
1
Yes
Yes
Yes
9 BATH
50 400 No 0
1
Yes
Yes
Yes
'10 HALL
25 200 No 0
1
No
Yes
Yes
11 FOYER
92 736 -No 0
1
Yes
Yes
Yes
.12 BEDROOM 3
169 1352 No 0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value .
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
.MASTER BEDRO .37 ft . .0
224 ftZ
_
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
____
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH• 8 ft 0
56 ft2
__
0 1
0
4 Slab -On -Grade Ed9e Insulatio
M. BATH 7 ft 0
.61 ft2
_v
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1. ft 0
36 ft2
0 1
0
1/8/2020 4:43 PM , EnergyGauge® USA 6.0.02 (Rev. ,l) - FlaRes2017. FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value Tile Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
____
0 1 0
7.SIab-On-Grade Edge Insulatio
DINING/GREAT 50 ft
0
588'ft2
0 1 0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift
0
209 ft2
0 1 0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0_
50 ft2
0 1 0
1.0SIab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft2
____
0 1 0
11Slab-On-Grade Edge Insulatio
FOYER .9 ft
0
92 ft2
____
0 1 0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft2
____
0 1 0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA. Emitt
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1847 ft2
0 ft2
Light
N
0.4
No 0:9
No 0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood .
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 W
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2 -
'30
Blown
180 ft2
0.11
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30 .
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Cavity Width
Space.
Height
Sheathing Framing Solar Below
0
1.
E Exterior Concrete Block - Int InsbiIASTER'BE 4.1
16
0 8
0•
128.0 ft2
0 0
6.3
0
2
W Exterior Concrete Block - Int Ins89ASTER BE 4.1 7
0 8
0
56.0 ft2
0 0
0.3
0 .
3
S Exterior Concrete Block - Int InsiMASTER BE • 4.1
14
0 8
0
112.0 ft2
0 0
0.3
0
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3. of 6
FORM R405-2017 INPUT. SUMMARY: CHECKLIST REPdRT
WALLS
Adjacent
Wall lypp SpaceIn
Cavity' Width
Height
Area
Sheathing' Framing "
Solar Below
Gradeo
4
E
Exterior
Concrete Block- Int InsiNASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
5
E
Exterior
Concrete Block - Int Instil M. BATH
4.1 7
0
8 0
56.0 ftz
0
0
0.3
0
6
E
Exterior
Concrete Block - Int InsBEDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
7
S
Exterior
Concrete Block - Int lns(A1NING/GRE
4.1 30
0
8 0
240.0 ftz
0
0
0.3
0
8
W
Exterior
Concrete Block - Int Ins(DINING/GRE
4.1, 20
0
8 0
160.0 W
0
0
0.3
0
_ 9
W
Exterior
Concrete Block - Int InsulKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
10
E
Exterior
Concrete Block- Int Instil BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
_ 11
N
Exterior
Concrete Block - Int Insul FOYER,
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
12
N
Exterior
_ Concrete Block -_ Int Insul FOYER
.4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
_ 13
W
Exterior
Concrete Block - Int InsE1EDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block - Int InsBIEDROOM 3
4A ' 1 '
0
8 0
&0 ft2
0
0.
. 0.3
0
_ 15
N
Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U Value
Width
Height
Area
Ft In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered:orientation: _> changed to Worst Case.
/
Wall
Overhang
V
#
Ornt ID
frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S 3
Metal Low-E Single Yes
1.04 0.29
N
32.4 ft2'
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior 5
2
E 5
Metal Low E Single Yes
1.04 0.29
N
6.9 ft2
1 ft0 in
1 ft 6 in
None
None
3
E 6
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft2
, 1 ft 0 in
1 ft 5 in
None
None
4
S 7.
Metal Low E Single Yes
1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 5 in
None
None
5
W 8
Metal Low-E Single Yes
1.11 0.27
N
40.0 ft2
8 ft 0 in
1 ft 5 in
None
None
6
W 13
Metal Low E Single Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in .
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall`Pedmeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
.
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254 1168.7 6416
120:66
.0881
5
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPnRT
HEATING SYSTEM'
# System Type
'Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric'Heat Pump/
Split
Singl. HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtu/hr cfm 0.85
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 .40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ftZ
DUCTS
--- Supply --
---- Return -- Air
CFM 25.
CFM25
HVAC #
# Location R=Value Area
Location
Area Leakage Type. Handler
TOT
OUT QN
RLF
Heat _ Cool
1 Attic
6 . 175 ft?
Attic
55 ftz Default Leakage Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:'
Cooling Jan Feb
Heating Jan Feb
Ventin
Mar
Mar
A r
Apr
Jun Jul X Au
I May Junjxj
Ma rj
Jul AuI
X Se
Sep
Oct .
Oct
Nov
Nov
Dec
Dec
Jan Feb
Mar
A r [
l
Ma Jun Jul [ Aug
L
[ Se
Oct
X Nov
. Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3
4, 5 6 7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78 78 78 78
78
80 80
80
80
PM
80
80
78
78 78 78 78
78
78 '78
78
78
Cooling (WEH) AM
78
78
78
78 78 78 78
78
78 78
78
78
PM
78
78
78
78 78 78 78
78
78 78
78
78
Heating (WD) AM
66
66
66
66 66 68 68
68
68 68
68•
68
PM
68
68
68
68 68 68 68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66. 66 68 68
68
68 .68
68
68
PM'
68
68
68
68 68 68 68
68
68 68
.66
66
MASS
Mass Type.
Area
Thickness Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ftz
0 ft 0.3,
BEDROOM
Default(8 lbs/sq.ft.
ftz
ft 0.3
WIC
Default(8 lbs/sq.ft.
ftz
ft 0.3
M. BATH
Default(8 lbs/sq.ft.
ftz
ft 0.3
KITCHEN
Default(8 Ibs/sq.ft.
ftz
It 0.3
BATH
Default(8 lbs/sqA.
ftZ
ft 0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ftz
ft 0.3
ENTRY
Default(8 lbs/sq.ft.
ft?
ft 0.3
LAUNDRY
1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT
MASS
Mass Type Area Thickness. Furniture Fraction 'Space
Default 8 lbs/s ., ft2 ft 0:3 GREAT/DINING
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE:402.4.1.1
AIR BARRIERAND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE.WINDSOR•IMPACT Builder Name: WYNNE DEVELOPMENT
Street:. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
v
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
0
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building:envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a. continuous. air barrier.
not be used as a sealing material.
Breaks or joints in air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
air
the insulation and any gaps
s in the air barrier.sfiall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall'be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate -and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between windowldoor jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier:
Rim joists shall be insulated.
Floors :
.The air barrier shall be installed at any exposed edge of
Floor framing: cavity insulation shall be installed.to
(including .
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends fromthe.
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations', and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Ds.
Recessed lighting
Recessed light fixtures Installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to. fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend bf-h nd piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls. adjacent'to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall. be installed behind.elpetricalor communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub=floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers:shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire spOnkler cover plates an d walls or cewlings.
a. in addition, inspection of log walls snail tie-in accordance with the provisions of IGG-400.
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. I)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
r
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED. ENERGY PERFORMANCE INDEX* = 97
The lower the Energy P.erforinance Index,.the more ;efficient the home. .
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
ay Supply ducts R 6.0
2. Single-family.or multiple -family 2. Sinale-family b) Return :ducts R 6.0
c) AHU location Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3
5. Is this a worst case? (yes/no) 5. Yes
6.. Conditioned floor area (sq. ft.) 6. 1753
'7. Windows, type and area .
a) U-factor:(weighted average) 7a. 1.056
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285
c) Area 7c. 151.4
8. Skylights
a) U-factor:(weighted average.) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b.. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R=value)
c) Concrete; raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2.. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R=value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
1OA1. '
1OA2. '' 4.1
106.1: '11.0
1062.
11a. 30.0
11.b:
11c. 19.0
11 d. No
13. Cooling system: Capacity 34.8
a) Split system, SEER 15.0
b) tingle package SEER
c) Ground/water source SEER/COP '
d) Room unit/PTAC EER
e) Other
14. Heating system: Capacity 34.8.
a). Split- system heat pump • HSPF . 8.5
b) Single package heat pump- HSPF .
c) Electric resistance I COP
d) Gas furnace, natural'gas. AFUE
e) Gas furnace., LPG AFUE
f) Other '
15. Water heating system
a) Electric resistance EF 0.97
b) Gas`fired; natural gas EF
c) Gas fired,. LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g): Other
16. HVAC creditsclaimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required bySection R303.1.3 of the Florida. Building Code, Energy Conservation, .if not DEFAULT
I certify that this home has complied with the Florida Building. Code, Energy Conservation, through the above energy
saving featuresr which: will be installed (or exceeded): in. this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.'
Builder Signature: Date:
Address of -New Home: `� Q:C--Cr%, City/FL Zip:: FT. PIERCE: FL � LA
1/8/2020 4:43:52 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2011 FBC 6th Edition (2017) Compliant Software Page 1 of 1