HomeMy WebLinkAboutTrussLumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. •� MiTek � RE: Q58598 - REAR ADDITION MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: MATT HOLT Project Name: 127 ESTIA LN Model: Tampa, FL 33610-4115 Lot/Block: Subdivision: Address: 127 ESTIA LN City: ST LUCIE COUNTY State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: . License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.3 Wind Code: ASCE 7-10 Wind Speed: 170 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 2 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T21163852 A 8/31 /20 2 T21163853 GEA 8/31/20 This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2021. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. `%�OPCtUIN VFW ii GENE' • ��'�. No 68182 O:• /STATE OF ♦ �• Joaquin Velez PE No.68182 MiTek USA, Inc. FL Gert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: August 31,2020 Velez, Joaquin 1 of 1 Job Truss Truss Type r Qty Ply REAR ADDITION T21163852 Q58598 A Common 9 1 Job Reference (optional) �riamuurs i toss, Inc., MR rleroe, rL 6.3Ju s Jul ZZ ZUZU mi I eK Inaustfles, Inc. Man Aug J1 UUA 4:S6 ZUZU rage 1 ID:UK9c61 Is1f4GtL25MctiuSyrlod-LvW3svOMRAIIHwAQYbYwYNGZjMtcVBgG4Usi6LyiN IR 1-00-8-8 9-0-10 13-5-2 18-513 23-5-7 274-4-7-9-14 3:2K" 3-7-0 --0-2 5-0-3 4-0-10 9-0-10 4-4-7 5-0-8 1.25 12' 2x3'-- 3x4 = 4x4 = Sx6 WB = 5 28 6 3x4 7 Scale = 1:55.6 1 I06 a 16 15 - 14 13 12 3x6 = 3x5 = 3x4 = 5x8 MT18HS = 3x8 = 5x6 NB = 3x4 = 6x8 I I LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 1-4-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TPI2014 CSI. TC 0.57 BC 0.92 WB 0.60 Matrix -Ms DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in (loc) I/deft L/d -0.75 14-16 >522 360 -1.39 14716 >281 240 0.12 10 n/a n/a 1.13 14-16 >346 240 PLATES MT20 MT18HS Weight: 139 lb GRIP 2441190 244/190 FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-8-6 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 SLIDER Right 2x4 SP No.3 -x 2-6-0 REACTIONS. (size) 10=0-5-8, 2=0-3-8 Max Harz 2=41(LC 8) Max Uplift 10=-555(LC 12), 2=565(LC 12) Max Grav 10=833(LC 1), 2=848(LC 1) FORCES. , (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5217/3898, 3-5=-4876/3556, 5-6=3322/2463, 6-7=3326/2464, 7-8=3327/2429, 8-10=-3002/2264 BOT CHORD 2-16=-3864/5181, 14-16=-3206/4305, 12-14=-2714/3623, 10-12=2208/2954 WEBS 3-16=-396/410, 5-14=-1080/854, 6-14=-317/513, 7-14=483/366, 7-12=-353/380, 8-12=-197/399, 5-16=-327/636 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=33ft; eave=4ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-1-0-11 to 2-2-6, Interior(1) 2-2-6 to 33-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. This Item has been 5) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide electronically signed and • will fit between the bottom chord and any other members. sealed by Velez, Joaquin, PE 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) using a Digital Signature. 10=555,2=565. Printed copies of this - document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33810 Date: August 31,2020 ®WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUI P11 Duality Criteria, DSB-89 and BCSI.Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type 1 Qty Ply REAR ADDITION T21163853 Q58598 GEA Common Supported Gable 1 1 Job Reference o tional linamDefs I russ, Inc., t-on rlefce, t-L C.3JU s JUI ZZ Zuzu .,, eK nausmes, no. Man Aug ai ut ri i:oa zuzu rage I ID: UK9c61 Ist f4GtL25MctiuSyrlod-g64R4FP_CTQcv4lc6J395apo5m OvElEPJ8cGeQyiNIQ 8-7-0 18-5-4 28-3-8 32 6-8 33-7- 0, 8 8-7-0 9-10-4 9-10-4 4-3-0 0 W8 Scale = 1:55.7 1.25 12 5x6 = 5 306 4x4 = 7 8 9 10 11 28 27 26 2524 23 22 21 20 19 18 17 16 3x6 = 5x6 = LOADING (psf) SPACING- 1-4-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.28 Vert(LL) 0.00 15 n/r 120 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.21 Vert(CT) 0.00 15 n/r 90 BCLL 0.0 Rep Stress Incr YES WS 0.14 Horz(CT) 0.00 16 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-S Weight: 118 Ib FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP M 30 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 32-3-0. (lb) - Max Horz 2=41(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 22, 23, 24, 21, 20, 19, 18 except 16=-130(LC 12), 2=-168(LC 12), 26=-104(LC 8), 27=-170(LC 21), 28=313(LC 8). 17=-107(LC 9) Max Grav All reactions 250lb or less at joint(s) 16, 2, 22, 23, 24. 26, 27, 21, 20, 19, 18, 17 except 28=509(LC 21) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 3-28=-349/464 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=33ft; eave=2ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corrl-1-0-11 to 2-2-6, Exterior(2) 2-2-6 to 33-7-3 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. This Item has been Z) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide electronically signed and will fit between the bottom chord and any other members. Sealed by Velez, Joaquin, PE 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 23, 24, 21, 20, using a Digital Signature. 19,18 except Qt=lb) 16=130, 2=168, 26=104, 27=170, 28=313,17=107. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Ino. FL Cert 6634 8904 Parke East Blvd. Tampa FL 33610 Date: August 31,2020 ®WARNING - Verily design parameters and'READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19=20 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify, the applicability of design parameters and propedy Incorporate this design into the overall �t A building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Itl10Tek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ' ANSUTP11 Quality Criteda, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0'�16 r - -I- For 4 x 2 orientation, locate plates 0- '!+c' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. ' Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 3 TOP CHORDS C1-2 C2-3 WEBS c3ro 4 tY m � ❑ O= U d d 0 caa cs s 0 BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311. ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek® All Rights Reserved MiTek® MiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020 ® General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSUTPI 1. - 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or pur ins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly staled.