HomeMy WebLinkAboutEnergy CodeProjectName: WYNNETHE GRAND CARLTON IMPACT
BuilderName: WYNNE BUILDING COPR.
-- ,
Street: �v� 'gu q
Permit Office: .ST.LUCIE;000NTY
-
City, State, Zip:. " " FT.:PIERCE , FL ,.
PermitNumber:
Owner: WYNNE BUILDING CROP
.Jurisdiction: ST: LUCIE'COUNTY
DesignLocation: , " FL, Fort Pierce.
County: - St. Lucie (Florida Climate Zone .2) ".
1.: New construction or existing.." New.(From Plans) .. "
9. Wall Types (1442.0 sgft.) .. '
Insulation .":.Area.
2. Single family or multipie family- ., Single-family -
a: Concrete Block- Int Insul, Exterior _
13=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
- R=11.0 - .192.00 ftz
3. Number of units, if multiple family 1 : "
c. N/A
_
R= ft2
4. "Number of Bedrooms 2
d. N/A
R_
5:. Is this a worst case? Yes
10..Ceiling Types . (1476.0. sgft:) .:..
Insulation .":.Area.- . .
a. Under Attic (Vented)
R=30.0.' 1446.00 ft2. "
6. Conditioned floor area above grade (ft2). 1446
b. Knee Wall (Vented)
. R=19.0 30.00 ft2.:.
Conditioned floorareabelowgrade(ft2) 0
c. N/A _
R= 12
1.1. Ducts
R.. 02' . .
I
7: VVindows(141 3 sgft.) ." Description Area
a: Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U=Factor:" SgI,U=1.11 40.00 ft2"
12. Cooling systems
kBtu/hr. Efficiency ..
SHGC:. " .. SHGC=0.27 .
a. Central Unit
34.8 . SEER:15.'00. "
c. U,Factor: N/A " .... ft2
SHGC;
13. Heatingsystems
kBtu%hr . Efficiiency
d. U-Factor: N/A ft2
a. Electric Heat Pump .
34.8 HSPF:8.5.0
SHGC:".
Area Weighted Average Overhang Depth: ": 3.832-ft.:
Area Weighted Average SHGC: ", 0:284 "."
14.,Hot watersystems, :.•.
a; Electric
Cap:40_gallons .;
8". Floor Types ' (1445.5" sgft.) Insulation .'Area
EF: 0.970 .
•.a.Slab-On-Grade Edge Insulation . R=0.0 1445.5oft2
b. Conservation features
b. N/A . R= ft2.
None
c. N/A . R= ft2.
15 Credits ...
Pstat ... .
Glass/Floor Area: 0.098 - Total Proposed. Modified Loads:. 47.50
PASS
Total Baseline Loads: .48.09.
f hereby certify that the plans and specifications covered by
Review of the plans and^fi�T
this calculation are in .compliance with the. Florida Energy-
specifications covered. by this
Code.
.calculation. indicates.compliance
with the Florida "Energy Code..
PREPARED" BY:
Before construction is: completed
` ;
DATE: 1-9-20
this building will be'inspected for
compliance with Section 551908
O."-
hereby"certi that this buildin , as designed, is in compliance
fY 9 9 P
Florida. Statutes...
with the Florida Energy C. -....
G'{i�
•OWNER/ GEN
BUILDING OFFICIAL
DATE: '��'� .
DATE:
..:Compliance requires certification by.the.air handier unit manufacturer that the ikj� n r enclosure qualifies as:'
certified factory -sealed" in accordance with R403.3.2.1..
Compliance requires an Air Barrier and Insulation In Checklist in'accordance with R402.4.1:1 and this'project requires,
an envelope leakage -test report with envelope leakage no greater.than 7:00 ACH50. (R402.4.1:2).
REVIEW
�:®�
CODE COMPL9ANCY
�ST..LUCIE. COUNT .
" 1/8/2020 4:18 P.M EnergyGauge® USA 6:0.02 (Rev:1) - FlaRes2017 FBC 6th Edition 017) Compli Page 1.'of 5
r -
C
FORM R405-2017 INPUT. SUMMARY. GIIEGKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARLT Bedrooms: 2
Address Type:
StreetAddress
Building Type: User
:Cond'itionedArea: 1446
Lot#
' OwnerName; WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
BuilderName:... WYNNE BUILDING COPR. RotateAngle:. 180
Street:, .
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County:.
St. Lucie .
Jurisdiction:.'ST.:LUCIECOUNTY.
Whole House Fan: No
City,State,'Z'ip:
FT. PIERCE:,.
FamilyType: Single-family
FL,
New/Existing: New (From_Plans)
Comment:. .
CLIMATE
/
Design Temp
Int Design Temp Heating
Design DailyTemp
V DesignLocation
TMY Site 97.5%- 2:5%
Winter
Summer Degree Days Moisture
Range-
FL; Fort Pierce FL VERO BEACH_MUNI 39 -90
70
75- 299
62-
Low
BLOCKS
Number Name" . - .
'Area 'Volume : .
1 Entire House
1446 11568
SPACES.
Number- _ : Name:
Area. Volume- Kitchen Occupants:
:Bedrooms
InfilID Finished Cooled
:Heated
1 BEDROOM
301- 2408 No 0
1
1 Yes;
Yes
Yes
2: : WIC :.
63. 504 No 0
1 No.
Yes
:Yes'.
3 M..BATH
56 448 No 0
1 Yes
Yes.
Yes;'
4 KITCHEN
192 - 1536 Yes 0
1 No.
Yes
Yes
5 BATH _
45 360- No 0
1 Yes •
Yes - -
Yes
6. .BEDROOM 2 :
204- 1632 No- 0
1
1. : Yes
Yes..
Yes.
.7 -ENTRY. .55
- 440. No 0.
1 Yes
-Yes
Yes
8 LAUNDRY
42 336. No 0
1 Yes
Yes
Yes
9 GREAT/DINING :
4$8 � 3904 No 0
1 Yes
Yes
Yes
FLOORS
# FloorType -
Space: Perimeter - PerimeterR-Value
Area
JolstR-Value'
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM _ 52'ft 0.
301 ft2
_ :_.
0 1.
0
2.Slab-On-Grade Edge Insulation
WIC 1 ft 0
63ft2
__:_
0 1
0.
3Slab-On-Grade Edge Insulation
M. BATH 8 ft 0
56 ft2
_
0,: 1
0
4 Slab -On -Grade Edge lnsulation
KITCHEN 1:ft 0
192 ft?.
___
0 . _ 1
: 0
5 Slab -On -Grade Edge Insulation
.. BATH 5 ft. 0
45 ft2 ..
____
-0.: 4..
0.
.. . .... .. .... .. ... ..
.6 Slab -On -Grade Edgelnsulation
....
'BEDROOM 2: . 32.2It _ _ .: `, 0' . .; .
203.5 ft2
__:_
0. ., ",1
.0 . .
7:Slab-On-Grade Edge Insulation
ENTRY 7 ff 0
55 ft2
0 1
0:
FORM R405-2017 -INPUT 5UMMAKY:GHEGKL15T REPORT
FLOORS .
# FloorType_ `. Space : Perimeter PerimeterR-Value
Area
JoistR-Value:
Tile Wood Carpet- -
8Slab-On-GradeEdge Insulation LAUNDRY - 6 ft
= '0
42 ft2
0
1.-
0
9.Slab-On-Grade Edge Insulation GREAT/DINING 46 ft
0
48812
____
0
1
0.
ROOF
/ Roof _
Gable
Roof
Rad _
Solar.
SA Emitt
Emitt _Deck_
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
-Tested Insul.
' (deg)
1 ; Gable WShed Metal 1524 ft2
240 ft2
Light
N
0.6'
No - 09
No ; 0
18.4_
ATTIC
�_ .. # Type . .
-Area
Ventilation:
Vent Ratio (1 in)
RBS
IRCC,
1 Full attic Vented
150
1446 ft2.
N
N
CEILING
# Ceiling Type Space
R-Value
In Type
Area
Framing Frac
Truss Type .
1 UnderAttic(Vented) BEDROOM
30
Blown
301 ft'
0.1
Wood-
2 UnderAttic(Vented) WIC
30
Blown:
-
63;ft2 :
0.1
Wood
3 UnderAttic(Vented) M. BATH
.30
Blown
56 ft2
0.1
Wood
- 4 UnderAttic (Vented) KITCHEN
30
Blown
-
192 ft2 ,
.0.1
Wood .
5 UnderAttic(Vented) BATH.
30
Blown
45ft2
0.1
Wood
6 ,. _ UnderAttic (Vented) BEDROOM 2 .
30.:
Blown
204 ft' .
0.1
Wood .
7 Under Attic (Vented) ENTRY.
'30
Blown
55:ft2
0.1 - :
Wood
8. UnderAttic(Vented) LAUNDRY
30
Blown
.42ft2.
0.1
Wood.
9- UnderAttic (Vented) GREAT/DINING
30'
Blown
.
488 ft2
011 .
Wood
-
10: Knee Wall (Vented) GREAT/DINING
. 19
Blown
-
30 ft2
0.11
1Wood.
WALLS
.
Adjacent Space. Cavity Width RA/Wile"
.Et
Height
A�ea
Sheathing Framing Solar .
13-Vaille- Fran .0
Below
1 NE=>SW Exterior Concrete Block - Int Insul BEDROOM.:
4.1 10
0.: 8
0 ,:
80.0 ft2.
0 .:
0
0.4
0
2: SW=>NE Exterior Concrete Block- Int Insul BEDROOM
:4.1 28
0 8
0
224.0 ft2
0
0'
0.4:
0 .
3 NW=>SE Exterior Concrete Block= Int Insul BEDROOM
4.1 1.4 '
0 8
_ - 0 _
112.0 ft'
_ 0 ;
0
0.4
0
4. SW=>NE Exterior Concrete Block- Int Insul M.-BATH -
4.1 8
0 8
.0
64.0 ft2.
0
0
0.4.
0.
5 NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0.
40.0 ft2.
0.
-0
0.4
0
6 NE=>SW Exterior. Concrete Block- Int lnsuBEDROOM 2
4.1 16
0 8
0.-
128.0 ft?
0
0
0.4
.0
7 SE=>NW.Exterior. Concrete Block - Int insuBEbROOM2
4.1 10
0 .8.
.0
86.0.,W
0-
0
.6.4..
0..
8 S=>N 'Exterior Concrete Block- Int lnsuBEDROOM 2.
4A ' 4
3 8
0
34.0 ft-'
0'
0
0.4
0
9 SW=>NE Exterior Concrete Block - Int lnsuBEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4-
0
10 SE=>NW Exterior: Concrete Black - Int Insul ENTRY : ;
4.1 6 ::
0 8 ::
- 0 :
48.0 ft2
0':
0
0.4
0
11 S1N=>NE Exterior . Concrete Block: lnt Insul ENTRY
4.1 1:
0 : 8
0
U ft'
0
-0
'0.4
0
-12 SW=>NE Exterior Concrete.Block - lntlnsul LAUNDRY'
4.1. -.6
0:. 8
0
48.0ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block- Int InsUKiREAT/DINI.
4.1 26
0 8
0.
208A ft2.
0.,
0
0.4' , .
0
14 NW=>.SE Exterior Concrete Block= Int InsulGREAT/DINI
4.1 20
0 8.
0
160.0.ft2
0
0
.0.4
0
1/8/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev:1) - FlaRes2017.FBC 6th EditioM2017) CompliantSoftware •:
Page 3 of 5:
PrnPKA Rangy.-,)n17 INPUT SUMMARY CHECKLIST RFPC)RT
WALLS
Adjacent
Space Cavity Width
Height Sheathing Framing Solar Below
15 N=>S Garage Frame -Wood
KITCHEN 11 24 8
192:0ft2" 0.23 0.4
0
DOORS
# Ornt
DoorType
Space. Storms
U-Value Width Height
Ft In Ft In
Area ".
1 SE=>NW
Insulated
ENTRY None
39 3 . 1 6 8
20.6 ft2
-WINDOWS
Orientation shown is.the entered -orientation =>) than ed to Worst Case.
Wall
# Ornt . ID. Frame
- Panes .
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation IntShade
Screening
1 NW=>SE 3 Metal
2. SW=>NE-4 ,Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal •
-.Low-ESingle
Low-ESingle.
.Low-ESingle
Low-ESingle
• Low-ESingle
Yes 1.04 0.29 Y
Yes; .1.04. 0.29 Y
Yes 1.04 0.29 Y
. Yes 1.04 '0.29 Y
Yes 1.11 0.27 Y
32.9 ft2: 1 ft 0 in 1 ft5 in Drapesiblinds
6.9 ft2., 1 ft0 in . 1 ft5 in .; None
24.0 ft2 6 ft 0 in 1 ft$ in None.
37.5.ft2 1 ft0 in 1 ft5 in: None
40.0 ft2, _ 8 ft 0 in 1 ft 5 in Drapes/blinds
Exteriors
None;- .
None
None
Exteriors .
GARAGE
# FloorArea
CeilingArea Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 315 ft2
315 ft2 24 ft
8 ft 11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 " Wholehouse ProposedACH(50)
.000356 1349.6 74.09 139.34. .1233 7
HEATING SYSTEM
# System Type
Subtype .Speed Efficiency
Capacity.: Block.
Ducts
1 - ElectricHeatPump/
Split. Single HSPF:8.5
34.8kBtu/hr 1•.
sys#1
COOLING SYSTEM . .
# System Type
Subtype Subtype Efficiency
Capacity Air Flow. SHR Block
Ducts
1 CentralUnit/
Split Single SEER:1.5
34.8 kBtu/hr cfm _ 6.8 1
sys#1
-HOT WATER SYSTEM
# System Type
SubType
Location EF Cap
Use SetPnt : Conservation:
1 Electric
None
Garage 0.97 40 gal 60.9 gal 120 deg None
1/8/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - Fl6Res2017 FBC 6th Edition;(2017) Compliant Software Page 4: of 5:
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector. Storage.
Cert # . CompanyName
System Model# CollectorModel#
Area. "." "Volume..
;'
"FEF.
None None
ft2 .
DUCTS.
• .. .
Supply—
— Return —
Air
CFM 25 CFM25: s
HVAC
# Location R-Value
Area
Location
Area
LeakageType
Handler
TOT OUT QN . " RLF
Heat Cool
1. Attic. 6
175 W
'Attic
65 ft2
DefaultLeakage
Attic..
(Default) c(Default) c-
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
"
Cooling an Feb
Heating Jan" Feb'
Mar
Mar
Apr
f Apr
f
May
May
Jun Jul
Jul
Junri
P
X Aug
Au
I
Sep Oct - Nov
SeP Oct HNov
Dec
Dec _
Ventin Jan Feb
X Mar
[X] A r
[
Ma
Jun Jul
Au
Se [X] Oct
Nova
Dec "
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
Q
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78 " ""
78
.78
78
78 "" 78
78
78
80 .80..
80
.80
PM
80
80
78
- 78"
78 78
78 -
78
78 '78 .
78 "
.78 .
Cooling (WEH)" AM"
78
78
78
78
78 78
78"
78-
" 78 78
78-
78
PM
78
78
78
78
78 - 78
78
78
.
78: 78 -
.78
78
Heating (WD)" AM _
66
66
66
66
66 68 .
68 :.68
: .-" 68 68
68.
:68
PM
68
68
68
68
68 68
68
68
68- 68 -
.66
.. 66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68.
68 .68
66 -
66
MASS'
Mass Type
Area
Thickness Furniture Fraction
Space.
Default.(8lbs/sq.ft..
0 ft2
0 ft
0.3
-
BEDROOM
Default(8lbs/sq.ft."
ft2
ft
0.3
WIC
Default(81bs/sq.ft...
ft2
ft
0.3
M: BATH_.
Def6ult(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8lbs/sq.ft. "
ft2
ft
0.3
BATH"
Default(8lbs/sq.ft.: -
ft2_
ft
0.3
BEDROOM-2
Default(81bs%sq.ft.
ft2
ft
0.3:
ENTRY'
Default(8lbs/sq.ft.
ft2.
ft
0.3
LAUNDRY
Default 8lbs/s .ft."
ft2
ft
0.3
GREAT/DINING
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts,, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated. .
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
AXtAnd behind pupong and Wring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall .
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover Mates and walls or ceelinas-
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1/8/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: r�►���
Address of New Home:\"-k&;i6'A a->q \�) 5 City/FL Zip: FT. PIERCE, FL -'S ` ti 'VI
• 1/8/2020 4:19:34 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1