HomeMy WebLinkAboutEnergy Codeos�S
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUFLDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE ROYALE IMPACT
Builder Name: WYNNE
Street: WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Owner: (_Olo q'-3
Permit Number:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types.(1688.7 ,sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1448.70 ft2
3: Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 240.00 ft2.
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1750.0 sgft.)
Insulation Area.
6. Conditioned floor area above grade (ft2) 1720
a, Under. Attic (Vented)
b. Wall (Vented)
R=30.0 1720.00 ft2
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(155.4 sgft.) Description Area
11. Ducts
Sup: Attic, Ret Attic, AH: Attic
R . ft2a.
6 175
a. U-Factor: Sgl, U=1.04 115.42 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2'
12. Cooling systems
kBtu/hr Efficiency
SHGC:. SHGC=0.27
a. Central Unit
34.8' SEER:15.00
c. U-Factor: N/A ft2
SHGC:
d. U-Factor: N/A ft2
13. Heating systems
kBtu/hr Efficiency
SHGC:
a. Electric Heat Pump
34.8 HSPF:8.50
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1720.0 sqft.) Insulation Area
a. Electric
Cap: 40.gallons
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
C. N/A R= ft2
45_ Credits .
Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 56.36
1� A SS
PASS
Total Baseline
Loads: 56.25
hereby certify that the plans and specifications covered by
this
Review of the plans and
calculation are in compliance with the Florida Energy
specifications covered by this
�, -: 0
Code.
.calculation indicates compliance,
with the Florida Energy Code.*
PREPARED BY:�%'
�--� - -
Before construction is completed
DATE: I-9-20
this building will be inspected for
- •~'
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance,
the Florida
Florida Statutes.
with Energy Code.''
OWNER/AGENT:
BUILDING OFFICIAL:
1r
DATE: ��
DATE:
Compliance requires certification by the air handler unit manufacturer that the air -handler enclosure qualifies as .
certified factory -sealed in accordance with 11403:3:2:1.
- Compliance requires an Air*Barrierand Insulation Inspection Checklist.in accordance with R402A.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R4ft EW E D FOR
CODE COMPLIANCE
ST. LU.CIE COUNTY
1/8/2020 4:66 PM EnergyGauge® USA 6.0:02 (Rev. 1) - FlaRes2017 FBC 6th Edition. (2017) CompPangoyVA4 Page 1. of 5
FORMR405-2017 INPUT SUMMARY:"CHECKLIST REPORT
PROJECT
Title: WYNNE THE ROYALE IMPA Bedrooms:. 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1720
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE
Rotate Angle:. 90
Street:'
WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
Cross Ventilation:. No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH MUNI 39 90
70
75 "
299
62
Low.
,BLOCKS
'Number Name'
Area. Volume
1 Entire.House
1720 13760
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 BEDROOM
343 2744 No 0
1
1
Yes,
Yes
Yes
2 WIC
63 504 No 0
1
No.
Yes'
'Yes
3 M.BATH
56 448. No 0
1
Yes
Yes
Yes
4 KITCHEN
172 1376 Yes 0
1
No
Yes
Yes
5. BATH
45 360 No 0
1.
Yes
Yes
Yes
6 BEDROOM 2
204 1632 No 0
1
1
Yes
Yes
Yes
7 ENTRY
98 784 No 0
1
Yes
Yes
Yes
8 LAUNDRY
42 336 No 0
1
Yes
Yes
Yes
9 GREAT/DINING
528 4224 No 0
1
Yes
Yes
Yes
10 BEDROOM 3
169 1352 No 1
1
1
Yes
Yes,
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
- Area
Joist R-Value
. Tile . Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52.ft 0
343 ft2
____
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ftZ
____
0 1
0
3 Slab -On -Grade Edge. Insulatio
M: BATH 8 ft 01
' 56 ft2
0 1.
0
4Slab-On-Grade Edge Insulatio
KITCHEN 1 ft 0
172 ft2
____
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45'ft2
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM-2 42.6 ft 0
204 ft2
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 6.3 ft 0
98 ft2
_
0 1
0
1/8/2020 4:5 6PM EnergyGauge® USA 6.0.02,(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 2 of.5
FORM R405-2017 INPUT -SUMMARY -CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge: Insulatio . LAUNDRY 6 ft 0
42 ft2
0
1
0
9 SIab-On-Grade Edge Insulatio GREAT/DINING 48 ft 0
52812
_
0
1
0
10SIab-On-Grade Edge Insulatio BEDROOM.3 13 ft 0
169 ft2
____
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type. Materials Area
Area
Color
Barr
•Absor...Tested
Tested. Insul..
(deg).
1
Gable or Shed Metal 1813 ft2
286 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1720 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic. (Vented) BEDROOM
30.
Blown
343ft2.
0.1
Wood '
2
Under-Attic(Vented) WIC
30
Blown.
6312
0.1
Wood
3
Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown'
.
172 ft2
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0..1
Wood
7
Under Attic (Vented) -ENTRY
30
Blown
98 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528 ft?
0.1
Wood
10
Under Attic (Vented) BEDROOM 3
30'
Blown
169 ft2
0.1
Wood
11
Knee Wall (Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Cavity Width
SpaceArea
Height
Sheathing . Framing Solar Below
lle
o
1
N=>E
Exterior Concrete Block -Int InsuBEDR00M
4.1 9 •
0 .. 8
, 0
72.0•ft2
0
0.
0.4
0
2
S=>W
Exterior Concrete Block - Int InsuBEDROOM
4.1 .29
0 8
0
232.0 ft2
0
0
0.4
0
_ 3
W=>N
Exterior Concrete Block - Int InsuBEDR00M
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4
S=>W
Exterior Concrete Block = Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5
N=>E
Exterior Concrete Block- Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
6
0.4
0
6
N=>E
Exterior Concrete Block - Int InsHIEDROOM 2
4.1 1.4
0 8
0
112.0 ft2
0
0
0.4
0
7
NE=>SE
Exterior Concrete Block = Int InsREDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.4
0
8
E=>S
Exterior. Concrete Block -.Int InskDROOM 2
4.1 9
0 8
0
72.0 ft2
0
0.
0.4
0
_ 9
SE=>SW Exterior Concrete Block. = Int InsBIEDROOM 2
4.1 .2-
10 8
0
22.7 ft2
0
0
0.4
0
10
S=>W
Exterior Concrete Block - Int InsE EDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0.
0.4
0
_ 11
NE=>SE
Exterior Concrete Block- Int Insul ENTRY
4.1 '.1
5 8
'0
11:3 ft2
0
0
0.4
0
1/8/2020 4:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY C'HFCKI 1ST RFPnRT
WALLS
Adjacent Cavity Width
Space
Height
Sheathing Framing . Solar Below
o
12
E=>S Exterior Concrete Block - Int Insul ENTRY 4.1 5 0 8
0 40.0 ft2
_
0
0 0.4
0
13
S=>W Exterior Concrete Block - Int InsuLAUNDRY 4.1 6 0 8
0 48.0 ft2
0
0 0.4
0
_ 14
N=>E Exterior Concrete Block - Int Insu6REAT/DINI 4.1 28 0 8
0 224.0 ft2
0
0 0.4
0
15
W=>N Exterior Concrete Block - Int InstOREAT/DINI 4.1 20 0 8
0 160.0 ft2
0
0 0.4
0
16
N=>E Exterior Concrete Block - Int InsiNEDROOM 3 4.1 13 0 8
0 104.0 ft2
0
0 0.4
0
_ 17
N=>E Garage Frame - Wood BEDROOM 3 11 30 8
.240.0 ft2
0.23 0.4
0
DOORS
# Ornt Door Type Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 E=>S Insulated ENTRY None
.32 3
6 8
20 ft2
WINDOWS
Orientation shown. is the entered orientation => changed to Worst Case.
/
Wall
Overhang
V
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp
Area Depth
Separation Int Shade
Screening
1 W=>N 3 _Metal Low-E Single Yes 1.04 0.29 N
32.4 ft2 1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior 5
2 S=>W 4 Metal 'Low-E Single Yes 1.04 0.29 N
6.9 ft2 1 ft 0 in
1 ft 5 in
None
None
3 E=>S 8 Metal Low E Single Yes 1.04 0.29 N
23.2 ft2 1 ft 0 in
1 ft 5 in
None
None
4 N=>E 14 Metal Low-E Single Yes 1.04 0.29 N
36.8 ft2 1 ft 0 in
1 ft 5 in
None
None
5 W=>N 15 Metal Low-E Single Yes 1.11 0.27 N
40.0 ft2 10 ft 0 in
1 ft 5 in
None
None
. 6 N=>E 16 Metal, Low E Single Yes 1.04 0.29 N
16.2 ft2 1 ft 0 in
1 ft 5 in
None
None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 ft2 300 ft2 30 ft
8 It
11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .1233
7
HEATING SYSTEM
# System Type Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split Singl HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLINGSYSTEM
# System Type Subtype Subtype Efficiency
•Capacity Air Flow
SHR Block
Ducts
1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
1/8/2020 4:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM Pdnl;i_7f147 IAIDI IT.Ci iRfiRAADV-f%UCt%V1 ICT CCM^07 "
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97
40 gal'
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector . Storage
Cert # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ — Supply --
--=
Retum —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN" RLF
Heat Cool
1 Attic
6 176 ft2.
Attic "
65 ft2
- Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin [[ ]] Jan [[ �Feb
Heating [X] Jan [X] Feb
[j Mar
Mar
r
[
A r
.� Apr
[
[
] Ma
• ] May
[X Jun �X] Jul
['� Jun [ ] Jul
(X Au
[ `� Aug
Sep
ri Se
[ Oct [r j,Nov
[ Oct
Nov
[ �Dec
lX] Dec
Veni [ ]] Jan [[ jj Feb
[Xj Mar
lxl
[X
A r
[
] Ma
[ Jun [ ] Jul
[ Au
Se
[X Oct [X]
lxJ
Nov
[[ ]] Dec
Thermostat Schedule: HERS2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
7t
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (VVD) AM
66
66
66
66
66 68
68
68
68 68'
68
68
PM
68
68
68
68
68 68
68
68
68 .68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
.68,
68 68
68
68
PM
68
68
68
68
68. .68
68
68
6&' 68 -
.66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(81bs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq:ft:
ft2
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN .
Default(8 Ibs/sq.ft,
ft2
ft
0.3
BATH
Default(8 Ibs/sq:ft.
ft2
ft ".
0.3
BEDROOM 2
Default(8 Ibs/sq:ft.
ft2
ft
0.3
ENTRY
Default(81bs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/s .ft:.
ft2
fb
0.3
GREAT/DINING
1/8/2020 4:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FI6Res2017 FBC 6th Edition (2017) 'Compliant Software . Page 5, of 5.
• 2017 -AIR BARRIER AND, INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATIOWNSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
w
.Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION -INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a. continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any. dropped ceiling/soffit shall.be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to.
unconditioned attic spaces shall be sealed.
Walls
The junction of -the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top: plate and the top of exterior walls shall be -
shall be insulated by completely filling. the cavity
sealed.
with a material having a thermal resistance of 9-3
Knee walls shall be. sealed.
per inch minimum. ,
-Exterior thermal envelopelilisulatiori for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier:
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.'
Rim joists
Rim joists shall include the air barrier:
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing. cavity insulation shall be installed.to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the'
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned s ace shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the. drywall.
thermal envelope shall be air tight and IC rated._
Plumbing; and wiring
Batt insulation shall be cut neatly to, fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Showerltub
The air barrier installed at exterior walls adjacent to. showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air.barrier shaif be installed behind electrical or communication
exterior wails
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate- building thermal envelope shall
be sealed to,the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers: shall only be
sprinklers
sealed. in a manner that is recommended, by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire speinkler cover plates and =Ila or ceilings,
a. in aaamon, inspection oT rog,.waus snau oe in accoraance wim me provisions-oT IL..u-4uu.
1/8/2020 4:57 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant. Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY -CARD -
ESTIMATED ENERGY PERFORMANCE INDEX* =.100
The lower the Energy Performance Index,.the more :efficient the home.
1. New home or, addition
1. -New (From Plans)
12. Ducts; location & insulation level
a) Supply, ducts R
6.0
2. Single-family or multiple -family
2. Single.family
b). Return ducts R
6.0.
c) AHU location
Attic
3. No. of. units (if multiple -family)
3.
1
4. Number of bedrooms
4.
-3
13. Cooling system: Capacity' '
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER .
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1720
d) Room unit(PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average.)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
155.4
a), Split system heat pump HSPF .
•8.5
b) Single package heat pump: HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)'
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace,. LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R=value)
9c.'
a) Electric resistance EF
0.97
b} Gas fired, natural gas. EF
10. Wall type and insulation:
" c).Gas fired, LPG EF
A: Exterior:
d) Solar system with tank EF
1. Wood frame. (Insulation R-Value)
10A1.
e) Dedicated heat pump with tank EF
2..Masonry'(Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%o
B. Adjacent:
g)-Other
1. Wood frame (insulation R-value)
1061.
11.0
2. Masony (Insulation R-value)
1062.
16'. HVAC,credits claimed (Performance Method)
11. Ceiling type' and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c..
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
.
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation; if not DEFAULT
I certify that this home has complied with the Florida Building. Code, Energy Conservation, through the above energy
saving features which :will be installed (or exceeded): in. this home before final inspection. Otherwise, a new EPL .
display card will be completed based. on' installed code compliant -features.
`Builder Signature:_ _ Date:
Address of.New Home:., WYNNE DEV. tpy''' � \ C� City/FL'Zip: FT. PIERCE: FL
1/8/2020 4:56:58 PM EnergyGaugeO USA 6.6.04 (Rev. 1) - HaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1