Project Summary oa - wrightsoft Entire House By: QUICK CALCS, INC. 317 ST.-LUCIE IN., FT. Pl For: THE ROYALE WYNNE DEV., FT PIERCE, FL Notes: C\ Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range' L Relative humidity 50 %. Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19898 Btuh Structure 18607 Btuh Ducts 6092 Btuh Ducts 9204 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25990 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 26420 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2182 Btuh Ducts 2516 Btuh Central vent (0 cfm) 0 Btuh ' Heatingg Coolingg. (none)... Area (ft2) 1720 1720 Equipment, latent load 4697 Btuh Volume (ft3) 14231 14231 Air changes/hour 0.38 0.20 Equipment total load 31117 Btuh Equiv. AVF (cfm) 90 47 Req. total capacity at 0.70 SHR 3.1 ton Heating. Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR-CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating.input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800'. Btuh Actual air flow 1160 cfm Actual. air flow 1160. cfm Airflow factor 0.045 cfm/Btuh :Air flow factor 0.042 cfm1Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point = 35 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �- wrightsoft` . 2017-Apr-10 17:29:34 Right -Suite® Universal 201717.0.14 RSU08101 Page 1 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MA Front Door faces: N FF wrightsoft9 RighW@ Worksheet Job: Entire House Date: bay: • QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@.AOL.COM 1 Room name Entire House BEDROOM 2 Exposed wall 180.9 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heat1cool 4 Room dimensions 1.0 x 343.0 ft 5 Room area 1719.5 ft2 343.0 ft2 Ty Construction LI-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 VJJ�C:AA-c1om 13A-0oos 0.143 n -4.00 2.55 577 ' 524 2096 1333 72 72 288 183 1 270 • n' 35 56 34.77 16 .0 565 553 0 '0. .0 0 �G 4AS2om .0.77.0 . n 21.56 19.31 38 0 815 730 0 0 0 w 0 W 13A4ocs . 0143 ne 4.00 2.65 34 34 136 86 0 0. 0 0 11 13A-0ocs 0143 e . 4.00 2.55 112 67 269 171 '0_ .0._- 0 0 1Ac1om ,:: 1.270 e : 35:56 87,29 24 3 848 2082 0 0 ; 0 0; 11D0 .: - 0 390 , e:` 1092 1131 21 21 229 ... 238 _ 0 W 13AAocs 0.143 se 4.00 2.55 23 23 91 58 0 0 0 0 13Aftocs ` 0 143 s: 4 00 2 55 456 449 `-1798 ' ' 1143 -` 232 - 232: 929 591 1Ac.1om;. 1270, s 35:56 347Z .7 14 247 2 1 0 -; Ai... 0 0 Val 13AAocs 0.143 w 4.00 2.55 290 217 867 651 112 79 318 202 �--G IA-clom 1.270 .w 35.56 55.25 33 4 1162 1806 33 2 1162 1806 L 4A5.2om 0.770 w 21.56 45.63 41 4 880 1862 0 0 0 0 P ;12C-0sw .; . ; .... 0 091' = `: 2,55.: " ,1i28 , ; 224 :.. _- .. ,. •224 .. .571 ; . 287 .0 _ 0 "0 0 C 16A-30md 0.032 - 0.90 , 2.32 1720 1720 1541 3989 343 343 307 796 F 22A fpl - . 0 989 ' - .- 27.69 .. .::0.06 . 7*20 ' .' 181.... 5010 0 ;' 343 ; :.: 52 - . . ;1� ; . ', A. i 6 c)AED excursion 4651 W8 Envelope loss/gain 17124 15595 4444 4245 12 a) infiltration 2774 782 773 218 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 2000 0 Subtotal pines 6 to 13) 1989B 18607 5218 4463 Less external load - 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19898 18607 5218 4463 15 Duct loads 31% 49% 6092 9204 31% 49%1 1598 2208 Total room load 25990 27810 6815 6671 Air required (cfm) 1160 1160 304 278 Calculations approved byACCA'tti meet all requirements of Manual J 8th Ed. wright5oft- M17-Apr-10 17:29:34 AM Right -Suite® Universal 2017 17.0.14 RSU08101- Page 1 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N ' - wrightsoft' ' Right-M Worksheet Job: Entire House Date: By: QUICK CALLS, INC. 317 SM LUCIELN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM 1 Room name WIC M. BATH 2 . Exposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 7.0 x 8.0 ft 56.0 ft2 Ty Construction number U-value (Btuhfft?'F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A41ocs . 0143 n 4.00 2.55 0 0 0 0 0 0 0' 0 1Aclom " .1. 270 " n 35.56 34..N 0 .0 .0 0: 0 ' 0. 0 0 4A5.2om 0.770 ' n 21.56. 19.31 0 0 0 0 0 .0 0 -: 0 W 13A4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0. 0 0 11 93 466; 0143 e 4 00 2 55 % 0 0 0 0.. 0 0 =0 1Ag1om, 1 270 e. 35 56 8T2Q 0 0 0 s. 0 0 0 '_ :0 Q 11D0 0390 e;` 10.92 1131; 0.; 0 ... 0 •, . - 0 ;T 0:. 0 W 13AAocs 0.143 se 4.00 2.55 0 0 0 0- 0 0 0 0 -0143 s i 4 00; 255 0 c 0 . 0 0 64 57 . ?28 145; 1'270 , s. ? • 35 56, .. 3477 :0 0 : 0 >. ". 0 7 . ; Z ; 247 :. 241; 13A•4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 IA-clom 1.270 w 35.56 55:25 0 0 0 0 0 0 0 0 u--G .4A5.2om 0.770 w 21.56, 45.63 0 0 0 0 0 0 0 0 12C-0sw;.. t 0 091 ' _ . "255' 128 ,.... 0 0 0 .. ; .,0 ':: :. p 0 C 16Ar30md 0.032 - , 0.90 2.32 63 63 56 146. 56 56 50 130 "F., ° 229fpl = . IJA89 ; . ; ._0:00 ... ::. . • ' 63 ' ` : 0 . . • . 0 - . 0 "- 56 ''": , 8 :' ..: ` ~. 0. 6 c)AED excursion -10 -39 Envelope loss/gain 56 1361 747 477 12 a) Infiltration 0 0 119 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 56 136 866 511 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 866 511 15 Duct loads 31% 49% 17 67 31% 49% 265 253 Total room load 74 203 1131 764 Air required (cfm) 31 8 50 32 Calculations approved byACCA'to meet all requirements of Manual J 8th Ed. 145eA41- wrightsoft' Right-S2017-Apr-10 17:29:34 uite® Universal 2017 17.0.14 RSU08101 Page 2 ...14ulck CalcslDocuments\WYNNE-ROYALE-REVISED:rup Cale = MJ8 Front Door faces: N Job: eet Date: Entire House Date: QUICK CALCS,INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name KITCHEN BATH 2 =ed wall 0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 172.0 ft 172.0 ftz 9.0 x 5.0 ft 45.0 ftz T Y Construction U-value Or HTM Area number (Btuh/ftMF) (Btuh/ft2) 1 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T� 13AAocs 0143 " n 4 00 2.55 " 0 0 0, 0 40 40 160 102 1Ac1om 1270 n 35:56 34.77 0 0 0 0 0 0. 0 0 4A5-2om. 0.770 ; n. 21.56 . 19.31 : 0 .. 0 0 0 0 a 0 0: 0 W 13AAocs . 0.143 ne 4,00 2.55 0 0 0 0 0 0 0 0 11 13A-40cs .. 0143 e 4 00 2 55 0 0 0 0 0 0 0 0. 1Ac1cm =1;270 e.-; 35:56 8T29 .0 0 0 _ 0 .. 0 ",. 0 -0 '.0 11D0 10 92:. 11.31 0 0. 0„ 0 .: 0 -; 0 Q 0 W 13AAocs 0.143 -se 4.00 . 2.55 0 0 0 0 0- .0 0 0 V�1 L'=rs.lAc1om 73Altocs ` O.143 s ;; 4 00 2'S5 0 0 , 0 0 0 :`:' 0; 0 "0 ,, 1:270.s' 35.56I .. 3477 .. 0 p :•. 0'. 0'-. 0 0` 0 -0 yJ 13AAocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Ao1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4A5-20m 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 12C-0sw , <64 163 ". 82 0.:. 0 .. p P. C 16A-30md 0.032 - 0.90. 2.32 172 172 154 399 45 45 40 104 0:989 ; . -• : 27:69 "''600 ` `1:72 : 0 - 01 .;0 . > 45 -: 5 138 6 c)AED excursion -176 -16 Envelope loss/gain 317 305 339, 190 12 a) Infiltration 0 0 74 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 317 2305 413 211 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 317 2305 413 211 15 Duct loads 31% 49% 97 1140 31% 49%1 127 104 Total room load 414. 3446 1 1 546 315 "Air required (cfm) 1 118 144 241 13 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C -� wrightsoft~ 2017-Apr-10 W:29:34 .eft Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Cale = MJ8 Front Door, fa"ces: N Job: +P- wright,Oft RigbW@ Worksheet Date: Entire House' By: • QUICK CALCS, INC.- 317 ST LUCIE LN., FT PIERCE, FL 34946 Phone: 772466,6799 Fax 772-466-679 6 Email: QUICKCALCS@AOL.QOM 1 Room name BEDROOM 2 'ENTRY 2 E)q)dsed*wWl 42.6 ft 6.3 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 204.0 ft 1.0 x 97.5 ft 5 Room area 204.0 ft2 97.5 ft2 Ty Construction U-value. Or HTIVI Wa. (ft2) Load Area . (ft2) Load number (Btuh/ft2L*F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat cool Gross N/P/S Heat cool 6 -W 13A4ocs 0.143 n .4.00 2;55 112 112 448 285 0 0 0 AA-c.1bm 11,270 n .:35.56, 34.7,7 , 0 o 0 '0' 0 . '0 :0 .0 4A5-2oM 0.770 n 21.56 19.31 0 0 0, 0 0 .0 0 0 w 13A.4- .0.143 ne 4,00 2.55 23 23 58 11 11 45 29 11 11 3A-,4ocs 0-'143', e, A400 Z55 72 48 .91 193 123.", 40 - 76:' 48 'V:29 "24 .. .. 0 ... ... 0390 X, 10.92 "o - 01 �2: 21 229.1238 W 13A4ocs 0.143 se 4.00 2.55 23 23 91 58 0 0 0 0 0 0,14 4 -2.,5%, 121" 0: 35% 34.771: ILI13A4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 .0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 :0.091 < , 255 A .26,-,. 0 P., 104,,- 133 C 16A-30md 0.032 0.90 2.32 204 204 183 473 98 98 ,205 87 226 �122A- '1 "Itp 4,089 27A91 -:2'04 -.43 -1119: 9'8 '6 '175 0 61 c)AED excursion -90 --50 Envelope loss/gain 3481 3273 878 625 12 a): Infiltration 634 179 95 27 - b) Room ventilation 0 0 0 0 13 Internal gains: Occupants. @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pins 6 to 13) 4115 3452 974 651 Less wdemal load 0 0 .0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 .0 14 Subtotal 4115 3452 974 651 15 Duct loads 31% 490/. 1266 1708 31%1 49%1 2981 322 Total room load 5376 5159 1? 974 Air required (cfm) 240, 215, 572 7 41 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ad- Right -Suite® Universal 20 2017-Apr-10 17:29:34 AM 17 17.0.14 RSUD8101 Page 4 ... \Quidk CalcsXDocuments\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N - - wrigntsoft- Righ"o Worksheet Job: Entire House Date: By: . QUICK CALCS, INC. 317 ST, LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 ft 48.0 ft 3 Room height 8.0 ft heat/cool 8.9 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft' 1.0 x 528.0 ft 528.0 ft' Ty Construction U-value Or HTM Area (ft-) Load Area (ft') Load number (Btuhlftl�-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S. Heat Cool 6 13AAocs 1A clom 0143 1270 n n 4.00 35i66 Z55 ' . 34.77 " 0 0 0 0. 0 0 0 .0 249 0 211 : 0 846 "0 538 0 4A52om 0.770 n- 2156 19.31 0 0 0 .0 38 : 0 815 ' 730 W 13A4ors 0.143 ne 4.00 2 55 0 0 0 6 0 0 0 0 11 13A-4c 0143 e 4.00 2 55 0 0 0 0 0, 0 0 0 1Ac1om , '1 270 a `, 3&56 87 29 0 0 0 ,.. or.: 0 0 ..0 :.0: 11D0 0390..e' 1092 1131 0. .,.:. 0,.. 0; 0..' 0: W 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 14"13A-0oCs . 0143 s'` 4 00 2 55 48 48 A 62 122 - . 0 .0 1Ac1om: . 1.270 , s' 35356 3477 0 0 0 0 , :' 0'; 0 yJ 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 178 137. 549 349 1Aclom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 IF---CG 4A5-20m 0.770 w 21.56 45.63 0 0 0 0 41 2 880 1862 412C-0sw < , 0.69 - : -2.55 V; b 56 : : _ ""56 , . : 143 72 : ; ;0 C 16A30md 0.032 - 0.90 2.32 42 42 38 97 528 528 473 1225 F 22lkfpl " . . 0 989 ; ` .-27 69 ..-0;00 :' 42 1, . • ".6.' : 166 :' S 0 48 1329' : -' %0 6 c)AED excursion -22 305 Envelope loss/gain 539 269 4893 5008 12 a) Infiltration 69 25 794 224 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) . 628 294 5687 5232 Less extemal load 0 0 '0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 628 294 5687 5232 15 Duct loads 31% 49%1 192 146 31% 49% 1741 2588 Total room load 820 440 7428 7821 Air required (cfm) 37 18 332 326 Calculations approved bvACCA to meet all requirements of.Manual J 8th Ed. .,. -F- wrighisoft' 2017-Apr 1017:29:34 A Right -Suite® Universal 2017 17.0.14 RSU08101' Page 5 ...\Quick CalcslDocumentslWYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N + wrightsoft° Right.40 Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOLCOM 1 Room name BEDROOM 3 2 =ed well 13.0 ft 3 Room height 8.0 ft heaticool 4 5 Room dimensions Room area 13.0 x 13.0 ft 169.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btu1Vft2--"F) (Btuh/ft2) 1 or perimeter (ft) (Btuh) or perimeter Heat Cool I Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0om 0.143 :. n, 4.00 2;65 104 88 353. 224 l clom 1270 - n 35.56 13477 16 0 - 565 553 '4A"rn 0.770 . n 21:56 19.31 .0* 0 0. 0 W. 13AAws 0.143 ne 4.00 2.55 0 0 0 0 11 13A-4ocs 0.143 e 4 00 .255 0 0 0 0 1Ac1om 1:270 e ; 35 56 87 2Q 0 0 0 0 0:390 ..e. 10:92' 11:31 0 , _, p 0 0 W. 13A40cs 0.143 se 4.00 2.55 0 0 0 0 J 13A46cs ,: 0143 s . 4 00 2 55 0 0 0 " : . 0 t —(' 1Ac1om :- 1270 . s.. 35.,5.6y 3417.7. 0 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 1A-c1om 1.270 w 35.56 55:25 0 0 0 0 G 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 P 12C-0sw+-_ ;;0091 =':: 2:55'. 126 0 0 : : 0:. ;' 0 :. C 16A-30md 0.032 ' - 0.90 2.32 169 169 151 392 :. ,F ; e22A tpl :, .. ' .60 89. , 27 69 0:00 :: 169 ... 13 6 c)AED excursion -103 Envelope loss/gain 1430 1066 12 a). Infiltration 193 55 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 0 Subtotal Qines 6 to 13) .. 1623 1351 Less eAemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 . Subtotal 1623 1351 15 Duct loads 31% 49% 497 668 Total room load 2120 2019 Air required (cfm) 95 84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. L +k wrightsoft- 2017-Apr-10 17:29:34 �P. Right -Suite® Universal 201717.0.14 RSU08101 Page 6 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N - - wrightsof ." Duct System Sullnmary pat Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799: Fax 772-466-6796 Email: QUICKCALCS AOL.COM eLroject intormation For: THE ROYALE WYNNE DEV., FT. PIERCE, FL Extemalstatic pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating. 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.286 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.286 in/100ft 1160 cfm 175 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Cig (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 540 24 13 0.351 4.0 Ox 0 VIFx 27.3 115.0 st1 BEDROOM h 3408 152 139 0.286 7.0 OxO VIFx 40.1 135.0 st2 BEDROOM 2 h 5376 240 215 0.343 7.0 OxO VIFx 30.8 115.0 st1 BEDROOM 3 h 2120 95 84 0.371 6.6 Ox0 VIFx 19.9 115.0 st1 BEDROOM -A h 3408 152 139 0.297 7.0, Ox 0 VIFx 33.1 1.35.0 st2 ENTRY h 1272 57 41 0.485. 4.0 ox0 VIFx 8.1 05.0 GREAT/DINING-A h 3714 166 163 0.300 7.0 Ox0 VIFx 31.7 135.0 st2 GREAT/DINING-B h 3714 166 163 0.309 7.0 Ox0 VIFx 27.1 135.0 st2 KITCHEN c 3446 18 144 0.376 7:0 Ox 0 VIFx 18.1 115.0 st1 LAUNDRY h 820 37. 18 0.369 4.0 Ox 0 VIFx 20.4 115.0 st1 M. BATH h 1131 50 32 0.366 4.0 Ox 0 VIFx 21.6 115.0 st1 WIC c 203 3 8 0.309 4:0 OxO VIFx 26.6 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 639 613 0:286 814 12.0 0 x 0 VinlFlx st1 SO Peak AVF 1103 . 1119. 0.286 802 16.0 0 x 0 VinlFlx .` 9 wri htsofte �� � Right -Suite® 2017-Apr-1017:29:35 Universal 2017 17.0:14 RSU08101 Page 1 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJB Front Door faces: N 0 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/joist Opening (in) Duct Mati Trunk rb1 OxO 11160 1160. 0 0 0 0 Ox 0 VIFx wri htsoft° 2017-Apr-1017:29:35 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 �'� ...1Quick Calcs\DocumentslWYNNE-ROYALE-REVISED.rup Cale = MJ8 Front Door faces: N