HomeMy WebLinkAboutCompaction Test 2020 12 17 - Klein 2104UES Project No:
Workorder No:
Report Date:
3360.1900024.0000
220766-1
12/22/2020
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:MASTERPIECE BUILDERS UES Technician:Mark Rogers
410 Colorado Avenue
Stuart, FL 34994
Date Tested:12/17/2020
Project:19-2061 MASTERPIECE BUILDERS 2019 MASTER
12772 NW Mariner Court, Palm City
Type of Test:
Area Tested:Elevator Wall and pit footings Field:ASTM D-6938 Nuclear Gauge Method
Material:Backfill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Bottom of Footing
The tests below meet the 98% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Elevator wall footings 0-1 ft 106.6 12.6 106.3 12.1 100 Pass
2 Elevator Pit footings 0-1 ft 106.6 12.6 105.7 12.0 99 Pass
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1