Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: n
DATE FILED: ,o� " ��� �v PERMIT#
REVISION FEE: �/ �s RECEIPT#
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE,FL 34982.56 t
(772)462.155 "` ► _:
APPLICATION FOR BUILDING P R c '
PROJECT INFORMATIO
LOCATION/SITE
ADDRESS:
DETAILED DESCRIPTION OF PROJECT
REVISIONS:CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: EL - S q - ST. LUCIE CO CERT. #:
BUSINESS NAME: S1, LilGi e
QUALIFIERS NAME:
ADDRESS:
CITY: 1'�, Q;�� STATE: T L ZIP: q qd
PHONE (DAYTIME): (%1 1) q 6 q-1 j i i FAX:
OWNER/BUILDER INFORMATION:
NAME: Sci in� (..c,t ci c
ADDRESS: 7 0 )- 5 C F>,
CITY: e,�,, $e z � r L, STATE: L— ZIP: tj q g
PHONE(DAYTIME: (-7-7,13 4 6-4-1 -G i G 7 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME: -6,6 PAnclsc% EoQ tn� ir-4
ADDRESS: c j y's�L e,�,,
CITY: r STATE: F-L ZIP:
. PHONE(DAYTIME): (7 72) FAX:
SLCCC: 9/23/09 RECEIVED
Revised 06130117 0EC yppp
File Co�
e i ing Department
St. Lucie count/
�. , .
`��� - ..
� -. �' -.
°�<
_�
j
_�
_�
_�
t
N Load Short Form Job: 5715 Palm Drive
- wrightsoft Date: January28,2020
Entire House By: Josh Putman
WebREPS, LLC Plan: Palm Drive Residence
1892 Commerce Aenue,Vero Beach,FL 32960 Phone:800-810-3280 Fax 888-971-2999 Email:sales@webrepshvaccom Vbb:vw,w.webrepswholesale.00m License:CAC054709
Project • •
For. Joseph Gianna,Habitat for Humanity
Ft.Pierce,FL
----Design • •
Htg Clg Infiltration
Outside db(OF) 42 90 Method Simplified
Inside db(OF) 70 75 Construction quality Semi-tight
Design TD(OF) 28 15 Fireplaces 0
Daily range - M
Inside humidity(%) 30 50
Moisture difference(grAb) 1 61
HEATING EQUIPMENT COOLING EQUIPMENT
Make Goodman Make Goodman Mfg.
Trade Heat Strip Trade GOODMAN
Model Cond GSX160301 F
AHRI ref Coil ASPT30C14A
AHRI ref 200825240
Efficiency 100 EFF Efficiency 13.0 EER,16 SEER
Heating input 8.0 kW Sensible cooling 20424 Btuh
Heating output 27297 Btuh Latent"cooling 7176 Btuh
Temperature rise 27 OF Total cooling 27600 Btuh
Actual airflow 920 cfrn Actual airflow 920 cfrn
Airflowfactor 0.051 cfmBtuh Airflowfactor 0.049 cfmBtuh
Static pressure 0.60 in H2O Static pressure 0.60 in H2O
Space thermostat Load sensible heat ratio 0.75
ROOM NAME Area Htg load Clg load HtgAVF CIgAVF
(ft� (Btuh) (Btuh) (cfm) (cfm)
Bed 2 197 3627 2700 186 133
dst 2 21 0 0 0 0
Bath 2 117 1275 1399 66 69
Bed 3 191 2984 2643 153 130
clst 3 18 0 0 0 0
Kit Din LR 497 5274 8670 271 427
pnty 21 0 0 0 0
Bed 175 2743 2100 141 103
clst 1 18 0 0 0 0
Bath 1 82 2011 1157 103 57
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-�- wrightsoft" 2020-Dec-2109:41:114
M,..••,..,.,,.,,.,.,„„,�, Right-Suite®Universal 2019 19.0.21 RSU76998 Pagel
ACCR. ...Wabitatfor Humanity PSLtLot 30 Palm Drive.rup Calc=MJ8 Front Door faces:N le
COPY
Entire House 1335 17914 18670 920 920
Other equip loads 0 1707
Equip.@ 1.00 RSM 20377
Latent cooling 6921
TOTALS 1335 1 17914 27298 920 920
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrl„ghtsoft- 2020-Dec21 09:41:14
^+ „...,.,,,,,r.m PJght-Suite®Universal201919.0.21 RSU16998 Paget
ACCK...\Habitat for Humanity PSDLot30 Palm Drive rup Calc=MJ8 Front Door faces:N
Job: 5715 Palm Drive
+ wrightsoft" Proect Summa ry Date: January 28,2020
Entire House By: Josh Putman
WebREPS, LLC Plan: Palm Drive Residence
1892 Commerce Avenue,Vero Beach,FL 32960 Phone:800-810-3280 Fax 888-971-2999 Email:sales@webrepshvacmm Vkhb:www.webrepswholesale.com License:CAGO54709
Project • •
For. Joseph Gianna,Habitat for Humanity
Ft.Pierce,FL
Notes: 5715 Palm Drive Residence Florida
Design Information
Weather: Fort Pierce,FL,US
Winter Design Conditions Summer Design Conditions
Outside db 42 F Outside db
90 °F
Inside db 70 °F Inside db 75 °F
Design TD 28 °F Design TD 15 °F
Daily range M
Relative humidity 50 %
Moisture difference 61 gdlb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 14642 Btuh Structure 13274 Btuh
Ducts 3272 Btuh Ducts 5396 Btuh
Central vent(0 cf n) 0 Btuh Central vent(0 cfrn) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 1707 Btuh
Piping 0 Btuh
Equipment load 17914 Btuh Use manufacturer's data y
Rate/swin multiplier 1.00
Infiltration Equipment sensible load 20377 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 5389 Btuh
Ducts 1531 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Cooling (none)
Area(ft) 1335 1335 Equipment latent load 6921 Btuh
Volume(fF) 10678 10678
Air changeslhour 0.31 0.16 Equipment Total Load(Sen+Lat) 27298 Btuh
Equiv.AVF(cfm) 55 28 Req.total capacity at 0.74 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Goodman Make Goodman Mfg.
Trade Heat Strip Trade GOODMAN
Model Cond GSX160301 F
AHRI ref Coil ASPT30C14A
AHRI ref 200825240
Efficiency 100 EFF Efficiency 13.0 EER,16 SEER
Heating input 8.0 WV Sensible cooling 20424 Btuh
Heating output 27297 Btuh Latentcooling 7176 Btuh
Temperature rise 27 °F Total cooling 27600 Btuh
Actual airflow 920 cfm Actual airflow 920 cfm
Airflowfactor 0.051 cfm/Btuh Airflowfactor 0.049 cfm/Btuh
Static pressure 0.60 in H2O Static pressure 0.60 in H2O
Space thermostat Load sensible heat ratio 0.75
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft" 2020-Deo-21 09:41:14
.•� „•.....�._. RighFSuite®Universa1201919.021 RSU16998 Page 1
ACCI\ ...%Habitat for Humanity PSLM-ot30 Palm Drive.rup Calc=MJ8 FronlDoorfaces:N
N
Sheet 1
�r
12x8 r
186 cfm Bath 2
r dst 2 clst 3 1' Bed 3
611 = 10x6
153 cfm
Bed 2 RAW
01
811
t
511
12x12 8x4 12x12
69 cftn
10" 10"
8 x 8 18 x 18 Kit Din LR 8 x 8
107 cfm 8 x 8 1211 8 x 8 107 cfm
107 cfm 107 cfm
6"
6"
6 18" 20 x 20
6"
12 x 12
920 cfm
101.
1411 2 x 12 pnty
6"
10x6
18 x 18 103 cfrn
18x 12
Bed 1
"
t` Bath 1
8
Garage g 11
10x6
t dst 1
>: 141 cfrn
Job M 5715 Palm Drive WebREPS, LLC Scale:1 :69
rm Perfoed by Josh Putman for. Pagel
Joseph Gianna 1892 Commerce Avenue R4CS1iWUnvesal2D19
Vero Beach,FL32960 19.021 RSU169B
R.Pierce,FL Phone:800-81D-3280 Fax:888971-2999 ZMDeo-21094130
www.w+ebrepswholesale.com sales@webrepshvaacom
main PSLW3OPainDMenQ
Duct System Summary Job: 5715 Palm Drive
wrightsoftµ y ry Date: January 28,2020
Entire House By: Josh Putman
WebREPS, LLC Plan: Palm Drive Residence
1892 Commerce A-enue,Vero Beach,FL 32960 Phone:800-810-3280 Fax 888-971-2999 Email:sales@webrepshvac.com ftb:www.webrepswholesate.com License:CAC054709
Project • •
For. Joseph Gianna,Habitat fur Humanity
Ft.Pierce,FL
Heating Cooling
External static pressure 0.60 in H2O 0.60 in H2O
Pressure losses 0.24 in H2O 0.24 in H2O
Available static pressure 0.36 in H2O 0.36 in H2O
Supply/return available pressure 0.226/0.134 in H2O 0.226/0.134 in H2O
Lowestfiction rate 0.084 in/100ft 0.084 in/100ft
Actual airflow 920 cl n 920 cfm
Total effective length(TEL) 427 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FIR (in) (in) Mat Ln(ft) Ln(fl) Trunk
Bath 1 h 2011 103 57 0.093 6.0 Ox 0 VIFx 18.2 225.0 st2
Bath 2 c 1399 66 69 0.089 5.0 Ox 0 VIFx 24.6 230.0 st4
Bed 1 h 2743 141 103 0.093 6.0 Ox 0 VIFx 17.1 225.0 st2
Bed 2 h 3627 186 133 0.086 8.0 Ox 0 VIFx 32.7 230.0 st4
Bed 3 h 2984 153 130 0.084 6.0 Ox 0 VIFx 32.8 235.0 st4
Kit Din LR c 2168 68 107 0.100 6.0 Ox 0 VIFx 20.5 205.0 st3
Kit Din LR-A c 2168 68 107 0.099 6.0 Ox 0 VIFx 18.0 210.0 st3
Kit Din LR-B c 2168 68 107 0.096 6.0 Ox 0 VIFx 25.7 210.0 st3
Kit Din LR-C c 2168 68 107 0.101 6.0 Ox 0 VIFx 13.2 210.0 st3
supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (drn) FIR (fpm) (in) (in) Material Trunk
st1 PeakAVF 920 920 0.084 613 15.0 12 x 18 RectFbg
st2 PeakAVF 244 161 0.093 699 8.0 0 x 0 VinlFlx st1
st4 PeakAVF 405 332 0.084 516 12.0 0 x 0 VinlFlx st3
st3 PeakAVF 676 759 0.084 710 14.0 0 x 0 VinlFlx st1
L wrightsoTt- 2020-Deo-2109:41:14
Right-Suite(D Universal 2019 19.021 RSU16998 Page 1
)CCX ...Wabitatfor Humanity PSLTot 30 Palm Drive.rup Calc=MJB Front Door faces:N
i
4
Return Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size(in) (cfm) 0M) M FR (fpm) (in) (n) Opening(in) Mat! Trunk
rb4 Ox 0 920 920 159.2 0.084 521 18.0 Ox 0 VIFx rt1
TableReturn Trunk Detail
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
rt1 PeakAVF 920 920 0.084 409 15.0 18 x 18 RectFbg
F wrightsoft 2020-Deo-21 0941:14
RighFSuite®Universal 201919.0.21 RSU16998 Paget
Wabitatfor Humanity PSLNLot30 Palm Ddve.rup Calc=MJ8 FrontDoorfaoes:N