Loading...
HomeMy WebLinkAboutHODSON- ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 511/3/2020 10:22 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY MEL-RY CONSTRUCTION, INC.HODSON RESIDENCE Street: City, State, Zip: JENSEN BEACH , FL , 571 NETTLES BLVD Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 875 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.58 99.00 ft² SHGC=0.24 Sgl, U=0.52 20.00 ft² SHGC=0.29 N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 875.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1024.70 ft² b. N/A R=f t ² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 875.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.000 ft. Area Weighted Average SHGC:0.248 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 2 (119.0 sqft.) (1024.7 sqft.) (875.0 sqft.) (875.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 18.8 SEER:16.00 Efficiency k B t u / h r Efficiency 17.0 COP:1.00 f t ² R 6 125 EF: 0.980 Glass/Floor Area: 0.136 Total Proposed Modified Loads: Total Baseline Loads: 35.35 37.97 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 11-3-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY MEL-RY CONSTRUCTION, I 1 HODSON RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 875 2 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , JENSEN BEACH , St. Lucie 571 NETTLES BLVD Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 875 7000 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 M WIC 29 232 No 0 Yes Yes1 Yes 2 MASTER BEDROO 172 1376 No 0 1 Yes Yes1 Yes 3 STORAGE 33 264 No 0 Yes Yes1 Yes 4 WIC 2 18 144 No 0 Yes Yes1 Yes 5 BEDROOM 2 110 880 No 0 1 Yes Yes1 Yes 6 BATH 2 50 400 No 0 Yes Yes1 Yes 7 HALL 44 352 No 0 Yes Yes1 No 8 M BATH 65 520 No 0 Yes Yes1 Yes 9 W/D 24 192 No 0 Yes Yes1 No 10 KITCHEN 165 1320 Yes 0 Yes Yes1 Yes 11 LIVING RM 165 1320 No 0 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 29 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015.6 ft M WIC 2 172 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -019.8 ft MASTER BEDRO 3 33 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05.8 ft STORAGE 4 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07.8 ft WIC 2 5 110 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft BEDROOM 2 6 50 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2 11/3/2020 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 7 44 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 8 65 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft M BATH 9 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft W/D 10 165 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -026 ft KITCHEN 11 165 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -026 ft LIVING RM # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 948 ft² Light 0.3 20 22.6______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 875 ft² N N0 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 29 ft² 0.1 Wood______M WIC Blown 2 Under Attic (Unvented)0 172 ft² 0.1 Wood______MASTER BEDRO Blown 3 Under Attic (Unvented)0 33 ft² 0.1 Wood______STORAGE Blown 4 Under Attic (Unvented)0 18 ft² 0.1 Wood______WIC 2 Blown 5 Under Attic (Unvented)0 110 ft² 0.1 Wood______BEDROOM 2 Blown 6 Under Attic (Unvented)0 50 ft² 0.1 Wood______BATH 2 Blown 7 Under Attic (Unvented)0 44 ft² 0.1 Wood______HALL Blown 8 Under Attic (Unvented)0 65 ft² 0.1 Wood______M BATH Blown 9 Under Attic (Unvented)0 24 ft² 0.1 Wood______W/D Blown 10 Under Attic (Unvented)0 165 ft² 0.1 Wood______KITCHEN Blown 11 Under Attic (Unvented)0 165 ft² 0.1 Wood______LIVING RM Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0M WIC 0078 8NE Concrete Block - Int Insul 0.30Exterior68.7 ft² ____ 2 4.1 0M WIC 0007 8W Concrete Block - Int Insul 0.30Exterior56.0 ft² ____ 3 4.1 0MASTER BE 00105 8NE Concrete Block - Int Insul 0.30Exterior46.7 ft² ____ 4 4.1 0MASTER BE 00014 8W Concrete Block - Int Insul 0.30Exterior112.0 ft² ____ 5 4.1 0STORAGE00105 8NE Concrete Block - Int Insul 0.30Exterior46.7 ft² ____ 6 4.1 0WIC 2 00105 8NE Concrete Block - Int Insul 0.30Exterior46.7 ft² ____ 7 4.1 0WIC 2 0002 8E Concrete Block - Int Insul 0.30Exterior16.0 ft² ____ 8 4.1 0BEDROOM 2 00011 8E Concrete Block - Int Insul 0.30Exterior88.0 ft² ____ 11/3/2020 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 9 4.1 0BATH 2 0005 8E Concrete Block - Int Insul 0.30Exterior40.0 ft² ____ 10 4.1 0M BATH 00011 8W Concrete Block - Int Insul 0.30Exterior88.0 ft² ____ 11 4.1 0KITCHEN00011 8S Concrete Block - Int Insul 0.30Exterior88.0 ft² ____ 12 4.1 0KITCHEN00015 8W Concrete Block - Int Insul 0.30Exterior120.0 ft² ____ 13 4.1 0LIVING RM 00015 8E Concrete Block - Int Insul 0.30Exterior120.0 ft² ____ 14 4.1 0LIVING RM 00011 8S Concrete Block - Int Insul 0.30Exterior88.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .23 20 ft² None______NE STORAGE 863 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 NE Low-E Single 0.58 0.24 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes3 Y 2 W Low-E Single 0.58 0.24 16.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes4 Y 3 E Low-E Single 0.58 0.24 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes8 Y 4 E Low-E Single 0.58 0.24 4.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes9 Y 5 W Low-E Single 0.58 0.24 4.5 ft² 1 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes10 Y 6 S Low-E Single 0.58 0.24 4.5 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes11 Y 7 S Low-E Single 0.52 0.29 20.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes11 Y 8 E Low-E Single 0.58 0.24 16.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes13 Y 9 S Low-E Single 0.58 0.24 24.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes14 Y Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 816.7 744.83.000356Wholehouse .123384.32Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 17 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 18.8 kBtu/hr 564 cfm 0.8______sys#1Split1 Single 11/3/2020 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None STORAGE FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 125 ft² Attic 13 ft² Default Leakage Attic (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 STORAGE Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 W/D Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING RM 11/3/2020 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������