HomeMy WebLinkAbout48 Aqua Ra Dr Latham Deck Last 12-22-20NOTES:ALL LUMBER TO BE #2 PRESSURE TREATED S.Y.P.MATERIAL SUBSTITUTION ALLOWED IF PROVED TO BEEQUAL OR GREATER IN STRENGTH TO THAT SPECIFIEDDESIGN LOADS: 40 PSF LL, 10 PSF DLSTAINLESS STEEL (SS) FASTENERS REQUIRED FOR SSCONNECTORSALL FASTENERS SHALL BE HOT-DIPPED ZINC-COATEDGALVANIZED STEEL OR STAINLESS STEELSOIL LOAD BEARING STRENGTH ASSUMED AT 1500 PSFRAILING SHALL BE REQUIRED AROUND PERIMETER OFDECK EXCEPT FOR PORTION ABUTTING HOUSE(COMPLETE DECKS LOWER THAN 30" FROM FINISHEDGRADE ARE EXEMPT FROM THIS REQUIREMENT)DECKING SHALL HAVE 18" GAP BETWEEN DECK BOARDSSHEET INDEXAPPLICABLE BUILDING CODES1 OF 2 SHEETSDESIGN BY:DATE:DRAWN BY:CHECKED:REVISIONS:THIS DOCUMENT, SHEETNO. HAS BEEN PREPAREDSPECIFICALLY FOR THISPROJECT. THIS DOCUMENTIS NOT SUITABLE FOR USEON OTHER PROJECTS OR INOTHER LOCATIONSWITHOUT THE APPROVALAND PARTICIPATION OFCARDINAL ENGINEERINGASSOCIATES.UNAUTHORIZEDREPRODUCTION AND/ORREUSE IS PROHIBITED.2018 CARDINALENGINEERINGASSOCIATES, INC.JLJLJL12/10/20JOSEPH L. LAMMERS ,PEPE # 78477SHEET TITLE:RFLNo. 78477STATE OFRAIDOENSELI
CALENGI
NEERPROFESSION HPE
S
OJ
EMMALRSIVPROJECT SCOPE575 NW Mercantile PL,#106PORT ST. LUCIEFL 34986T.561.746.6343info@ceaengineers.comCA LIC. 31555LOCATION MAPNLOCATION MAPN.\18-02-14-00 Brkrs Ponce Mezz HVAC Replcmnt\811_CBYD_Hor_FullColor.jpg.jpgWILLIAM LATHEM48 AQUA RA DRJENSEN BEACH, FLBACKYARD DECK
PLANTERS2'-0"8'-0"7'-0"36'-0"15'-0"1'-6"5DECKING PLAN655551'-0"
2" MIN. - 6" MAX.3147'-0"<30"BASE FRAMING PROFILE258'-0"6'-4"7'-6"6'-0"7'-6"1111111111333344444222BASE FRAMING PLAN64" x 4" PT POST CENTERED ON 16" WIDE BY 12" DEEPSQUARE FOOTER W/ HETA20 CONNECTOR HAVING MIN. 6"EMBEDDMENT IN CONCRETE134252x10 PT LEDGER ATTACHED TO CONCRETE PAD USING 12DIA. ANCHOR BOLS W/ MIN. 3 1/4" EMBEDDMENT AND 24"SPACING (SEE DETAIL)(2) - 2X8 PT BEAM2X8 JOIST2X6 DECKING W/ 18" GAP BETWEEN EACH DECK BOARD6STAIRSJOIST STRING ATTACHMENT DETAILSLOPED JOIST HANGER FASTENERS TOBE INSTALLED PER MANUFACTURER'SRECOMMENDATIONSRIM JOIST OROUTSIDE JOISTSOLID SAWN ORMULTI-PLY BEAMPOST TO BEAMATTACHMENT JOIST HANGERFASTENERS TO BEINSTALLED PERMANUFACTURER'SRECOMMENDATIONTOP OF JOIST AND BEAMMUST BE ALIGNEDSTAGGER FASTENERS INTWO ROWSLEDGER BOARD FASTENER SPACINGMIN. 2"
5" MAX.LAG SCREW, THROUGHBOLT, OR CONCRETEANCHOR (MIN. 1//2" DIA.)(2)12" DIA. EXPANSION ANCHORATTACHMENT OF LEDGER BOARD TO FOUNDATION WALL24"STAIR RISER CONNECTION REQUIREMENTS2 OF 2 SHEETSDESIGN BY:DATE:DRAWN BY:CHECKED:REVISIONS:THIS DOCUMENT, SHEETNO. HAS BEEN PREPAREDSPECIFICALLY FOR THISPROJECT. THIS DOCUMENTIS NOT SUITABLE FOR USEON OTHER PROJECTS OR INOTHER LOCATIONSWITHOUT THE APPROVALAND PARTICIPATION OFCARDINAL ENGINEERINGASSOCIATES.UNAUTHORIZEDREPRODUCTION AND/ORREUSE IS PROHIBITED.2018 CARDINALENGINEERINGASSOCIATES, INC.JLJLJL12/10/20JOSEPH L. LAMMERS ,PEPE # 78477SHEET TITLE:RFLNo. 78477STATE OFRAIDOENSELI
CALENGIN
EERPROFESSION HPE
S
OJ
EMMALRSIV575 NW Mercantile PL,#106PORT ST. LUCIEFL 34986T.561.746.6343info@ceaengineers.comCA LIC. 31555WILLIAM LATHEM48 AQUA RA DRJENSEN BEACH, FLBACKYARD DECK