HomeMy WebLinkAboutEngineering, building plansPOOL SPECIFICATIONS 41'-10" 0 N N MAX. WIDTH 15' MAX.LENGTH 30' PERIMETER 81' AREA 364 sq.ft. MIN. DEPTH 3'0" MAX DEPTH 6'0" ACCESS RIGHT ELEV. TOB T.B.D. EXCAVATIED DIRT HAUL RAISED BEAM N/A TILE 6x6 STEP EDGE 2x6 COPING EDGE OVERPOUR INTERIOR FINISH GEM COAT SWIMOUT (2)6' LADDER N/A HANDRAIL NO GRAB RAIL NO FILTER PENTAIR C&C TIMECLOCK N/A CIRC. PUMP PENTAIR INTELLIFLO VS3050 POOL DRAIN 302 CHANNEL DRAIN MODEL#CMP25506-320 POOL RETURNS 4 VAC. LINE STUBOUT SKIMMER (1)TILED CHLORINATOR RAINBOW IN -LINE FILL LINE N/A OVERFLOW N/A WATERFEATURE (4)HYDRO JETS, (2)DECK JETS &(1)LED BUBBLER LIGHTS POOL (2) LED COLOR GLOBRITE ELECTRIC BY HORIZON TRANSFORMER YES J. BOX YES HEATER NO SIZE ------ btu GAS TYPE N/A TANK N/A HOOKUP BY N/A PATIO SPRAY DECK SQ FT ±756 TERMITE YES DONE BY BUGMAN EXISTING PATIO YES SQ FT ±80 DECK DRAIN 40' PLANTERS (2) APPROX. GALLONS 12,200 G.P.M. -- - TURNOVER 6 HR. 0 MIN. SCREEN ENCLOSURE YES FOOTERS YES CHILD BARRIER SPLASH GUARD ALARM & SCREEN ENCLOSURE ; JOB INFORMATION: HORIZON POOLS o JUNE RESIDENCE 8612 COBBLESTONE DR Q FT PIERCE, FL M. RANDALL RODGERS, P.E. FL License No.68212 1801 Hazelwood Drive Ft Pierce, FL 34982 (772)201-1634 Digitally signed by Marvin Marvin R R Rodgers DN: c=US, o=Unaffiliated, ou=A01410c000001725D M Rodgers cn=MarvinR Rodgers Date: 2020.11.11 17:14:27 -05,00, ***ELECTRIC NOT INCLUDED*** FBC 2017 Compliance NEC 2017 Compliance PREPARED BY: Jrittt, l : STEVE HORST 1 DRAFTING & DESIGN SERVICES (772)201-7846 horst.steve@yahoo.com 4 NOTE: REMOVE GRATE & Y" PER FT. MIN SLOPE WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL OVERPOUR OR CAP TILE WHERE APPLICABLE ' •:.:..i:.:,' .1 `4 6"x6" TILE —Pool construction complies with FBC 2017, ANSI-7, ANSI-15 GRATE SHALL 4" SLAB —Water Velocity -Max 8ft S2C / aS per FBC 2017-R4501.6.3 p BE SECURED IN INTERIOR 2500 FIBER MIX —Pool Y Barrier to comply with Section R4501.17-6th edition FBC PLACE SO THAT TOOLS FINISH" TYP. WALL-3,000 PSI GUNITE —Skimmers Comply with FBC 2017—R4501.21.2 ARE REQUIRED FOR REMOVAL STEEL—TEX FORM —Soil bearing capacity assumed 2,000psi @95% compaction :... OR KRAFr WALL 6" TYP. FLOOR —Equipment Foundation 3'x7' conc. slab min 3.5 thick pour In TRENCH DRAIN 3,000 PSI '. #3 @ 12" O.C.B.W. place or approved Hurricane Rated equipment GUNITE NOTE: FOR DEPTHS precast pads t; GREATER THAN 6' ADD TREADED PLUG .i:: (1)#3 COVE BAR @6" O.C. WHEN PROVIDED SHALL BE AT 20" MAX BELOW THE WATERLINE SWIMOUTS (NO SCALE) PRESSURE GAUGES INSTALLED ON FILTER PUMP FOR FINAL INSPECTION X 3�\ 0 N Vacuum (In Hg) X 1.13 Feet Of Head HYDRO —STATIC RELIEF DEVICE INSTALLED IN AREAS THAT EXCEED 1' WATER TABLE IN SHELL TO GRAVEL BED MAIN DRAIN POOL DETAIL (NO SCALE) `\u1111 .01 Ell Pressure (PSI) X 2.31 Feet Of Head Vacuum Head + Pressure Head = Total Dynamic Head #8 COPPER TO GRID HORIZONTAL INSTALL #8 COPPER TO GRID VERTICAL INSTALL PoolBond PB-2008 Install in Plumbing T at least 3" Below Water level in Return Piping.lnstall in sprinkler box for easy access WATER BOND DETAILS FOR NICHLESS LIGHT SYSTEM OUTSIDE ANGLE OF REPOSE 6' AND FURTHER — 4" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 3' TO 6' — 6" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 0' TO 3' — 8" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY 9 ft. 6 ft. J •. J J •, Q 00 P Y 0. Y MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2x6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HANDHOLD TO BE INSTALLED ARE WHERE DECK RAISED +6" ABOVE POOL a /'ec`<� EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE F� SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT * NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES * COMPACTION TEST OF THE BACKFILLED MATERIAL ARE PROVIDED PRIOR TO THE POURING OF THE PATIO X _ N WATERLINE N x a 0 0 V) 0 J N g" O X F O (V ° a. a c' A. °..4. 10" MIN(TYP) ° STEP DETAILS 1. TREAD IS MIN OF 10" WIDE. 2. BOTTOM & TOP RISERS MAY VARY IN HEIGHT 3. RISER NOT GREATER THAN 12" EXCEPT BOTTOM STEP WHERE DEPTH IS 4' OR GREATER 4. ALL STEPS TO BE SOLID GUNITE 3000 P.S.I. STEPS (NO SCALE) GRAVEL BE TO PUMP TYP. WALL SECTION & WELL POINT ................................................................ POOL LIGHT1 JUCTION BOX I WATER LEVEL UNDERWATER LIGHT YARD BY Z POOL PATIO EQUIPMENT z 12 VAC FROM POWER SUPPLY SIZE AS DETERMINED _2��ht' y: BY LICENSED ELECTRICIAN 14 POOL FINISH :.- ;,.:,. 1" PVC SCHEDULE 40 PVC SLEEVE CONDUIT NO BONDING OR GROUND REQUIRED NICHLESS UNDERWATER LIGHT DETAIL a • r-.�r, . R a • FOOTER DETAIL (NO SCALE) Y� 3 x3Z 01 _M_ CNANNEV �Rp,W PIPING SCHEMATIC CUSTOM MOLDED PRODUCTS INC. SINGLE CHANNEL DUAL OUTLET PER FRC4501.6.6 COMPLIANT WITH 2017 FLORIDA BUILDING CODE LISTED TO ASME/ANSI A112.19.8 32" CHANNEL DRAIN AND SUMP 25506-320-000 *THREE 2" SOCKET x 2.5" SPIGOT PORTS *DEBRIS GUARD INCLUDED *38.79in? OPEN AREA *IAMPO LISTED FLOW RATES *WHITE PVC BODY *COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (floor) and 192 GPM (wall) when using 2" plumbing. The maximum flow rating for this suction fitting with the outer ports plugged and the center port open is 200 GPM (floor) and 168 GPM (wall) when using 2.5" plumbing and 184 GPM (floor) and 176 GPM (wall) when using 2" plumbing. ' HAIR & MINER CMP 25506-32X VGB COMPLIANT 32" CHANNEL DRAIN www.horizonpools.net Wade M. Clarke Licensed & Insured Lic# RP-0067256 rizon POOLS, 114Cm NEW CONSTRUCTION & REMODELS 32 Years Expenence on the Treasure Coast Email: horizonpools@att.net Office: 772.405.1130 DECK LEVEL FLOOR M 1 ROW OF WATERLINE TILE WATERLINE — MAX 6' — �" LIGHT � 1 #3 STEEL @ 12" 0/C E.W. THICK 7 FLOOR SLOPES FLOOR SLOPE SHALL BE REASONABLY UNIFORM AND COMPLY WDH ARTICLES 5.6.1 THRU 5.6.3 THE SLOPE OF THE FLOOR FROM THE SHALOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FOOT 3'-0 JV —V TYPICAL SECTION THRU POOL (NO SCALE) WALLS SHALL NOT SLOPE GREATER THAN 11" Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer 1. Calculate Pool Volume: ___XXX ___ft_XXX_x 7.48(gal/Ft) = ___XXX ___gal (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: ___ XXX al XXX = XXX ___+___XXX - XXX (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate) Determine Pipe Sizes: Trunk Piping to be_ 3 __inch to keep velocity @ 8 fps max. at_ 181_gpm Maximum System Flow Rate. Return Piping to be — —!--inch __inch to keep velocity @ 8 fps max. at—Al—gpm Maximum System Flow Rate. Main Drain Cover(_____ SEE ABOVE) System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Drain Configuration Pipe Size 6 fps 8fps 1' 16 gpm 0.14' 21 gpm 0.23' 1.5' 37 gpm 0.08' 50 gpm 0.14' 2' 62 gpm 0.06' 82 gpm 0.10' 2,5' 88 gpm 0.05' 117 rn 0.09' 3' 136 gpm 0.04' 81 gpm 0.0_ 4 234 gpm 0.03' 313 gpm 05' 6' 534 gpm 0.02' 712 gpm 0,03' Pump Model PENTAIR INTELLIFLO VS3050 H.P. 3 Total H.P.=H.P.x service factor. 1 H.p. or more must be 2 speed or variable speed Filter Make PENTAIR C&C Size 150 Filter min. area based on 6hr. turnover flow rate pool gal. / 360 min. = Flow Rate Divide G.P.M. by Cartridge = .375 or Sand =15 or D.E. = 2 Time Controller make ON PUMP Model Controls must operate a minimum of two speeds. The higher seed override is not to exceed one normal cycle or 24 firs, whichever is less Determine Pipe Sizes: HYDROS ONLY Trunk Piping to be_3_inch to keep velocity @ 8 fps max. at_18?_gpm Maximum System Flow Rate. Return Piping to be-3_--inch to keep velocity @ 8 fps max. at_ 181 _gpm Maximum System Flow Rate. Main Drain Cover(_SEE ABOVE______) System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Drain Configuration Pipe Size 6 fps 8fps 1' 16 gpm 0.14' 21 gpm 0,23' 1.5' 37 gpm 0.08' 50 gpm 0.14' 2' 62 gpm 0.06' 82 gpm 0.10' 2.5' 88 gpm 0.05' 117 0.09' 3' 136 gpm 0.04' 181 gpm 0.07' 4' 234 gpm 0.03' 313 gpm 0.05' 6' 534 gpm 0.02' 712 gpm 0.03' TI OTl XTTT Tl n HORIZON POOLS JUNE RESIDENCE 8612 COBBLESTONE DR FT PIERCE, FL M. RANDALL RODGERS, P.E. FL License No. 68212 1801 Hazelwood Drive Ft Pierce, FL 34982 (772)201-1634 ***ELECTRIC NOT INCLUDED*** PREPARED BY: SHEET: STEVE HORST 3 DRAFTING & DESIGN SERVICES 4 (772)201-7846 horst.steve@yahoo.com TDH CALCULATOR HORIZON -DUNE -HIGH SPEED Pool Information Flow Rate: 125.2 GPM Total Piping Lengths: Suction Lift: 1.5 Ft Inlet Side: 46 Ft Discharge Side: 92 Ft Maximum Pipe Velocity Allowed: Piping Sizes: (consult your local code) Inlet Piping: 3.043 In li Inlet Piping: 8 FUSec Discharge Piping: 3.043 In Discharge Piping: 8 FUSec Piping Head Loss at 125.20 Gal/Min: (not incuding fittings or valves) Inlet Piping: 1.49 Ft Discharge Piping: 2.98 Ft For advanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer. This program is for single pump sytems with a single body of water. Results: Your TDH Calculation Required Minimum Pipe Sizes: Flow Rate: 125.20 Gal/Min Inlet Piping: 3.0 In Your Head Loss: 49.29 Ft Discharge Piping: 3.0 In Maximum Flow Rate at Maximum RPM: 125.20 Gal/Min Ensure the drain cover max flow rating is not exceeded. Head Loss at Maximum Flow Rate: 49.29 Ft System Head Pressure Curve 100 80 �y 60 40 20 IntelliFlo Variable Speed, VS+SVRS, VF, or VSF - 3400 rpm Clean System Desired operation Point 0c 0 50 100 150 Volumetric Flow Rate (GPM) Selected Components Components Head Loss at Name Quantity 125.20 Gal/Min 320 chlorinator 2 1 3.65 2" x 2.5" 3 way valve 6 20.94 Main Drain 1 2.48 Clean and Clear 1 10.41 Piping Inlet Discharge Head Loss at Name Quantity Quantity 125.20 Gal/Min 90 degree elbow 6 11 4.34 45 degree elbow 0 7 0.91 Tee Through 0 3 0.59 Pumps Name Quantity IntelliFlo Variable Speed, VS+SVRS, VF, 1 or VSF All Pentair trademarks and logos are owned by Pentair, Inc. IntelliFbOD, IntelliComm®, EasyTouchO, IntelliTouchO, SunTouchO, and Eco Select - are registered trademarks and/or trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pod and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties. Because we am continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. L--------------------------------------------------------------------------------------------. I I II I TDH CALCULATOR HORIZON-JUNE-LOW SPEED I I I I I I I I I I I I Pool Informatir+ I I Pool Volume: 13000 Gal Total Piping Lengths: Turn Over Time: 7.00 His Inlet Side: 46 Ft Suction Lift: 1.5 Ft Discharge Side: 92 Ft I I Maximum Pipe Velocity Allowed: Piping Sizes: (consult your local code) Inlet Piping: 3.043 In Inlet Piping: 8 FUSec Discharge Piping: 3.043 In Discharge Piping: 8 FUSec Piping Head Loss at 30.95 Gal/Min: I P 9 I (not incuding fittings or valves) Inlet Piping: 0.11 Ft j Discharge Piping: 0.22 Ft For advanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer. This program is for single pump sytems with a single body of water. Results: Your TDH Calculation I I I I Required Minimum Pipe Sizes: Flow Rate: 30.95 GaVMin Inlet Piping: 1.5 In Your Head Loss: 3.76 Ft Discharge Piping: 1.5 In Maximum Flow Rate j at Maximum RPM: 125.20 Gal/Min j Ensure the drain cover max now rating is not exceeded. Head Loss at Maximum Flow Rate: 49.29 Ft I I I I System Head Pressure Curve I I I I I I s I I I I I I I I I 5 I I I I I I I I I I � I I I I I I I I 3 I I I I I I I I 2 I I I I I I I I 1 � IntelliFlo Variable Speed, VS+SVRS, VF, or VSF - 800 rpm � Clean System Desired Operation Point 0 0 10 20 30 40 Volumetric Flow Rate (GPM) I I Selected Components I I I I I I I I I I Components Head Loss at Name Quantity 30.95 Gal/Min 320 chlorinator 2 1 0.32 2" x 2.5" 3 way valve 6 0.31 Main Drain 1 0.32 Clean and Clear 1 0.53 I I I I Piping Inlet Discharge Head Loss at Name Quantity Quantity 30.95 Gal/Min 90 degree elbow 6 11 0.33 45 degree elbow 0 7 0.07 j Tee Through 0 3 0.04 I I I I Pumps Name Quantity IntelliFlo Variable Speed, VS+SVRS, VF, 1 or VSF I I All Pentair trademarks and logos are owned by Pentair, Inc. IntelliFlo®, IntalliComm@, EasyTouch@, Intelin buch®, SunTouch®, and Eco Select - are registered trademarks and/or trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the I right to change specifications without prior notice. Pentair is an equal opportunity employer. I I I I I I I I I I I ELECTRICAL EQUIPMENT WIRING, GROUNDING AND INSTALLATION MUST CONFORM TO THE 2017 N.E.C. AND APPLICABLE LOCAL CODES 30" WIDE a 6'6" HIGH a 36" DEPTH CLEAR WORKING SPACE IN FRONT OF ANY PANEL BOARD PER 110.26(A), 110.26(2) AND 110.26(3) OF THE 2017 NATIONAL ELECTRIC CODE L NOTE: WATER PROOF G.F.I. MUST NOT BE MORE THAN 20' FROM POOL EDGE AND NOT WITHIN 6' OF POOL EDGE N.E.C. 2017 SEC. 680.22(3) POOL TIMER W/S.T. TOGGLE -SWITCH N.E.C. APPROVED 1" PVC CONDUIT - 3-#12 IN 1/2" CONDUIT #8 SOLID COPPER WIRE TO EOIAPOTENTIAL BOND #8 SOLID COPPER WIRE TO GROUND OPTIONAL 2ND LIGHT JUNCTION-BOX(S) MIN OF 8" ABOVE POOL DECK POOL W-L -#8 SOLID BARE COPPER . _ ...... _ . ........,JNT, PERIMETER BOND IRE WITH APPROVED CLAMPS 4" TO 6" BELOW SUB -GRADE BOND TO ENTIRE EQUIPMENT ALL-INGROUND .,,,.,,., POOLS 1-#8 SOLID BARE COPPER BOND WIRE WITH APPROVED CLAMPS ® (4) SIDES OF GUNITE POOLS BOND TO POOL STEEL TDH CALCULATOR HO RIZON -NNE -HYDROS Pool Information Pool Volume: 13000 Gal Total Piping Lengths: Turn Over Time: 7.00 His Inlet Side: 46 Ft Suction Lift: 1.5 Ft Discharge Side: 48 Ft Maximum Pipe Velocity Allowed: Piping Sizes: (consult your local code) Inlet Piping: 3.043 In Inlet Piping: 8 FUSec Discharge Piping: 3.043 In Discharge Piping: 8 FUSec Piping Head Loss at 30.95 Gal/Min: (not incuding fittings or valves) Inlet Piping: 0.11 Ft Discharge Piping: 0.12 Ft For advanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer. This program is for single pump sytems with a single body of water. Results: Your TDH Calculation Required Minimum Pipe Sizes: Flow Rate: 30.95 GallMin Inlet Piping: 1.5 In Your Head Loss: 3.64 Ft Discharge Piping: 1.5 In Maximum Flow Rate at Maximum RPM: 125.20 GaUMin Ensure the drain cover max now rating is not exceeded. Head Loss at Maximum Flow Rate: 47.73 Ft System Head Pressure Curve Lr4 0 I IntelliFlo Variable Speed, VS+SVRS, VF, or VSF - 800 rpm Clean System Desired Operation Point 0 10 20 30 40 Volumetric Flow Rate (GPM) SPlected Components Components Head Loss at Name Quantity 30.95 GallMin 320 chlorinator 2 1 0.32 2" x 2.5" 3 way valve 6 0.31 Main Drain 1 0.32 Clean and Clear 1 0.53 Piping Inlet Discharge Head Loss at Name Quantity Quantity 30.95 Gal/Min 90 degree elbow 6 13 0,36 45 degree elbow 0 2 0.02 Tee Through 0 3 0.04 Pumps Name Quantity IntelliFlo Variable Speed, VS+SVRS, VF, 1 or VSF All Pentair trademarks and logos are owned by Pentair, Inc. IntelliFlo®, IntelliComm®, EasyTouch®, IntelliTOUChtD, SunTouch®, and Eco Select - are registered trademarks and/or trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the li trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. L--------------------------------------------------------------------------------------------------JII ELECTRICAL DETAIL NOTE: ALL ELECTRICAL WORK SHALL CONFORM TO N.E.C. 2017 SEC. 680 EQUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTION OF THE N.E.C. 2017 SEC. 680.26