HomeMy WebLinkAboutEngineering, building plansPOOL SPECIFICATIONS
41'-10"
0
N
N
MAX. WIDTH 15'
MAX.LENGTH 30'
PERIMETER 81'
AREA 364 sq.ft.
MIN. DEPTH 3'0"
MAX DEPTH 6'0"
ACCESS RIGHT
ELEV. TOB T.B.D.
EXCAVATIED DIRT HAUL
RAISED BEAM N/A
TILE 6x6
STEP EDGE 2x6
COPING EDGE OVERPOUR
INTERIOR FINISH GEM COAT
SWIMOUT (2)6'
LADDER N/A
HANDRAIL NO
GRAB RAIL NO
FILTER PENTAIR C&C
TIMECLOCK N/A
CIRC. PUMP PENTAIR INTELLIFLO VS3050
POOL DRAIN 302 CHANNEL DRAIN
MODEL#CMP25506-320
POOL RETURNS 4 VAC. LINE STUBOUT
SKIMMER (1)TILED
CHLORINATOR RAINBOW IN -LINE
FILL LINE N/A OVERFLOW N/A
WATERFEATURE (4)HYDRO JETS, (2)DECK JETS
&(1)LED BUBBLER
LIGHTS POOL (2) LED COLOR GLOBRITE
ELECTRIC BY HORIZON
TRANSFORMER YES J. BOX YES
HEATER NO SIZE ------ btu
GAS TYPE N/A TANK N/A
HOOKUP BY N/A
PATIO SPRAY DECK SQ FT ±756
TERMITE YES DONE BY BUGMAN
EXISTING PATIO YES SQ FT ±80
DECK DRAIN 40' PLANTERS (2)
APPROX. GALLONS 12,200 G.P.M. --
- TURNOVER 6 HR. 0 MIN.
SCREEN ENCLOSURE YES FOOTERS YES
CHILD BARRIER SPLASH GUARD ALARM &
SCREEN ENCLOSURE
;
JOB INFORMATION:
HORIZON POOLS
o
JUNE RESIDENCE
8612 COBBLESTONE DR
Q
FT PIERCE, FL
M. RANDALL RODGERS, P.E.
FL License No.68212
1801 Hazelwood Drive
Ft Pierce, FL 34982
(772)201-1634
Digitally signed by Marvin
Marvin R
R Rodgers
DN: c=US, o=Unaffiliated,
ou=A01410c000001725D
M
Rodgers
cn=MarvinR Rodgers
Date: 2020.11.11 17:14:27
-05,00,
***ELECTRIC NOT INCLUDED***
FBC 2017 Compliance NEC 2017 Compliance
PREPARED BY: Jrittt, l :
STEVE HORST 1
DRAFTING & DESIGN SERVICES
(772)201-7846 horst.steve@yahoo.com 4
NOTE: REMOVE GRATE &
Y" PER FT. MIN SLOPE
WELL POINT PLUG FROM MAIN
DRAIN & ATTACH AUX. PUMP
LINE WHEN EMPTYING POOL
OVERPOUR OR CAP TILE
WHERE APPLICABLE ' •:.:..i:.:,' .1
`4
6"x6" TILE
—Pool
construction complies
with FBC 2017, ANSI-7, ANSI-15
GRATE SHALL
4" SLAB
—Water
Velocity -Max 8ft S2C
/
aS per FBC 2017-R4501.6.3
p
BE SECURED IN
INTERIOR
2500 FIBER MIX
—Pool
Y
Barrier to comply with
Section R4501.17-6th edition FBC
PLACE SO
THAT TOOLS
FINISH"
TYP. WALL-3,000 PSI GUNITE
—Skimmers Comply with FBC
2017—R4501.21.2
ARE REQUIRED
FOR REMOVAL
STEEL—TEX FORM
—Soil
bearing capacity assumed
2,000psi @95% compaction
:...
OR KRAFr WALL
6" TYP. FLOOR
—Equipment
Foundation 3'x7'
conc. slab min 3.5 thick pour In
TRENCH DRAIN
3,000 PSI
'.
#3 @ 12" O.C.B.W.
place
or approved Hurricane
Rated equipment
GUNITE
NOTE: FOR DEPTHS
precast pads
t;
GREATER THAN 6' ADD
TREADED
PLUG
.i::
(1)#3 COVE BAR @6" O.C.
WHEN PROVIDED
SHALL BE AT 20" MAX
BELOW THE
WATERLINE
SWIMOUTS
(NO SCALE)
PRESSURE GAUGES INSTALLED ON
FILTER PUMP FOR FINAL INSPECTION
X 3�\
0
N
Vacuum (In Hg) X 1.13
Feet Of Head
HYDRO —STATIC RELIEF
DEVICE INSTALLED IN
AREAS THAT EXCEED 1'
WATER TABLE IN SHELL
TO GRAVEL BED
MAIN DRAIN
POOL DETAIL
(NO SCALE)
`\u1111
.01 Ell
Pressure (PSI) X 2.31
Feet Of Head
Vacuum Head + Pressure Head
= Total Dynamic Head
#8 COPPER
TO GRID
HORIZONTAL INSTALL
#8 COPPER
TO GRID
VERTICAL INSTALL
PoolBond PB-2008
Install in Plumbing T at least 3" Below
Water level in Return Piping.lnstall
in sprinkler box for easy access
WATER BOND DETAILS FOR
NICHLESS LIGHT SYSTEM
OUTSIDE ANGLE OF REPOSE
6' AND FURTHER — 4" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY
3' TO 6' — 6" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY
0' TO 3' — 8" THICK WALLS W/#3 REBAR @12" O.C. EACH WAY
9 ft.
6 ft.
J
•. J
J •,
Q
00
P
Y
0.
Y
MISC. NOTES
1. ALL STEPS AND SWIMOUT BENCH EDGES
WILL HAVE 2x6 CAPTILE BORDER OF OPPOSITE
COLOR OF GEM FINISH FOR VISIBILITY
2. HANDHOLD TO BE INSTALLED ARE WHERE
DECK RAISED +6" ABOVE POOL
a
/'ec`<�
EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED:
SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE
F� SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT
* NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES
* COMPACTION TEST OF THE BACKFILLED MATERIAL ARE PROVIDED
PRIOR TO THE POURING OF THE PATIO
X
_ N WATERLINE
N
x
a
0
0
V) 0
J N g"
O X
F O (V ° a. a
c' A.
°..4. 10" MIN(TYP) °
STEP DETAILS
1. TREAD IS MIN OF 10" WIDE.
2. BOTTOM & TOP RISERS MAY VARY IN HEIGHT
3. RISER NOT GREATER THAN 12" EXCEPT BOTTOM
STEP WHERE DEPTH IS 4' OR GREATER
4. ALL STEPS TO BE SOLID GUNITE 3000 P.S.I.
STEPS
(NO SCALE)
GRAVEL BE TO PUMP
TYP. WALL SECTION & WELL POINT
................................................................
POOL LIGHT1
JUCTION BOX I
WATER LEVEL
UNDERWATER
LIGHT
YARD BY
Z POOL PATIO EQUIPMENT
z 12 VAC FROM
POWER SUPPLY
SIZE AS DETERMINED
_2��ht' y:
BY LICENSED ELECTRICIAN 14
POOL FINISH :.-
;,.:,. 1" PVC
SCHEDULE 40 PVC SLEEVE CONDUIT
NO BONDING
OR GROUND
REQUIRED
NICHLESS UNDERWATER LIGHT DETAIL
a
•
r-.�r, . R
a
•
FOOTER DETAIL
(NO SCALE)
Y� 3 x3Z 01 _M_
CNANNEV �Rp,W
PIPING SCHEMATIC
CUSTOM MOLDED PRODUCTS INC.
SINGLE CHANNEL DUAL OUTLET
PER FRC4501.6.6
COMPLIANT WITH
2017 FLORIDA BUILDING CODE
LISTED TO ASME/ANSI A112.19.8
32" CHANNEL DRAIN AND SUMP
25506-320-000
*THREE 2" SOCKET x 2.5" SPIGOT PORTS
*DEBRIS GUARD INCLUDED
*38.79in? OPEN AREA
*IAMPO LISTED FLOW RATES
*WHITE PVC BODY
*COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP
The maximum flow rating for this suction fitting with the center port plugged and outer ports
open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (floor)
and 192 GPM (wall) when using 2" plumbing. The maximum flow rating for this suction
fitting with the outer ports plugged and the center port open is 200 GPM (floor) and 168 GPM
(wall) when using 2.5" plumbing and 184 GPM (floor) and 176 GPM (wall) when using 2" plumbing.
' HAIR &
MINER
CMP 25506-32X VGB
COMPLIANT 32" CHANNEL DRAIN
www.horizonpools.net Wade M. Clarke
Licensed & Insured
Lic# RP-0067256
rizon
POOLS, 114Cm
NEW CONSTRUCTION & REMODELS
32 Years Expenence on the Treasure Coast
Email: horizonpools@att.net Office: 772.405.1130
DECK
LEVEL FLOOR
M
1 ROW OF WATERLINE TILE
WATERLINE —
MAX 6' — �" LIGHT
� 1 #3 STEEL @ 12" 0/C E.W.
THICK 7
FLOOR SLOPES
FLOOR SLOPE SHALL BE
REASONABLY UNIFORM AND
COMPLY WDH ARTICLES 5.6.1
THRU 5.6.3
THE SLOPE OF THE FLOOR FROM
THE SHALOW END WALL
TOWARDS THE DEEP AREA SHALL
NOT EXCEED 1 FOOT IN 7 FOOT
3'-0
JV —V
TYPICAL SECTION THRU POOL
(NO SCALE)
WALLS
SHALL
NOT
SLOPE
GREATER
THAN 11"
Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer
1. Calculate Pool Volume: ___XXX ___ft_XXX_x 7.48(gal/Ft) = ___XXX ___gal
(Surface Area) (Average Depth) (Volume in gallons)
2. Determine Flow Rate: ___ XXX al XXX = XXX ___+___XXX - XXX
(Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate)
Determine Pipe Sizes:
Trunk Piping to be_ 3 __inch to keep velocity @ 8 fps max. at_ 181_gpm Maximum System Flow Rate.
Return Piping to be — —!--inch __inch to keep velocity @ 8 fps max. at—Al—gpm Maximum System Flow Rate.
Main Drain Cover(_____ SEE ABOVE) System Flow Rate must not exceed approved cover flow rate.
(Make and Model) See Engineering Page for Drain Configuration
Pipe Size
6 fps
8fps
1'
16
gpm
0.14'
21
gpm
0.23'
1.5'
37
gpm
0.08'
50
gpm
0.14'
2'
62
gpm
0.06'
82
gpm
0.10'
2,5'
88
gpm
0.05'
117
rn
0.09'
3'
136
gpm
0.04'
81
gpm
0.0_
4
234
gpm
0.03'
313
gpm
05'
6'
534
gpm
0.02'
712
gpm
0,03'
Pump Model PENTAIR INTELLIFLO VS3050 H.P. 3
Total H.P.=H.P.x service factor. 1 H.p. or more must be 2 speed or variable speed
Filter Make PENTAIR C&C Size 150
Filter min. area based on 6hr. turnover flow rate pool gal. / 360 min. = Flow Rate
Divide G.P.M. by Cartridge = .375 or Sand =15 or D.E. = 2
Time Controller make ON PUMP Model
Controls must operate a minimum of two speeds.
The higher seed override is not to exceed one normal cycle or 24 firs, whichever is less
Determine Pipe Sizes: HYDROS ONLY
Trunk Piping to be_3_inch to keep velocity @ 8 fps max. at_18?_gpm Maximum System Flow Rate.
Return Piping to be-3_--inch to keep velocity @ 8 fps max. at_ 181 _gpm Maximum System Flow Rate.
Main Drain Cover(_SEE ABOVE______) System Flow Rate must not exceed approved cover flow rate.
(Make and Model) See Engineering Page for Drain Configuration
Pipe Size
6 fps
8fps
1'
16
gpm
0.14'
21
gpm
0,23'
1.5'
37
gpm
0.08'
50
gpm
0.14'
2'
62
gpm
0.06'
82
gpm
0.10'
2.5'
88
gpm
0.05'
117
0.09'
3'
136
gpm
0.04'
181
gpm
0.07'
4'
234
gpm
0.03'
313
gpm
0.05'
6'
534
gpm
0.02'
712
gpm
0.03'
TI OTl XTTT Tl n
HORIZON POOLS
JUNE RESIDENCE
8612 COBBLESTONE DR
FT PIERCE, FL
M. RANDALL RODGERS, P.E.
FL License No. 68212
1801 Hazelwood Drive
Ft Pierce, FL 34982
(772)201-1634
***ELECTRIC NOT INCLUDED***
PREPARED BY: SHEET:
STEVE HORST 3
DRAFTING &
DESIGN SERVICES 4
(772)201-7846 horst.steve@yahoo.com
TDH CALCULATOR HORIZON -DUNE -HIGH SPEED
Pool Information
Flow Rate: 125.2 GPM
Total Piping Lengths:
Suction Lift: 1.5 Ft
Inlet Side: 46 Ft
Discharge Side: 92 Ft
Maximum Pipe Velocity Allowed:
Piping Sizes:
(consult your local code)
Inlet Piping: 3.043 In
li Inlet Piping: 8 FUSec
Discharge Piping: 3.043 In
Discharge Piping: 8 FUSec
Piping Head Loss at 125.20 Gal/Min:
(not incuding fittings or valves)
Inlet Piping: 1.49 Ft
Discharge Piping: 2.98 Ft
For advanced pools that contain multiple suctions, this program may be
inaccurate. Consult a hydraulics engineer. This program is for single pump
sytems with a single body of water.
Results: Your TDH Calculation
Required Minimum Pipe Sizes:
Flow Rate: 125.20 Gal/Min
Inlet Piping: 3.0 In
Your Head Loss: 49.29 Ft
Discharge Piping: 3.0 In
Maximum Flow Rate
at Maximum RPM: 125.20 Gal/Min
Ensure the drain cover max flow rating is not
exceeded.
Head Loss at
Maximum Flow Rate: 49.29 Ft
System Head Pressure Curve
100
80
�y
60
40
20
IntelliFlo Variable Speed, VS+SVRS, VF, or VSF - 3400 rpm
Clean System
Desired operation Point
0c
0 50 100 150
Volumetric Flow Rate (GPM)
Selected Components
Components
Head Loss at
Name Quantity 125.20 Gal/Min
320 chlorinator 2 1 3.65
2" x 2.5" 3 way valve 6 20.94
Main Drain 1 2.48
Clean and Clear 1 10.41
Piping
Inlet Discharge Head Loss at
Name Quantity Quantity 125.20 Gal/Min
90 degree elbow 6 11 4.34
45 degree elbow 0 7 0.91
Tee Through 0 3 0.59
Pumps
Name Quantity
IntelliFlo Variable Speed, VS+SVRS, VF, 1
or VSF
All Pentair trademarks and logos are owned by Pentair, Inc. IntelliFbOD, IntelliComm®, EasyTouchO, IntelliTouchO, SunTouchO, and Eco Select -
are registered trademarks and/or trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other
countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or
endorsement between the owners of these names and brands and Pentair Water Pod and Spa, Inc. Those names and brands may be the
trademarks or registered trademarks of those third parties. Because we am continuously improving our products and services, Pentair reserves the
right to change specifications without prior notice. Pentair is an equal opportunity employer.
L--------------------------------------------------------------------------------------------.
I I
II I
TDH CALCULATOR HORIZON-JUNE-LOW SPEED
I I
I I
I I
I
I
I I
I I
Pool Informatir+
I I
Pool Volume: 13000 Gal Total Piping Lengths:
Turn Over Time: 7.00 His Inlet Side: 46 Ft
Suction Lift: 1.5 Ft Discharge Side: 92 Ft
I I
Maximum Pipe Velocity Allowed: Piping Sizes:
(consult your local code) Inlet Piping: 3.043 In
Inlet Piping: 8 FUSec Discharge Piping: 3.043 In
Discharge Piping: 8 FUSec Piping Head Loss at 30.95 Gal/Min:
I P 9 I
(not incuding fittings or valves)
Inlet Piping: 0.11 Ft j
Discharge Piping: 0.22 Ft
For advanced pools that contain multiple suctions, this program may be
inaccurate. Consult a hydraulics engineer. This program is for single pump
sytems with a single body of water.
Results: Your TDH Calculation
I I
I I
Required Minimum Pipe Sizes:
Flow Rate: 30.95 GaVMin Inlet Piping: 1.5 In
Your Head Loss: 3.76 Ft Discharge Piping: 1.5 In
Maximum Flow Rate
j at Maximum RPM: 125.20 Gal/Min j
Ensure the drain cover max now rating is not
exceeded.
Head Loss at
Maximum Flow Rate: 49.29 Ft
I I
I I
System Head Pressure Curve
I
I I
I I
I s I
I I
I I
I I
I I
5
I
I I
I I
I I
I I
I � I
I I
I I
I I
I 3 I
I I
I
I I
I I
2
I I
I I
I I
I I
1
� IntelliFlo Variable Speed, VS+SVRS, VF, or VSF - 800 rpm �
Clean System
Desired Operation Point
0
0 10 20 30 40
Volumetric Flow Rate (GPM)
I I
Selected Components
I I
I I
I I
I I
I I
Components
Head Loss at
Name Quantity 30.95 Gal/Min
320 chlorinator 2 1 0.32
2" x 2.5" 3 way valve 6 0.31
Main Drain 1 0.32
Clean and Clear 1 0.53
I I
I I
Piping
Inlet Discharge Head Loss at
Name Quantity Quantity 30.95 Gal/Min
90 degree elbow 6 11 0.33
45 degree elbow 0 7 0.07
j Tee Through 0 3 0.04
I I
I I
Pumps
Name Quantity
IntelliFlo Variable Speed, VS+SVRS, VF, 1
or VSF
I I
All Pentair trademarks and logos are owned by Pentair, Inc. IntelliFlo®, IntalliComm@, EasyTouch@, Intelin buch®, SunTouch®, and Eco Select -
are registered trademarks and/or trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other
countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or
endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the
trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the
I right to change specifications without prior notice. Pentair is an equal opportunity employer. I
I I
I I
I I
I I
I I
ELECTRICAL EQUIPMENT WIRING, GROUNDING AND INSTALLATION MUST
CONFORM TO THE 2017 N.E.C. AND APPLICABLE LOCAL CODES
30" WIDE a 6'6" HIGH a 36" DEPTH CLEAR WORKING SPACE IN
FRONT OF ANY PANEL BOARD PER 110.26(A), 110.26(2)
AND 110.26(3) OF THE 2017 NATIONAL ELECTRIC CODE
L NOTE:
WATER PROOF G.F.I.
MUST NOT BE MORE
THAN 20' FROM POOL
EDGE AND NOT
WITHIN 6' OF POOL EDGE
N.E.C. 2017 SEC. 680.22(3)
POOL TIMER W/S.T.
TOGGLE -SWITCH
N.E.C. APPROVED
1" PVC CONDUIT
- 3-#12 IN
1/2" CONDUIT
#8 SOLID COPPER WIRE
TO EOIAPOTENTIAL BOND
#8 SOLID COPPER
WIRE TO GROUND
OPTIONAL 2ND LIGHT
JUNCTION-BOX(S)
MIN OF 8"
ABOVE POOL DECK
POOL
W-L
-#8 SOLID BARE COPPER
. _ ...... _ . ........,JNT, PERIMETER BOND
IRE WITH APPROVED
CLAMPS 4" TO 6" BELOW
SUB -GRADE BOND TO
ENTIRE EQUIPMENT ALL-INGROUND
.,,,.,,., POOLS
1-#8 SOLID BARE COPPER
BOND WIRE WITH APPROVED
CLAMPS ® (4) SIDES OF
GUNITE POOLS BOND TO
POOL STEEL
TDH CALCULATOR HO
RIZON -NNE -HYDROS
Pool Information
Pool Volume: 13000 Gal
Total Piping Lengths:
Turn Over Time: 7.00 His
Inlet Side: 46 Ft
Suction Lift: 1.5 Ft
Discharge Side: 48 Ft
Maximum Pipe Velocity Allowed:
Piping Sizes:
(consult your local code)
Inlet Piping: 3.043 In
Inlet Piping: 8 FUSec
Discharge Piping: 3.043 In
Discharge Piping: 8 FUSec
Piping Head Loss at 30.95 Gal/Min:
(not incuding fittings or valves)
Inlet Piping: 0.11 Ft
Discharge Piping: 0.12 Ft
For advanced pools that contain multiple suctions, this program may be
inaccurate. Consult a hydraulics engineer. This program is for single pump
sytems with a single body of water.
Results: Your TDH Calculation
Required Minimum Pipe Sizes:
Flow Rate: 30.95 GallMin
Inlet Piping: 1.5 In
Your Head Loss: 3.64 Ft
Discharge Piping: 1.5 In
Maximum Flow Rate
at Maximum RPM: 125.20 GaUMin
Ensure the drain cover max now rating is not
exceeded.
Head Loss at
Maximum Flow Rate: 47.73 Ft
System Head Pressure Curve
Lr4
0 I IntelliFlo Variable Speed, VS+SVRS, VF, or VSF - 800 rpm
Clean System
Desired Operation Point
0 10 20 30 40
Volumetric Flow Rate (GPM)
SPlected Components
Components
Head Loss at
Name Quantity 30.95 GallMin
320 chlorinator 2 1 0.32
2" x 2.5" 3 way valve 6 0.31
Main Drain 1 0.32
Clean and Clear 1 0.53
Piping
Inlet Discharge Head Loss at
Name Quantity Quantity 30.95 Gal/Min
90 degree elbow 6 13 0,36
45 degree elbow 0 2 0.02
Tee Through 0 3 0.04
Pumps
Name Quantity
IntelliFlo Variable Speed, VS+SVRS, VF, 1
or VSF
All Pentair trademarks and logos are owned by Pentair, Inc. IntelliFlo®, IntelliComm®, EasyTouch®, IntelliTOUChtD, SunTouch®, and Eco Select -
are registered trademarks and/or trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other
countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or
endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the
li trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the
right to change specifications without prior notice. Pentair is an equal opportunity employer.
L--------------------------------------------------------------------------------------------------JII
ELECTRICAL DETAIL
NOTE: ALL ELECTRICAL WORK SHALL
CONFORM TO N.E.C. 2017 SEC. 680
EQUIPOTENTIAL BONDING DETAIL
PER FLORIDA BUILDING CODE ADAPTION
OF THE N.E.C. 2017 SEC. 680.26