Loading...
HomeMy WebLinkAboutBuilding PlansCONTRACTOR: South Florida Aluminum Products, Inc. DESIGN CRITERIA: 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and AA ADM Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-10. Loading Criteria 1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section 105.1 2. Dead Load: 2 PSF 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 3.2. Ultimate Design Wind Speed: VULT =150 MPH, Nominal Design Wind Speed: VASD =116 MPH 3.3. Exposure Category, Section 1609.4.3: Exposure C 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1- Patio Cover Non -Habitable, Unconditioned Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.024" Structall Foundation Existing concrete. No additional concrete footing or slab is required to resist the Ioads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition. free from structural WIND SPEED AND EXPOSURE HAVE BEEN DETERMINED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. 3X3XO.125 POST 0 I io 3X3XO.125 T POST The following specifications are applicable to this project: 1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Florida Aluminum Engineering, Inc. 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 4. Approved concrete screw anchors to be Simpson Titen-HD or equivalent. 5. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or # 12 screws 6" from ends and 12" center to center. 6. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1% - ASTM C 260 iv.Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after batching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All flashing and weatherproofing shall be provided by the contractor. 8. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. 0 I 0 I 2X5SMB 2X3 4TH WALL 2X3 END 3"X4B"XO.024" BEAM END BEAM 1.0# DENSITY FOAM BEAM COMPOSITE PANEL 2X5SMB kg EDGE BEAM A-2 Zd'_i:• 2X3K.B. (TYP) to 3X3XO.125 I POST 0 POST 125 11 / POST0125 POST0.125 POST A-2 B'-7n 8'-7j" B'-7n B'-7n mCevED �Ov 2 510 a MIttln9 G Qeo rlty St. kucle POST 125 POST 0 0 6 of 3X3XO.125 POST 10'—S" 3X3XO.125 POST 0 ;W m (L : v iz SPY �l�l -65� REV EWED FOR CODE COMPLIANCE ST. LUCIE CO p BOCC��11TIIN W UI W d Z c» 0 W Z —J Z Q Z O a n N Z H W W O J W O = cc � a V Z? Z t, � a� LL^^ s Q W ,�,ia00m LU � Vr � c a OJ LLI Z 9 u. F— o' O m W LA W j oMW f yQ Z U U V Z J W W_ 0_F—cV �� O < C:) Of�00LL TP DATE DRAWN 11 /04/19 REVISION A-1 ALUMINUM MEMBERS I)BUNSIONS 11111I///// `,`,,r♦gllll HOLLOW SECTIONS %%%,� �iI 2x2: 2"x2"x0.046" 2x3: 2"x3"x0.050" \\\ ,.••• REVIEWED 1=0R �:/ ,•' �� •• •,•• 2x4: 2"x4"xo.050„ `� _ • 2 x 5: 2' x 5, x 0.050" AA 1 1/2 GAGE ON � = ; � � CODE COMPLIANCE 2. 6' 0 F- - SCREW ANCHORS ; : z C> 0 OPEN BACK SECTIONS ® ® B W ST. LUCIE COUNTY z a w o: ¢ = I x 2: 1" x 2" x 0.040" ® ® ; v " N Q 1 x 3: 1" x 3" x 0.045" _ L J �e /� BOCC i ! O 0) 4v%; SNAP SECTIONS 3"x 3"x 0.125" #14x4"SMSW/ 1 1/2" DIA. NEOPRENE ��fi •'.�• Z 2 x 2 Snap: 2" x 2" x 0.045" POST FACED WASHER @ 6" O.C. I� . • •. I'�/I �. •' `v \\ ..•• 2 x 3 Snapp: 2"x3"x0.050";!G ,� Q�f'�,``\\\ 2x4Sna 2"x4"x0.045"JK r4=, 'i••�` �/IIIIII , • r� 1111��� SELF MATING (SMB)::�*,.w�'�e�•^''„q •r•1� •q;Sfa,J;x•r"lrii'• `yt .ti •(`xkE..�e3r'�h7y �'�': '',. t: .•'. .�,'1�x•yJ•l ri.. 2 x 4 SMB: 2" x 4" x 0.044" x 0.100" " �:4�''G°�i�ir: •i'l e' nt .'ai.'`ne, :J,.,,(,-•`4''....M..n, ,�.'. 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" 2 x 6 SUB: 2" x 6" x 0.050" x 0.120" A A-] I I I W W LLI 2 x 7 SMB: 2" x 7".x 0.057" x 0.120" 2 x 8 SMB: 2" x 8" x 0.072" x 0.124" I I 3" x 3" x 1/8" ALUM FLANGED 3" COMPOSITE I ROOF PANEL z _. 2 x 9 SMB: 2" x 9" x 0.072" x 0.124'> I POST BASE W1(2) 3/8" DIA. THRU 3" x 0.062" ALUM z 2 x 10 SMB: 2" x 10" x 0.092" x 0.398'> 3" x 3" x 0.125" I BOLTS INTO POST & (4) 3l8" DIA. x 31/2" EMBEDMENT CONCRETE RECEIVING CHANNEL Wl #10 x 3/4" TOP AND (3) 30' DIA. W z MINIMUM FASTENER EDGE DISTANCE: 1/2" POST SCREW ANCHORS INTO CONCRETE BOTTOM AS END CAP THRU BOLTS I I J Q Q O z z MINIMUM FASTENER SPACING: 3/4" I I % a LLA 2" x 5" SMB N z CONCRETE SCREW ANCHOR: ' a a n° I x 0.125" VV) V SIMPSON TITEN HD OR EQUIVALENT A a I I POST J SHEET METAL SCREWS (SMS): d O ITW / BUILDEX OR EQUIVALENT ap f -2"-+a 2" I cc 2 I - B S COMPOSITE ROOF TO POST CONNECTION z - 0 3" x 3" POST TO CONCRETE CONNECTION SCALE: NTS DETAIL A_2 SCALE: NTS j r A-2 z Q W m<`.�'a IN LLJZ ig LL Q 0 a g O W LL #14 x 4" SMS W/ 1 1/2" DIA. NEOPRENE FACED WASHER @ 6" O.C. FLASHING #14 SMS x 1" MIN. LONGER BY OTHERS 3" COMPOSITE ROOF PANEL THAN PANEL W/ 1 1/2" DIA #14 SMS x 1"MIN. LONGER NEOPRENE FACED WASHER 3" COMPOSITE #14 x 4" SMS W/ THAN PANEL W/ 1 1/2" DIA. H Ix @ 12" O.C. ALONG LENGTH ROOF PANEL 1 1/2" DIA. NEOPRENE NEOPRENE FACED WASHER 0 FLASHING OF ALL END BEAMS FACED WASHER @ 6" O.C. @ 12" O.C. ALONG LENGTH BY OTHERS =is ~ ' I OF ALL END BEAMS Lll - • • �� + 5 , Y.,h 4't:`s` V7 3„ COMPOSITE ROOF PANEL A„tin,.d.hi.:;:�.:>�>�;A,�.',`v}},.'.-;% :.. ,.^rsa:.}p�. d."k��s3ta...fT+:; �d'.+.a::ixr rr,_; ".T,,:`T!-.:r:t.; 1::.�{;.11e;�•;!h5w4y;.:•� ,P ..i:s.r.Cl•i.n•.. .n�; \?f?.:.tiw'-h„%,'�r•,4�,�,•e�;i 4�r�yf�yiti+os•:i�:ya,4.,;.�'a^•^• `.'.}.:,Y •>a:�r� ,S?.'. r... .. .""''[ a�:J'f.t5". �Ssy'.x}y`... ,, •4�.�.�,f`•i••`:S�d;<S!•. �-.n<.�`S.ik �'"•,', �` "�� W Vi>Loa La Q Y.. � I fx.��..Y�:i �:�l;ruin« rn�vr: �j,*•`__• t� ,r. •':.,M1..�''�^` '; b0.:���'-�.•=f1,��.?a n 2"x3"x0.050" a I END BEAM • EXG ISTIN BUILDING +chf'a•�R`' _ -^ �- . ' 1 • -' • 2"x3"x0.046" I • END BEAM � a W W W 3" x 0.062" ALUM • _ _ _ _ -- - I I LLJ (O 0 #14x4"SMSW/ I 11/8"x21/7'x11/8"x0.125" 1 _ RECEIVING CHANNEL ^ Q d 11/2"DIA. NEOPRENE EXISTING ALUM RECEIVING CHANNEL I Wl #10 x 3/4" TOP AND I O Q p H F- M FACED WASHER @ 4" O.C. (R 3/8" DIA. THRU BOLTS BUILDING I W/ (3) #12 x 314" SMS EACH I I BEAM 8 (T E P DIA. SIDE BOLTS THRU BOLTS INTO THE POST I 3/8" DIA THRU BOLT I 1 BOTTOM AS END CAP I 1 1l2" x 21/8"x 1 1/2" x 0.062" x 3" LONG 3/8" DIA. ALUM RECEIVING CHANNEL W/ (3) THRU BOLTS I #14 x 3/4" SMS EACH SIDE OF (3 TOTAL) BEAM & (2) 30DIA. THRU BOLTS 0 O O � C. � U) .J LL LL DRAWN BY 2"x5"SMB I (3 TOTAL) I I I INTO POST TP1 W x 3" x b.125" 2" x 5" sM6 I 2" ' SM B x SI I DATE DRAWN POST - - 3" x 3" x 0.125" - - - I I 11 /04/19 POST 3" x 3" x 0.126' REVISION POST 1 _ 2 S-2 COMP. ROOF TO CORNER POST 4TH WALL DETAIL S-1 COMPOSITE ROOF TO POST 0 4TH WALL DETAIL /�-2 SCALE: NTS S-3 COMPOSITE ROOF TO POST CORNER CONNECTION _ A-2 SCALE: NTS A -2 SCALE: NTS SHEET NO: A-2 I f,,ffff11111111f////II o 0 w co * W If. � - Q- " 0 co :,= If Ise Y III//fff1f111111Nff W W W d H Q W LLI LL d REVIEWEDC z Z o z~ CODE COMPLIAtr: zm wlN ZO � �`".►d ST" LUCID z _ . Q m < "rj ',9 R` U3 NJ Z g °`°„a .. d_ z � dud z 9 JO Lu LL 3" COMP ROOF PANEL -SELF -MATING BEAM �a�^�-ri_�-.y-�' .•,K�,�'•5+`S1.i=i:1^iti1�'a��:o�f`.yt�."\^•r^:l"Ki:2:.���::.�tt::a(ur..-i�,�.,r��..;-4,..�, • •�c'�.;a• _.tfl' � 4 l� s„� :t .41,;c�iif:�•L: �:..+''i ,:4 �;ti-.JJ.. ,•.','�• .!r' N•J ay... :txtti`ti e"f i;.�. n. ..+:.�1., a)�Y �@,A�. -"F V, ..:!L�p h.�.yO�V�. ry.4�• i• t'et :�'..r:[t�4.• .�� CiK M•u• .'n�M ••H � `'•.�Yy4 J' � J+k -�:+.e flint•., r•v�:.,j;l �L. f'�• i.•,h T� "y nA7•i4�" �S :•eJ! !"f.: ry 'i is :.� '�i ^'•n,"i.^:,X('•• rJ•Je -i'V'• ".�': ^K:.Ra .!'.?4•tt". r~� �L .:L r d,.c .+:,:.e �.x .+,w••r•Air ��...,.4.�f� O w I I II "' I I o ® • I I i- m w W Q Z 0 U \\ \ I I � � w \ I I \ I I W x t- c� "T - %aCoCL \\ \ cn 12„ \ I I w O uC)i 0 0 2" x 3" x 0.046" \ \ a W Lo-1 u^ U_ KNEE BRACE \ I ( UPRIGHT DRAWN BY \0 LI TP 11/2"x21/6"x11/2"x I DATE DRAWN 0.062" x 3" LONG ALUM I 11 /04/19 RECEIVING CHANNEL W/ (3) #12 x 3/4"SMS EA. FACE & I I REVISION (3) #12 x 3/4" INTO POST I I I 1 _ S-4 KNEE BRACE CONNECTION DETAIL 4 SHEET NO: � -3 SCALE: NTS A-31