FL d FL5259-R29
Application Type Revision
Code Version 2012
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ez[242
malpert@polyglass.cam
Authonzed Signature Maury Alpert
maipert@polyglass.mm
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866) 802-8017
uspolyglasstechnleal@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1325
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Undedayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Han copy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/21/2022
Validated By lohn W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence EB259 R29 CDI 2019 01 COI NI MIM1' N lit
Referenced Standard and Year (of Standard) £traderd Ym
ASTM D1920 2015
ASTM D226 2009
ASTM D4198 2011
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2009
FM 4424 2011
FRSA/TRI April 2012 2012
UL 1892 2012
Equivalence of Product Standards
Certified By
Sectlons from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2019
Date Validated 10/16/2019
Date Pending FBC Approval 10/20/2019
Date Approved IZ/10/2019
Summary a PpduQE
FL •
Mode�m� Name
Description
5259.1
Polygl
Roofing untlerlayments
U derl
Limits of use
Installation Instructions
Approved for use in NVHZ: No
Approved for use outside HVHZ: Yes
RZ259 R29 II 2019 10 FIMAL eR POLY0L,4SS UNDEBIAYMENTg;
922adff
Impact Resistant: N/A
Design Pressure: +N/A/-622.5
Other: 1.) The design pressure in this
application relates to one particular
underlayment system (aver roncrete deck) for
Verified By: Robert Niernmen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FB259 R29 AE 2012 10 FINAL r: Aoc UNDERI AYMENTS FL5259-
R21pol
use under foam -on ble systems (where Me
underlayment forms part of Me load -path).
Created by Independent Third Party: Yes
Refer t9 ER Section 5.6.1 for other systems,
other tleck types and a oodated mazlmum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
gppta ee :: M.1 .,It t, an, Talla�hseste R o, more.
Tae Sete W name le an A - employe[ r' -2013 aleve ef hotels :: Mvac 52[e [:: agt55MLty Stet my rptPNu�M se -loam �,
.man aamesee
��A
with sh emeu adds a vh.h ean ae made avallade M the puMlc A ove{me
erect'.. epprove. G su:
MW1®o®
Credit Card
Safe
NEMOletc.
Certi&ate ofAuNwnzaNan X32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R25
1111 West Newport Center Drive FI5259-R29
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1230 Revision 25: 10/14/2019
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the V Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: POlyglass Raof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 16.
Prepared by:--
e
f
Robert J.M. Nieminen, P.E.
>
Florida Registration No. 59166, Florida DC4 ANE1983
�Q•M•.n•�""'; The r,mn,im see izwe.,mr was aumod:m by apnea Nien,men,IX. on
10n4/2019. This don not fery zs on eietboninil sl Mdo,unnent
CEMIFIGTION OF INDEPENDENCE:
1. NEMOletc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOletc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing ordistributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, norwill acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019NEMOETC,LLC
WNEMOIetc.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 6v Edition (2017) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
`2. STANDARDS:
Section
Proert
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3/ 1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4/ 1507.1.1,1507.2.9.2
Physical Propertles
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM M163
2008
1507.11.2
Physical Properties
ASTM 06164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
1507.11.2
Physical Properties
ASTM D65M
2009
TA5110
Accelerated Weathering
ASTM D4798
2011
lad"Ov
Enmireaon
Ry(e.
Code
Entll
Mani die.
wormed,
coal
ERD(T5T 6049)
Wind Uplift
11757.08.01-1
08/13/201
ERO(TST 5049)
Tensile adhesion
1`40390.04.15
04/03/2015
END ITST E049)
Wind Uplift
11776.06.02
01/16/2003
ERD DST 6049)
TAS 103
P44360.10.14-R1
05/18/2035
ERD(1ST (apis)
Wind Uplift
P1740.01.07
01/04/2007
ERD(TST 6049)
Wind UplHt
PLYG-SC8905.05.16-1
05/17/2016
ERD ITST 6049)
ASTM D1970
P5110.04.07-1
04/11/2007
END(TST lapis)
ASTM DIWO
PLYG-SC30130.06.16-1
06/27/2016
ERD(TST 6049)
Wind Upift
P9260.03.00
03/21/2008
ERD D5t 6049)
Tensile adhesion
P1LYGSC10Baa6.16-2
06/27/2016
ERD(TST6M)
Wind Upirt
P30540.11.03-113
11/30/2W9
ERD ITST lapis)
TAS 103
PLYG-SC30130.06.16-3
W/27/2016
ERD ITST AM)
Tensile Adhesion
1,1103011.01-1
11/30/2009
ERD ITST 6049)
ASTM D1970/94798
PIYG-S00080.07.16
07/I6/2016
ERD(TST 6049)
WIM Uplift
P11030.11.09d
LUM/1009
ERD(TST Rel
Wind Unift
PLYG-SC32025.30.16
M/12/2016
ERD)T$T(A49)
ASTM M977
p130M.11.09-3
11/30/2009
ERD ITST 6049)
TAS 103
PLYG-$C33W0.12.16
12/27/2016
ERO(r5T EW9)
ASTM D1970
P33360.06.10
M/25/2010
ERD CM 6049)
W/90phye.ls
PLYG-SC119M.03.17
03/10/2017
ERD ITST E049)
TAS 103
1`33370.0111
03/02/2011
ERO(TST 6049)
TAS 103
PLY&SC12115.08.17
08/08/2017
ERD MT 6049)
Tensile Adhesion
P33370.06.11
04/26/2011
ERD ITST a049)
TAS Do
PLYG-SC33035.00.17
10/31/2017
ERD TST 6049)
ASTM D1970
P37300.30.11
10/19/2011
EM PST 3867)
Wool Uplift
3004091
01/12/2000
ERD(TST 6049)
TAS 103
P40390.08.12-1
W06/2012
ICC-ES(OWL 23%)
HICCpmpllance
ER-107
04/0l/2019
ERD(TST GM)
Tensile Adhesion
PA0390.08.12-2
09/07/2012
M-D(CER 1592)
HVH2Compllance
NOA 17-0614.22
07/06/2017
ERD(TST6(d9)
Tensile Adhesion
C41420.09.12-3
09/11/2012
MT ITST 2508)
A$TM DW98
J%20H7A
01/01/2008
ERD ITST AM)
Wind Uplift
P3%W.D3.13
03/04/2013
NEMO (TST6049)
ASTM D39M
4-0LYG-18404.03.18
03/29/20M
ERD ITST lapis)
ASTM D1970
P45370.04.13
04/26/2013
NEMO DST 6019)
Wind Uplift
4L-PLYG-184M.01.19
01/11/2019
ERDITSi(049)
Wind Uplift
P1738.02.07-R2
04/29/2013
NEMO ITST($049)
Anna D610
4S-PLYG-1&003.01.19-A
01/24/2019
ERD ITST SMI
Wind Uplift
11757.04.01-YRl
MM/2013
NEMO ITST(wen
ASTM D6M
45-PLYG-1&W2A5.14C
05/20/2019
ERD ITST 5M)
ASTM D6164
1`37590.03.13-3A
05/(6/2013
NEMO ITST aa49)
TAS 103
AS-PLYG-18-000.10.19G
10/08/2019
ERD ITST(iMU
ASTM D6509
1`37590.03.1&1-RI
(i
NEMO ITST 6049)
TAS 103
4$-PLYG-I8-004.lo.1N
10/M/2019
ERD (1ST Won
Wind Uplift
P41630.08.13
ro/(16/2013
NEMC(TST lapis)
TAS Im
45-PLYG-10-(X4.10.19-L
10/09/2019
ERD(TST 6049)
ASTM D4601
P459I0.09.13
M/04/2013
NEMO(TST6049)
TAS IM
4hPLYG-1955UDL-D1A
10/10/2019
END(TST AM)
Wind Uplift
P11751.05.03A1
106/2013
PRO UST 5878)
Tensile Adhesion
PRIDII11
G4/08/2001
ERD ITST 6049)
Wind Uplift
P11781.11.03-R1
21/26/20B
PRO 5878)
TAS Sm
PUSA-018-02-01
07/14/2003
ERD ITST adds)
30/90phys eals
P45270.05.14
05/12/2014
PRO(W 5878)
TAS 303
PUSAM5,02-01
09/29/2006
ERIDUST6049)
Tensile atlhesl0n
6020.0.14-5
03/D8/2014
Pa(TST 5878)
TAS 103
PUS4-05S02-02
12/10/2007
ERD(TST 6049)
Temile adhesion
6020.09.144
09/08/2014
PRI(TsT 5878)
ASTM D6222
PUSA-061-02-02
01/28/2008
ERD ITST 6049)
Tensile adhesion
P46s20.10.14
10/03/2014
PRI ITST 5878)
ASTM D61M
PUSA-088-02-01
07/29/2009
ERD(TST 6049)
A9TM D1970/D4798
P43290.30.14
10/17/2014
Poydass USA
P/t Affidavit
Mule -Hide Coss Ltg
03/01/2008
NEMO ETC, LUC.
Evaluation Report P12050.02.09-R25
Cert'fxme P7Aolhorvmdoo 432455
6- EDITION(2017)
FBC
NON-HVK EVALUATION
Polyglass Roof UrMedaymenh;
(954)333-1230
Revision
25: 10/14/2019
Page 2 of 16
Es�ry Enminxtlon
ERD(TST6049) TM 103
C
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
x 4.17
Referee. Date latift Euminetbn
PLVG-SQ550.03.15 03/24/2015 Polyglass UM Materials AXldaat
UL(OUM62S) Quality Control
ONEM01letc.
e.. Date
Polystick Compound M/18/2011
SeMce Confirmation 0/13/2018
PRODUCTDEScapanci
Product
Specification
Plant(s)
Description
Elastobase
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex G TU
M-D 13-004
PA
Polyester -reinforced, modified bitumen tile underlayment
FRSA/TRI April 2012
composed of a sand -surfaced SBS modified bitumen back-
side and granule -surfaced APP modified bitumen top -side
Elastoflex 56 G
ASTM 06164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI April 2012
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI April 2012
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI April 2012
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
TAS 103
waterproofing membrane, fiberglass reinforced, with a
FRSA/TRI April 2012
polyester fabric surface
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TRI April 2012
Polyflex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied "Cap Sheet" in the
'Two Ply System" from FRSA/TRI April 2012 (04-12)
beneath mechanically fastened or adhered tile roof
systems
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI April 2012
use as an alternate to Heat Applied"Cap Sheet' in the
"Two Ply System" from FRSA/TRI April 2012 (0442)
beneath mechanically fastened tile roof systems
Polyflex SA P
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI April 2012
Polyflex SA P FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/rRl April 2012
Polyglass Base
ASTM D6509
FL
Fiberglass -reinforced, APP modified bitumen base sheet
Polyglass G2 Base Sheet
ASTM D4601
AL
Fiberglass -reinforced, asphaltic base sheet
Polystick lR-Xe
ASTM D1970
FL, PA
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
Polystick MTS Plus
TAS 103
rFRS�TRI
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
April 2012
membrane, glass fiber reinforced, surfaced with
polyolefinic film surface
NEMO Efc, LLC. Evaluation Report P32060.02.09-1125
Cemfft.e.fAuPpWperlen AU2 5 8s"EDITION (2017)FBC NON-HVHZ EVALUATION FM59-R29
Polyglass Roof Underlaymporm; (954) 233-1230 Revlslon 25: 10/14/2019
Page 3 of 16
ONEMOIeti!
4. PRODUCT DESCRIPTION:
Product
Specification
Plant(s)
Description
4.18
Polystick MU-X
ASTM D1970
FL, NV, PA
Nominal 54-mi1 thick dual -layer rubberized asphalt
(See Section 5.8)
waterproofing membrane, fiberglass reinforced, with a
polypropylene film surface
4.19
Polystick TU Max
ASTMD3970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
membrane with a 190 g/m2 polyester fabric surface
FRSA/TRI April 2012
4.20
Polystick TUP
TAS 103
TX
Nominal 130-mil thick rubberized asphalt waterproofing
FRSA/TRI April 2012
membrane, glass-fiber/polyester reinforced, with a
granular surface
4.21
Polystick TU Plus
ASTM D1970
F4 PA
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, with a polyester fabric
FRSA/TRI April 2012
surface
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
Project: on which this Evaluation Report, of previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TRI 1: ROOF COyEROFrnow
Undarlayment
Asphalt5hlngle,
NaIFOn Tile
FUai The
Metal
Wood Shekel
ashingles
skit
Elastobase
Yes
Yes
Ben SMtt In 2ply Mtem l
Yes
(Base Sheet in 2-Ply anne";
Yes
Yes
Yes
ElastobaseP
Yes
yes
1. Shenihs'ly Mt,n)
Yes
(Brie..In 2-0y eaten)
Yes
Yes
Yes
Polyglass Base
No
Yes
(Bazesnertln2 PNsystml
Yes
(Base sheer In z.N' Senses)
No
No
No
Polyglass G2 Base
No
Yes
(BasesMrin2RNMwn)
Yes
(Base Meat In 2* soon)
No
No
No
Elas[o11eaGTU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elartogex 56G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex%G AR
Yes
Yes
No
No
Yes
Yes
HydriGuarE Dual Pro
Yes
No
No
Yes
Yes
Yes
Hyd2Guard Tile Pro
Yes
Yes
Yes (5ee 5.5.1)
Yes
Yes
Yes
Mule -Hide SA-APP cap
Sheat
Yes
Yes
Yes(See 5.5.1)
No
Yes
Yes
Nei M-APP Cap
She&(FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyae[G
Yes
Yes
Yes(Ses 5.5.1)
No
Yes
Yes
P lyflax G Fit
Yes
Yes
No
No
Yes
Yes
P.K. SAP
Yes
Yes
Yes Ise, 5.'.
No
Yes
Yes
PolyOex Sq PFP
=o
Yes
Yes
Yes (Le!
Na
Yes
Yes
bIIR-xe
Yes
No
No
Na
Yes
Yes
NEMO ETC, LLC. Evaluation Report P12060.0Z.09-1125
ceanNmn o)autaonaolon a32455 fi- EDITION 12017) FDC N N-HVHZ EVALUATION F1.5259-R29
Polyglass Roof UMedayments{ (954) 23}MD R.IBIon 25: 10/14/2019
Page 4 of 16
ONFruinliotr
TABLE I: ROOF COVER OPTIONS
UndadrymeM
Aaphak5hindn
Nag-0nl0e
FwmOn TIN
Metal
wood shingles
AShingW
Shte
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
Yes
Polystick MU-%
Yes
No
No
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes(See5.5.1)
Yes
No
No
Polystick TUP
No
Yes
Yes(See5.5.1)
No
No
No
Polyzlick TU Plus
Yes
Yes
Yes(See5.5.1)
Yes
Yes
Yes
5.5.2 "Foam -On Tile" is limited to use of the following Approved tile adhesives/ underlayment combinations.
TABLE 1A: AtLowmiE TBF Apifa F / UNDERIAYMENT COMBINATONES
Florida Product
Adhesive
Approval
Underlayments
DAP Foam Touch'n Seal StormBond
Roof Tile Adhesive
FL14506
Polystick TU Max or Polystick TU Plus
Dow TiIeBOnd-
FL22525
HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or
Polystick TU Plus
Elastoflex G TU, Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP
ICP Adhesives Polyset° AH-160
FL6332
Cap Sheet, Mule -Hide SA-APP Cap Sheet (FRI, Polyflex G, Polyflex SA P,
Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus
Elastoflex 56 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule-
ICP Adhesives Palyseta RTA-1
F1211
Hide SA-APP Cap Sheet (FRI, Polyflex G, Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERIAYMFNTS
Undedayment
Application
Substrates(designedto meetwind loads for pra)ect)
Type Primer Material(s)
HydraGuard Dual Pro,[adharing
Deck/
(Optional) ASTM D41
plywood, OSB, Southern Yellow Pine or Huber
HydraGuard Tile Pro,sheathing
Engineered Woods RIP System" Panels
Polystick (all variations),
ASTMD41
structural concrete
(Optional) ASTM D41
Type e, ASTM
I polylate-c
Mule -Hide SA-APP Cap
Sheet, Mule -Hide SA-APP
Insulation
orWB-3000
C1TM Type s clamslaw
C3289 Type Vpatyisocyanuratecomposite, DensDeck
mposi e, DensDe
Cap Sheet (FR), Polyflex
Prime or SECU ROCKGypsum-Fiber Roof Boartl
N/A
ASTM D226 felt, Elastobase, Elastobase P or Mule -Hide
SA P or Polyflex SA P FRBase
Sheet
Nail Base
Deck
ASTM D41
structural concrete
Elastoflex G TU, Elastoflex
hot asphalt
Insulation
(Optional) ASTM D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Sfi G or Elastoflex S6 G FR
Base
N/A
ASTM D226 felt, Elastobase, Elastobase P, Mule -Hide Nail
Sheet
Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
Polyflex G or Polyflex G FR
torch-
Insulation
(Optional) ASTM D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
Base
N/A
Elastobase, Elastobase P, Mule -Hide Nail Base, Pohglass
applied
Sheet
G2 Base or Polyglass Base
' Refer to Tile Manufacturers or Adhesive Manufactureh Florida Product Appmvol for Overturning Moment Resistance Performance.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R25
fe,tlflmh PfAuraoNxotbnpaa455 6' EDITION (2017)FBC NON-HVHZ EVALUATION Ft5259-R29
PDlydass Roof UrMerlaymentss(954)299-1230 11.161on25:10/14/2019
Page 5 of 16
ONEIIi
5.6.1 Wind Resistance for Underlayment Syste Foam -On Tile Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in FRSA/TRI April
2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is the result of testing for
wind load resistance based on allowable wind loads and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin
of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table lA or FBC 1609
for determination of design wind loads.
#1 Maximum Design Pressure =-52.5 Deli:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authariity Having
Jurisdiction.
Joints: Min. flinch wide strips of ElastoRex SA-V over all OSB joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyfle , SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#2 Maximum Design Pressure =-90 Dsf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdicion.
Primer: None
Base Pry: (Optional) Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyfle , SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure =-975 Dsf,
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PGIOO or ASTM D41
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 13t" ring shank nails
through 32 ga., 1-5/9" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-105 ad,
Deck: Min.15/32-inch plywood to meet Project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-30M
Base Ply: (Optional) Polystick MfS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x Dr ring shank nails
through 32 ga.,1-5/e diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure = .135 Deli:
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS Plus, self adhered.
Joints: Min. 4-Inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polyrtick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#6 Maximum Design Pressure =.315 Dsf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: jOptional) Polystick MTS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet IFR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered.
#7 Maximum Design Pressure =-622 5 Deli:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
MEMO ETC, U.C. Evaluation Report P12060.02.09-R25
Cemfimtea7Aurlromadb #32455 6- EDITION (2017) FEE NON.WHZ EVALUATION R5259-1129
Polyglass Roof Undedaymem4; (9501233-IM Revision 25: 10/14/2019
Page 6 of 16
ONEMOJetc.
#R Maximum Design Pressure =-300 psf-;
Deck: Min.15/32-Inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base(poly-film top surface)
Fasteners: 11 Be. x 1.25-inch long x 1-inch head diameter round metal cep nails
Spacing: &inch D.c. at the 3-inch wide side laps and 6-inch o.c.attwo (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheep Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
49 Maximum Design Pressure =-37 5 We:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 Be. x 1.25-Inch long x 1-inch head diameter round metal cap nails
Spacing: ES -inch Oc. at the 3-inch wide side laps and&inch o.c. at two(2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayri Mule -Hide SA-APP Cap Sheet, Mule -Hide 5A-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P Fit, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#10 Maximum Design Pressure=-37.5 psfa:
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 Be. x 1.25-inch long x 1-Inch head diameter round metal cap nails
Spacing: &inch o.c. at the 3-inch wide side laps and 12-inch Oc.attwo (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure =-45 psf=:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch x3/8-inch head diameter annular ring shank mofng nails at 1-5/&inch diametertincaps
Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self- adhering underiayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
#12 Maximum Design Pressure --0 Psfa:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 Be. x 1.25-inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch D.C. at the 2-inch wide side laps and flinch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underiayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP tap Sheet (Fit), Polyflex SA P, Polyflex SA P FRI, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt.
#13 Maximum Design Pressure =-45 ad:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex NAM Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure = 45.0 rest
Deck: APA rated, 7/16 CAT, DAIS in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 12 ga. annular ring shank nails with 1-5/V diameter tin caps
Spacing: &inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four(4)equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FRI, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEMO ETC, LUC. Evaluation Report P12060.02.09-RZ5
6,ngkoreaJAOh.11u,lon 1324S5 fia EDITION (2017) FSC NON-HVHZ EVALUATION FL5259-R29
Palyglass Rani Underlayments; (954) 233-1230 Revision 25:10/1412019
Page 7 of 16
®NEMOIetc.
#15 Maximum Design Pressure =-950 sf:
Deck: APA rated,7/16 CAT, 0.418 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: 12 ga. annular ring shank nails with 1-S/8" diameter tin caps
Spacing: &inch o.c. at the 3-inch wide side laps andGlnch o.c. at four (4) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
416 Maximum Design Pressure=-45.0 osf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSS sheathing to meet Project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing: &inch ox. at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Pohyflex G, torch -applied.
#17 Maximum Design Pressure =-52 5 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MARX Cap Fasteners
Spacing: 9-Inch o.c. at the 2-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment Elastoflex G TV or Elastofex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure =-52 5 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-Inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TV Plus, self -adhered.
#19 Maximum Design Pressure =-52 5 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase (sanded top surface for hat -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment Elastoflex G TV or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#20 Maximum Design Pressure =.60 f:
Deck: Min. 19/32-inch Plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase Ise rolled top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the flinch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment Elastoflex G TV or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
921 Maximum Design Pressure =.60 osf:
Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment Elastoflex G TV or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO stc, uc. Evaluation Report P32060.0209-R25
Ce,ii ..fMft6mtion#32455 6'e EDITION (2017)EBC NON-HVH2 EVALUATION 1`1_5259.1[29
Polyglass Roof Undedayments; (9M) 233.1230 Revision 25: 10/14/2019
Page 8 of 16
NNEMO[etc.
#22 Maximum Design Pressure=.600psf:
Deck: APA rated,7/16 CAT,OA38 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: &Inch o.c. at the 3-Inch wide side laps and&inch o.c. at three (3) equally spaced staggered center rows.
Primer: PGIOO or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Potyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#23 Maximum Design Press=-600Di
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, 01 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-Inch wide side laps and 8-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#24 Maximum Design Pressure =-60 0 pi
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c, at the 3-Inch wide side laps and 8-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#25 Maximum Design Pressure =-67.50sf
Deck: Min.15/32-inch plywoodto meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass 02 Base or Polyglass Base (requires use of torch -applied underayment)
Fasteners: 12 ga. x 1.2S-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#26 Maximum Design Pressure =-67.5 DO.
Deck: APA rated,19/32 CAT,0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fart Fasteners & Plates with two (2) screws per plate installed 180° Into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-Inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer (Optional) PG300 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or PolysUck TU Plus, self adhered.
#27 Maximum Design Pressure = -67.5 01
Deck: APA rated,19/32 CAT,0.578 in., Exposure 1, CST sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 1800 into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-Inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETE, Lm Evaluation Report P12060.02.09-R25
.d)rcote ofAift6ex ii#31 6"EDITION (2017) FBC Ni EVALUATION FL5259AR9
Polyglass Roof Underlaymems; (954) 233-1230 Revision 25; 10/14/2019
Page 9 of 16
MEMO I etc.
#28 Maximum Design Pressure =-675 psf:
Deck: APA rated, 19/32 CAT, 0.578in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#29 Maximum Design Pressure =-75 psf:
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underloyment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip#14 with OMG Flat
Bottom Plates (ACCUTIac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch Oc. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#30 Maximum Design Pressure=-90 psf:
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: &inch O.C. at the 2-inch wide side laps and Finch o.c. at Two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#31 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cep or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: Cinch o.c. at the 4-Inch wide side laps antl&Inch o.c. at three(3) equally spaced Staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#32 Maximum Design Pressure=-90 psf:
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast#12 OF or Trufast#14 HD with Trufast3" Metal Insulation Plates
Spacing: 6-Inch o.c. at the&mch wide side laps and&Inch o.c. at thme(3) equally spaced Staggered center news.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hat asphalt.
#33 Maximum Design Pressure=-90 psf:
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Rase (requires use of torch- applied underlayment)
Fasteners: Del fast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat
Bottom Plates (AccuTroc), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch O.C. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment. Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hat asphalt or torch -applied or Polyflex G, torch -applied.
#34 Maximum Design Press =-900 psf:
Deck: APA rated,7/16 CAT,0.418 In., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base(poly-fllm top surface)
Fasteners: TRU FAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 3inch o.c. at the 2-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TO P or Polystick TU Plus, self -adhered.
NEMO ETC, LIM EW luation R¢pVrt P12060.02.09-R25
Cen#IeoreofAudxhmnaa2455 6"EDITION (2017)FBC NON-NVHZ EVALUATION F15259-R29
Polyglass Roof UnderlaymeMa; (954) 233-1230 Revision 25:10114/2019
Page 10 of 16
®NEMOl etc.
#35 Maximum Design Pressure = -90.0 pall:
Deck: APA rated, 7/16 CAT, 0,418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#36 Maximum Design Pressure =-900 pall:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRU FAST Versa -Fart Fasteners & Plates with two (2) screws per plate installed 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-inch O.C. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment Polyflex G, torch -applied.
#37 Maximum Design Pressure =-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base(poly-flm top surface)
Fasteners: 11 ga. x 1.25-Inch x3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-Inch o.c. at the &inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#38 Maximum Design Pressure =-97.5 pall:
Deck: APA rated,19/32 CAT,0.579 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction,
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 5-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PG300 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Fit), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#39 Maximum Design Pressure =-975 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand Top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 5-inch o.c. at the 4-inch wide side laps and 6-inch ox. at four (4) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#40 Maximum Design Pressure =-97 5 asf:
Deck: APA rated, 19132 CAT, 0,578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#41 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied up or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
MEMO ETD, I.I.C. Evalaotion Report P12M.02.09-R25
[ert�fimte )Autlrodzorbn #33a55 5' EDITION(2017) RIC NON.HVHZ EVALUATION F 5 9-1129
Polyglass Roof un4edayments; (954) Z33-1230 Revision 25: 10/14/2019
Page 11 of 16
ONEMO I etc.
#42 Maximum Design Pressure =-105 0 f:
Deck: APA rated,7/16 CAT,0.418 In., Exposure 1, OSB sheathing to meet pmjeit requirementstosatisfactlon of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fart Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MIS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PDlystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#43 Maximum Design Pressure =-1050 f:
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing t0 meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheer Elastobase (,,and top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 44nch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt.
#44 Maximum Design Pressure =-105 0 pat
Deck: APA rated,7/16 CAT,0.418 in., Exposure 1, OSB sheathing t0 meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRU FAST Versa -fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#45 Maximum Design Pressure=-1125 DEC
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps
Spacing: 6-inch o.c. at the "nch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer: P61W or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS Plus, self -adhered
Underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#46 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torah -applied cap)
Fasteners: OMG #12 Standard Roofghp or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the nch wide side laps and&inch o.c. at five(5)equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#47 Maximum Design Pressu re = -120 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trofast#14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, L C. Evaluation Report P32060.02.09-US
rvIlign e=JAU .mon0n132r33 6- DMON(2011) FBC NON-HVHZ EVALUATION 1I5259-M9
Polyglass Roof UrWerlaymems; (954) 233-1330 Revision 25: 10/14/2019
Page 12 of 16
ONEMOjetc.
#48 Maximum Design Pressure =-1275 osf:
Deck: APA rated, 19/32 CAT, 0,578 in., Exposure 1, OSS sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, In the center hole.
Spacing: 9-Inch o.c. at the flinch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Primer: PGSOO or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#49 Maximum Design Pressure = -127.5 osf:
Deck: APA rated,19/32 CAT,0.578 in., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 44nch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt.
#50 Maximum Design Pressure =-1275 osf:
Deck: APA rated,19/32 CAT,0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fart Fasteners & Plates with one (1) screw Per plate, in the center hole.
Spacing: 9-inch o.c. at the flinch wide side laps and 9-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment Polyflex G, torch -applied.
5.6.1.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design
Pressure of-45 psf.
5.6.1.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that
required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure
determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a
qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss
Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the
limitations setforth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
TAlUl 3: EXPOSURE UNBTATRONs
Underlayment
Maximum Exposure (days)
Elastoflex G TU, HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick NITS Plus, Polystick TU
Polystick TU P or Polystick TU Plus
INMax,
Polystick IR-Xe or Polystick MU-X
90
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
30
180
Elastoflex% G. Elastoflex 56 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet
(for adhesive -set tile)
UNLIMITED
(FR), Polyflex G, Polyflex G FR, Pol flex 5A P or Polyflex SA P FR
(for mechanically fastened roof
prepared roof coven)
5.8 Polystick MU -%has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing
felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in
Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
NFMO ETG LLC Evaluation Report P32060.02.09-R25
Cemft'.. ofAurhorswon 132A55 6' EDITION (2017) FBC NON-HVNZ EVALUATION FLSZS9-R29
Polyglass Roof Undedayments{ (954) 233-1230 Revision 25: 10/14/2019
Page 13 of 16
5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-1211' NNEMO I etc.
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These
slope limitations can only be exceeded by using battens during loading of the roof tiles.
7ABaE2: TIM SUIPAOE LI6OTADONS FOR DIRECT-DEalnua INSTALULDONS
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10-tile stack
7:12
Waged
84ile stsck(6over2)
612
Elastoflex S6 Gor 56GFR
Fiat or Lugged
6-tile Stack (4 over 2)
4:12
HydmGuard Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polyflex G or G FIR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P Fit
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
6-tile stack is over 2)
5:12
Waged
6-tile Stock (4 over 2)
4:12
Polysdck TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Wgged
6-Ule stack (4 over 2)
7:12
Waged
10-tile stack
6:12
Polystick TUP
Flat
6-tile stack (4 over 2)
6:12
Lugged
le stack(4 over 2)
4:12
Polyxdck TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Nan -Tile Applications,
Shall be installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed and Polyglass published requirements.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FIR, Mule -
Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G PR in hot
asphalt or Polyflex G or Polyflex G PR, torch applied. Roof cover limitations are those are those associated with the top -layer
underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply
System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.1 herein, coupled with FRSA/TRI April
2012 (04-12) Installation Manual.
NEMO ETC, ULC Evaluation Report 1`32060.02.09-R25
EPTfwren)A•rthvn.son42M55 6o'EDITION (2017)FBC NON-HVH2 EVALUATION E15259-R29
Polyglass Roof Uoderiayments; (954) 233-1230 Revision 25: 10/14/2019
Page 14 of 16
6.4
6.4.1
6.4.2
6.4.3
rIF
�� NEW I etc.
HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P,
Polyflex SA P FR, Polystick IR-Xe, Polystick MTS Plus, Polystick MU-X, Polystick TU Max, Polystick TU P or Polystick TU Plus:
General:
All seal -lap seams (selvage laps) must be firmly rolled with a in
accordance with Polyglass requirements to ensure full contact
and adhesion. For HydraGuard Dual Pro and HydraGuard Tile
Pro, align the edge of the top sheet to the end of the glue
pattern (the sheet will overlap the fabric).
VIM of Ovdap Seam of HydraGuard Dual Pro and HydraGuard Tlk Pro
Non -Tile Applications,
Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBC
Table 1507.1.1 for the type of prepared roof covering to be installed and Polyglass published requirements.
Tile Applications lexcludes HvdmGuard Dual Pro, Polystick IR-Xand Polystick MU-Xh
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI April 2012 (04-12) and
Polyglass published requirements.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet
fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.1 herein.
6.4.4 Multi -Ply Underlayment Systems.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick Ni Polystick TU Max,
Polystick TU P or Polystick TU Plus is allowable for use under mechanically attached prepared roof systems. Limits of use are
those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is
desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polylex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex G TU, ElastaflexS6 G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation
requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to"Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the"Single Ply System"
from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"
In the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System"
from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet"
in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems orthe Hot Asphalt applied "Cap
Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
NEW ETC, LLC. Evaluation Report 1`32060.02.09-1125
ene$ate0fAutSonseno#32455 6'"EDITION (201)I FBc NON-HVHZ EVALUATION FL5259-129
Polyglass Roof Uoded,Mnts: (954) 233-1230 Revision 25: 10/14/2019
Page 15 of 16
ONEMOjetc.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates
noted in Table 2. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course
to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately
3/8-inch beyond the lap edge.
6.6 Polynex G or PC"" G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications:
✓ Polyflex G is for use as an altemate to the Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-
12) beneath mechanically fastened or adhered tile roof systems (Refer to Table 2 for base sheet options).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened tile roof systems (Refer to Table 2 for base sheet options).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Table 2. Side laps shall be minimum 3-inch and
end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and
inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2
herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof
slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile
sliding and/or damage to the underlayment during the loading process.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PEAMM
Contact the noted CIA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements. Refer to
Section 4 herein for product & production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTRY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
END OF EVALUATION REPORT -
NEMO ETC LLL Evaluation Report P12060.02.0 US
CertgwreofAWhohovdco Y324ss 0EDITION (2017)FRC NON-HVHZ EVALUATION FL5259-1129
Polyglass Roof Underlayments; 1954) 233-1230 Revision 25:10/14/2019
Page 16 of 16