HomeMy WebLinkAboutS202 SignedS2023/4"=1'-0"SEE ARCH7'-4" MAX.T/SLAB SEE PLAN 3"CLR.3" CLR. MONOLITHIC CONCRETE FOOTING, SEE PLAN AND SCHEDULE CONC. SLAB ON GRADE, SEE PLANFINISH GRADE, SEE CIVIL PREPARED SUBGRADE PER GEOTECHNICAL ENGINEER'S RECOMMENDATIONS 1 2 1/2" ISOLATION JOINT S2023/4"=1'-0" C.M.U. WALL, SEE PLAN AND SCHEDULE 8"X8" C.M.U. BOND BEAM W/ (1) #5 CONT., GROUT SOLID DOWELS SHALL MATCH WALL VERT. REINF. PROVIDE 62" BAR DIA LAP SPLICE, TYP.18"MIN.STANDARD ACI HOOK, TYP. T/SLAB SEE PLAN 3"CLR.3" CLR. MONOLITHIC CONCRETE FOOTING, SEE PLAN AND SCHEDULE CONC. SLAB ON GRADE, SEE PLANFINISH GRADE, SEE CIVIL PREPARED SUBGRADE PER GEOTECHNICAL ENGINEER'S RECOMMENDATIONS 1 218"MIN.STANDARD ACI HOOK, TYP.2"CLR.#5 x 30" LONG DOWELS AT 12" O.C. DRILL AND EPOXY 6" INTO CONC. THICKENED EDGE, TYP 8 S2021/2" = 1'-0" LIGHT POLE FOUNDATION3" CLR.(3) #3 ROUND TIES @ 2" O.C. AT TOP AND BOTT., AND #3 ROUND TIES AT 12" O.C. IN BETWEEN, TYP. (8) #5 VERTICALS, TYP. 1" CHAMFER, TYP.6'-3" MIN.BASE PLATE AND ANCHOR BOLTS BY LIGHT POLE MANUFACTURER NOTE: REFER TO ELECTRICAL FOR EMBEDDED CONDUIT, WIRING, ETC.3'-0"24"Ø FINISH GRADE, SEE CIVIL 1/2" ISOLATION JOINT AT SIDEWALK OR PAVEMENT, TYP. FOUNDATION BASED ON 6"X6" SQUARE LIGHT POLE W/ MAX HEIGHT OF 20'-0" AND 6 S.F. OF EPA ATTACHED. IF THESE DIMENSIONS ARE EXCEEDED, THE G.C. SHALL NOTIFY ARCH AND ENGINEER VERIFY W/ CIVIL/ARCHMF15.18MF15.18MF15.18 MF15.18 6" MIN. THICK CONCRETE SLAB ON GRADE REINF. W/ #4 AT 12" O.C. MAX., MID-DEPTH, ON PREPARED SUB-GRADE PER GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. S202 S202 S202 S202 C.J., TYP. T/SLAB=SEE ARCH SEE S101 NOTE 11 25'-4" VERIFY W/ ARCH 10'-4" VERIFY W/ ARCH 1'-4" VERIFY W/ ARCH 2'-0" VERIFY W/ ARCH 10'-4" VERIFY W/ ARCH 1'-4" VERIFY W/ ARCH 12'-8"VERIFY W/ ARCHDUMPSTER WALLS ARE TYPE MW-3 SEE SCHEDULE THIS SHEET 8 S202 DETAILSREEJBCPERMIT COMMENTS #2 08/12/20FOUNDATION NOTES: 1.) SEE S101 FOR PLAN NOTES AND SCHEDULES. 1 DUMPSTER PLAN 1/4" = 1'-0"SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDRELEASEDRAWNDATECPROJECT NO. COPYRIGHT - All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service prepared by: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.1925 Prospect Ave.Orlando, FL 32814P (407) 661-9100P (407) 661-9101Florida Corporate Certificate #AA C000526Architects Engineers Planners219026203/21/20207-ELEVEN - FORT PIERCE, FL7310 INDRIO RD FORT PIERCE, FL CREIGHTON CONST.900 SW PINE ISLAND ROAD, SUITE 202CAPE CORAL, FL 33991JUAN B. CANOPROFESSIONAL ENGINEERFLORIDA LICENSE NO. 69377HIGGENBOTHAM Engineering, Inc. Structural Engineers 9 TYPELABEL MASONRY WALL SCHEDULE VERT. REINF. AT FULL HEIGHT SECTIONS MASONRY WALL NOTES: A.) ALL MASONRY VERT. REINF. CELLS SHALL BE FILLED W/ 3000 PSI GROUT MIX, TYP. B.) PROVIDE HORIZONTAL JOINT REINF. PER STRUCTURAL NOTES ON S001. VERT. REINF. BELOW AND ABOVE OPENINGS JAMBS EA. SIDE OF OPENING ENDS AND CORNERS MW-3 8" C.M.U. PER S201N/A#5 AT 32" O.C. (CENTERED)8"X16" FULL HEIGHT PIER W/#5 AT 8" O.C. (CENTERED) 8REINFORCINGMARK FOOTING SCHEDULE SIZE 1'-6" X 18" MIN. THICK X CONT.MF15.18 (2) #5 CONT. BOTTOM 8 9 OWNER CHANGES 10/5/20