Loading...
HomeMy WebLinkAboutApproved Site Plan (Stamped Approved)VICINITY MAPLOCATION MAPCOVER SHEETC1C3C4C6C7C5UTILITY PLANGENERAL DETAILSEXISTING CONDITIONS PLANC2C8C9SITE PLANLANDSCAPE PLANDEMOLITION AND EROSION CONTROL PLANPAVING, GRADING AND DRAINAGE PLANSITEST. LUCIE BOULEVARDNORTH KINGS HIGHWAYIMMOKOLEE ROADSITEC10C11ENGINEEROWNER / APPLICANTARCHITECTSTAFFAN H. LUNDBERGARCHITECT, LLC3141 SEA HAWK LANEVERO BEACH, FL 32963PH:(772) 538-5130SECTION 25, TOWNSHIP 34S, RANGE 39EST. LUCIE COUNTY, FLORIDAJULY 2020MARKUS & ANNEMARIE PORTMANN 713 SHORE DRIVEVERO BEACH, FL 32963PH: (772) 569-0066INDIAN RIVER SPIRITSSITE IMPROVEMENTSSURVEYORC12EROSION CONTROL DETAILSGENERAL NOTES&LANDSCAPE SPECIFICATIONSLANDSCAPE DETAILSSHEETPROJECT: 20-0029DATE:A JA RONBWOL.No. 55313STATE OFROFLADlRFORPlSSEANOl N EEENGL ENSEClLAARON J. BOWLESFL. P.E. #55313ESC1NOT FOR CONSTRUCTIONPLAN SHEETS ARE PRELIMINARYAND FOR INFORMATION ONLY.PLANS SHOULD NOT BE USED ASA BASIS FOR BIDS. CONTRACTORKnow what'sbelow.before you dig.CallR72 HOURS BEFORE DIGGINGCALL TOLL FREEC:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 COVER-DETAILS.dwg 9/24/2020 1:17 PM GREGGREED INDEX OF DRAWINGS1835 20TH STREETVERO BEACH, FL 32960PH: (772) 569-0035MELBOURNE, FL - PH: (321) 253-1510FT. PIERCE, FL - PH: (772) 468-9055INDIAN RIVER SURVEY, INC.1835 20TH STREETVERO BEACH, FL 32960PH: (772) 569-7880Professional Surveying and MappingFUTURE USE UTILITY PLANC13UTILITY DETAILSLIFT STATION DETAILSC14C15C16OVERALL SITE PLANALL THAT CERTAIN TRACT OR PARCEL OF LAND LYING, BEING AND SITUATED IN SECTION25, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA AND THIS TRACTBEING MORE PARTICULARLY DESCRIBED AS FOLLOWS:COMMENCING AT THE SOUTHWEST CORNER OF SECTION 25,TOWNSHIP 34 SOUTH, RANGE39 EAST; THENCE NORTH 00°06'48" EAST, ALONG THE WEST LINE OF SAID SECTION 25; ADISTANCE OF 2655.28 FEET TO A POINT, THENCE NORTH 89°43'39" EAST, A DISTANCE OF70.98 FEET TO A POINT IN THE EAST RIGHT-OF-WAY LINE OF KINGS HIGHWAY AND THEPOINT OF BEGINNING OF THE HEREIN DESCRIBED TRACT OF LAND; THENCE NORTH00°01'15" EAST, ALONG THE EAST RIGHT-OF-WAY LINE OF SAID KINGS HIGHWAY, ADISTANCE OF 254.84 FEET TO A POINT; THENCE NORTH 89°46'12" EAST, A DISTANCE OF418.36 FEET TO A POINT, THENCE NORTH 00°01'15" EAST, A DISTANCE OF 416.79 FEET TO APOINT, THENCE NORTH 89°46'12" EAST, A DISTANCE OF 838.34 FEET TO A POINT, THENCESOUTH 00°01'16" WEST, A DISTANCE OF 670.20 FEET TO A POINT, THENCE SOUTH 89°43'39"WEST, A DISTANCE OF 1256.70 FEET TO THE POINT OF BEGINNING AND CONTAINING 15.350ACRES OF LAND MORE OR LESS.(OFFICIAL RECORD BOOK 3404 PAGE 1665)LEGAL DESCRIPTIONUTILITY DETAILSC17 C2GENERAL NOTES 9/24/2020 1.THE CONTRACTOR IS ADVISED TO THOROUGHLY REVIEW THIS PLAN PACKAGE SO AS TO BE TOTALLY PREPARED TOPRESENT HIS BID PRICES IN THE CONTRACT DOCUMENTS. THE PLAN PACKAGE SUFFICIENTLY DELINEATES THE SCOPEAND INTENT OF THE ROADWAY WORK TO BE ACCOMPLISHED. IT WILL, THEREFORE, BE INCUMBENT ON THECONTRACTOR TO ADJUST HIS FEE DOLLARS TO REFLECT ANY AND ALL ITEMS WHICH MAY NOT BE CLEARLY OUTLINEDOR THOSE ITEMS WHICH MAY NOT BE INDICATED BUT WHICH ARE NECESSARY FOR THE SUCCESSFUL COMPLETION OFTHIS PROJECT WITHOUT ADDITIONAL COSTS TO THE OWNER.2.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ST. LUCIE COUNTY AND FDOT STANDARDS AND SPECIFICATIONS.3.THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND LOCATION OF UNDERGROUND AND OTHERUTILITIES IS BASED ON AVAILABLE RECORDS AND IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THECONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATION AS TO THE TYPE AND LOCATION OFUNDERGROUND AND OTHER UTILITIES MAY BE NECESSARY TO AVOID DAMAGE THERETO AND IS RESPONSIBLE FOR THECOORDINATION OF UTILITY RELOCATION.4.CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES IN THE FIELD WITH UTILITY OWNER'S REPRESENTATIVE PRIOR TOCONSTRUCTION. UTILITY OWNERS INCLUDE, BUT ARE NOT LIMITED TO:CONSTRUCTION NOTES:ROADWAY SPECIFICATIONSGENERALIT IS INTENDED THAT THE FLORIDA DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATIONS FOR ROAD ANDBRIDGE CONSTRUCTION" MOST CURRENT EDITION BE USED WHERE APPLICABLE FOR VARIOUS WORK, AND THATWHERE SUCH WORDING THEREIN REFERS TO THE STATE OF FLORIDA AND ITS DEPARTMENT OF TRANSPORTATIONAND PERSONNEL, SUCH WORDING IS INTENDED TO BE REPLACED WITH THAT WORDING WHICH WOULD PROVIDEPROPER TERMINOLOGY, THEREBY MAKING SUCH "STANDARD SPECIFICATIONS FOR ROAD AND BRIDGECONSTRUCTION" AS THE "STANDARD SPECIFICATIONS" FOR THIS PROJECT.IF WITHIN THAT PARTICULAR SECTION ANOTHER SECTION, ARTICLE OR PARAGRAPH IS REFERRED TO, IT SHALL BE APART OF THE STANDARD SPECIFICATIONS ALSO.ALL WORK SHALL BE IN WORKMANLIKE MANNER AND SHALL CONFORM WITH ALL APPLICABLE CITY, COUNTY, STATEAND FEDERAL REGULATIONS AND/OR CODES. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR OBTAINING ALLPERMITS AND LICENSES REQUIRED TO BEGIN WORK.THE CONTRACTOR SHALL GIVE THE ENGINEER 24 HOURS NOTICE PRIOR TO REQUESTING INSPECTIONS AND SHALLSUPPLY ALL EQUIPMENT NECESSARY TO PROPERLY TEST AND INSPECT THE COMPLETED WORK.THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR A PERIOD OF TWO YEARS FROM THE DATE OFPROJECT ACCEPTANCE, DURING WHICH ALL FAULTY CONSTRUCTION AND/OR MATERIALS SHALL BE CORRECTED ATTHE CONTRACTOR'S EXPENSE.GRADINGTHE CONTRACTOR SHALL PERFORM ALL GRADING NECESSARY TO ACHIEVE THE PROPOSED PLAN GRADES INCLUDINGTYPICAL SECTIONS.ALL WORK SHALL BE IN ACCORDANCE WITH SECTION 120 OF THE STANDARD SPECIFICATIONS.STAKINGCONSTRUCTION STAKING WILL BE PERFORMED BY THE CONTRACTOR.STABILIZINGSTABILIZED SUBGRADE SHALL BE CONSTRUCTED TO THE FLORIDA BEARING VALUE AS PER PLAN FOR THE DEPTH ANDLIMITS SHOWN ON THE PLAN, AND IN ACCORDANCE WITH SECTION 160 OF THE STANDARD SPECIFICATIONS.(TYPE C STABILIZATION). ALL STABILIZED AREAS SHALL BE COMPACTED TO AT LEAST 98% OF THE MAXIMUM DENSITYAS DETERMINED BY AASHTO T-180.BASE COURSETHE BASE SHALL BE CONSTRUCTED OF EITHER LIMEROCK MATERIAL IN ACCORDANCE WITH SECTION 911 ORCEMENTED COQUINA SHELL MATERIAL IN ACCORDANCE WITH SECTION 915 OF THE STANDARD SPECIFICATIONS.LIMEROCK BASE AND CEMENTED COQUINA SHELL BASE SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 200OF THE STANDARD SPECIFICATIONS. THE CONTRACTOR SHALL PROVIDE ROCK PIT CERTIFICATION FOR CEMENTEDCOQUINA SHELL MATERIAL. BASE SHALL BE COMPACTED BY AT LEAST 98% OF THE MAXIMUM DENSITY ASDETERMINED BY AASHTO T-180. BASE SHALL BE APPROVED PRIOR TO PRIME COAT.PRIME AND TACK COATPRIME AND TACK COAT FOR THE BASE SHALL BE IN ACCORDANCE WITH SECTION 300 OF THE STANDARDSPECIFICATIONS.ASPHALTIC CONCRETE SURFACE COURSE (A.C.S.C.)TYPE SP-9.5 ACSC SHALL BE CONSTRUCTED FOR THE DEPTH AND LIMITS SHOWN ON THE PLAN, IN ACCORDANCE WITHSECTIONS 320, AND 330 OF THE STANDARD SPECIFICATIONS.TESTINGTHE CONTRACTOR SHALL RETAIN THE SERVICES OF AN APPROVED INDEPENDENT TESTING LABORATORY TOCONDUCT ALL REQUIRED TESTS ON SUBGRADE, BASE AND SURFACE COURSE MATERIALS. TEST RESULTS MUST BESUBMITTED PRIOR TO ANY REQUEST FOR PAYMENT ON THE ABOVE ITEMS.THE SCHEDULE FOR TESTING OF THE ROAD CONSTRUCTION SHALL BE AS FOLLOWS:A. SUBGRADE:1. FLORIDA BEARING VALUE TESTS SHALL BE TAKEN AT INTERVALS OF NOT MORE THAN 200 FEET, ORCLOSER AS MIGHT BE NECESSARY IN THE EVENT OF VARIATIONS IN SUBSOIL CONDITIONS.2. DENSITY TESTS SHALL BE TAKEN AT INTERVALS OF NOT MORE THAN 200 FEET OR CLOSER AS MIGHTBE NECESSARY.B. BASE:1. DENSITY TESTS SHALL BE TAKEN AT INTERVALS OF NOT MORE THAN 500 FEET OR CLOSER AS MIGHTBE NECESSARY.ALL TESTING SHALL BE TAKEN IN A STAGGERED SAMPLING PATTERN FROM A POINT 1 1/2 INCHES INSIDE THE LEFTEDGE, TO THE CENTER, TO A POINT 12 INCHES INSIDE THE RIGHT EDGE OF THE ITEM TESTED.IF ANY TEST INDICATES THAT THE WORK DOES NOT MEET THE SPECIFICATIONS, THE SUBSTANDARD AREA SHALL BEREWORKED OR CORRECTED AND RETESTED, AT THE CONTRACTOR'S EXPENSE, UNTIL THE PROVISIONS OF THESESPECIFICATIONS ARE MET.ALL PASSING TESTS SHALL BE PAID FOR BY THE OWNER. ALL FAILING TESTS SHALL BE PAID FOR BY THECONTRACTOR.CLEAN-UPTHE CONTRACTOR MUST PROVIDE CLEAN-UP OF EXCESS CONSTRUCTION MATERIAL UPON COMPLETION OF THEPROJECT. THE SITE MUST BE LEFT IN A NEAT, CLEAN, GRADED CONDITION.DRAINAGE SPECIFICATIONSSTORM INLETS AND MANHOLES SHALL BE CONSTRUCTED IN GENERAL ACCORDANCE WITH SECTION 425 OF THESTANDARD SPECIFICATIONS OF THE FLORIDA DEPARTMENT OF TRANSPORTATION.CONCRETE SHALL HAVE A MINIMUM 28-DAY STRENGTH OF 3000 PSI.ALL REINFORCING STEEL TO BE ASTM A 615-72 GRADE 40, FYP = 40,000 PSI, AND SHALL BE HANDLED AND PLACED INACCORDANCE WITH ACI 318-71.PRECAST CONCRETE MANHOLES AND STORM INLETS MAY BE USED UPON THE ENGINEER'S APPROVAL OF THEMANUFACTURER'S SHOP DRAWINGS.STORM SEWER CONSTRUCTION SHALL BE IN ACCORDANCE WITH SECTION 430 AND RELATED SECTIONS OF THESTANDARD SPECIFICATIONS OF THE FLORIDA DEPARTMENT OF TRANSPORTATION.CONCRETEUNLESS OTHERWISE SPECIFIED OR INDICATED, ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT28 DAYS OF 3000 PSI. ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF THE AMERICAN CONCRETEINSTITUTE (ACI) BUILDING CODE AND THE APPLICABLE BUILDING CODES HAVING JURISDICTION IN THE AREA.CULVERT PIPESREINFORCED CONCRETE PIPE (R.C.P.) SHALL BE IN ACCORDANCE WITH SECTION 449 OF THE STANDARDSPECIFICATIONS.PRECAST CONCRETE DRAINAGE PRODUCTSALL PRECAST CONCRETE DRAINAGE PRODUCTS (INCLUDING BUT NOT LIMITED TO ROUND CONC. PIPE. ELLIPTICALCONC. PIPE, UNDERDRAINS, MANHOLES, INLETS, ENDWALLS, JUNCTION BOXES, THREE SIDED CONC. CULVERTS, ANDCONC. BOX CULVERTS) SHALL BE IN ACCORDANCE WITH SECTION 449 OF THE STANDARD SPECIFICATIONS.GROUNDWATERGROUNDWATER MAY BE ENCOUNTERED ON SITE. CONTRACTOR TO PLAN ACCORDINGLY.RECORD DRAWINGSCONTRACTOR SHALL KEEP AND MAINTAIN RECORD DRAWINGS ON THE PROJECT SITE AT ALL TIMES WHICH SHALL BEANNOTATED BY THE CONTRACTOR DEPICTING ANY CHANGES MADE IN THE FIELD WHICH DIFFER FROM THECONTRACT DRAWINGS. RECORD DRAWINGS SHALL INCLUDE, BUT NOT LIMITED TO, INVERT AND TOP ELEVATIONS OFCULVERTS AND INLET STRUCTURES. CONTRACTOR SHALL SUBMIT COMPLETE AND FINAL RECORD DRAWINGS TOENGINEER UPON COMPLETION OF PROJECT AND PRIOR TO FINAL INSPECTION AND FINAL PAYMENT.DRAINAGE SPECIFICATIONS (CONTINUED)INSPECTIONMINIMUM CONSTRUCTION INSPECTION CHECKPOINTSTHE ENGINEER SHALL BE NOTIFIED:1. PRIOR TO ANY MAJOR DEVIATION FROM THE APPROVED PLANS.2. PRIOR TO BACKFILLING ANY PIPE TRENCHES.3. UPON COMPLETION OF SUBGRADE GRADING AND COMPACTION.4. UPON BEGINNING OF SPREADING OF ROCK BASE MATERIAL.5. UPON COMPLETION OF GRADING AND COMPACTION OF THE BASE MATERIAL AND PRIOR TO PRIMING.6. IMMEDIATELY PRIOR TO AND UPON APPLICATION OF A.C.S.C.7. UPON COMPLETION OF CONSTRUCTION.CONSTRUCTION IN STREETS AND ROAD RIGHT-OF-WAYS1. OPEN ROAD CUTS REQUIRES PRIOR APPROVAL OF THE CITY, COUNTY, STATE OR ANY OTHER AGENCY WHICHMAY HAVE JURISDICTION.2. ALL CONSTRUCTION, MATERIALS AND WORKMANSHIP ARE TO BE IN ACCORDANCE WITH FLORIDADEPARTMENT OF TRANSPORTATION SPECIFICATIONS AND STANDARDS.3. ALL AREAS IN EXISTING RIGHT-OF-WAYS DISTURBED BY CONSTRUCTION SHALL RECEIVE SOLID SOD.4. STREET RESTORATION TO BE DONE AS PER ST. LUCIE COUNTY STANDARDS.5. THE CONTRACTOR SHALL COMPLY WITH ALL RULES AND REGULATIONS OF THE STATE, COUNTY AND CITYAUTHORITIES REGARDING CLOSING OR RESTRICTING THE USE OF PUBLIC STREETS OR HIGHWAYS.6. TRAFFIC CONTROL ON ALL COUNTY AND STATE HIGHWAY RIGHT-OF-WAYS SHALL MEET THE REQUIREMENTSOF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (U.S. DOT/FHA) AND THE REQUIREMENTS OF THESTATE AND ANY LOCAL AGENCY HAVING JURISDICTION.GENERAL NOTES:1. CONTRACTOR IS RESPONSIBLE FOR CHECKING ACTUAL SITE CONDITIONS BEFORE STARTING CONSTRUCTION.2. ANY DISCREPANCIES ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORECOMMENCING WORK.3. CONTRACTOR SHALL OBTAIN COPIES OF ALL REQUIRED PERMITS BEFORE COMMENCING WORK. CONTRACTORSHALL FAMILIARIZE HIMSELF OF ALL PERMIT CONDITIONS AND PERFORM ALL WORK AN ACCORDANCE WITHALL SAID CONDITIONS.4. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALLCONTACT ALL CONCERNED UTILITIES AT LEAST 48 HOURS IN ADVANCE FOR CONSTRUCTION OPERATIONS.5. NO FIELD CHANGES OR DEVIATIONS FROM DESIGN TO BE MADE WITHOUT PRIOR APPROVAL OF THE ENGINEER.6. ALL CONSTRUCTION SHALL BE COMPLETED IN ACCORDANCE WITH THE APPLICABLE ST. LUCIE COUNTYORDINANCES.7. CONTRACTOR SHALL SUPPLY DENSITY TESTS TO ENGINEER ON ALL SUB-GRADE AND BASE. TESTS SHALL BEPREPARED PER AASHTO T-180 METHOD.8. SLOPE GRADES FROM ELEVATIONS SHOWN TO EXISTING GRADE AT PROPERTY LINE. MAXIMUM SLOPE 3:1.9. ENGINEER SHALL BE NOTIFIED AT LEAST 48 HOURS IN ADVANCE FOR ANY INSPECTION.10. ALL TRAFFIC CONTROL DEVICES SHALL BE IN ACCORDANCE WITH M.U.T.C.D. STANDARDS.11. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION"STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION", DATED 2019.12. THE PRESENCE OF GROUNDWATER SHOULD BE ANTICIPATED ON THIS PROJECT. CONTRACTORS BID SHALLINCLUDE CONSIDERATION FOR ADDRESSING THIS ISSUE.13. ALL INLETS SHALL HAVE A 6" MIN. SUMP BELOW LOWEST INVERT.14. EROSION CONTROL FENCING MUST BE IN PLACE PRIOR TO GRADING.15. PIPE LENGTHS AND SLOPES SHOWN ARE APPROXIMATE.16. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION IT SHALL BE THECONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TORETURN IT TO EXISTING CONDITIONS OR BETTER.17. ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE ISWATERTIGHT.18. CONTRACTOR SHALL ADJUST INLET/STRUCTURE OR CONNECTION LOCATION AS REQUIRED TO ENSUREPROPOSED STRUCTURES AND PIPES ARE IN PROPER ALIGNMENT AND MATCH SLOPE OF EXISTING PIPES ORCONNECTIONS.19. THIS PLAN CONTEMPLATES ACCESS CONNECTIONS TO ADJACENT ROADS AS SHOWN.20. FILL MATERIAL MAY NOT BE STOCKPILED HIGHER THAN SIX (6) VERTICAL FEET ONSITE PER ST. LUCIE COUNTYCODE.21. DIMENSIONS SHOWN ARE TO EDGE OF GUTTER OR PAVEMENT. RADII SHOWN ARE TO FACE OF CURB.22. ALL SIGNS SHALL BE MUTCD STANDARD.23. ALL PAVEMENT MARKINGS, EXCEPT PARKING STALL STRIPING, SHALL BE THERMOPLASTIC PER ST. LUCIECOUNTY REQUIREMENTS.24. THE USES PROPOSED AS PART OF THIS PLAN DO NOT REQUIRE A SUBMITTAL OF A RISK MANAGEMENT PLANPURSUANT TO U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) REGULATIONS AND SHALL NOT EXCEED THEEPA'S RMP THRESHOLD QUANTITIES OF LISTED SUBSTANCES.25. WATER FOR FIRE FIGHTING PURPOSES SHALL BE INDICATED WITH A BLUE ROADWAY REFLECTOR, PLACE ONEFOOT OFF OF THE CENTERLINE OF THE ROAD FACING THE FIRE HYDRANT. THIS INCLUDES NEW AND EXISTINGSOURCES.26. REGARDLESS OF PRIVATE OR PUBLIC DEDICATIONS, THERE SHALL BE NO UTILITY CONNECTIONS, METERBOXES OR VALVE BOXES IN EXISTING OR PROPOSED SIDEWALK OR DRIVEWAY AREAS.27. CONTRACTOR SHALL ADJUST INLET/STRUCTURE OR CONNECTION LOCATION AS REQUIRED TO ENSUREPROPOSED STRUCTURES AND PIPES ARE IN PROPER ALIGNMENT AND MATCH SLOPE OF EXISTING PIPES ORCONNECTIONS.28. ANY STATE AND FEDERAL PERMITS THAT MAY BE REQUIRED AS A RESULT OF LAND CLEARING ANDLANDSCAPING ACTIVITIES ARE THE RESPONSIBILITY OF THE CONTRACTOR.29. CONTRACTOR IS RESPONSIBLE TO PROTECT AND/OR REPLACE ALL SURVEY MONUMENTATION BY A LICENSEDSURVEYOR IN THE STATE OF FLORIDA.AT&T(888) 944-0447FLORIDA POWER & LIGHT3301 ORANGE AVENUEFORT PIERCE, FL 34947(800) 343-7941COMCAST CABLE(800) 288-8849ST. LUCIE COUNTY2300 VIRGINIA AVENUEFT. PIERCE, FLORIDA(772) 432-11505. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY ALL UTILITY COMPANIES A MINIMUM OF TWO WORKING DAYSPRIOR TO EXCAVATION, AS REQUIRED BY THE UNDERGROUND FACILITY DAMAGE PREVENTION AND SAFETY ACT. NOTIFYSUNSHINE AT 811.6. UTILITIES ARE TO BE ADJUSTED BY UTILITY OWNER OR AS DIRECTED BY THE ENGINEER.7. SURFACE INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FOR USE IN ESTABLISHING DESIGN CRITERIA FORTHE PROJECT. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED AND IS NOT TO BE CONSTRUED AS PART OFTHE PLANS GOVERNING CONSTRUCTION OF THE PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INQUIREOF THE ENGINEER IF ADDITIONAL INFORMATION IS AVAILABLE, TO MAKE ARRANGEMENTS TO REVIEW SAME PRIOR TOBIDDING, AND IS TO MAKE HIS OWN DETERMINATION AS TO ALL SUBSURFACE CONDITIONS.8. CONTRACTOR SHALL NOTIFY THE ENGINEER IF SOIL OR SUBSURFACE CONDITIONS UNSUITABLE FOR CONSTRUCTIONARE ENCOUNTERED.9. ALL EXCAVATED SOILS DEEMED SUITABLE AS FILL MATERIAL AS DETERMINED BY THE ENGINEER SHALL BE UTILIZED ONSITE BY THE CONTRACTOR AT HIS OWN EXPENSE. THE EXACT LOCATION OF DELIVERY ON SITE SHALL BE DETERMINEDBY THE ENGINEER. ALL EXCAVATED SOILS DEEMED UNSUITABLE SHALL BE DISPOSED OF BY THE CONTRACTOR AT HISOWN EXPENSE.10. ITEM IN CONFLICT WITH DESIGN SUCH AS EXISTING CURBS AND GUTTERS, SIDEWALKS, DRAINAGE STRUCTURES,PAVEMENT AND EXCESS EXCAVATIONS ARE TO BE REMOVED BY THE CONTRACTOR AND DISPOSED OF IN A LEGAL ANDPROPER MANNER AWAY FROM THE JOB SITE AT HIS OWN EXPENSE.11. IT SHOULD BE NOTED THAT THE OCCUPATIONAL SAFETY AND HEALTH ACT PROHIBITS THE OPERATING OF EQUIPMENTOR MACHINES CLOSER THAN TEN (10) FEET TO ENERGIZED ELECTRIC LINES RATES AT FIFTY KILOVOLTS OR BELOW.ALSO, NO EXCAVATION IS PERMITTED WITHIN FIVE (5) FEET OF POWER POLE FACILITIES.12. ALL IRONS AND MONUMENTS (P.R.M.'S) SHOWN ON PLANS, OR FOUND, SHALL BE PRESERVED. THOSE SHOWN INPROPOSED PAVEMENT SHALL BE PROTECTED WITH A CAST IRON VALVE BOX.13. ANY PUBLIC LAND CORNERS WITHIN THE LIMITS OF CONSTRUCTION ARE TO BE PROTECTED. IF A CORNER MONUMENT ISIN DANGER OF BEING DESTROYED OR DISTURBED, THE CONTRACTOR WILL NOTIFY THE ENGINEER.14. ALL EXISTING TREES WITHIN THE RIGHT OF WAY ARE TO BE REMOVED AS CLEARING AND GRUBBING UNLESS OTHERWISENOTED.15. WHEN REFERENCED TO, FDOT REFERS TO FLORIDA DEPARTMENT OF TRANSPORTATION ROADWAY AND TRAFFIC DESIGNSTANDARDS,CURRENT EDITION.16. THE CONTRACTOR SHALL RESTORE ALL AREAS DISTURBED BY CONSTRUCTION TO A CONDITION EQUAL TO, OR BETTERTHAN, THAT NOW EXISTING.17. BACKFILL, GRADE AND SOD AS REQUIRED AROUND ALL NEW CONSTRUCTION AND ALL DEVELOPED LOTS TO PREVENTEROSION. SEED AND MULCH WILL ONLY BE ALLOWED TO RESTORE UNDEVELOPED LOTS AFFECTED BY CONSTRUCTIONOR AS DIRECTED BY THE ENGINEER.18. SODDING TO BE USED AT LOCATIONS AS DIRECTED BY THE ENGINEER.19. PROPERTY OWNERS AND BUSINESSES WITHIN THE AREA OF CONSTRUCTION SHALL BE GIVEN ACCESS TO THEIRPROPERTY AT ALL TIMES DURING THE PERIOD OF CONSTRUCTION.20. ALL MAILBOXES SHALL BE RELOCATED BY THE CONTRACTOR AS DIRECTED BY THE U.S. POSTAL MAIL CARRIER.21. THE CONTRACTOR SHALL REMOVE, COVER OR OBLITERATE EXISTING ROADWAY SIGN AND PAVEMENT MARKINGS THATCONFLICT WITH THE CONSTRUCTION TRAFFIC CONTROL PLANS.22. CONTRACTOR TO PROTECT ALL SPRINKLER HEADS NOT IN CONFLICT WITH DESIGN AND RELOCATE ALL THOSE WHICHARE IN CONFLICT TO A LOCATION DETERMINED IN FIELD.23. SOD TWO (2) FEET MINIMUM ALONG SIDE PROPOSED EDGE OF PAVEMENT.24. THE CONTRACTOR IS REQUIRED TO PERFORM HIS WORK IN ACCORDANCE WITH THE REQUIREMENTS OF THE VARIOUSPERMITS WHICH WILL BE OBTAINED PRIOR TO BEGINNING CONSTRUCTION.25. THE CONTRACTOR SHALL PROVIDE ANY TEMPORARY DRAINAGE MEASURES AS REQUIRED TO ADEQUATELY DRAIN THEPROJECT AND ANY TEMPORARILY TRAVELED ROADWAYS. TEMPORARY DRAINAGE DESIGN, CONSTRUCTION ANDMAINTENANCE IS THE CONTRACTOR'S RESPONSIBILITY; HOWEVER, ALL SUCH MEASURES MUST BE APPROVED BY THEENGINEER.26. THE EXISTING SIDEWALK SHALL NOT BE DISTURBED UNLESS OTHERWISE NOTED.27. GRADES SHOWN ARE FINISHED GRADES.28. SAWCUT CONCRETE OR ASPHALT DRIVEWAYS AS REQUIRED FOR REPLACEMENT.29. ALL ABANDONED UTILITIES (INCLUDING PIPES, CABLES AND STRUCTURES) FOUND IN THE RIGHT OF WAYAND NOT SHOWN ON THE PLANS, ARE TO BE REMOVED AND PROPERLY DISPOSED OF AT THE EXPENSE OFTHE CONTRACTOR. THIS INCLUDES ALL EXOTIC PIPES LIKE ASBESTOS-CEMENT PIPE. COST TO BE INCLUDEDIN CLEARING AND GRUBBING ITEM.30. DRIVEWAY LOCATIONS AND WIDTHS ARE APPROXIMATE AND ARE TO BE ADJUSTED AS NECESSARY OR ASDIRECTED BY THE ENGINEER.31. BENCHMARK DATUM IN N.A.V.D. 1988.32. BACKFILL AND SOD AS REQUIRED BEYOND RIGHT OF WAY LINES ON INDIVIDUAL LOTS TO MAINTAINPOSITIVE DRAINAGE FLOW INTO CURB AND GUTTER.33. GRADE AND SOD SWALES TEN (10) FEET FROM PROPOSED DITCH BOTTOM INLETS AND MITERED ENDSECTIONS ON SIDE STREETS AS REQUIRED.34.IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN(BASELINE) AND ℄ (CENTERLINE) CONSTRUCTIONTHROUGHOUT THE PROJECT.35. THE CONTRACTOR SHALL SUBMIT A CONSTRUCTION SCHEDULE (SEQUENCE OF OPERATIONS) PRIOR TOTHE PRE-CONSTRUCTION MEETING.36. THE CONTRACTOR SHALL REMOVE DRIVEWAY APRONS AND DRIVEWAY CULVERTS AND SHALL MAINTAINROUGH GRADE FOR UTILITY MODIFICATIONS.37. ALL EXISTING SWALES SHALL BE PROTECTED BY THE CONTRACTOR. ANY DAMAGE TO THE SWALE LINESHALL BE CORRECTED BY THE CONTRACTOR AT HIS OWN EXPENSE.38. PAYMENT FOR INCIDENTAL ITEMS NOT SPECIFICALLY COVERED IN THE INDIVIDUAL BID ITEMS SHALL BEINCLUDED IN THE CONTRACT PRICES FOR BID ITEMS.39. MAINTAIN A MINIMUM OF ONE (1) FOOT CLEARANCE BETWEEN POWER POLE AND EDGE OF SIDEWALK.40. WHEN ALL OTHER PERMANENT CONSTRUCTION IS COMPLETE, THE FINAL SURFACE COURSE SHALL BEPLACED.41. CONSTRUCTION OPERATIONS FOR PLACEMENT OF THE FINAL SURFACE COURSE SHALL BE LIMITED TO ADISTANCE, AS DIRECTED BY THE ENGINEER, THE CONTRACTOR CAN COMPLETE IN ONE (1) DAY.42. THE CONTRACTOR SHALL IMPLEMENT TEMPORARY PAVEMENT MARKINGS UNTIL THE FINAL SURFACECOURSE HAS CURED (MINIMUM THIRTY (30) DAYS AFTER FINAL SURFACE COURSE PLACEMENT). ANYTEMPORARY PAINTED MARKINGS PLACED ON THE FINAL.43. PAVEMENT TRANSITION SHALL BE MADE IN ACCORDANCE WITH PAVEMENT TRANSITION DETAIL. FLORIDA REVISIONS DATE 1835 - 20TH STREET VERO BEACH, FL 32960 PH. (772) 569-0035 FX. (772) 778-3617 MELBOURNE, FL - PH (321) 253-1510 FT. PIERCE, FL - PH (772) 468-9055 A JA RONBWOL.No. 55313STATE OFROFLADlRFORPlSSEANOl N EEENGL ENSEClLAARON J. BOWLESFL. P.E. #55313ESC:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 COVER-DETAILS.dwg 9/24/2020 1:18 PM GREGGREED ST. LUCIE COUNTY INDIAN RIVER SPIRITS SITE IMPROVEMENTS FDEP SEPARATION CRITERIA:(1)HORIZONTAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS, WASTEWATER ORSTORM WATER FORCE MAINS, RECLAIMED WATER PIPELINES, AND ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS.(A) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEASTTHREE FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED STORM SEWER,STORM WATER, FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER62-610,F.A.C.(B)NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEASTTHREE FEET, AND PREFERABLY TEN FEET, BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING ORPROPOSED VACUUM-TYPE SANITARY SEWER.(C) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST SIXFEET, AND PREFERABLY TEN FEET, BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING ORPROPOSED GRAVITY OR PREASSURE-TYPE SANITARY SEWER, WASTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMEDWATER NOT REGULATED UNDER PART III OF CHAPTER 62-610,F.A.C. THE MINIMUM HORIZONTAL SEPARATION DISTANCEBETWEEN WATER MAINS AND GRAVITY TYPE SANITARY SEWERS SHALL BE REDUCED TO THREE FEET WHERE THE BOTTOM OFTHE WATER MAIN IS LAID AT LEAST SIX INCHES ABOVE THE TOP OF THE SEWER.(D) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST TENFEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND ALL PARTS OF ANY EXISTING OR PROPOSED "ON-SITE SEWAGETREATMENT AND DISPOSAL SYSTEM" AS DEFINED IN SECTION 381.0065(2),F.S., AND RULE 64E-6.002, F.A.C.(2)VERTICAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR STORMWATER FORCE MAINS, AND RECLAIMED WATER PIPELINES.(A) NEW OR RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED GRAVITY OR VACUUME-TYPESANITARY SEWER OR STORM SEWER SHALL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST SIX INCHES, ANDPREFERABLY 12 INCHES, ABOVE OR AT LEAST 12 INCHES BELOW THE OUTSIDE OF THE OTHER PIPELINE. HOWEVER, IT ISPREFERABLE TO LAY THE WATER MAIN ABOVE THE OTHER PIPELINE.(B) NEW OR RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED PRESSURE-TYPE SANITARYSEWER, WASTEWATER OR STORM WATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER SHALL BE LAID SO THEOUTSIDE OF THE WATER MAIN IS AT LEAST 12 INCHES ABOVE OR BELOW THE OUTSIDE OF THE OTHER PIPELINE. HOWEVER, IT ISPREFERABLE TO LAY THE WATER MAIN ABOVE THE OTHER PIPELINE.(C) AT THE UTILITY CROSSINGS DESCRIBED IN PARAGRAPHS (A) AND (B) ABOVE, ONE FULL LENGTH OF WATER MAIN PIPE SHALLBE CENTERED ABOVE OR BELOW THE OTHER PIPELINE SO THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THEOTHER PIPELINE. ALTERNATIVELY, AT SUCH CROSSINGS, THE PIPES SHALL BE ARRANGED SO THAT ALL THE WATER MAINJOINTS ARE AT LEAST THREE FEET FROM ALL JOINTS IN VACUUM-TYPE SANITARY SEWERS, STORM SEWERS, STORM WATERFORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C., AND ATLEAST SIX FEET FROM ALL JOINTS IN GRAVITY OR PRESSURE-TYPE SANITARY SEWERS, WASTEWATER FORCE MAINS, ORPIPELINES CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.(3)SEPARATION BETWEEN WATER MAINS AND SANITARY OR STORM SEWER MANHOLES(A) NO WATER MAIN SHALL PASS THROUGH, OR COME INTO CONTACT WITH, ANY PART OF A SANITARY SEWER MANHOLE.(B)EFFECTIVE AUGUST 28, 2003, WATER MAINS SHALL NOT BE CONSTRUCTED OR ALTERED TO PASS THROUGH, OR COME INTOCONTACT WITH, ANY PART OF A STORM SEWER MANHOLE OR INLET STRUCTURE.(4)SEPARATION BETWEEN FIRE HYDRANT DRAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR STORM WATER FORCEMAINS, RECLAIMED WATER PIPELINES, AND ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS.NEW OR RELOCATED FIRE HYDRANTS WITH UNDERGROUND DRAINS SHALL BE LOCATED SO THAT THE DRAINS ARE AT LEAST THREE FEET FROM ANY EXISTING OR PROPOSED STORM SEWER, STORM WATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C; AT LEAST THREE FEET, AND PREFERABLY TEN FEET,FROM ANY EXISTING OR PROPOSED VACUUM-TYPE SANITARY SEWER; AT LEAST SIX FEET, AND PREFERABLY TEN FEET, FROMANY EXISTING OR PROPOSED GRAVITY-OR PRESSURE-TYPE SANITARY SEWER, WASTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.; AND AT LEAST TEN FEET FROM ANY EXISTING OR PROPOSED "ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM" AS DEFINED IN SECTION 381.0065(2), F.S.,AND RULE 64E-6.002, F.A.C. KINGS HIGHWAYEXISTING IMPERVIOUS STABILIZED AREA (20,778 SF) EXISTING IMPERVIOUS STABILIZED AREA (4,804 SF) EXISTING WET POND FLORIDAREVISIONSDATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055AJARON B WOL. No. 55313 STATE OF ROFL ADl RF O R P lSSE ANO lNEEE N GL ENSEClL AARON J. BOWLES FL. P.E. #55313 ES C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C3 EX CONDITIONS PLAN.dwg 9/24/2020 1:16 PMGREGG REEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTSC3EXISTING CONDITIONS PLAN9/24/2020Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 EXISTING CONDITIONS PLAN SCALE: 1" = 30' SURVEY LEGEND EXISTING ASPHALT EXISTING CONCRETE LEGEND EXISTING DITCH AREA OF EXISTING COARSE AGGREGATE ROCK (6" THICK) KINGS HIGHWAYO O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O OOO OOO O OOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO REMOVE EX. STORM PIPE & MITERED END SECTIONS X X X X X INSTALL SILT FENCE, TYP. INSTALL SILT FENCE, TYP. INSTALL INLET PROTECTION FENCING REMOVE EXISTING COCONUT PALM EXISTING ASPALT PARKING TO BE REMOVED, TYP.XXXXXXXXXXXXXXXXXXXREMOVE EX. FENCE EX. OAKS TO BE REMOVED EX. OAK TO BE RELOCATED EX. DRY POND TO BE MODIFIED EX. DRY POND TO BE MODIFIED EXISTING SIGN TO BE RELOCATED TO BE WITHIN DOT RIGHT-OF-WAY EX. OAK TO BE REMOVED INSTALL INLET PROTECTION FENCING O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O EXISTING WET POND O O O O O O O O O O O O O OOOOO OOOOOOOOOOOOOOOOOOOOOOOO INSTALL SILT FENCE, TYP.FLORIDAREVISIONSDATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055AJARON B WOL. No. 55313 STATE OF ROFL ADl RF O R P lSSE ANO lNEEE N GL ENSEClL AARON J. BOWLES FL. P.E. #55313 ES C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C4 DEMO-EROSION PLAN.dwg 9/24/2020 1:16 PMGREGG REEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTSC4DEMOLITION ANDEROSION CONTROL PLAN9/24/20201 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 DEMOLITION AND EROSION CONTROL PLAN SCALE: 1" = 30' EXISTING ASPHALT EXISTING CONCRETE PROPOSED CONCRETE LEGEND PROPOSED ASPHALT Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE MATCH LINE A-AMATCH LINE A-A1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 DEMOLITION AND EROSION CONTROL PLAN SCALE: 1" = 30' O O PROPOSED SILT FENCE EXISTING DITCH AREA OF EXISTING COARSE AGGREGATE ROCK (6" THICK) AREA OF EXISTING ASPHALT TO BE REMOVED OO OO PROPOSED INLET PROTECTION FENCING DEMOLITION NOTES: 1. SEE LANSCAPE PLAN PACKAGE RE: TREE PROTECTION REQUIREMENTS, MITIGATION, AND EXTENTS OF SPECIES REMOVAL. 2. ALL EXOTIC AND INVASIVE SPECIES ARE TO BE REMOVED. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR THE ATTAINMENT OF ALL DEMOLITION / LAND CLEARING PERMITS NECESSARY FOR PROPOSED CONSTRUCTION. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY / ALL EROSION CONTROL MEASURE AS PRESENTED ON THIS SHEET AND INCLUDED IN THE STORMWATER POLLUTION PREVENTION PLAN (SWPPP). 5. ANY EXISTING ON-WELLS LOCATED SHALL BE IDENTIFIED TO THE ENGINEER OF RECORD FOR THE ACKNOWLEDGEDMENT OF APPLICABLE USE OR PROPER ABANDONMENT. C5EROSION CONTROL DETAILS 9/24/2020N.T.S.SOIL TRACKING PREVENTION DEVICE DETAILCONSTRUCTION ACTIVITIES CAN RESULT IN THE GENERATION OF SIGNIFICANT AMOUNTS OF POLLUTANTS WHICH MAYREACH SURFACE OR GROUND WATERS. ONE OF THE PRIMARY POLLUTANTS OF SURFACE WATERS IS SEDIMENT DUETO EROSION. EXCESSIVE QUANTITIES OF SEDIMENT WHICH REACH WATER BODIES OF FLOOD PLAINS HAVE BEENSHOWN TO ADVERSELY AFFECT THEIR PHYSICAL, BIOLOGICAL AND CHEMICAL PROPERTIES. TRANSPORTED SEDIMENTCAN OBSTRUCT STREAM CHANNELS, REDUCE HYDRAULIC CAPACITY OF WATER BODIES OF FLOOD PLAINS, REDUCETHE DESIGN CAPACITY OF CULVERTS AND OTHER WORKS, AND ELIMINATE BENTHIC INVERTEBRATES AND FISHSPAWNING SUBSTRATES BY SILTATION. EXCESSIVE SUSPENDED SEDIMENTS REDUCE LIGHT PENETRATION ANDTHEREFORE, REDUCE PRIMARY PRODUCTIVITY.1. SEDIMENT BASIN AND TRAPS, PERIMETER DIKES, SEDIMENTBARRIERS AND OTHER MEASURES INTENDED TO TRAPSEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANYLAND-DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONALBEFORE UNSLOPE LAND DISTURBANCE TAKES PLACE.2. ALL SEDIMENT CONTROL MEASURES ARE TO BE ADJUSTED TOMEET FIELD CONDITIONS AT THE TIME OF CONSTRUCTION ANDBE CONSTRUCTED PRIOR TO ANY GRADING OR DISTURBANCEOF EXISTING SURFACE MATERIAL ON BALANCE OF SITE.PERIMETER SEDIMENT BARRIERS SHALL BE CONSTRUCTED TOPREVENT SEDIMENT OR TRASH FROM FLOWING OR FLOATINGON TO ADJACENT PROPERTIES.3. PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BEAPPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTERFINAL GRADE IS REACHED ON ANY PORTION OF THE SITE.TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHINSEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINALGRADE BUT WILL REMAIN UNDISTURBED FOR LONGER THAN 30DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TOAREAS THAT ARE TO BE LEFT UNDISTURBED FOR MORE THANONE YEAR.4. DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILESSHALL BE STABILIZED OR PROTECTED WITH SEDIMENTTRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FORTHE TEMPORARY PROTECTION AND PERMANENTSTABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL ASSOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE.5. A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ONDENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED.PERMANENT VEGETATION SHALL NOT BE CONSIDEREDESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT, INTHE OPINION OF THE REVIEWER, IS UNIFORM, MATUREENOUGH TO SURVIVE AND WILL INHIBIT EROSION.6.STABILIZATION MEASURES SHALL BE APPLIED TO EARTHENSTRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONSIMMEDIATELY AFTER INSTALLATION.7. SURFACE RUNOFF FROM DISTURBED AREAS THAT ISCOMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THANOR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY ASEDIMENT BASIN. THE SEDIMENT BASIN SHALL BE DESIGNEDAND CONSTRUCTED TO ACCOMMODATE THE ANTICIPATEDSEDIMENT LOADING FROM THE LAND-DISTURBING ACTIVITY.THE OUTFALL DEVICE OR SYSTEM DESIGN SHALL TAKE INTOACCOUNT THE TOTAL DRAINAGE AREA FLOWING THROUGH THEDISTURBED AREA TO BE SERVED BY THE BASIN.8. AFTER ANY SIGNIFICANT RAINFALL, SEDIMENT CONTROLSTRUCTURES WILL BE INSPECTED FOR INTEGRITY. ANYDAMAGED DEVICES SHALL BE CORRECTED IMMEDIATELY.9. CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILLSLOPES UNLESS CONTAINED WITHIN AN ADEQUATETEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPEDRAIN STRUCTURE.10. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATEDRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED.11. SEDIMENT WILL BE PREVENTED FROM ENTERING ANY STORMDRAIN SYSTEM, DITCH OR CHANNEL. ALL STORM SEWER INLETSTHAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BEPROTECTED SO THAT SEDIMENT-LADEN WATER CANNOTENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEINGFILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT.12. BEFORE TEMPORARY OR NEWLY CONSTRUCTED STORMWATERCONVEYANCE CHANNELS ARE MADE OPERATIONAL, ADEQUATEOUTLET PROTECTION AND ANY REQUIRED TEMPORARY ORPERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTHTHE CONVEYANCE CHANNEL AND RECEIVING CHANNEL.13.WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED,PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT,CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREATO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION.NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTIONOF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USEDFOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVERMATERIALS.14.WHEN A LIVE WATERCOURSE MUST BE CROSSED BYCONSTRUCTION VEHICLES, A TEMPORARY STREAM CROSSINGCONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED.15.THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZEDIMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED.16.PERIODIC INSPECTION AND MAINTENANCE OF ALL SEDIMENTCONTROL STRUCTURES MUST BE PROVIDED TO ENSURE INTENDEDPURPOSE IS ACCOMPLISHED. THE DEVELOPER, OWNER AND/ORCONTRACTOR SHALL BE CONTINUALLY RESPONSIBLE FOR ALLSEDIMENT LEAVING THE PROPERTY. SEDIMENT CONTROLMEASURES SHALL BE IN WORKING CONDITION AT THE END OFEACH WORKING DAY.17.UNDERGROUND UTILITY LINES SHALL BE INSTALLED INACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TOOTHER APPLICABLE CRITERIA:A. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BEOPENED AT ONE TIME.B. EXCAVATED MATERIAL SHALL BE PLACED ON THEUPHILL SIDE OF TRENCHES.C. EFFLUENT FROM DEWATERING OPERATIONS SHALL BEFILTERED OR PASSED THROUGH AN APPROVEDSEDIMENT TRAPPING DEVICE, OR BOTH, ANDDISCHARGED IN A MANNER THAT DOES NOTADVERSELY AFFECT FLOWING STREAMS OR OFF-SITEPROPERTY.D. RESTABILIZATION SHALL BE ACCOMPLISHED INACCORDANCE WITH THESE REGULATIONS.18. WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECTPAVED PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZETHE TRANSPORT OF SEDIMENT BY TRACKING ONTO THE PAVEDSURFACE, WHERE SEDIMENT IS TRANSPORTED ONTO A PUBLICROAD SURFACE WITH CURBS AND GUTTERS, THE ROAD SHALL BECLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENTSHALL BE REMOVED FROM THE ROADS BY SHOVELING ORSWEEPING AND TRANSPORTED TO A SEDIMENT CONTROLDISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLYAFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISIONSHALL APPLY TO INDIVIDUAL SUBDIVISION LOTS AS WELL AS TOLARGER LAND-DISTURBING ACTIVITIES.19. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURESSHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITESTABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NOLONGER NEEDED, IN THE OPINION OF THE REVIEWER. DISTURBEDSOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARYMEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENTFURTHER EROSION AND SEDIMENTATION.20. PROPERTIES AND WATERWAYS DOWNSTREAM FROMCONSTRUCTION SITE SHALL BE PROTECTED FROM SEDIMENTDISPOSITION AND EROSION.21. PHASED PROJECTS SHOULD BE CLEARED IN CONJUNCTION WITHCONSTRUCTION OF EACH PHASE.22. EROSION CONTROL DESIGN AND CONSTRUCTION SHALL FOLLOWTHE REQUIREMENTS IN INDEX NOS. 104 AND 105 OF FDOTROADWAY AND TRAFFIC DESIGN STANDARDS.23. THE REVIEWER MAY APPROVE MODIFICATIONS OR ALTER PLANSTO THESE EROSION CONTROL CRITERIA DUE TO SITE SPECIFICCONDITIONS.MINIMUM STANDARDS EROSION AND SEDIMENTATION CONTROL NOTES1.5 SEC. -1200 GAL./MIN./S.F.20 US SIEVE90%45 LBS.420 P.S.I.135 LBS.20%265 LBS.ASTM D-4491ASTM D-4491ASTM D-4751ASTM D-4355ASTM D-4533ASTM D-3786ASTM D-4833ASTM D-4632ASTM D-4632PERMITTIVITYFLOW RATEAPPARENT OPENING SIZEUV RESISTANCETRAPEZOID TEARMULLEN BURSTPUNCTUREGRAB TENSILE ELONGATIONGRAB TENSILE STRENGTHUNITSTEST METHODPROPERTIESMODERATE TO HIGH FLOW GEOTEXTILE FABRIC SPECIFICATION TABLE0.55 SEC. -140 GAL./MIN./S.F.40 US SIEVE80%120 LBS.800 P.S.I.120 LBS.20%300 LBS.ASTM D-4491ASTM D-4491ASTM D-4751ASTM D-4355ASTM D-4533ASTM D-3786ASTM D-4833ASTM D-4632ASTM D-4632PERMITTIVITYFLOW RATEAPPARENT OPENING SIZEUV RESISTANCETRAPEZOID TEARMULLEN BURSTPUNCTUREGRAB TENSILE ELONGATIONGRAB TENSILE STRENGTHUNITSTEST METHODPROPERTIESLOW TO MODERATE FLOW GEOTEXTILE FABRIC SPECIFICATION TABLEAANOTE:FOR STOCKPILING ERODIBLE MATERIAL FOR EXTENDED PERIODS, THE AREA SHALL BE SEEDED AND MULCHED.NOTE:ALL STOCKPILES SHALL BE A MAXIMUM OF 25' HIGH.SILT FENCE AND/OR HAY BALES (TYP.)19' MAX.STOCKPILE OFERODIBLE MATERIALSECTION A-ATURBIDITY BARRIER APPLICATIONSN.T.S.10' MAXIMUM SPACING WITH WIRESUPPORT FENCE, 6' MAXIMUMSPACING WITHOUT WIRE SUPPORTFENCEEXTRA STRENGTH FILTERFABRIC NEEDED WITHOUT WIREMESH SUPPORTNOTES:1. SILT FENCE SHALL BE PLACEDON SLOPE CONTOURS TOMAXIMIZE PONDINGEFFICIENCY.2. INSPECT AND REPAIR FENCEAFTER EACH STORM EVENTAND REMOVE SEDIMENT WHENNECESSARY. 9" MAXIMUMRECOMMENDED STORAGEHEIGHT.3. REMOVED SEDIMENT SHALL BEDEPOSITED TO AN AREA THATWILL NOT CONTRIBUTESEDIMENT OFF-SITE AND CANBE PERMANENTLY STABILIZED.ATTACH FILTER FABRICSECURELY TO UPSTREAM SIDEOF POSTFLOWSTEEL OR WOOD POST-36" HIGH MAX.3'MIN.FLOW4"X6" TRENCH WITHCOMPACTED BACKFILLPONDING HEIGHT3'MIN.FLOW34" MIN. DRAIN ROCK9" MAX.STORAGEHEIGHT8"PONDING HEIGHTSTEEL ORWOOD POSTTRENCH DETAILINSTALLATION WITHOUTTRENCHINGPRINCIPLE POSTPOSITION (CANTED 20°TOWARD FLOW)FILTER FABRICNOTE: SPACING FOR TYPE III FENCETO BE IN ACCORDANCE WITH CHART I,SHEET 1 OF 3 AND DITCHINSTALLATIONS AT DRAINAGESTRUCTURES SHEET 2 OF 3SECTIONELEVATION7'MAX.SILT FLOW20°+-OPTIONAL POSTPOSITIONSVERTICALFILTER FABRIC (INCONFORMANCE WITHSEC. 985 F.D.O.T.SPEC.)8"15"-18"1' MIN.4' MIN.POST OPTIONS:WOOD 2-1/2" MIN. DIA.WOOD 2"X4"OAK 1-1/2"X1-1/2"STEEL 1.33 LBS./FT. MIN.NOTES: SILT FENCE TO BE PAID FOR UNDER THE CONTRACT UNIT PRICE FOR STAKED SILT FENCE (L.F.)TYPE III SILT FENCESILT FENCE APPLICATIONSTYPE III SILT FENCEPROTECTION AROUND DITCHBOTTOM INLETSDO NOT DEPLOY IN A MANNER THAT SILT FENCES WILL ACT AS A DAM ACROSS PERMANENT FLOWING WATERCOURSES. SILT FENCES ARETO BE USED AT UPLAND LOCATIONS AND TURBIDITY BARRIERS USED AT PERMANENT BODIES OF WATER.SILTFLOWTYPE IV SILT FENCESILT FENCE INLET PROTECTION2"X2" STAKEFABRICFABRICEXTENDS1'MIN.GATHEREXCESSAT CORNERSDROP INLETWITH GRATEFRAMECROSS BRACE2"X4" WOOD FRAME2"X4" WOOD FRAME5'15"MIN.18"MAX.5' MIN.(TYP.)VIEW OF FRAME WITHOUTSILT FENCEVIEW OF FRAME WITHSILT FENCESEDIMENT CONTROL DETAIL FORSTOCKPILING OF ERODIBLEMATERIALN.T.S.N.T.S.N.T.S.N.T.S. SOCK-PIPE OR ROCK BAGINLET FILTERN.T.S.N.T.S. POLY WATTLES ORGEOHAY CURB INLETFILTERLIMITS OF CLEARINGORANGE SAFETY FENCESILT FENCE6" MAX6" MAXWORK AREA6" MAXUPLAND BUFFER/CE LINESILT FENCESILT FENCE/ORANGE FENCE PLACEMENTDETAIL AROUND WETLANDSN.T.S.CONSERVATION EASEMENTNo Clearing or LandDisturbance Beyond This Sign!DO NOT REMOVE THIS SIGN4'-0"26" MIN.12"NOTE:1. SIGN MATERIAL SHALL BE PLASTIC OR METAL, ATTACHED TO4"x4" TREATED WOOD POST.2. CONSERVATION EASEMENT SHALL BE 3" HIGH LETTERS.3. ALL OTHER LINES OF TEXT SHALL BE 1" HIGH WITH 1" SPACINGBETWEEN LINES.4. SIGN SHALL HAVE WHITE BACKGROUND WITH CONTRASTINGCOLOR FOR THE LETTERING.CONSERVATION EASEMENT SIGNN.T.S.ROCK BAGROCK BAGPOLY WATTLEOR GEO HAYROCK BAGSN.T.S.INLET INSERT SEDIMENT CONTAINMENT SYSTEMDITCH INSTALLATIONSCL Median DitchSilt BarrierSilt BarrierSilt BarrierLimits Of ConstructionSod10' (Typ. )50' Max.SodCross Drain50' Max.50' Max.Endwall50' Max.Ditch50' Max.Limits Of ConstructionDitch Bottom Inlet50' Max.SodAT DRAINAGE STRUCTURES10 milPLASTICLININGSECTION A-AAANOTES:1. ACTUAL LAYOUT DETERMINED IN THE FIELD.2. THE CONCRETE WASHOUT SIGN SHALL BEINSTALLED WITHIN 30' OF THE TEMPORARYCONCRETE WASHOUT FACILITY.PLYWOOD, 4'X2'PAINTED WHITEBLACK LETTERS6" HEIGHTLAG SCREWS(12" DIA.)WOOD POSTS(4"X4"X9')CONCRETEWASHOUTCONCRETE WASHOUT SIGNDETAIL (OR EQUIVALENT)CONCRETE & STUCCOWASTE MANAGEMENTPLANTYPE "ABOVE GRADE"N.T.S.SILTFENCESILTFENCE(TYP.)10 mil.PLASTICLINING10 mil.PLASTICLININGFLORIDA REVISIONS DATE 1835 - 20TH STREET VERO BEACH, FL 32960 PH. (772) 569-0035 FX. (772) 778-3617 MELBOURNE, FL - PH (321) 253-1510 FT. PIERCE, FL - PH (772) 468-9055 A JA RONBWOL.No. 55313STATE OFROFLADlRFORPlSSEANOl N EEENGL ENSEClLAARON J. BOWLESFL. P.E. #55313ESC:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 COVER-DETAILS.dwg 9/24/2020 1:19 PM GREGGREED ST. LUCIE COUNTY INDIAN RIVER SPIRITS SITE IMPROVEMENTS 125' 125'80'80'125' 125'80'80'PROPOSED BUILDING 1 CITRUCELLO PLANT 10,000 S.F. PROPOSED BUILDING 2 (FUTURE PHASE) ASSEMBLY PLANT 10,000 S.F.5' CONC. SIDEWALK5' CONC. SIDEWALK5' CONC. SIDEWALK 15' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER KINGS HIGHWAY~~ ~~ SC MH: 20 SA MH: 20 SB MH: 18 SA MH: 20 EXISTING WET POND 16 18 17 19.65 19 19.65 19 18 17 16 19.65 19 18 17 16 SB MH: 18 EXISTING IMPERVIOUS STABILIZED AREA (20,778 SF) EXISTING IMPERVIOUS STABILIZED AREA (4,804 SF) LIMITS OF DEVELOPMENT LIMITS OF DEVELOPMENT LIMITS OF DEVELOPMENT FLORIDAREVISIONSDATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055AJARON B WOL. No. 55313 STATE OF ROFL ADl RF O R P lSSE ANO lNEEE N GL ENSEClL AARON J. BOWLES FL. P.E. #55313 ES C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C6 OVERALL SITE PLAN.dwg 9/24/2020 1:15 PMGREGG REEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTSC6OVERALL SITE PLAN9/24/2020Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 50 100 50 OVERALL SITE PLAN SCALE: 1" = 50' EXISTING ASPHALT EXISTING CONCRETE PROPOSED CONCRETE LEGEND PROPOSED ASPHALT EXISTING DITCH PROPOSED LIGHT POLE (BY OTHERS) AREA OF EXISTING COARSE AGGREGATE ROCK (6" THICK) PROPOSED HEAVY DUTY CONCRETE 15' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER KINGS HIGHWAY& 10' SIDE SETBACK LINE (IL ZONING) 25'FRONT BUILDING SETBACK LINE PER IL ZONING & 10' SIDE SETBACK LINE (IL ZONING) 125' 125'80'80'125' 125'80'80'PROPOSED BUILDING 1 CITRUCELLO PLANT 10,000 S.F. F.F.E.= 21.50 PROPOSED BUILDING 2 (FUTURE PHASE) DISTRIBUTION CENTER 10,000 S.F. F.F.E.= 21.50 5' CONC. SIDEWALK 5' CONC. SIDEWALK TRUCK RADIUS R45' TRUCK RADIUS R45' TRUCK ROUTE TRUCK ROUTE TRUCK ROUTE RELOCATED 8' WIDE METAL & STUCCO PROJECT SIGN SC MH: 20 SA MH: 20 SB MH: 18 SA MH: 20 16 18 17 19.65 19 19.65 19 18 17 16 19.65 19 18 17 16 25' R / W DEDICATION SB MH: 18 PROPOSED DRY DETENTION AREA PROPOSED DRY DETENTION AREA 10'712.42'419.46' 420.56' 711.34'5'26'18'5'5'26' 4 4 101110 7 4 7.5' DIA. WALL SIGN (BY OTHERS) EXISTING IMPERVIOUS STABILIZED AREA (4,804 SF) EXISTING IMPERVIOUS STABILIZED AREA (20,778 SF) PROPOSED LIGHT POLE, TYP. (BY OTHERS)5' CONC. SIDEWALK5' CONC. SIDEWALKFTP-20-06 HC PARKING SIGN, SEE DETAIL SHEET C9 12" FTP-20-06 HC PARKING SIGN, SEE DETAIL SHEET C11 WHEEL STOP, TYP. WHEEL STOP, TYP.438.54'15' X 30' LOADING ZONE 15' X 30' LOADING ZONE BIKE RACK (BY OTHERS) EXISTING DUMPSTER LOCATION, PROVIDE NEW CHAIN LINK FENCE ENCLOSURE W/ SCREENING EXISTING 12'X30' LOADING ZONE 18'18'10'26'3 55' PROPOSED LIGHTING, TYP. (SEE ARCHITECTURAL PLANS FOR DETAILS) R5' R5'52'(3) 12" TYPE 4 OBJECT MARKERS (OM4-1) 6' O.C. TYPE "F" CURB, TYP. TYPE "D" CURB, TYP. TYPE "D" CURB, TYP. TYPE "D" CURB, TYP. TYPE "D" CURB, TYP. TYPE "F" CURB, TYP. INSTALL 3' CURB TRANSITION 14.33'12'12'14.33'10'21.8'R35' R35' R3' R3' R5' R5' R3' R3' R3'FLORIDAREVISIONSDATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055AJARON B WOL. No. 55313 STATE OF ROFL ADl RF O R P lSSE ANO lNEEE N GL ENSEClL AARON J. BOWLES FL. P.E. #55313 ES C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C7 SITE PLAN.dwg 9/24/2020 1:15 PM GREGGREEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTSC7SITE PLAN9/24/2020Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 SITE PLAN SCALE: 1" = 30' PERMITS REQUIRED FLOOD ZONE SITE ADDRESS TAX PARCEL I.D. NUMBER(S) OWNER/APPLICANT PROJECT INFORMATION ZONING LAND USE ENGINEER LEGAL DESCRIPTION ALL THAT CERTAIN TRACT OR PARCEL OF LAND LYING, BEING AND SITUATED IN SECTION 25, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA AND THIS TRACT BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHWEST CORNER OF SECTION 25,TOWNSHIP 34 SOUTH, RANGE 39 EAST; THENCE NORTH 00°06'48" EAST, ALONG THE WEST LINE OF SAID SECTION 25; A DISTANCE OF 2655.28 FEET TO A POINT, THENCE NORTH 89°43'39" EAST, A DISTANCE OF 70.98 FEET TO A POINT IN THE EAST RIGHT-OF-WAY LINE OF KINGS HIGHWAY AND THE POINT OF BEGINNING OF THE HEREIN DESCRIBED TRACT OF LAND; THENCE NORTH 00°01'15" EAST, ALONG THE EAST RIGHT-OF-WAY LINE OF SAID KINGS HIGHWAY, A DISTANCE OF 254.84 FEET TO A POINT; THENCE NORTH 89°46'12" EAST, A DISTANCE OF 418.36 FEET TO A POINT, THENCE NORTH 00°01'15" EAST, A DISTANCE OF 416.79 FEET TO A POINT, THENCE NORTH 89°46'12" EAST, A DISTANCE OF 838.34 FEET TO A POINT, THENCE SOUTH 00°01'16" WEST, A DISTANCE OF 670.20 FEET TO A POINT, THENCE SOUTH 89°43'39" WEST, A DISTANCE OF 1256.70 FEET TO THE POINT OF BEGINNING AND CONTAINING 15.350 ACRES OF LAND MORE OR LESS. (OFFICIAL RECORD BOOK 3404 PAGE 1665) SURVEYOR ST. LUCIE COUNTY MAJOR AMENDMENT TO A MINOR SITE PLAN ST. LUCIE COUNTY VEGETATION REMOVAL PERMIT ST. LUCIE COUNTY STORMWATER PERMIT ST. LUCIE COUNTY FIRE DEPT. REVIEW ST. LUCIE COUNTY RIGHT-OF-WAY ST. LUCIE COUNTY UTILITIES FPUA CONSTRUCTION REVIEW SFWMD PERMIT FDEP WATER DISTRIBUTION PERMIT FDEP WASTEWATER COLLECTION PERMIT FDEP NPDES NOTICE OF INTENT DOH SEPTIC ABANDONMENT (BY CONTRACTOR) PARKING DATA DRAINAGE STATEMENT 3200 N. KINGS HIGHWAY FORT PIERCE, FLORIDA 34951 MARKUS & ANNEMARIE PORTMANN 713 SHORE DRIVE VERO BEACH, FLORIDA 32960 PHONE (772) 569-0066 MBV ENGINEERING, INC. 1835 20TH STREET VERO BEACH, FLORIDA 32960 PHONE (772) 569-0035 INDIAN RIVER SURVEY, INC. 1835 20TH STREET VERO BEACH, FLORIDA 32960 PHONE (772) 569-7880 1325-233-0000-000-7 IL MXD PROJECT DESCRIPTION THE PROPOSED PROJECT CONSISTS OF ADDING TWO (2) PRE-FABRICATED STRUCTURES EACH 10,000 SQ. FEET. THE FIRST BUILDING WILL HAVE AN OFFICE FOR INDIAN RIVER SPIRITS MAIN PRODUCT, CITRUCELLO. THE SECOND BUILDING WILL BE UTILIZED AS STORAGE OF FINISHED PRODUCTS. ARCHITECT STAFFAN H. LUNDBERG ARCHITECT, LLC 1341 SEA HAWK LANE VERO BEACH, FLORIDA Z32963 PHONE (772) 538-5130 LATITUDELONGITUDE 27°29'31" N 80°23'47" W ST. LUCIE COUNTY NOTES 1. PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY ALL CATEGORY I LISTED INVASIVE SPECIES SHALL BE ERADICATED FROM THE SITE. 2. THE ISSUANCE OF COUNTY DEVELOPMENT PERMIT DOES NOT IN ANY WAY CREATE ANY RIGHTS ON THE PART OF THE APPLICANT TO OBTAIN A PERMIT FROM A STATE OR FEDERAL AGENCY AND DOES NOT CREATE ANY LIABILITY ON THE PART OF THE COUNTY IF THE APPLICANT FAILS TO OBTAIN REQUISITE APPROVALS OR FULFILL THE OBLIGATIONS IMPOSED BY A STATE OR FEDERAL AGENCY OR UNDERTAKES ACTIONS THAT RESULT IN A VIOLATION OF STATE OR FEDERAL LAW. 3. ALL OTHER APPLICABLE STATE OR FEDERAL PERMITS MUST BE OBTAINED BEFORE COMMENCEMENT OF THE DEVELOPMENT. WASTEWATER SOURCE POTABLE WATER SOURCE ST. LUCIE COUNTY UTILITIES FORT PIERCE UTILITIES AUTHORITY (FUTURE) (PER 5TH EDITION ITE PARKING GENERATION) REQUIRED EXISTING USES GENERAL LIGHT INDUSTRIAL (110) (10,522 SF) 0.65 SPACES / 1000 SF OF GFA = 7 SPACES GENERAL OFFICE (710) (2,600 SF) 1.84 SPACES/ 1000 SF OF GFA = 5 SPACES TOTAL EXISTING SPACES REQUIRED = 12 SPACES PROPOSED USES GENERAL LIGHT INDUSTRIAL (110) BLDG 1 (10,000 SF) 0.65 SPACES / 1000 SF OF GFA = 7 SPACES BLDG 2 (10,000 SF) 0.65 SPACES / 1000 SF OF GFA = 7 SPACES TOTAL PROPOSED SPACES REQUIRED = 14 SPACES TOTAL REQUIRED SPACES (EXISTING + PROPOSED)= 26 SPACES TOTAL REQUIRED HANDICAPPED SPACES (EXISTING + PROPOSED) = 2 SPACES PROPOSED EXISTING PARKING = 45 SPACES (41 STANDARD, 3 PARALLEL, 1 HANDICAPPED) PROPOSED PARKING = 8 SPACES (4 STANDARD, 2 HANDICAPPED) TOTAL PROPOSED PARKING (EXISTING + PROPOSED) = 53 SPACES (45 STANDARD 3 PARALLEL, 3 HANDICAPPED) EXISTING ASPHALT EXISTING CONCRETE PROPOSED CONCRETE LEGEND PROPOSED ASPHALT 50' MAX.BUILDING HEIGHT: -OPEN SPACE: 20'REAR YARD SETBACK: SIDE YARD SETBACK: 25'FRONT YARD SETBACK: 100'LOT WIDTH: 20,000 SF LOT SIZE: BUILDING COVERAGE: REQUIRED (IL)PROPOSED 50% 3.65% 668,864 SF 254.84' 711.34' 420.56' 88.60% 24'-8" 10'10' PREVIOUSLY APPROVED EXPANSION SITE DATA TOTAL OPEN AREA = 592,490 SF = 88.60 %= 13.60 Ac EXISTING SITE DATA SITE AREA = 668,864 SF = 100.00 %= 15.35 Ac TOTAL IMPERVIOUS AREA TOTAL OPEN AREA = 77,596 SF = 591,268 SF = 88.40 % = 11.60 %= 1.78 Ac = 13.57 Ac EXISTING COVERED CONCRETE AREA EXISTING BUILDING AREA EXISTING PAVEMENT AREA = 1,506 SF = 14,276 SF = 36,083 SF = 0.20 % = 5.41 % = 2.15 % = 0.03 Ac = 0.83 Ac = 0.33 Ac EXISTING CONCRETE AREA = 149 SF = 0.02 %= 0.00 Ac SITE AREA = 668,864 SF = 100.00 %= 15.35 Ac EXISTING COVERED CONCRETE AREA EXISTING BUILDING AREA EXISTING PAVEMENT AREA = 1,506 SF = 14,276 SF = 36,083 SF = 0.20 % = 5.41 % = 2.15 % = 0.03 Ac = 0.83 Ac = 0.33 Ac EXISTING CONCRETE AREA = 149 SF = 0.02 %= 0.00 Ac PROPOSED BUILDING AREA PROPOSED PAVEMENT AREA = 10,000 SF = 2,563 SF = 0.40 % = 1.50 % = 0.06 Ac = 0.23 Ac PROPOSED CONCRETE AREA = 687 SF = 0.07 %= 0.01 Ac EXISTING 6" AGGREGATE ROCK AREA = 25,582 SF = 3.84 %= 0.59 Ac EXISTING 6" AGGREGATE ROCK AREA = 25,582 SF = 3.84 %= 0.59 Ac LIMITS OF DEVELOPMENT AREA = 86,560 SF = 12.96 %= 1.99 Ac TOTAL IMPERVIOUS AREA = 76,374 SF = 11.40 %= 1.75 Ac LESS 6" AGGREGATE TO BE REMOVED*=(-)14,472 SF =(-)0.33 Ac EXISTING 6" AGGREGATE TO REMAIN = 11,110 SF = 1.69 %= 0.26 Ac NET NEW IMPERVIOUS AREA = (-)1,222 SF =(-)0.03 Ac 50' MAX.BUILDING HEIGHT: -OPEN SPACE: 20'REAR YARD SETBACK: SIDE YARD SETBACK: 25'FRONT YARD SETBACK: 100'LOT WIDTH: 20,000 SF LOT SIZE: BUILDING COVERAGE: REQUIRED (IL)PROPOSED 50% 5.12% 668,864 SF 254.84' 711.34' 419.46' 82.26% 24'-8" 10'10' PROPOSED NEW CONSTRUCTION SITE DATA TOTAL OPEN AREA = 550,202 SF = 82.26 %= 12.63 Ac SITE AREA = 668,864 SF = 100.00 %= 15.35 Ac EXISTING COVERED CONCRETE AREA EXISTING BUILDING AREA EXISTING PAVEMENT AREA = 1,506 SF = 14,276 SF = 36,083 SF = 0.23 % = 5.39 % = 2.13 % = 0.03 Ac = 0.83 Ac = 0.33 Ac EXISTING CONCRETE AREA = 149 SF = 0.02 %= 0.00 Ac PROPOSED BUILDING AREA PROPOSED PAVEMENT AREA = 20,000 SF = 18,310 SF = 2.74 % = 2.99 % = 0.42 Ac = 0.46 Ac PROPOSED CONCRETE AREA = 2,756 SF = 0.41 %= 0.06 Ac EXISTING 6" AGGREGATE ROCK AREA = 25,582 SF = 3.82 %= 0.59 Ac LIMITS OF DEVELOPMENT AREA = 233,333 SF = 5.36 Ac TOTAL IMPERVIOUS AREA = 118,662 SF = 17.74 %= 2.72 Ac NET NEW IMPERVIOUS AREA = 41,066 SF = 0.94 Ac THE SUBJECT PROPERTY IS LOCATED IN FLOOD ZONE 'X' PER FLOOD INSURANCE RATE MAP #12111C0160 J, DATED FEB. 16, 2012. THE PROPOSED STORM WATER MANAGEMENT SYSTEM SERVES TO EXPAND THE EXISTING DRY DETENTION POND SYSTEM, CURRENTLY SERVING THE DEVELOPED SITE, TO ACCOUNT FOR THE PROPOSED SITE IMPROVEMENTS = 34.88 % ST. LUCIE COUNTY UTILITIES FORT PIERCE UTILITIES AUTHORITY (FUTURE) EXISTING DITCH PROPOSED LIGHT POLE (BY OTHERS) AREA OF EXISTING COARSE AGGREGATE ROCK (6" THICK) 438.54' TRAFFIC STATEMENT CONSTRUCTION SCHEDULE BEGIN CONSTRUCTION NOVEMBER 2020 END CONSTRUCTION APRIL 2021 PER ITE, 10TH EDITION USE: WAREHOUSING BUILDING AREA USED = 10,000 SF 10,000 SF/ 1,000 SF BLDG = 10 X 1.74 TRIPS = 17.4 TRIPS = 18 TRIPS 9 ENTERING AND 9 EXITING USE: WAREHOUSING BUILDING AREA USED = 10,000 SF 10,000 SF/ 1,000 SF BLDG = 10 X 1.74 TRIPS = 17.4 TRIPS = 18 TRIPS 9 ENTERING AND 9 EXITING TOTAL TRIPS = 36 TOTAL ENTERING = 18 TOTAL EXITING = 18 PROPOSED HEAVY DUTY CONCRETE KINGS HIGHWAY& 10' SIDE SETBACK LINE (IL ZONING) 25'FRONT BUILDING SETBACK LINE PER IL ZONING & 10' SIDE SETBACK LINE (IL ZONING) 125' 125'80'80'125' 125'80'80'PROPOSED BUILDING 1 CITRUCELLO PLANT 10,000 S.F. F.F.E.= 21.50 PROPOSED BUILDING 2 (FUTURE PHASE) DISTRIBUTION CENTER 10,000 S.F. F.F.E.= 21.50 5' CONC. SIDEWALK 5' CONC. SIDEWALK RELOCATED 8' WIDE METAL & STUCCO PROJECT SIGN SC MH: 20 SA MH: 20 SB MH: 18 SA MH: 20 16 18 17 19.65 19 19.65 19 18 17 16 19.65 19 18 17 16 25' R / W DEDICATION SB MH: 18 PROPOSED DRY DETENTION AREA PROPOSED DRY DETENTION AREA 20.00± M.E. 19.98± M.E. 19.80 19.80 20.60 20.10 20.60 20.10 20.73 20.96 20.36 20.96 20.36 20.20 20.91 20.41 21.45 21.35 20.85 21.17 20.67 21.45 21.17 20.67 20.49 21.45 21.50 21.50 21.40 21.40 21.50 21 LF 18" ADS N-12 M.E.S. INV.= 16.00 21.45 21.17 20.67 20.66 20.16 19.91 CONC. FLUME CONC. FLUME DRAINAGE BASIN BOUNDARY DRAINAGE BASIN BOUNDARY DRAINAGE BASIN BOUNDARY DRAINAGE BASIN BOUNDARY M.E.S. INV.= 16.00 A A 21.14 21.40 21.40 20.94 21.35 20.8521.35 20.85 21.35 20.85 21.35 20.85 21.35 20.85 21.35 20.8521.35 20.85 21.35 20.85 21.35 20.85 20.91 20.41 21.17 20.67 21.17 20.67 21.17 20.67 21.17 20.67 21.17 20.67 21.17 20.67 21.17 20.67 NOTE: ROOF DISCHARGE FROM BOTH BUILDINGS TO BE CONVEYED TO STORMWATER TREATMENT SYSTEM CONTRACTOR TO GRADE DOWN 4:1 MAX SLOPE TO EXISTING (TYP.) CONTRACTOR TO GRADE DOWN 4:1 MAX SLOPE TO EXISTING (TYP.) C C BB21.15 21.15 20.85 20.85 20.85 20.85 20.07 19.57 20.07 19.57 25 LF 18" ADS N-12 21 LF 18" ADS N-12 DS-1 FDOT 425-024 CURB INLET RIM EL.= 19.57 S. INV.= 16.00 N. INV.= 16.00 DS-2 FDOT 425-024 CURB INLET RIM EL.= 19.57 S. INV.= 16.00 N. INV.= 16.00 INSTALL 3' CURB TRANSITION 20.46 20.72 21.30 20.80 21.30 20.80 21.30 20.80 21.30 20.80 21.30 20.80 21.30 20.80 DDEESECTION A-A N.T.S. EXISTING GROUND 19.3 19.919.6 16.00 19.65 20.70 20.20 F.F.E.= 21.50 21.40 20.90 21.45 BUILDING 5' CONC. WALK44' PAVEMENT8'14.6' DRY DETENTION AREA 110'± 4:1 TYPE "F" CURB 16.00 19.65 4:1 F.F.E.= 20.32 19.8 5'EX. BUILDING 14.6' EXISTING GROUND 16.00 19.65 4:1 14.6' 16.00 19.65 4:1 14.6' 20.70 20.20 TYPE "F" CURB 20.70 20.20 TYPE "F" CURB MITERED END SECTION 18" ADS N-12 7'2'13' 2% 20.46 19.65 4:1 14.6' MITERED END SECTION 18" ADS N-12 7'2'13' 2%19.65 4:1 16.00 16.00 14.6'11.5'20.3' LP DRAINAGE BASIN BOUNDARY 2' 4:1 MAX.MATCH EX. 18.6± EX. SWALE 4:1 MATCH EX. 18.5± EXISTING GROUND DRY DETENTION AREA 107± 18" ADS N-12 26' ASPHALT PAVEMENT DS-1 DS-2 DRY DETENTION AREA 41'± 2' 12.9' 19.0 16.0 16.0 18.6 18.5 16.0 16.4 SECTION B-B N.T.S. F.F.E.= 21.50 BUILDING DRAINAGE BASIN BOUNDARY 21.5' 18.1 20.5 4:1 MAX.MATCH EX. 18.3± SECTION C-C N.T.S. 21.0 5' LP MATCH EX. 18.5± EXISTING GROUND 4:1 8" WM SECTION D-D N.T.S. 1.8' 8.2' 10'0.67'ASPHALT PAVEMENT LP MATCH EX. 18.5± F.F.E.= 21.50 BUILDING 4:1 MAX. 21.0 EXISTING GROUND 8" WM SECTION E-E N.T.S. 10'FLORIDAREVISIONSDATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055AJARON B WOL. No. 55313 STATE OF ROFL ADl RF O R P lSSE ANO lNEEE N GL ENSEClL AARON J. BOWLES FL. P.E. #55313 ES C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C8 PGD PLAN.dwg 9/24/2020 1:14 PM GREGGREEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTSC8PAVING, GRADING ANDDRAINAGE PLAN9/24/2020Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 PAVING, GRADING AND DRAINAGE PLAN SCALE: 1" = 30' EXISTING ASPHALT EXISTING CONCRETE PROPOSED CONCRETE LEGEND PROPOSED ASPHALT 20.00 PROPOSED GRADE 20.00± M.E. PROPOSED GRADE MATCH EXISTING MITERED END SECTIONM.E.S. EXISTING DITCH PROPOSED LIGHT POLE (BY OTHERS) AREA OF EXISTING COARSE AGGREGATE ROCK (6" THICK) PROPOSED HEAVY DUTY CONCRETE KINGS HIGHWAY125' 125'80'80'125' 125'80'80'PROPOSED BUILDING 1 CITRUCELLO PLANT 10,000 S.F. F.F.E.= 21.50 PROPOSED BUILDING 2 (FUTURE PHASE) DISTRIBUTION CENTER 10,000 S.F. F.F.E.= 21.50 5' CONC. SIDEWALK 5' CONC. SIDEWALK RELOCATED 8' WIDE METAL & STUCCO PROJECT SIGN SC MH: 20 SA MH: 20 SB MH: 18 SA MH: 20 16 18 17 19.65 19 19.65 19 18 17 16 19.65 19 18 17 16 25' R / W DEDICATION SB MH: 18 PROPOSED DRY DETENTION AREA PROPOSED DRY DETENTION AREA 5' CONC. SIDEWALK EXISTING IRRIGATION WELL TO REMAIN INSTALL 87 LF 6" PVC SAN LATERAL @ 1.0% MIN. FOR DETAILS OF CONNECTION TO BUILDING SEE ARCHITECTUAL PLANS FOR DETAILS OF CONNECTION TO BUILDING SEE ARCHITECTUAL PLANS EXISTING WATER SERVICE ENTRY LOCATION CONNECT TO EX. CLEANOUT MIN EL= 19.77 (CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION) INSTALL 10 LF 2" PVC WATER MAIN INSTALL 2" 90° BEND (TYP.) PORTIONS OF PAVEMENT & CONCRETE TO BE REMOVED & REPLACED IN KIND 6' EASEMENTINSTALL 334 LF 6" PVC SAN @ 1.6% MIN. SOLID INTERCEPTOR (BY OTHERS) FOR DETAILS OF CONNECTION TO BUILDING SEE ARCHITECTUAL PLANS SOLID INTERCEPTOR (BY OTHERS) FOR DETAILS OF CONNECTION TO BUILDING SEE ARCHITECTUAL PLANS INSTALL 55 LF 6" PVC SAN LATERAL @ 1.0% MIN. INSTALL 7 LF 1" PVC WATER MAIN INSTALL 100 LF 2" PE FORCE MAIN AT MIN. 36" COVER INSTALL 8"X1" CROSS INSTALL 1" METER & RPZ INSTALL 1" METER & RPZ PROPOSED LIFT STATION TOP EL= 20.50 INFLUENT INV.= 10.71 (SEE DETAILS, SHEET C12) INSTALL 538 LF 8" PVC WATER MAIN INSTALL 123 LF 8" PVC WATER MAIN INSTALL 82 LF 8" PVC WATER MAIN INSTALL 153 LF 8" PVC WATER MAIN INSTALL 8"X2" TEE 2" METER & RPZ INSTALL 8" GV & PLUG INSTALL 8"X6" REDUCER INSTALL FIRE HYDRANT ASSEMBLY EX. SEPTIC TANK & DRAINFIELD TO BE ABANDONED PER FAC CHAPTER 64E-6 BY PLUMBING CONTRACTOR INSTALL 8" TEE 8" G.V. INSTALL 2" TEE (2) 2" GV & PLUG INSTALL 150 LF 6" PVC SAN @ 1.6% MIN.EXISTING SEPTIC AREA INSTALL CLEANOUT TOP= 20.08 INV.= 19.21 INSTALL 8" 90° BEND INSTALL 55 LF 2" PVC WATER MAIN INSTALL 52 LF 2" PVC WATER MAIN INSTALL 47 LF 6" PVC WATER MAIN INSTALL 7 LF 1" PVC WATER MAIN INSTALL 27 LF 1" PVC WATER MAIN INSTALL 31 LF 1" PVC WATER MAIN INSTALL 8" TEE 8" GV & 8"X4" REDUCER INSTALL 41 LF 6" PVC SAN @ 1.6% MIN. INSTALL 35 LF 6" PVC SAN @ 1.6% MIN. 2 3 6 8 5 7 9 10 INSTALL FDC & 18 LF 4" PVC INSTALL FDC & 18 LF 4" PVC INSTALL 26 LF 4" PVC FIRE LINE 90° BEND INSTALL 7 LF 4" PVC FIRE LINE 90° BEND INSTALL 4" DDCV INSTALL 32 LF 8" PVC WATER MAIN INSTALL 8"X4" TEE INSTALL 18 LF 4" PVC FIRE LINE 90° BEND INSTALL 4" DDCV 4 INSTALL CLEANOUT TOP= 20.72 INV.= 13.87 SS-1 RIM= 20.52 NW. INV.= 13.21 E. INV.= 13.11 PROPOSED 5'X5' TRANSFORMER PAD PROPOSED 4.5'X13' GENERATOR PAD 5 1 . 6 4 '54.51'EXISTING WET POND INSTALL 60 LF 8" HDPE WATER MAIN BY DIRECTIONAL BORE INSTALL 12"X8" TAPPING SLEEVE & 8" VALVE SAMPLE POINT #1 INSTALL 4"X2" WET TAP ASSEMBLY 6' MIN. SEPARATION EXISTING 4" SLCUD FM EXISTING 12" SLCUD WM 6' EASEMENT1 INSTALL 235 LF 8" PVC WATER MAIN INSTALL 427 LF 2" PE FORCE MAIN AT MIN. 36" COVER INSTALL 8 LF 8" PVC WATER MAIN 45° BEND 45° BEND INSTALL 170 LF 8" PVC WATER MAIN FLORIDAREVISIONSDATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055AJARON B WOL. No. 55313 STATE OF ROFL ADl RF O R P lSSE ANO lNEEE N GL ENSEClL AARON J. BOWLES FL. P.E. #55313 ES C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C9 UTILITY PLAN.dwg 9/24/2020 1:13 PM GREGGREEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTSC9UTILITY PLAN9/24/20201 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 UTILITY PLAN SCALE: 1" = 30' EXISTING ASPHALT EXISTING CONCRETE PROPOSED CONCRETE LEGEND PROPOSED ASPHALT Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE MATCH LINE A-AMATCH LINE A-A1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 UTILITY PLAN SCALE: 1" = 30' EXISTING DITCH PROPOSED LIGHT POLE (BY OTHERS) AREA OF EXISTING COARSE AGGREGATE ROCK (6" THICK) SAMPLE POINT LOCATIONSP-1 PROPOSED HEAVY DUTY CONCRETE KINGS HIGHWAY125' 125'80'80'125' 125'80'80'PROPOSED BUILDING 1 CITRUCELLO PLANT 10,000 S.F. F.F.E.= 21.50 PROPOSED BUILDING 2 (FUTURE PHASE) DISTRIBUTION CENTER 10,000 S.F. F.F.E.= 21.50 5' CONC. SIDEWALK 5' CONC. SIDEWALK RELOCATED 8' WIDE METAL & STUCCO PROJECT SIGN SC MH: 20 SA MH: 20 SB MH: 18 SA MH: 20 16 18 17 19.65 19 19.65 19 18 17 16 19.65 19 18 17 16 25' R / W DEDICATION SB MH: 18 PROPOSED DRY DETENTION AREA PROPOSED DRY DETENTION AREA REMOVE PLUG & CONNECT TO 2" G.V.APPROXIMATE LOCATION OF FUTURE FPUA WM APPROXIMATE LOCATION OF FUTURE FPUA FM FUTURE USE 826± LF 2" PVC FMPOSSIBLE FUTURE CONNECTION POINT POSSIBLE FUTURE CONNECTION POINT 6' EASEMENTFUTURE USE 62 LF 8" PVC WM FUTURE USE 25 LF 8" PVC WM FUTURE USE 11 LF 8" PVC WM 45° BEND, TYP. FUTURE USE 13 LF 8" PVC WM REMOVE PLUG & CONNECT TO 8" G.V. FUTURE USE 244 LF 8" PVC WM 11 PORTION OF PAVEMENT TO BE REMOVED & REPLACED IN KIND IF FM IS NOT DIRECTIONAL BORED 12 1314 RELOCATE GUY WIRES AS REQUIRED EXISTING WET POND PORTION OF FM TO BE ABANDONED PORTION OF WM TO BE ABANDONED FLORIDAREVISIONSDATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055AJARON B WOL. No. 55313 STATE OF ROFL ADl RF O R P lSSE ANO lNEEE N GL ENSEClL AARON J. BOWLES FL. P.E. #55313 ES C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C10 UTILITY PLAN 2.dwg 9/24/2020 1:13 PMGREGG REEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTSC10FUTURE USEUTILITY PLAN9/24/20201 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 FUTURE USE UTILITY PLAN SCALE: 1" = 30' EXISTING ASPHALT EXISTING CONCRETE PROPOSED CONCRETE LEGEND PROPOSED ASPHALT Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE MATCH LINE A-AMATCH LINE A-A1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 FUTURE USE UTILITY PLAN SCALE: 1" = 30' EXISTING DITCH PROPOSED LIGHT POLE (BY OTHERS) AREA OF EXISTING COARSE AGGREGATE ROCK (6" THICK) PROPOSED HEAVY DUTY CONCRETE ALL FUTURE CONNECTIONS TO FPUA LINES TO USE MOST CURRENT FPUA DETAILS AND SPECIFICATIONS CONSTRUCT 6" COQUINA ORLIME ROCK BASE COMPACTEDTO 98% MAX. DRY DENSITYPER AASHTO T-180 METHOD,ASPHALTIC CONCRETESTABILIZED SUBGRADE MIN. DEPTH6"6"1-1/2" TYPE SP-9.5LBR 40 MIX TO HOMOGENOUS MIXTURE.OF 12", COMPACTED TO 98% MAX. DRYDENSITY PER AASHTO T-180 METHOD,FLEXIBLE PAVEMENT SECTIONN.T.S.EXISTING SUB-GRADEEXISTING BASESAW-CUT AND TACKCOAT EXISTING EDGEEXISTING ASPHALTPROPOSED BASEPROPOSED SUB-GRADEPAVEMENT1'-0"PAVEMENT SAW-CUT AND BUTT JOINTN.T.S.PROPOSED ASPHALTON-SITE CONCRETE SIDEWALK DETAILN.T.S.MIN. 4"VARIES (SEE PLAN)AWAY FROM BUILDING 2% MAXCONCRETE(f'c=3000 p.s.i.)SLOPE TO SWALE OR AWAY UNREINFORCED PER AASHTO T-180 METHODTO 98% MAX. DRY DENSITYLBR 40 MIN. COMPACTED6" STABILIZED SUB-GRADEMIX TO HOMOGENOUS MIXTURE.PRE-CAST CONCRETE WHEEL STOP DETAILN.T.S.SECTIONFRONT ELEVATION1'-0"4'-0"6'-0"1'-0"(2 REQUIRED)ANCHORING#4 DOWELS FOR#4 DOWEL7"1'-0" MIN. 5" 12" 12"6"3'CURB TRANSITION DETAILN.T.S.C11GENERAL DETAILS 9/24/2020HANDICAPPED RAMP AND PAVEMENT MARKING DETAIL5'4"4.53 S.F.NOTE:USE OF PAVEMENT SYMBOL INHANDICAPPED PARKING SPACESIS OPTIONAL. WHEN USED THESYMBOL SHALL BE 3' OR 5' HIGHAND WHITE IN COLOR.2.7 S.F.3'4"GENERAL NOTES1. CRITERIA FOR PAVEMENT MARKING ONLY, NOT CURB CUT RAMP LOCATIONS.FOR RAMP CRITERIA REFER TO FDOT STANDARD DESIGN INDEX #304, LATESTEDITION.2. BLUE PAVEMENT MARKINGS SHALL BE TINTED TO MATCH SHADE 15180 OFFEDERAL STANDARD 595a.3. CURB AND WHEELSTOP LOCATIONS SHALL BE AS PER DEPICTED ON THEPLANS.4. FOR ANGLED PARKING APPLICATIONS, REFER TO FDOT STANDARD DESIGNINDEX #17346, LATEST EDITION.N.T.S.6"WHITEBLUE2"6"SIDEWALKBLUEWHITE6"2"6"5'MIN.SIGNFTP-20-06 &FTP-22-06CURB CUT RAMP6" WHITEPERLOCALCODE12'MIN.12'MIN.PERLOCALCODE90°STANDARD SPACE PAVEMENT MARKINGHANDICAPPEDPAVEMENTSYMBOLFTP - 22-06FTP - 20-06GENERAL NOTES1. TOP PORTION OF FTP-20-06 SHALL HAVE A REFLECTIVE BLUE BACKGROUNDWITH WHITE REFLECTIVE SYMBOL AND BORDER.2. BOTTOM PORTION OF FTP-20-06 SHALL HAVE A REFLECTIVE WHITEBACKGROUND WITH BLACK OPAQUE LEGEND AND BORDER.3. THE SIGN SHALL BE PLACED A MINIMUM OF 3' FROM THE WHEEL STOP OR THEBACK OF CURB (WHERE APPLICABLE).1' x 6"1-1/2" RADII3/4" BORDER1" SERIES C LETTERSWHITE BACKGROUNDBLACK LEGEND & BORDERSIGNS USED AS PER FLORIDA STATUTESFTP - 20-06: PER FS 316.195512'-0" x 2" x 2" 12 GAUGEHOT DIPPED GALV.SQUARE POSTSIDEWALK ORNATURAL GROUND12"18"6"7'-0"3'-0"ALL LETTERS1" SERIES "C"R 1.5"1.5"6"1"1"1"1"1"1"1"1"1"1.5"12"6"2.7"6.6"2.7"1"1.5"1"1"1.5"0.5"HANDICAPPED SIGN DETAILN.T.S.18"8"6"R 2"6"FDOT TYPE 'D' CURBN.T.S.4" CONCRETESIDEWALK, 28 DAY 3000PSI, BROOM FINISHASPHALTICCONCRETELIMEROCK BASESTABILIZED SUB-GRADEWHEEL STOPSEE DETAILCONCRETE TO RUNFLUSH WITH ASPHALTCOMPACTED FILL(MIN 6"), 98% AASHTOT-180 DENSITYCONCRETE SIDEWALK ADJACENTTO ASPHALT PARKINGN.T.S.SEE DETAIL20'-0"6" STEEL BOLLARDFILLED W/CONCRETE3'D+2' D10'6"3'DRILL HOLES IN CONCRETE10'SLATS DETAIL8"MIN.TYPICAL DOUBLE SWING GATE W/SLATSCHAIN LINK FENCE DUMPSTER ENCLOSURE DETAILN.T.S.SEE DETAIL6" STEEL BOLLARDFILLED W/CONCRETE3'D+2' D10'6"3'DRILL HOLES IN CONCRETEDIVIDER WALL OPTIONAL10'(PER FDOT INDEX #310)(PER FDOT INDEX #17355)EXISTING CONTROL STRUCTURE DETAILN.T.S.0.25'BLEEDER DETAILBOT. EL. = 14.00BLEEDER EL. = 15.00GRATE EL. = 19.58TYPE "E" INLET0.25' DIA. BLEEDER15" CMPINV. EL.= 14.94FLORIDA REVISIONS DATE 1835 - 20TH STREET VERO BEACH, FL 32960 PH. (772) 569-0035 FX. (772) 778-3617 MELBOURNE, FL - PH (321) 253-1510 FT. PIERCE, FL - PH (772) 468-9055 A JA RONBWOL.No. 55313STATE OFROFLADlRFORPlSSEANOl N EEENGL ENSEClLAARON J. BOWLESFL. P.E. #55313ESC:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 COVER-DETAILS.dwg 9/24/2020 1:19 PM GREGGREED ST. LUCIE COUNTY INDIAN RIVER SPIRITS SITE IMPROVEMENTSSLOPE PER PLANVARIES6"2'-0"6"6"4"6"4"6"4"6"3'-0"6"6"ENERGYDISSIPATORSPAVING10'-0"EOP EOP AA24"6"12" 6"8"7-1/2"(6" MIN.)R 2"R 3"R 3/4"FDOT TYPE 'F' CURBN.T.S.INV. EL. = 17.60TO BE INSTALLEDPROP/ 15" SLOT WEIRFDOT INDEX #425-024 CURB INLETN.T.S.RIM ELEV.5" UNREINFORCED CONCRETE(f'c=3000 p.s.i)6" STABILIZED SUBGRADE FBV OF 50p.s.i. COMPACTED TO 98% MAXIMUMDRY DENSITY PER AASHTO T-180METHOD MIX TO HOMOGENOUSMIXTURE.6" REINFORCEDCONCRETE FIBERCRETE(f'c=4000 p.s.i)12" STABILIZED SUBGRADE FBV OF 50p.s.i. COMPACTED TO 98% MAXIMUMDRY DENSITY PER AASHTO T-180METHOD MIX TO HOMOGENOUSMIXTURE.LIMEROCK OR COQUINABASE6x6 10/10 WWMREINFORCED ATMID-DEPTHASPHALTICCONCRETECONCRETE SIDEWALK ADJACENTTO PAVEMENT DETAILN.T.S.STABILIZED SUBGRADE1 #4 BAR CONTINUOUSSLOPE PER PLAN(2% MAX)1. CONTRACTOR TO PROVIDE HAND TOOLED TRANSVERSE AND LONGITUDINALCONTRACTION JOINTS @ 5'-0" O.C. MAX. 3/8" EXPANSION JOINTS @ 25'-0" O.C. MAX.2. IN LIEU OF WELDED WIRE FABRIC, FIBER MESH CONCRETE MAY BE USED.3. FINISH EDGE OF SIDEWALK WITH EDGING TOOL HAVING A RADIUS OF 1/2".MIN. 4" THICK CONCRETESIDEWALK, 28 DAY 3000 PSI,BROOM FINISHMIN. 6" COMPACTED FILL, 98%AASHTO T-180 DENSITYEXPANSION JOINTVARIES6"MIN.SEE PLANHEAVY DUTY CONCRETE DETAILN.T.S.REGULAR DUTY CONCRETE DETAILN.T.S.FDOT INDEX #522-002 SIDEWALK CURB RAMP DETAILSN.T.S. C12UTILITY DETAILS 9/24/2020FLORIDA REVISIONS DATE 1835 - 20TH STREET VERO BEACH, FL 32960 PH. (772) 569-0035 FX. (772) 778-3617 MELBOURNE, FL - PH (321) 253-1510 FT. PIERCE, FL - PH (772) 468-9055 A JA RONBWOL.No. 55313STATE OFROFLADlRFORPlSSEANOl N EEENGL ENSEClLAARON J. BOWLESFL. P.E. #55313ESC:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 COVER-DETAILS.dwg 9/24/2020 1:19 PM GREGGREED ST. LUCIE COUNTY INDIAN RIVER SPIRITS SITE IMPROVEMENTS C13UTILITY DETAILS 9/24/2020FLORIDA REVISIONS DATE 1835 - 20TH STREET VERO BEACH, FL 32960 PH. (772) 569-0035 FX. (772) 778-3617 MELBOURNE, FL - PH (321) 253-1510 FT. PIERCE, FL - PH (772) 468-9055 A JA RONBWOL.No. 55313STATE OFROFLADlRFORPlSSEANOl N EEENGL ENSEClLAARON J. BOWLESFL. P.E. #55313ESC:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 COVER-DETAILS.dwg 9/24/2020 1:19 PM GREGGREED ST. LUCIE COUNTY INDIAN RIVER SPIRITS SITE IMPROVEMENTS C14LIFT STATION DETAILS 9/24/2020FLORIDA REVISIONS DATE 1835 - 20TH STREET VERO BEACH, FL 32960 PH. (772) 569-0035 FX. (772) 778-3617 MELBOURNE, FL - PH (321) 253-1510 FT. PIERCE, FL - PH (772) 468-9055 A JA RONBWOL.No. 55313STATE OFROFLADlRFORPlSSEANOl N EEENGL ENSEClLAARON J. BOWLESFL. P.E. #55313ESC:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 COVER-DETAILS.dwg 9/24/2020 1:20 PM GREGGREED ST. LUCIE COUNTY INDIAN RIVER SPIRITS SITE IMPROVEMENTS PVC 4" PVC @ RIGHT OF WAY30" MIN.INCREASERPVC" PRDISCHARGE LINEFRP VALVE BOXFIN GRADE PLUG VALVE 3,3402.41230/31-1/4"5-2/3"21.0021.0010.7110.219.719.218.717.211-1/4"x 2"22430302200481-1/41-1/44.411.42'87.92' PVC DISCHARGELINEVENTS.S. HINGES2" PVC DRAIN LINELIFT STATION PLANFIBERGLASS ACCESS HATCH & COVER (LOCKABLE)FIBERGLASS WET WELL PVC DISCHARGESCH 80 PVC UNION OR FLANGE FIBERGLASS VALVE BOXW/ QUICK CONNECT CPLG.EMERGENCY PUMP OUTEL. EL. FIELD INSTALLED INLET" 2ELECTRICAL CONDUITSKNOCKOUTS FOR(2-3) FIELD INSTALLEDEL. 2" SIZESLOPELIFTING BAILSS PUMP CONTRACTOR INSTALL GROUT 1.5:1PUMP DISCHARGE WITHSLIDE RAILS ( SCH 40 AISI 304SS PIPE)" 2" PVC VENTW/SCREENBRACKETCABLE HOLDING(S.S.)CABLESS LIFTINGWITH BOTTOM SLABCONCRETE GROUT AS REQ'DBY ENGINEER TO PREVENTFLOTATION3YDMAKE MONOLITHIC POURFILL BOX AS NEEDED WITHCONCRETE TO PROVIDEPROPER DRAINAGE & BALLASTCHECK VALVE SCH 80 PVC2' MIN. SEALING FLANGE" " 2" PVC DRAIN("P-TRAP") PLUG VALVE"T"" " ( X X D)EMERGENCY PUMP OUTW/ QUICK CONNECT CPLG." FIBERGLASS VALVE BOXINCREASERPVC LIFT STATION SECTIONCONCRETE BASE SLAB AS PER SPECIFICATIONS W/ # 4 REBAR 18" O.C.BASIN ANTI-FLOTATION FLANGE" REDUCED PRESSURE (RPZ) BACKFLOW PREVENTERTO BE INSTALLED IN WATER SUPPLY LINE TO LIFT STATION.LIFT STATION "FEBCO MODEL #825Y OAE"TO BE INSTALLED IN WATER SUPPLY LINE TO REDUCED PRESSURE (RPZ) BACKFLOW PREVENTER2"3/4 GALV RISERSLEEVE REQUIREDITCH DISCONNECTCONTROL PANEL UNISTRUT (OR EQ.)3/4 HOSE BIBB GENERATOR RECEPTOR SW12" Ø x 24" DEEP0R CONC. AROUND POSTSTO WATER SUPPLYCONC. SLAB 48" Lx12" Wx10" DTO SERVICE LOCATION (VERIFY W/POWER CO.)GROUND RODELECTRICIANFIELD MOUNTED BYLIGHTNING ARRESTOR5' MAX 2" GAL. PIPE OR EQUIV.POSTSTO PUMP NO. 1TO PUMP NO. 2WATER LEVEL CONTROLELECTRIC METER(CONTRACTOR LOCATE)(2)- 2" CONDUITS REQ'D FOR 2 HP PUMPSSEAL OFFS(3)- 2" CONDUITS REQ'D FOR 3 HP ANDLARGER PUMPS.(2")A3042 (O.A.E.)ELECTRICAL RISER NOTE:GRADEMODEL NO.-SCRCSRCTRFRETMAHAHSLA---START CAPACITOR (1Ø)RUN CAPACITOR (1Ø)START RELAY (1Ø)- CONTROL TRANSFORMER------FLOAT REGULATORELAPSED TIME METERALARM HORNALARM HORN SILENCERLIGHTNING ARRESTORPTS PUMP TERMINAL STRIPCOMPONENT LEGEND- OVERLOADO/LNRGRDFSRTS----NEUTRALRELAYSGROUNDFUSEREGULATOR TERMINAL STRIP-CIRCUIT BREAKERC/BMOTOR CIRCUIT PROTECTOR-MCP----MOTOR STARTERPUMP RUN INDICATORS-EMER GENERATOR RECEPTACLE--CONTROL CIRCUIT BREAKERMAIN CIRCUIT BREAKEREMERGENCY CIRCUIT BREAKER-- PUMP 1/PUMP 2OVERLOAD HEATERSMSRLEGRCCBMCBECBP1/P2OL--HAND-OFF-AUTOMATIC SWITCHDUPLEX GRND. FAULT RECEPT.PUMP AUTOMATIC ALTERNATOR-VOLTAGE/PHASE MONITORINCOMING POWER TERM. BLOCK-NEUTRAL TERM. BLOCK-HOAGFIALTVM/PMIPTBNTBsuitable bond between the glass reinforcement and the resin.1. Soil modulus of 700 psi.3. Luschers safety factor of 2.0.Material for the FRP shall be as follows:Resin: The resins used shall be a commercial grade unsaturated polyester resin.Reinforcing Materials: The reinforcing material shall be commercial grade "E" type glassin the form of mat, chopped or roving fabric, having a coupling agent that will provide a2. Soil density of 120 lbs/ftINSTALLATION - shall be in strict accordance with the manufacturer's instructions andrecommendations in the locations shown on the drawing.INSPECTION AND TESTING - A factory representative shall be provided for one (1) dayand shall have complete knowledge of proper operation and maintenance to inspect thefinal installation and supervise the test run of the equipment.Megger the motor. The pump motors shall be megged out prior to startup to ensure theinsulation of the pump motor/cable system is intact.3.01 Part 3 - Execution.3.02 Fillers and Additives: Fillers of any type shall not be utilized. Additives, such as thixotropicagents, catalysts, promoters, etc., may be added as required by the specific manufacturingprocess to be used to meet the requirements of this specification.The pump controls and pumps shall be checked for mechanical reliability and proper operation.CONTROL PANEL AND WETWELL, PER MANUFACTURER'S SPECIFICATIONS.7. ELECTRICIAN TO RUN TWO / THREE SEPARATE 2" CONDUITS(ONE EACH FOR HIGH & LOW VOLTAGES) PER ELECTRICAL CODE BETWEEN6. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES.*NOTES:1. ALL DIMENSIONS ARE IN FEET EXCEPT AS NOTED.2. DRAWING IS NOT TO SCALE.3. ALL DIMENSIONS AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.4. PAINT EXPOSED FRP AS REQUIRED BY OWNER/ENGINEER.5. F.R.P. INDICATES FIBERGLASS REINFORCED POLYESTER.**DISCONNECT (AHEAD OF THE PUMP CONTROL PANEL).10. ELECTRICIAN TO MOUNT LIGHTNING ARRESTOR AT SWITCH*NOTES FOR ELECTRICIAN11. BOTH WETWELL AND VALVE BOX SHALL BE PROVIDED WITH A MEANSFOR LOCKING.12. CONTRACTOR SHALL FIELD INSTALL INLET FITTING AT PROPER ELEVATION.13. ALL HARDWARE AND FASTENERS SHALL BE STAINLESS STEEL.14. CONTRACTOR SHALL VERIFY POWER SOURCE PRIOR TO ORDERING EQUIPMENT. AND INSIDE OF CONTROL PANEL.8. ALUMINUM WIRE SHALL NOT BE USED BETWEEN MAIN METERAND CONTROL PANEL.9. ELECTRICIAN SHALL SEAL OFF CONDUIT RUNS INSIDE WETWELL*HEATERN84NNN83NALHORNOHHO1111ALARMT'STATIN PUMPT'STAT2METPRLMCP2MCP1CTR-NNHORNALARMLIGHT28HIGHCTR-NPRLETAA181420161MIN PUMPPUMP 1PUMP 2NALARMLEVELR187SILENCE2828INCLUDED UNLESSR2R25 3873838MCP2MCP1CCBMCBCONTACTORSRSC & RCPTSSEAL LEAK 2N46452M1M41SEAL LEAK 14141NV, PH, 60HZ, 4W1111R2CCB(15A)GFIFS234135R124236 21028HIGH LEVEL87632111112711OFFFR1FR3FR2LEADLAG2M1M12133427271111133434ALTVM13104124VAC100VA120VAC41FR4FR3LAG 2 10HLA IN PUMP18P 21PFR4T'STAT 2814 208316 N 84NSEAL 1 2SEAL 1 T'STAT 2 3 PH SERVICESPECIFICALLY DELETED.RECEPTACLE1. SCHEMATIC DEPICTS EMERGENCY GENERATORNOTES:2. START/RUN CAPACITORS DELETED FORNEUTRALBLOCKGROUND LUGCTRECBALT.RELAYINPUT TERMINALSPOS. 1POS. 2120/24VVM/PMGROUNDRTSSUB PANEL LAYOUT "TYPICAL" N/SLUGSbe UL listed.The following shall be included:1. Flasher and alarm horn with silence alarm resetmounted on the outside of the enclosure2. Emergency generator receptacle (EGR) if required3. Lightning arrestor. A lightning arrestor shall be field mountedby electrician at the switch disconnect ahead of the control panelThe lightning arrestor shall meet or exceed the requirementsof ANSI/IEEE Std. C62.1-latest edition section 8.6.1. and 8.7.3. and2.03Pump lifting devices shall be made of AISI 304SS (min.) cable (1/4" min.) or 304SS chainFASTENER and APPURTENANCES - All fasteners, lifting cables, float cable bracket andSlide rails shall be SCH 40 AISI 304SS pipeAn aluminum slide/latch assembly shall be provided for holding the doors open on both4. Four float duplex system. The third float shall energizethe lag pump. The fourth float shall energize the alarm.5. Elapsed time meters. Non-resettable elasped time metersshall be mounted on the deadfront to indicate pump runtime.6. Phase/voltage monitor control device for protection of pumpmotors from either loss of phase (3Ø) or low voltage.appurtenances shall be made of AISI 304SS or other material inert to the highly corrosiveatmosphere of a sewage lift station. Hinges for the wet well and valve box shall be AISI304SS minimum.the wet well and the valve box.2.04 LA FIELD INSTALLED @ SWITCHLANL2L1DISCONNECTL1/L2/N/Grnd. TO CONTROL PANELof sufficient size, with safety factor to handle safely the specific pumps. AISI 304SS (min.)FRP PRODUCTS - The pump wetwell shall be manufactured of fiberglass reinforcedpolyester (FRP) of diameter and depth as shown on the lift station elevation detail. Thebasin/wetwell wall thickness shall be adequate for the depth of the tank to maintainstructural integrity in the followint condition:pump lifting bails shall be provided.EGRMCBECBVM/PM27O/LO/LPUMP 2PUMP 1C/BC/BMCP1MCP2RC2SC2SR21551SR1SC1 RC11T11T2 2T1 2T21M2M1W1RELECTRICIAN INPUT CONNECTION BLOCKFR2FR1LEADOFF 11 27 11 1 11WITH GUARDALARM LIGHT2BP 2221B2R 2WP 1GENERATORRECEPTACLEHORNSILENCEHOUR METERh00001,00HOUR METERh00001,00HORNSEAL LEAK INDICATORSHOAsINTERLOCKCIRCUIT BREAKERETMsPUMPS RUN LIGHTS1 2OFFHAND AUTO HAND AUTOOFFPUMP ON12GFI RECEPT.DEAD FRONT LAYOUT "TYPICAL" N/SENCLOSURE - N.E.M.A. 3R AISI 304SSW/ALUMINUM DEAD FRONT CONSTRUCTIONAND LOCKING HASPDUPLEX PUMP CONTROL PANELSPECIFICATIONS_____ feet Total Dynamic Head (TDH). Pumps shall be capable of handling domesticPart 1 - General1. 01 Furnish and install two non-clog pumps to deliver _____ GPM against a total head ofNON CLOG PUMP SPECIFICATIONpumping unit. Pump discharge size shall be _____ inch. Pump, control system, and_____ VOLT/_____ PHASE/ 60 HERTZ. The motor shall be an integral part of thesewage with minimal maintenance. The motor shall be _____ HP, ____ RPM, Part 2 - Productswetwell shall be as noted on plans or approved equal, provided and manufactured byGerber Pumps, Inc.with an integrally built submersible type motor. The pump shall be mounted in the 2.01 PUMP - Pump shall be of the centrifugal non-clog type _____ Model _____ or equalSeal - Motor shall be protected by mechanical seal. Seal faces shall be lubricatedFRP basin in such a way that solids are fed in an up-flow direction to the impeller.All bolts, nuts, washers, lock washers, and machine screws shall be stainless steel. The deadfront shall be held closed by an easily opened locking device. All components2 Manual overload resets1 Duplex GFI convenience receptacle 1 Main circuit breaker (if EGR used)1 Emergency circuit breaker (if EGR used)2 Pump run indicator lights2 Hand-off-auto switches2 Two pole pump circuit protectors with on/off switch (1 Ø), three pole (3 Ø)1 Control/Convenience receptacle circuit breaker44.026.044.026.06.015PUMP SYSTEM MANUFACTURERndCHARTstF.L.A. TOTALa2 PUMP ONHIGH LEVEL ALARMINLET INVERTTOP OF WETWELLTOP OF VALVE BOXdcbaELEVATION 9.4-VOLTS/PHASEMIN.GPMFTGPMFTGPMF.L.A. PER PUMPBOTTOM OF WET WELLPUMPS OFF1 PUMP ONgfe121110987654321PUMP DATA CHARTPUMP CYCLE TIMEPUMP MODEL NO. R.P.M.HORSE POWERPRIMARY PUMP CAPACITYPRIMARY TDHSECONDARY PUMP CAPACITYSECONDARY TDHPEAK INFLUENT FLOW RATEFULL LOADAMP.ELECTRICAL1513PUMP DISCHARGE SIZE14IMPELLER DIA.MIN. DIA. SOLIDSABS LEVEL CONTROL BOTTOM EL. INLETPUMPS OFF EL. 2ND PUMP ON EL. 1ST PUMP ON EL. H.L.A. EL.TOP EL.INVERT EL.DIAGRAMPIR S20/2W 9.4(SPECIFICATIONS MAY DIFFER BASED ON MANUFACTURER)Motor - shall have two heavy duty ball bearings to support the pump shaft and takeradial and thrust loads. Ball bearings shall be designed for 50,000 hours B-10 life.Stator shall be heat shrunk into the motor housing. On single phase motors a linebreak overload shall be attached to the windings to stop the motor if the temperatureof the winding is more than 130°C. This overload will automatically reset when themotor cools to safe operating temperature. On three phase motors overcurrentprotection should be provided in the control panel. The common pump-motor shaftshall be of AISI 416 stainless steel.by the oil-filled motor housing above the seal. Faces shall be carbon and ceramicand lapped to a flatness of one light band. Seal faces of tungsten carbide are optional.Impeller - Shall be cast iron and of the 2 vane non-clog enclosed type capable ofpassing _____ " dia. solids.Vane inlet tips shall be carefully rounded to prevent stringy material from catching inthe vanes. Pump-out vanes shall be used on front and back shrouds and impellershall be dynamically balanced by grinding on shroud faces. Impeller shall be drivenby stainless steel shaft key and held in place with lock screw and washer.Impeller and motor shall lift off case as a unit without disturbing discharge piping.Pump Case - The volute case shall be cast iron and have a flanged center linedischarge. Discharge flange shall be _____ inch standard with bolt holes straddlingcenter line.Pump and Motor Casting - All castings shall be of high tensile cast iron and shall betreated with phosphate and chromate rinse. All fasteners shall be 304 stainless steel.Power Cables - Power cables shall be double sealed. Cable entry into cord cap shallbe sealed by a cord grip fitting. Individual wire entry into top of motor housing shall bebe sealed by a rubber compression sealing grommet.Insulation of power cable shall be type SOW/SOW-A.Duplex Pump Control Panel - Each non-clog pump control panel shall control two_____ HP, _____/ _____/ 60 Hz. non-clo pumps. The four float control system shalloperate on _______ service.24 voltThe enclosure shall be NEMA 3R, minimum 24" High, 20" wide, 8" deep, fabricated from AISI 304 stainless steel with provision for padlocking. The backpanel and hingeddeadfront shall be constructed of corrosion resistant T6065 alloy aluminum.The enclosure shall have external mounting feet to allow for wall mounting.mounted to or protruding through the deadfront shall be identified by lettering engravedin 2 ply phenolic engraving stock.The following components shall be mounted through the deadfront:The following shall be mounted to the backpanel:2 Motor circuit protectors providing single phase sensitivity and Class 10 ambient temperature compensated thermal overload protection as defined in NEMA Standards (Part ICS 2-222) and complying with IEC-292 and IEC-157-1 Standards. Definite purpose contractors are not acceptable.2 Start capacitors sized to match motor requirements, 1 Ø.2 Run capacitors sized to match motor requirements, 1 Ø.2 Start relays sized to match motor requirements, 1 Ø.1 24 volt control transformer1 Strip heater to prevent corrosion due to condensation8 Terminals for float connections2 Ground lugELECTRICIAN TO FIELD WIREgba12THRUaSEE ELEVATION CHART FOR ggcdefab109111113781413101111SEE PUMP DATA CHART FOR THRU114N/A GRINDER 15' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER KINGS HIGHWAY125' 125'80'80'125' 125'80'80'PROPOSED BUILDING 1 CITRUCELLO PLANT 10,000 S.F. F.F.E.= 21.50 PROPOSED BUILDING 2 (FUTURE PHASE) DISTRIBUTION CENTER 10,000 S.F. F.F.E.= 21.50 5' CONC. SIDEWALK 5' CONC. SIDEWALK RELOCATED 8' WIDE METAL & STUCCO PROJECT SIGN SC MH: 20 SA MH: 20 SB MH: 18 SA MH: 20 16 18 17 19.65 19 19.65 19 18 17 16 19.65 19 18 17 16 25' R / W DEDICATION SB MH: 18 PROPOSED DRY DETENTION AREA PROPOSED DRY DETENTION AREA QV 2 QV 2 SP 6 IA 1 ± 264' LIMITS OF LANDSCAPE IMPROVEMENTS ± 190' LIMITS OF LANDSCAPE IMPROVEMENTS QV 2 FB 117SEE LANDSCAPE MATERIAL PLANTING NOTE (TYP.)20' MIN.TO OHW30' MIN. TO OHW 20' MIN.15'x15' VISIBILITY TRIANGLE IA 1 IA 1 GL 1 GL 1 PROVIDE ROOT BARRIER SYSTEM AT ISLAND PERIMETER ± 45 LF ± 112 SF SOD PARKING AREA INTERIOR LANDSCAPE AREA PROVIDE ROOT BARRIER SYSTEM AT ISLAND PERIMETER ± 40 LF ± 180 SF SOD PARKING AREA INTERIOR LANDSCAPE AREA ± 180 SF SOD PARKING AREA INTERIOR LANDSCAPE AREA PROVIDE ROOT BARRIER SYSTEM AT ISLAND PERIMETER ± 45 LF SP 7 IA 1 SP 8 GL 1 FB 80 QV 1 SP 3 GL 1 SP 3 FB 69 EXISTING 24" OAK TO SERVE AS END OF ROW PARKING TREE FB 23 IA 1 IA 1 EXISTING RELOCATED LIVE OAK QV 1 CP 11 QV 1 GL 1 PROVIDE ROOT BARRIER SYSTEM AT ISLAND PERIMETER ± 60 LF ± 223 SF SOD PARKING AREA INTERIOR LANDSCAPE AREA PROVIDE ROOT BARRIER SYSTEM AT ISLAND PERIMETER ± 60 LF ± 223 SF SOD PARKING AREA INTERIOR LANDSCAPE AREA IA 1 IA 1 ± 280 SF SOD PARKING AREA INTERIOR LANDSCAPE AREA ± 280 SF SOD PARKING AREA INTERIOR LANDSCAPE AREA PROVIDE ROOT BARRIER SYSTEM AT ISLAND PERIMETER ± 64 LF PROVIDE ROOT BARRIER SYSTEM AT ISLAND PERIMETER ± 64 LF SOD LANDSCAPE BUFFER AS NEEDED (TYP.) EX. OAKS TO BE REMOVED EX. OAK TO BE RELOCATED EX. OAK TO BE REMOVED THESE TREES ARE BEING PRESERVED ON-SITE THESE TREES ARE BEING PRESERVED ON-SITE FB 150 IA 6 3 OAKS OFF EDGE TO MEET MITIGATION CP 11 MC 10 W / 3 FT. RADIUS OF LANDSCAPE AREA PER LDC 9.02.01D C15LANDSCAPE PLAN9/24/2020Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 60 30 LANDSCAPE PLAN SCALE: 1" = 30' EXISTING ASPHALT EXISTING CONCRETE PROPOSED CONCRETE LEGEND PROPOSED ASPHALT AREA OF EXISTING COARSE AGGREGATE ROCK (6" THICK) 1. BUFFERS WEST PROPERTY LINE (SLC LDC SECTION 7.09.04(A)) REQUIRED: 15' WIDE BUFFER ALONG KINGS HIGHWAY (WEST P.L.) ± 255 LF - 29 LF DRIVEWAY = ± 226 LF 1 TREES PER 30 LF = 8 TREES CONTINUOUS HEDGE PROVIDED: 15' WIDE BUFFER ALONG KINGS HIGHWAY (WEST P.L.) TREES := 8 TREES 3 EXISTING AND 6 PROPOSED PALMS (3 TREES @ 3:1) , 1 EXISTING RELOCATED OAK AND 3 PROPOSED OAKS 1 PROPOSED GUMBO LIMBO SHRUBS = EXISTING WAX MYRTLE HEDGE TO BE AUGMENTED WITH 92 ADDITIONAL FIREBUSH TO PROVIDE A CONTINUOUS HEDGE NORTH PROPERTY LINE (SLC LDC SECTION 7.09.04(b)) REQUIRED: 10' WIDE LANDSCAPE BUFFER ALONG NORTH P.L. ± 190 LF (WITHIN LIMITS OF DEVELOPMENT) 1 TREE PER 30 LF = 7 TREES HEDGE 4' HIGH AT PLANTING PROVIDED: 10' WIDE LANDSCAPE BUFFER ALONG NORTH P.L. TREES : = 7 TREES 7 PROPOSED TREES (1 GUMBO LIMBO 1 HOLLY AND 15 PALMS @ 3:1) 4' HIGH HEDGE (80 FIREBUSH) SOUTH PROPERTY LINE (SLC LDC SECTION 7.09.04(b)) REQUIRED: 10' WIDE LANDSCAPE BUFFER ALONG SOUTH P.L. ± 263 LF (WITHIN LIMITS OF DEVELOPMENT) 1 TREE PER 30 LF = 9 TREES HEDGE 4' HIGH AT PLANTING PROVIDED: 10' WIDE LANDSCAPE BUFFER ALONG SOUTH P.L. CANOPY TREES: = 9 TREES 9 PROPOSED TREES (4 OAKS, 2 HOLLIES, 1 GUMBO LIMBO AND 6 PALMS @ 3:1) 4' HIGH HEDGE (117 FIREBUSH) TOTAL REQUIRED THIS SECTION TREES 24 SHRUBS CONTINUOUS HEDGE (4' H. AT NORTH AND SOUTH PROPERTY LINES) TOTAL PROVIDED THIS SECTION TREES 24 (1 RELOCATED TREE, 13 PROPOSED TREES, 3 EXISTING AND 27 PROPOSED PALMS) SHRUBS 289 SHRUBS + EXISTING SHRUBS FORMING A CONTINUOUS SCREEN (4' HIGH AT NORTH AND SOUTH PROPERTY LINES) 2. PARKING AND OTHER VEHICULAR USE AREA INTERIOR LANDSCAPE (SLC LDC SECTION 7.09.04(c)) REQUIRED: 1 SF OF LANDSCAPING PER 18 SF OF PARKING AND VEHICULAR USE AREA MINIMUM OF 180 SF IN SIZE WITH A 10' MINIMUM WIDTH 1 TREE PER ISLAND 18,310 SF OF PARKING AND VEHICULAR USE AREA 18,310 SF / 18 SF = 1,017 SF LANDSCAPING AREA REQUIRED 7 PARKING ISLANDS = 7 TREES REQUIRED PROVIDED: 1,478 SF OF LANDSCAPE AREA PROVIDED TREES : = 7 TREES 7 PROPOSED TREES (2 GUMBO LIMBO, 2 SABAL PALM AND 3 HOLLY) LANDSCAPE CALCULATIONS QV 1 SPECIES QUANTITY CALLOUT SYMBOL LEGEND 3200 N. KINGS HIGHWAY 713 SHORE DRIVE MARKUS & ANNEMARIE PORTMANN VERO BEACH, FLORIDA 32963 FORT PIERCE, FLORIDA 34951 SITE ADDRESS OWNER/APPLICANT SITE INFORMATION ENGINEER PHONE (772) 569-0035 VERO BEACH, FLORIDA 32960 1835 20TH STREET MBV ENGINEERING, INC. 1325-233-0000-000-7 TAX PARCEL I.D. NUMBER(S) ZONING LAND USE CG & AR-1 MXD SURVEYOR PHONE (772) 569-7880 VERO BEACH, FLORIDA 32960 1835 20TH STREET INDIAN RIVER SURVEY, INC. PHONE (772) 569-0066 ARCHITECT PHONE (772) 538-5130 VERO BEACH, FLORIDA 32963 STAFFAN H. LUNDBERG ARCHITECT, LLC LANDSCAPE MATERIAL PLANTING NOTE: IN AREAS OF EXISTING COARSE AGGREGATE ROCK (6" THICK) WHERE NEW LANDSCAPE MATERIAL IS TO BE PLANTED; COMPLETELY REMOVE AGGREGATE ROCK, AND PLANT PROPOSED LANDSCAPE MATERIAL PER LANDSCAPE DETAILS AND SPECIFICATIONS ON SHEETS C14 & C15. PARKING AREA INTERIOR LANDSCAPE AREA FDOT RIGHT-OF-WAY DEDICATION NOTE: FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT) REQUIRES ADDITIONAL 25' RIGHT-OF-WAY DEDICATION, FOR FUTURE ROADWAY AND SWALE IMPROVEMENTS. ALL EXISTING LANDSCAPE MUST BE REMOVED FROM THE DEDICATED AREA AND RELOCATED IN THE NEW BUFFER. LIMITS OF CONSTRUCTION TOTAL REQUIRED (ALL SECTIONS) CANOPY TREES 29 SHRUBS CONTINUOUS HEDGE (4' H. AT NORTH AND SOUTH PROPERTY LINES) TOTAL PROVIDED (ALL SECTIONS) CANOPY TREES 29 (1 EXISTING TREES, 18 PROPOSED TREES, 3 EXISTING AND 27 PROPOSED PALMS) SHRUBS 311 SHRUBS + EXISTING SHRUBS FORMING A CONTINUOUS SCREEN (4' HIGH AT NORTH AND SOUTH PROPERTY LINES) TREE PROTECTION NOTES: (A) ALL TREES RETAINED ON A SITE SHALL BE PROTECTIVELY BEFORE AND DURING CONSTRUCTION ACTIVITIES. (B) UNDERGROUND UTILITY LINES SHALL BE ROUTED AROUND EXISTING TREES TO THE OUTSIDE OF THE DRIPLINE WHERE ABLE. (C) INSTALLATION OF FENCES AND WALL SHALL TAKE INTO CONSIDERATION THE ROOT SYSTEMS OF EXISTING TREES. (D) FENCE/ BARRICADE SHALL BE INSTALLED AT PERIMETER OF ALL TREES OR GROUPS OF TREES TO BE PRESERVED. FENCE SHALL BE MAINTAINED DURING CONSTRUCTION. LAND CLEARING NOTES: (A) ALL NATIVE UPLAND VEGETATION CONTRIBUTING TO THE STABILIZATION OF BANKS OR EXISTING CANALS, DITCHES OR NATURAL WATERCOURSES SHALL BE RETAINED. (B) ALL NUISANCE EXOTIC VEGETATION EXISTING ON SITE SHALL BE REMOVED IN CONJUNCTION WITH ANY SITE DEVELOPMENT. (C) ANY ABANDONED FLOW WELLS EXISTING ON SITE SHALL BE PLUGGED IN CONJUNCTION WITH SITE DEVELOPMENT. * COCONUT PALMS APPEAR TO BE NEWLY PLANTED AND ARE AN EXOTIC SPECIES AND THEREFORE DO NOT COUNT TOWARDS MITIGATION FOR REMOVAL OR CREDIT. THEY ARE LISTED HERE SOLELY TO ALERT THE CONTRACTOR TO THEIR PRESENCE. ** ONLY 12" DBH AND LARGER TREES MAY BE COUNTED TOWARDS PRESERVATION/ MITIGATION. SMALLER DBH TREES ARE LISTED FOR REFERENCE ONLY TREE TOTAL DBH = 238 (12" DBH AND ABOVE) MINUS DBH OF TREES TO REMAIN (226) (12" DBH AND ABOVE) TOTAL DBH OF DBH REQUIRING MITIGATION = 12 PALMS TOTAL = 30 TOTAL PALMS REQUIRING MITIGATION =0 MITIGATION REQUIRED 12" @ 2:1 RATIO = 24" DBH MITIGATION 280" PRESERVED ONSITE = 560" MITIGATION CREDIT 24" - 560" = 536" DBH CREDIT REMAINING 31 PALM CREDIT REMAINING FEE REQUIREMENTS = N/A TREE MITIGATION CALCULATIONS EXISTING DITCH PROPOSED LIGHT POLE (BY OTHERS)FLORIDAREVISIONS DATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C15 LANDSCAPE PLAN.dwg 9/24/2020 1:12 PMGREGG REEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTS3200 NORTH KINGS HIGHWAY C16LANDSCAPE DETAILS9/24/2020Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE PLAN/SECTION ±18" POOR DRAINAGE CONDITION NOTE: 8.WATER TABLE. (DEPTH VARIES) 7.BACKFILL WITH 1/2" - 3/4" GRAVEL. 5.SLOPE BOTTOM TO DRAIN 4.12" CLEAN SAND, COMPACTED. ADJUST LAYER THICKNESS SO TOP OF ROOTBALL IS AT LEAST 1" ABOVE FINISHED GRADE. 6.±18"∅ AUGURED HOLE PENETRATE THROUGH OCCLUDING LAYER TO WATER TABLE OR TO A DEPTH OF 7' TO ASSURE PROPER PERCOLATION.±48"±36"FOR A PARKING ISLAND PLANTING SITUATION, CONTRACTOR TO BACKFILL ENTIRE LENGTH OF PLANTING AREA TO WITHIN 6" OF BACK OF CURB OR EDGE OF PAVEMENT. 2.BACKFILL WITH PREPARED PLANTING SOIL MIX AS SPECIFIED. 1.FINISH GRADE PALM PLANTING AND STAKING 10. 24"L (MIN.) 2X4 P.T. WOOD STAKES, NAIL TO SUPPORT POLES 11. PREPARED PLANTING SOIL AS SPECIFIED 3.FIVE (5) 18"L, 2X4 WOOD BATTENS. UNTREATED, #2 4.SECURE BATTENS WITH TWO (2) 3/4" CARBON STEEL BANDS TO HOLD BATTENS IN PLACE. NO NAILS SHALL BE DRIVEN INTO PALM. HEIGHT OF BATTENS SHALL BE LOCATED PROPORTIONATELY TO THE HEIGHT OF THE PALM FOR ADEQUATE BRACING. 9.FINISH GRADE 8.3" SPECIFIED MULCH 6.PROVIDE FLAGGING AT MIDPOINT AND BASE OF SUPPORTS. 5.THREE (3) 8'L 2X4 SUPPORTS. NAIL (DRILL AND NAIL IF NECESSARY) TO BATTENS AND 2" X 4" STAKES. PALMS SHALL BE PLUMB VERTICALLY UNLESS OTHERWISE NOTED. 1.MINIMUM OF NINE (9) GOOD PALM FRONDS; PRUNE AND TIE FRONDS WITH HEMP TWINE. SABAL PALMS TO BE SELECTIVELY "HURRICANE CUT", LEAVING ONLY NEWLY- EMERGING GROWTH. 2.5 LAYERS OF BURLAP TO PROTECT TRUNK. 3.FILTER CLOTH, MIRAFI 500X OR BETTER A.WASHINGTONIA PALMS SIMILAR W/ BOOTS INTACT. B.SEE PLANS AND SPECS. FOR PALMS W/ BOOTS TO REMAIN ON TRUNK. C.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER. D.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION - REFER TO POOR DRAINAGE CONDITION DETAIL. OA=OVERALL PALM HEIGHT (MEASURED TO TOP OF BUD) CT=CLEAR TRUNK (MEASURED TO BOTTOM OF LEAF SHEATHS) GW=GRAY WOOD (MEASURED TO TOP OF HARDENED TRUNK) NOTES: 1 5 3 4 2 6 7 8 9 10 11 1 3 2 5 6 4 8 7 OA CT GW 120° PLAN 120°120° PLAN 6 + H.P. 5 ROOTBALL SECTION LIMITS OF TREE/ SHRUB PIT 1. INSTALL CONTINUOUS MULCH BED ADJACENT TO PARKING SPACES AS SHOWN. MULCH SHALL BE MIN. 3" DEEP. NO POP-UP IRRIGATION HEADS SHALL BE LOCATED WITHIN 24" OF A PARKING SPACE ON ANY SIDE SECTION PARKING SPACE/CURB PLANTING 2'-0" 2. CURB OR PARKING LOT EDGE, BY OTHERS 12 MIN. CLEAR 36" (MIN) TO CENTER OF TRUNK CLEAR ZONE: 36" MIN. FROM BUILDING TO CENTER OF NEAREST SHRUB. NOTES SECTION PLANTINGS ADJACENT TO BUILDINGS * *STONE MULCH: 24" MIN. FROM BUILDING, INSTALL STONE MULCH. MULCH TYPE TO BE RUSTIC RIVER ROCK OR OWNER'S REPRESENTATIVE APPROVED EQUAL. STONE MULCH TO BE INSTALLED TO A DEPTH OF 4"-6" (MIN.) 24" (MIN) STONE MULCH TREE PLANTING 3X ROOTBALL DIAMETER C.SEE PRE-APPROVED STAKING METHODS, THIS SHEET NOTES: 5.FIND TOP-MOST ROOT ON ROOTBALL; POSITION ROOTBALL SO THIS TOP ROOT IS 1-2" ABOVE LANDSCAPE SOIL. (APPROX. 10% OF ROOTBALL SHALL BE ABOVE LANDSCAPE SOIL) 6.B & B OR CONTAINER (SEE SPECIFICATIONS FOR ROOT BALL REQUIREMENTS). 7.REMOVE ALL SYNTHETIC MATERIALS FROM ROOTBALL. 8.ROOTBALLS SHALL BE PLACED ON UNDISTURBED SOIL TO PREVENT SETTLING. A.CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. B.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER. 1. TRUNK 3.SHALLOW/ WIDE PLANT HOLE; TOP SHALL BE 3X THE SIZE OF ROOTBALL. 4.FINISHED GRADE - LANDSCAPE SOIL 5 4 1 3 2 6 7 8 *ALL TREES SHALL BE PLUMB VERTICALLY WITHIN A TOLERANCE OF THREE DEGREES, UNLESS OTHERWISE DIRECTED BY OWNER'S REPRESENTATIVE. PLAN/SECTION STAKING - UP TO 65 GAL. OR B&B TO 3-1/2" CAL. NOTE: 5.STAKES TO EXTEND INTO NATIVE SOIL BY 1-1/2 X THE ROOTBALL DEPTH MIN. 4.VERTICAL STAKES SHALL ABUT SIDE OF ROOTBALL 48" MIN.IF SPATIAL REQUIREMENTS PRECLUDE STAKING WITH THIS METHOD, SUBMIT ALTERNATE FOR LANDSCAPE ARCHITECT'S APPROVAL PRIOR TO INSTALLING PLANT. 2.HORIZONTAL 2X2 SCREWED TO 2X2 STAKE. ALL WOOD SHALL BE #2 UNTREATED. 1.FINISH GRADE 3X ROOTBALL .DIAMETER 3.3-1/2" DRYWALL SCREW, THREAD SIZE 12, SHARP POINT, FULL THREAD, BLACK PHOSPHATE FINISH 12 PLAN 5 ROOTBALL SECTION LIMITS OF PLANT PIT 3 2 4 NTS 8.SCARIFY ROOTBALL SIDES AND BOTTOM. PLAN 2.TOP 10% OF SHRUB AND GROUNDCOVER ROOTBALLS TO BE PLANTED ABOVE THE LANDSCAPE GRADE. DO NOT COVER EXPOSED 10% ON SIDES WITH SOIL. 3.PRUNE ALL LIKE SHRUBS WITHIN A PLANTED MASS TO ACHIEVE A UNIFORM MASS/HEIGHT. 4.3" MINIMUM MULCH AS SPECIFIED - DO NOT COVER ENTIRE SHRUB ROOTBALL OR CREATE 'WATER RINGS' ONLY COVER SIDES OF ROOTBALL WITH MULCH 5.EXCAVATE ENTIRE BED SPECIFIED FOR GROUNDCOVER BED. 6.FINISHED GRADE (SEE GRADING PLAN). 7.PREPARED PLANTING SOIL AS SPECIFIED. NOTE: WHEN GROUND- COVERS AND SHRUBS USED IN MASSES, ENTIRE BED TO BE AMENDED WITH PLANTING SOIL MIX AS SPECIFIED. SHRUB / GROUNDCOVER PLANTING MAINTAIN 12" DEAD ZONE AT BED EDGE (TYP) REFER TO PLANT SCHEDULE FOR SPACING BEST FACE OF SHRUB/ GROUNDCOVER TO FACE FRONT OF PLANTING BED. 'X' 3 564 2 8 7 X X SECTION *ALL SHRUBS AND GROUNDCOVERS SHALL BE PLUMB VERTICALLY, UNLESS OTHERWISE DIRECTED BY OWNER'S REPRESENTATIVE. 2X ROOTBALL DIAMETER 1.FIND POINT WHERE TOPMOST ROOT EMERGES FROM TRUNK WITHIN 2" OF SURFACE. CLEAR EXCESS SOIL IF NECESSARY. rootball 10% of BED EDGE 1 5 3 1 4 2 7 8 PLANTING ON A SLOPE SECTION A. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION. B.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER. 5.FIND TOP-MOST ROOT ON ROOTBALL; POSITION ROOTBALL SO THIS TOP ROOT IS 1-2" ABOVE LANDSCAPE SOIL. (APPROX. 10% OF ROOTBALL SHALL BE ABOVE LANDSCAPE SOIL) *ALL TREES SHALL BE PLUMB VERTICALLY WITHIN A TOLERANCE OF THREE DEGREES, UNLESS OTHERWISE DIRECTED BY OWNER'S REPRESENTATIVE. EXISTING GRADE (DASHED) 3X ROOTBALL DIAMETER rootball 10% of NOTES: 7.B & B OR CONTAINER REMOVE ALL SYNTHETIC MATERIALS FROM ROOTBALL. (SEE SPECIFICATIONS FOR OTHER ROOT BALL REQUIREMENTS) 8.ROOTBALLS SHALL BE PLACED ON UNDISTURBED SOIL TO PREVENT SETTLING. 1.TREES, PALMS, AND LARGE SHRUBS (15 GAL OR GREATER) SHALL BE PLANTED IN SIMILAR MANNER 2.3" MINIMUM OF MULCH AS SPECIFIED. WHERE TREES ARE PLACED IN SOD, MULCH RING FOR TREES COVER ROOTBALL SIDES AND EXTEND 18" BEYOND ON ALL SIDES. NO MULCH SHALL BE PLACED OVER TRUNK. 3.SHALLOW/ WIDE PLANT HOLE; TOP SHALL BE 3X THE SIZE OF ROOTBALL. 4.FINISHED GRADE - LANDSCAPE SOIL B.FINAL TREE STAKING DETAILS AND PLACEMENT TO BE APPROVED BY OWNER. C.ALTERNATE TREE ANCHORING SYSTEMS MAY BE SUBSTITUTED FOR WOOD STAKING SYSTEM UPON APPROVAL BY OWNER OR OWNER'S REPRESENTATIVE PRE-APPROVED SYSTEMS: *BROOKS TREE BRACING *ARBOR TIE TREE BRACING D.RUBBER HOSE/WIRE SYSTEMS ARE NOT ALLOWED. NOTES: 6.FINISHED GRADE (SEE GRADING PLAN) 5.2" x 4" x 3' (MIN), P.T. WOOD STAKES BURIED 3" BELOW FINISHED GRADE. SECTION LARGE TREE STAKING - 100 GAL + OR B&B 4" + PLAN 1.FIVE (5) LAYERS OF BURLAP TO PROTECT TRUNK 2.TWO STEEL BANDS TO SECURE BATTENS 3.FIVE 2 X 4 X 18"L WOOD BATTENS 4.THREE (3) 2" X 8' LODGE POLES. DRILL, USING GALVANIZED SCREWS, TO BATTENS AND 2" X 4" STAKES. NO SCREWS SHALL PENETRATE TREE. FLAG AT MIDPOINT AND AT BASE. 5 6 4 3 1 2 A.ALL TREES SHALL BE PLUMB VERTICALLY WITHIN A TOLERANCE OF THREE DEGREES, UNLESS OTHERWISE DIRECTED BY OWNER'S REPRESENTATIVE. 6.BERM SOIL SO THAT TOP OF BERM IS JUST BELOW THE TOP 10% OF THE TOP OF THE ROOTBALL. SLOPE DOWNHILL PORTION OF BERM AS REQUIRED TO MEET EXISTING GRADE.6 2.3" MINIMUM OF MULCH AS SPECIFIED. WHERE TREES ARE PLACED IN SOD, MULCH RING FOR TREES COVER ROOTBALL SIDES AND EXTEND 18" BEYOND ON ALL SIDES. NO MULCH SHALL BE PLACED OVER TRUNK. C.SEE PRE-APPROVED STAKING METHODS, THIS SHEET 7.TOP-MOST ROOT SHALL BE VISIBLE AT THE SURFACE OF THE ROOTBALL, SLIGHTLY ABOVE SURROUNDING GRADE. 1. CROWN ISLANDS @ 5:1 SLOPES (OR AS SPECIFIED ON THE LANDSCAPE PLANS). 2.CLEAR ZONE: 36" MIN. FROM BACK OF CURB TO CENTER OF NEAREST SHRUB. CLEAR ZONE SHALL CONTAIN 3" CONTINUOUS MULCH OR TURF, SEE PLANS. SEE DETAIL 'I' FOR PLANTER MEDIANS ADJACENT TO PARKING SPACES. 3. 1" MIN VERTICAL CLEARANCE, TOP OF CURB TO TOP OF MULCH. ·EXCAVATE CONTINUOUS 36" DEEP (FROM TOP OF CURB) FOR ENTIRE LENGTH AND WIDTH OF ISLAND & BACKFILL WITH APPROVED PLANTING MIX. ·PROTECT AND RETAIN ALL CURBS AND BASE. COMPACTED SUBGRADE TO REMAIN FOR STRUCTURAL SUPPORT OF CURB SYSTEM (TYP). ·ALL ISLANDS SHALL UTILIZE POOR DRAINAGE DETAIL WHEN PERCOLATION RATES ARE 2" PER HOUR OR LESS. PLANTER ISLAND NOTES SECTION PLANTED PARKING LOT ISLANDS / MEDIANS WIDTH VARIES - SEE PLANS 2 1 3 1:5 1:5 ±3'-0" TO CENTER OF NEAREST SHRUB 2'-0" 12 MIN. CLEAR ±3'-0" TO CENTER OF NEAREST SHRUB PARKING ISLAND, SIDE DETAIL PARKING ISLAND, NOSE-IN DETAIL CAR DOOR 120° 120°120° B. CONSTRUCTION AND INSTALLATION NOTES: A. MATERIALS ANTI-LIFT GROUND LOCK ZIPPER JOINING SYSTEM DOUBLE TOP EDGE ZIPPER JOINING SYSTEM .085" .085" 1/2" 1/4" 7/16" .085" .085" 2 1/4" .085"3/8" 24" DEEPROOT TREE ROOT BARRIERS SPECIFIED TREE ROOT BARRIERS ARE A MECHANICAL BARRIER AND ROOT DEFLECTOR TO PREVENT TREE ROOTS FROM DAMAGING HARD- SCAPES AND LANDSCAPES. ASSEMBLED IN 2' LONG MODULES TO CREATE VARYING SIZES OF CYLINDERS FOR SURROUNDING ROOT BALLS (SURROUND PLANTING STYLE) OR FOR LINEAR APPLICATIONS DIRECTLY BESIDE A HARDSCAPE ADJACENT TO ONE SIDE OF THE TREES (LINEAR PLANTING STYLE). 1.THE CONTRACTOR SHALL FURNISH AND INSTALL TREE ROOT BARRIERS AS SPECIFIED. THE TREE ROOT BARRIERS SHALL BE PRODUCT # UB 24-2 AS MANUFACTURED BY DEEP ROOT PARTNERS, L.P. 345 LORTON AVE. #103, BURLINGAME, CA (800-458-7668), OR APPROVED EQUAL. THE BARRIER SHALL BE BLACK, INJECTION MOLDED PANELS, OF 0.085" WALL THICKNESS IN MODULES 24" LONG BY 24" DEEP; MANUFACTURED WITH A MINIMUM 50% POST CONSUMER RECYCLED POLYPROPYLENE PLASTIC WITH ADDED ULTRAVIOLET INHIBITORS; RECYCLABLE. EACH PANEL SHALL HAVE: 1.THE CONTRACTOR SHALL INSTALL THE TREE ROOT BARRIERS WITH THE NUMBER OF PANELS AND IN THE MANNER SHOWN ON THE DRAWINGS. THE VERTICAL ROOT DEFLECTING RIBS SHALL BE FACING INWARDS TO THE ROOT BALL AND THE TOP OF THE DOUBLE EDGE SHALL BE 1/2" ABOVE GRADE. EACH OF THE REQUIRED NUMBER OF PANELS SHALL BE CONNECTED TO FORM A CIRCLE AROUND THE ROOT BALL OR WHERE SPECIFIED JOINED IN A LINEAR FASHION AND PLACED ALONG THE ADJACENT HARDSCAPE. ALL STREET TREES WITH TRUNKS CLOSER THAN 4 FT. TO PAVED SURFACES SHALL BE PLANTED WITH ROOT BARRIER BETWEEN THE ROOT BALL AND PAVING. PLANTINGS WITHIN TREE WELLS REQUIRE ROOT BARRIERS ALONG ALL SIDES OF THE TREE WELL. 2.EXCAVATION AND SOIL PREPARATION SHALL CONFORM TO THE DRAWINGS 3.THE TREE ROOT BARRIERS SHALL BE BACKFILLED ON THE OUTSIDE WITH 3/4" TO 1 1/2" GRAVEL OR CRUSHED ROCK AS SHOWN ON THE DRAWINGS. NO GRAVEL BACKFILL IS REQUIRED FOR A LINEAR PLANTING SECTION DOUBLE TOP EDGE FOR PREVENTION OF ROOT OVER GROWTH 90° ROOT DEFLECTING RIBS INTEGRAL PART OF PANEL PANEL 0.085" (2.16MM) THICK POLYPROPYLENE PATENTED MOLDED GROUND LOCKING ANTI-LIFT PADS (SEE DETAIL "B") ROUNDED EDGES FOR SAFETY AND STRENGTH SECTION SECTION PLAN/SECTION NTS NTS NTS NTS NTS NTS NTS NTS NTS 10% of rootball NTS TREE PLANTING AND STAKING SECTION NTS 1. PLACE RUBBER HOSE ON WIRE AT ALL POINTS OF CONTACT WITH TREE. 2.PLACE 3 GALVANIZED GUY WIRES (DOUBLE STRANDS), OF SUITABLE STRENGTH FOR TREE, SPACED EQUAL DISTANCE AROUND TREE ABOVE FIRST LATERAL BRANCH AND 6"-9" FROM TOP OF STAKE. 3. REMOVE BURLAP FROM TOP 1 3 OF ROOTBALL IF APPLICABLE. 4.3" MULCH (CYPRESS MULCH SHALL NOT BE UTILIZED). 5. 2"x4"x10' WOOD STAKE DRIVEN 3' BELOW GRADE. 6. PLANTING PIT DEPTH SHALL EQUAL DEPTH OF ROOT BALL PLUS 6" FOR SETTING LAYER OF COMPACTED BACKFILL. PLANTING PIT WIDTH SHALL BE TWICE THE DIAMETER OF THE ROOT BALL. 7. BACKFILL AROUND ROOT BALL AS SPECIFIED. 8. PLANT TOP OF ROOT BALL EVEN WITH OR SLIGHTLY HIGHER THAN FINISHED GRADE. 9. PLACE ROOT BALL AT BOTTOM OF THE PLANTING PIT ON 6" LAYER OF COMPACTED BACKFILL. 1 2 3 4 5 6 7 8 9 FLORIDAREVISIONSDATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C15 LANDSCAPE PLAN.dwg 9/24/2020 1:12 PMGREGG REEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTS3200 NORTH KINGS HIGHWAY C17LANDSCAPE SPECIFICATIONS9/24/2020Know what's below. before you dig.Call R 72 HOURS BEFORE DIGGING CALL TOLL FREE A.SCOPE OF WORK 1. THE WORK CONSISTS OF: FURNISHING ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, TRANSPORTATION, AND ANY OTHER APPURTENANCES NECESSARY FOR THE COMPLETION OF THIS PROJECT AS SHOWN ON THE DRAWINGS, AS INCLUDED IN THE PLANT LIST, AND AS HEREIN SPECIFIED. 2. WORK SHALL INCLUDE MAINTENANCE AND WATERING OF ALL CONTRACT PLANTING AREAS UNTIL CERTIFICATION OF ACCEPTABILITY BY THE OWNER. B.PROTECTION OF EXISTING STRUCTURES ALL EXISTING BUILDINGS, WALKS, WALLS, PAVING, PIPING, OTHER SITE CONSTRUCTION ITEMS, AND PLANTING ALREADY COMPLETED OR ESTABLISHED SHALL BE PROTECTED FROM DAMAGE BY THE CONTRACTOR UNLESS OTHERWISE SPECIFIED. ALL DAMAGE RESULTING FROM NEGLIGENCE SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER, AT NO COST TO THE OWNER. C.PROTECTION OF EXISTING PLANT MATERIALS OUTSIDE LIMIT OF WORK THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UNAUTHORIZED CUTTING OR DAMAGE TO TREES AND SHRUBS EXISTING OR OTHERWISE, CAUSED BY CARELESS EQUIPMENT OPERATION, MATERIAL STOCKPILING, ETC. THIS SHALL INCLUDE COMPACTION BY DRIVING OR PARKING INSIDE THE DRIP-LINE AND SPILLING OIL, GASOLINE, OR OTHER DELETERIOUS MATERIALS WITHIN THE DRIP-LINE. NO MATERIALS SHALL BE BURNED WHERE HEAT WILL DAMAGE ANY PLANT. EXISTING TREES KILLED OR DAMAGED SO THAT THEY ARE MISSHAPEN AND/ OR UNSIGHTLY SHALL BE REPLACED AT THE COST TO THE CONTRACTOR OF ONE HUNDRED DOLLARS ($100) PER CALIPER INCH ON AN ESCALATING SCALE WHICH ADDS AN ADDITIONAL TWENTY (20) PERCENT PER INCH OVER FOUR (4) INCHES CALIPER AS FIXED AND AGREED LIQUIDATED DAMAGES. CALIPER SHALL BE MEASURED SIX (6) INCHES ABOVE GROUND LEVEL FOR TREES UP TO AND INCLUDING FOUR (4) INCHES IN CALIPER AND TWELVE (12) INCHES ABOVE GROUND LEVEL FOR TREES OVER FOUR (4) INCHES IN CALIPER. D.MATERIALS 1. GENERAL MATERIAL SAMPLES LISTED BELOW SHALL BE SUBMITTED FOR APPROVAL, ON THE SITE OR AS OTHERWISE DETERMINED BY THE OWNER. UPON SAMPLES' APPROVAL, DELIVERY OF MATERIALS MAY COMMENCE. MATERIAL SAMPLE SIZE MULCH ONE (1) CUBIC FOOT TOPSOIL MIX ONE (1) CUBIC FOOT PLANTS ONE (1) OF EACH VARIETY (OR TAGGED IN NURSERY) 2. PLANT MATERIALS a. PLANT SPECIES AND SIZE SHALL CONFORM TO THOSE INDICATED ON THE DRAWINGS. NOMENCLATURE SHALL CONFORM TO STANDARDIZED PLANT NAMES, 1942 EDITION. ALL NURSERY STOCK SHALL BE IN ACCORDANCE WITH GRADES AND STANDARDS FOR NURSERY PLANTS, LATEST EDITION, PUBLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. ALL PLANTS SHALL BE FLORIDA GRADE NO. 1 OR BETTER AS DETERMINED BY THE FLORIDA DIVISION OF PLANT INDUSTRY. ALL PLANTS SHALL BE HEALTHY, VIGOROUS, SOUND, WELL-BRANCHED, AND FREE OF DISEASE AND INSECTS, INSECT EGGS AND LARVAE AND SHALL HAVE ADEQUATE ROOT SYSTEMS. TREES FOR PLANTING IN ROWS SHALL BE UNIFORM IN SIZE AND SHAPE. ALL MATERIALS SHALL BE SUBJECT TO APPROVAL BY THE OWNER. WHERE ANY REQUIREMENTS ARE OMITTED FROM THE PLANT LIST, THE PLANTS FURNISHED SHALL BE NORMAL FOR THE VARIETY. PLANTS SHALL BE PRUNED PRIOR TO DELIVERY ONLY WITH APPROVAL FROM OWNER OR OWNER'S REPRESENTATIVE. NO SUBSTITUTIONS SHALL BE MADE WITHOUT WRITTEN PERMISSION FROM THE OWNER'S REPRESENTATIVE. b. MEASUREMENTS: THE HEIGHT AND/OR WIDTH OF TREES SHALL BE MEASURED FROM THE GROUND OR ACROSS THE NORMAL SPREAD OF BRANCHES WITH THE PLANTS IN THEIR NORMAL POSITION. THIS MEASUREMENT SHALL NOT INCLUDE THE IMMEDIATE TERMINAL GROWTH. PLANTS LARGER IN SIZE THAN THOSE SPECIFIED IN THE PLANT LIST MAY BE USED IF APPROVED BY THE OWNER. IF THE USE OF LARGER PLANTS IS APPROVED, THE BALL OF EARTH OR SPREAD OF ROOTS SHALL BE INCREASED IN PROPORTION TO THE SIZE OF THE PLANT. c. INSPECTION: PLANTS SHALL BE SUBJECT TO INSPECTION AND APPROVAL AT THE PLACE OF GROWTH, OR UPON DELIVERY TO THE SITE, AS DETERMINED BY THE OWNER, FOR QUALITY, SIZE, AND VARIETY; SUCH APPROVAL SHALL NOT IMPAIR THE RIGHT OF INSPECTION AND REJECTION AT THE SITE DURING PROGRESS OF THE WORK OR AFTER COMPLETION FOR SIZE AND CONDITION OF ROOT BALLS OR ROOTS, LATENT DEFECTS OR INJURIES. REJECTED PLANTS SHALL BE REMOVED IMMEDIATELY FROM THE SITE. NOTICE REQUESTING INSPECTION SHALL BE SUBMITTED IN WRITING BY THE CONTRACTOR AT LEAST ONE (1) WEEK PRIOR TO ANTICIPATED DATE. E.SOIL MIXTURE (PLANTING MEDIUM, PLANTING MIX, TOPSOIL MIX) 1. SOIL MIXTURE (PLANTING MEDIUM FOR PLANT PITS) SHALL CONSIST OF TWO PARTS OF TOPSOIL AND ONE PART SAND, AS DESCRIBED BELOW. 2.TOPSOIL FOR USE IN PREPARING SOIL MIXTURE FOR BACKFILLING PLANT PITS SHALL BE FERTILE, FRIABLE, AND OF A LOAMY CHARACTER: REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH WEEDS AND OTHER LITTER: FREE OF ROOTS, STUMPS, STONES LARGER THAN 2" IN ANY DIRECTION, AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH. IT SHALL CONTAIN THREE (3) TO FIVE (5) PERCENT DECOMPOSED ORGANIC MATTER AND A PH BETWEEN 5.5 AND 7.0 - SUBMIT SAMPLE AND PH TESTING RESULTS FOR APPROVAL. 3.SAND SHALL BE COARSE, CLEAN, WELL-DRAINING, NATIVE SAND. CONTRACTOR SHALL SUBMIT RESULTS OF SOIL TESTS FOR TOPSOIL AND SAND PROPOSED FOR USE UNDER THIS CONTRACT FOR APPROVAL BY THE OWNER. 4. TREES SHALL BE PLANTED IN THE EXISTING NATIVE SOIL ON SITE, UNLESS DETERMINED TO BE UNSUITABLE - AT WHICH POINT THE CONTRACTOR SHALL CONTACT ENGINEER TO DISCUSS ALTERNATE RECOMMENDATION PRIOR TO PLANTING. 5. CONTRACTOR TO SUBMIT SAMPLES OF SOIL MIXTURE FOR OWNER'S REPRESENTATIVE APPROVAL PRIOR TO PLANT INSTALLATION OPERATIONS COMMENCE. F.WATER WATER NECESSARY FOR PLANTING AND MAINTENANCE SHALL BE OF SATISFACTORY QUALITY TO SUSTAIN AN ADEQUATE PLANT GROWTH AND SHALL NOT CONTAIN HARMFUL, NATURAL OR MAN-MADE ELEMENTS DETRIMENTAL TO PLANTS. WATER MEETING THE ABOVE STANDARD SHALL BE OBTAINED ON THE SITE FROM THE OWNER, IF AVAILABLE, AND THE CONTRACTOR SHALL BE RESPONSIBLE TO MAKE ARRANGEMENTS FOR ITS USE BY HIS TANKS, HOSES, SPRINKLERS, ETC.. IF SUCH WATER IS NOT AVAILABLE AT THE SITE, THE CONTRACTOR SHALL PROVIDE SATISFACTORY WATER FROM SOURCES OFF THE SITE AT NO ADDITIONAL COST TO THE OWNER. *WATERING/IRRIGATION RESTRICTIONS MAY APPLY - REFER TO PROPERTY'S JURISDICTIONAL AUTHORITY . G. FERTILIZER CONTRACTOR SHALL PROVIDE FERTILIZER APPLICATION SCHEDULE TO OWNER, AS APPLICABLE TO SOIL TYPE, PLANT INSTALLATION TYPE, AND SITE'S PROPOSED USE. SUGGESTED FERTILIZER TYPES SHALL BE ORGANIC OR OTHERWISE NATURALLY-DERIVED. APPLICATION IS TO BE IN ACCORDANCE WITH FLORIDA GREEN INDUSTRIES BEST MANAGEMENT PRACTICES. *FERTILIZER RESTRICTIONS MAY APPLY - REFER TO PROPERTY'S JURISDICTIONAL AUTHORITY. H.MULCH MULCH MATERIAL SHALL BE MOISTENED AT THE TIME OF APPLICATION TO PREVENT WIND DISPLACEMENT, AND APPLIED AT A MINIMUM DEPTH OF 3 INCHES. CLEAR MULCH FROM EACH PLANT'S CROWN (BASE). SEE PLANT LIST FOR TYPE OF MATERIAL ("FLORIMULCH," EUCALYPTUS MULCH, OR PINE STRAW) AND GRADE. I.DIGGING AND HANDLING 1. PROTECT ROOTS OR ROOT BALLS OF PLANTS AT ALL TIMES FROM SUN, DRYING WINDS, WATER AND FREEZING, AS NECESSARY UNTIL PLANTING. PLANT MATERIALS SHALL BE ADEQUATELY PACKED TO PREVENT DAMAGE DURING TRANSIT. TREES TRANSPORTED MORE THAN TEN (10) MILES OR WHICH ARE NOT PLANTED WITHIN THREE (3) DAYS OF DELIVERY TO SITE SHALL BE SPRAYED WITH AN ANTI-TRANSPIRANT PRODUCT ("WILTPRUF" OR EQUAL) TO MINIMIZE TRANSPIRATIONAL WATER LOSS. 2. BALLED AND BURLAPPED PLANTS (B&B) SHALL BE DUG WITH FIRM, NATURAL BALLS OF SOIL OF SUFFICIENT SIZE TO ENCOMPASS THE FIBROUS AND FEEDING ROOTS OF THE PLANTS. NO PLANTS MOVED WITH A ROOT BALL SHALL BE PLANTED IF THE BALL IS CRACKED OR BROKEN. PLANTS BALLED AND BURLAPPED OR CONTAINER GROWN SHALL NOT BE HANDLED BY STEMS. 3. PLANTS MARKED "BR" IN THE PLANT LIST SHALL BE DUG WITH BARE ROOTS, COMPLYING WITH FLORIDA GRADES AND STANDARDS FOR NURSERY PLANTS, CURRENT EDITION. CARE SHALL BE EXERCISED THAT THE ROOTS DO NOT DRY OUT DURING TRANSPORTATION AND PRIOR TO PLANTING. 4. PROTECTION OF PALMS (IF APPLICABLE): ONLY A MINIMUM OF FRONDS SHALL BE REMOVED FROM THE CROWN OF THE PALM TREES TO FACILITATE MOVING AND HANDLING. CLEAR TRUNK (CT) SHALL BE AS SPECIFIED AFTER THE MINIMUM OF FRONDS HAVE BEEN REMOVED. ALL PALMS SHALL BE BRACED PER PALM PLANTING DETAIL. 5. EXCAVATION OF TREE PITS SHALL BE PERFORMED USING EXTREME CARE TO AVOID DAMAGE TO SURFACE AND SUBSURFACE ELEMENTS SUCH AS UTILITIES OR HARDSCAPE ELEMENTS, FOOTERS AND PREPARED SUB- BASES. J. CONTAINER GROWN STOCK 1. ALL CONTAINER GROWN MATERIAL SHALL BE HEALTHY, VIGOROUS, WELL-ROOTED PLANTS ESTABLISHED IN THE CONTAINER IN WHICH THEY ARE SOLD. THE PLANTS SHALL HAVE TOPS WHICH ARE OF GOOD QUALITY AND ARE IN A HEALTHY GROWING CONDITION, FLORIDA #1 OR BETTER. 2. AN ESTABLISHED CONTAINER GROWN PLANT SHALL BE TRANSPLANTED INTO A CONTAINER AND GROWN IN THAT CONTAINER SUFFICIENTLY LONG FOR THE NEW FIBROUS ROOTS TO HAVE DEVELOPED SO THAT THE ROOT MASS WILL RETAIN ITS SHAPE AND HOLD TOGETHER WHEN REMOVED FROM THE CONTAINER. CONTAINER GROWN STOCK SHALL NOT BE HANDLED BY THEIR STEMS. 3. PLANT ROOTS BOUND IN CONTAINERS ARE NOT ACCEPTABLE. 4. SUBSTITUTION OF NON-CONTAINER GROWN MATERIAL FOR MATERIAL EXPLICITLY SPECIFIED TO BE CONTAINER GROWN WILL NOT BE PERMITTED WITHOUT WRITTEN APPROVAL IS OBTAINED FROM THE OWNER OR OWNER'S REPRESENTATIVE. K. COLLECTED STOCK WHEN THE USE OF COLLECTED STOCK IS PERMITTED AS INDICATED BY THE OWNER OR OWNER'S REPRESENTATIVE, THE MINIMUM SIZES OF ROOTBALLS SHALL BE EQUAL TO THAT SPECIFIED FOR THE NEXT LARGER SIZE OF NURSERY GROWN STOCK OF THE SAME VARIETY. L. NATIVE STOCK PLANTS COLLECTED FROM WILD OR NATIVE STANDS SHALL BE CONSIDERED NURSERY GROWN WHEN THEY HAVE BEEN SUCCESSFULLY RE-ESTABLISHED IN A NURSERY ROW AND GROWN UNDER REGULAR NURSERY CULTURAL PRACTICES FOR A MINIMUM OF TWO (2) GROWING SEASONS AND HAVE ATTAINED ADEQUATE ROOT AND TOP GROWTH TO INDICATE FULL RECOVERY FROM TRANSPLANTING INTO THE NURSERY ROW. M. MATERIALS LIST QUANTITIES NECESSARY TO COMPLETE THE WORK ON THE DRAWINGS SHALL BE FURNISHED BY THE CONTRACTOR. QUANTITY ESTIMATES HAVE BEEN MADE CAREFULLY, BUT THE ENGINEER OR OWNER ASSUMES NO LIABILITY FOR OMISSIONS OR ERRORS. SHOULD A DISCREPANCY OCCUR BETWEEN THE PLANS AND THE PLANT LIST QUANTITY, THE ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION PRIOR TO BIDDING OR INSTALLATION. ALL DIMENSIONS AND/OR SIZES SPECIFIED SHALL BE THE MINIMUM ACCEPTABLE SIZE N.FINE GRADING 1. FINE GRADING UNDER THIS CONTRACT SHALL CONSIST OF FINAL FINISHED GRADING OF LAWN AND PLANTING AREAS THAT HAVE BEEN ROUGH GRADED BY OTHERS. BERMING AS SHOWN ON THE DRAWINGS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, UNLESS OTHERWISE NOTED. 2. THE CONTRACTOR SHALL FINE GRADE THE LAWN AND PLANTING AREAS TO BRING THE ROUGH GRADE UP TO FINAL FINISHED GRADE ALLOWING FOR THICKNESS OF SOD AND/OR MULCH DEPTH. THIS CONTRACTOR SHALL FINE GRADE BY HAND AND/OR WITH ALL EQUIPMENT NECESSARY INCLUDING A GRADING TRACTOR WITH FRONT-END LOADER FOR TRANSPORTING SOIL WITHIN THE SITE. 3. ALL PLANTING AREAS SHALL BE GRADED AND MAINTAINED FOR POSITIVE DRAINAGE TO SURFACE/SUBSURFACE STORM DRAIN SYSTEMS. AREAS ADJACENT TO BUILDINGS SHALL SLOPE AWAY FROM THE BUILDINGS. REFER TO CIVIL ENGINEER'S PLANS FOR FINAL GRADES. O.PLANTING PROCEDURES 1. CLEANING UP BEFORE COMMENCING WORK: THE CONTRACTOR SHALL CLEAN WORK AND SURROUNDING AREAS OF ALL RUBBISH OR OBJECTIONABLE MATTER. ALL MORTAR, CEMENT, AND TOXIC MATERIAL SHALL BE REMOVED FROM THE SURFACE OF ALL PLANT BEDS. THESE MATERIALS SHALL NOT BE MIXED WITH THE SOIL. SHOULD THE CONTRACTOR FIND SUCH SOIL CONDITIONS BENEATH THE SOIL WHICH WILL IN ANY WAY ADVERSELY AFFECT THE PLANT GROWTH, HE SHALL IMMEDIATELY CALL IT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. FAILURE TO DO SO BEFORE PLANTING SHALL MAKE THE CORRECTIVE MEASURES THE RESPONSIBILITY OF THE CONTRACTOR. 2. VERIFY LOCATIONS OF ALL UTILITIES, CONDUITS, SUPPLY LINES AND CABLES, INCLUDING BUT NOT LIMITED TO: ELECTRIC, GAS (LINES AND TANKS), WATER, SANITARY SEWER, STORMWATER SYSTEMS, CABLE, AND TELEPHONE. PROPERLY MAINTAIN AND PROTECT EXISTING UTILITIES. CALL NATIONAL ONE CALL - 811 - TO LOCATE UTILITIES. 3. SUBGRADE EXCAVATION: CONTRACTOR IS RESPONSIBLE TO REMOVE ALL EXISTING AND IMPORTED LIMEROCK AND LIMEROCK SUB-BASE FROM ALL LANDSCAPE PLANTING AREAS TO A MINIMUM DEPTH OF 36". CONTRACTOR IS RESPONSIBLE TO BACKFILL THESE PLANTING AREAS TO ROUGH FINISHED GRADE WITH CLEAN TOPSOIL FROM AN ON-SITE SOURCE OR AN IMPORTED SOURCE. IF LIMEROCK OR OTHER ADVERSE CONDITIONS OCCUR IN PLANTED AREAS AFTER 36" DEEP EXCAVATION BY THE CONTRACTOR, AND POSITIVE DRAINAGE CAN NOT BE ACHIEVED, CONTRACTOR SHALL UTILIZE PLANTING DETAIL THAT ADDRESSES POOR DRAINAGE. 4. FURNISH NURSERY'S CERTIFICATE OF COMPLIANCE WITH ALL REQUIREMENTS AS HEREIN SPECIFIED AND REQUIRED. INSPECT AND SELECT PLANT MATERIALS BEFORE PLANTS ARE DUG AT NURSERY OR GROWING SITE. 5. GENERAL: COMPLY WITH APPLICABLE FEDERAL, STATE, COUNTY, AND LOCAL REGULATIONS GOVERNING LANDSCAPE MATERIALS AND WORK. CONFORM TO ACCEPTED HORTICULTURAL PRACTICES AS USED IN THE TRADE. UPON ARRIVAL AT THE SITE , PLANTS SHALL BE THOROUGHLY WATERED AND PROPERLY MAINTAINED UNTIL PLANTED. PLANTS STORED ON-SITE SHALL NOT REMAIN UNPLANTED FOR A PERIOD EXCEEDING TWENTY-FOUR (24) HOURS. AT ALL TIMES WORKMANLIKE METHODS CUSTOMARY IN GOOD HORTICULTURAL PRACTICES SHALL BE EXERCISED. 6. THE WORK SHALL BE COORDINATED WITH OTHER TRADES TO PREVENT CONFLICTS. COORDINATE PLANTING WITH IRRIGATION WORK TO ASSURE AVAILABILITY OF WATER AND PROPER LOCATION OF IRRIGATION APPURTENANCES AND PLANTS. 7. ALL PLANTING PITS SHALL BE EXCAVATED TO SIZE AND DEPTH IN ACCORDANCE WITH THE USA STANDARD FOR NURSERY STOCK 260.1, UNLESS SHOWN OTHERWISE ON THE DRAWINGS, AND BACKFILLED WITH THE PREPARED PLANTING SOIL MIXTURE AS SPECIFIED IN SECTION E. TEST ALL TREE PITS WITH WATER BEFORE PLANTING TO ASSURE PROPER DRAINAGE PERCOLATION IS AVAILABLE. NO ALLOWANCE WILL BE MADE FOR LOST PLANTS DUE TO IMPROPER DRAINAGE. IF POOR DRAINAGE EXISTS, UTILIZE "POOR DRAINAGE CONDITION" PLANTING DETAIL. TREES SHALL BE SET PLUMB AND HELD IN POSITION UNTIL THE PLANTING MIXTURE HAS BEEN FLUSHED INTO PLACE WITH A SLOW, FULL HOSE STREAM. ALL PLANTING SHALL BE PERFORMED BY PERSONNEL FAMILIAR WITH PLANTING PROCEDURES AND UNDER THE SUPERVISION OF A QUALIFIED LANDSCAPE FOREMAN. PROPER "JETTING IN" SHALL BE ASSURED TO ELIMINATE AIR POCKETS AROUND THE ROOTS. "JET STICK" OR EQUAL IS RECOMMENDED 8. TAKE ALL NECESSARY PRECAUTIONS TO AVOID DAMAGE TO BUILDINGS AND BUILDING STRUCTURES WHILE INSTALLING TREES. 9. SOIL MIXTURE SHALL BE AS SPECIFIED IN SECTION E OF THESE SPECIFICATIONS. 10.TREES AND SHRUBS SHALL BE SET STRAIGHT AT AN ELEVATION THAT, AFTER SETTLEMENT, THE PLANT CROWN WILL STAND ONE (1) TO TWO (2) INCHES ABOVE GRADE. EACH PLANT SHALL BE SET IN THE CENTER OF THE PIT. PLANTING SOIL MIXTURE SHALL BE BACKFILLED, THOROUGHLY TAMPED AROUND THE BALL, AND SETTLED BY WATER (AFTER TAMPING). 11.AMEND PINE AND OAK PLANT PITS WITH ECTOMYCORRHIZAL SOIL APPLICATION PER MANUFACTURER'S RECOMMENDATION. ALL OTHER PLANT PITS SHALL BE AMENDED WITH ENDOMYCORRHIZAL SOIL APPLICATION PER MANUFACTURER'S RECOMMENDATION. PROVIDE PRODUCT INFORMATION SUBMITTAL PRIOR TO INOCULATION. 12.FILL HOLE WITH SOIL MIXTURE, MAKING CERTAIN ALL SOIL IS SATURATED. TO DO THIS, FILL HOLE WITH WATER AND ALLOW TO SOAK MINIMUM TWENTY (20) MINUTES, STIRRING IF NECESSARY TO GET SOIL THOROUGHLY WET. PACK LIGHTLY WITH FEET. ADD MORE WET SOIL MIXTURE. DO NOT COVER TOP OF BALL WITH SOIL MIXTURE, ONLY WITH MULCH. ALL BURLAP, ROPE, WIRES, BASKETS, ETC.., SHALL BE REMOVED FROM THE SIDES AND TOPS OF BALLS, BUT NO BURLAP SHALL BE PULLED FROM UNDERNEATH. 13.PRUNING: TREES SHALL BE PRUNED, AT THE DIRECTION OF THE OWNER OR OWNER'S REPRESENTATIVE, TO PRESERVE THE NATURAL CHARACTER OF THE PLANT. ALL SOFT WOOD OR SUCKER GROWTH AND ALL BROKEN OR BADLY DAMAGED BRANCHES SHALL BE REMOVED WITH A CLEAN CUT. ALL PRUNING TO BE PERFORMED BY LICENSED ARBORIST, IN ACCORDANCE WITH ANSI A-300. 14.SHRUBS AND GROUND COVER PLANTS SHALL BE EVENLY SPACED IN ACCORDANCE WITH THE DRAWINGS AND AS INDICATED ON THE PLANT LIST. CULTIVATE ALL PLANTING AREAS TO A MINIMUM DEPTH OF 6", REMOVE AND DISPOSE ALL DEBRIS. MIX TOP 4" THE PLANTING SOIL MIXTURE AS SPECIFIED IN SECTION E. THOROUGHLY WATER ALL PLANTS AFTER INSTALLATION. 15.TREE GUYING AND BRACING SHALL BE INSTALLED BY THE CONTRACTOR IN ACCORDANCE WITH THE PLANS TO INSURE STABILITY AND MAINTAIN TREES IN AN UPRIGHT POSITION. IF THE CONTRACTOR AND OWNER DECIDE TO WAIVE THE TREE GUYING AND BRACING, THE OWNER SHALL NOTIFY THE ENGINEER IN WRITING AND AGREE TO INDEMNIFY AND HOLD HARMLESS THE ENGINEER IN THE EVENT UNSUPPORTED TREES PLANTED UNDER THIS CONTRACT FALL AND DAMAGE PERSON OR PROPERTY. 16.MULCHING: PROVIDE A THREE INCH (MINIMUM) LAYER OF SPECIFIED MULCH OVER THE ENTIRE AREA OF EACH SHRUB BED, GROUND COVER, VINE BED, AND TREE PIT PLANTED UNDER THIS CONTRACT. 17.HERBICIDE WEED CONTROL: ALL PLANT BEDS SHALL BE KEPT FREE OF NOXIOUS WEEDS UNTIL FINAL ACCEPTANCE OF WORK. IF DIRECTED BY THE OWNER, "ROUND-UP" SHALL BE APPLIED FOR WEED CONTROL BY QUALIFIED PERSONNEL TO ALL PLANTING AREAS IN SPOT APPLICATIONS PER MANUFACTURER'S PRECAUTIONS AND SPECIFICATIONS. PRIOR TO FINAL INSPECTION, TREAT ALL PLANTING BEDS WITH AN APPROVED PRE-EMERGENT HERBICIDE AT AN APPLICATION RATE RECOMMENDED BY THE MANUFACTURER. (AS ALLOWED BY JURISDICTIONAL AUTHORITY). P. LAWN SODDING 1. THE WORK CONSISTS OF LAWN BED PREPARATION, SOIL PREPARATION, AND SODDING COMPLETE, IN STRICT ACCORDANCE WITH THE SPECIFICATIONS AND THE APPLICABLE DRAWINGS TO PRODUCE A TURF GRASS LAWN ACCEPTABLE TO THE OWNER. 2. LAWN BED PREPARATION: ALL AREAS THAT ARE TO BE SODDED SHALL BE CLEARED OF ANY ROUGH GRASS, WEEDS, AND DEBRIS, AND THE GROUND BROUGHT TO AN EVEN GRADE. THE ENTIRE SURFACE SHALL BE ROLLED WITH A ROLLER WEIGHING NOT MORE THAN ONE-HUNDRED (100) POUNDS PER FOOT OF WIDTH. DURING THE ROLLING, ALL DEPRESSIONS CAUSED BY SETTLEMENT SHALL BE FILLED WITH ADDITIONAL SOIL, AND THE SURFACE SHALL BE REGRADED AND ROLLED UNTIL PRESENTING A SMOOTH AND EVEN FINISH TO THE REQUIRED GRADE. 3. SOIL PREPARATION: PREPARE LOOSE BED FOUR (4) INCHES DEEP. HAND RAKE UNTIL ALL BUMPS AND DEPRESSIONS ARE REMOVED. WET PREPARED AREA THOROUGHLY. 4. SODDING a. THE CONTRACTOR SHALL SOD ALL AREAS THAT ARE NOT PAVED OR PLANTED AS DESIGNATED ON THE DRAWINGS WITHIN THE CONTRACT LIMITS, UNLESS SPECIFICALLY NOTED OTHERWISE. b. THE SOD SHALL BE CERTIFIED TO MEET FLORIDA STATE PLANT BOARD SPECIFICATIONS, ABSOLUTELY TRUE TO VARIETY TYPE, AND FREE FROM WEEDS, FUNGI, INSECTS AND DISEASES OF ANY KIND. c. SOD PANELS SHALL BE LAID TIGHTLY TOGETHER SO AS TO MAKE A SOLID SODDED LAWN AREA. SOD SHALL BE LAID UNIFORMLY AGAINST THE EDGES OF ALL CURBS AND OTHER HARDSCAPE ELEMENTS, PAVED AND PLANTED AREAS. ADJACENT TO BUILDINGS, A 24 INCH STONE MULCH STRIP SHALL BE PROVIDED - REFER TO DETAILS. IMMEDIATELY FOLLOWING SOD LAYING, THE LAWN AREAS SHALL BE ROLLED WITH A LAWN ROLLER CUSTOMARILY USED FOR SUCH PURPOSES, AND THEN THOROUGHLY IRRIGATED. IF, IN THE OPINION OF THE OWNER, TOP-DRESSING IS NECESSARY AFTER ROLLING TO FILL THE VOIDS BETWEEN THE SOD PANELS AND TO EVEN OUT INCONSISTENCIES IN THE SOD, CLEAN SAND, AS APPROVED BY THE OWNER'S REPRESENTATIVE, SHALL BE UNIFORMLY SPREAD OVER THE ENTIRE SURFACE OF THE SOD AND THOROUGHLY WATERED IN. FERTILIZE INSTALLED SOD AS ALLOWED BY PROPERTY'S JURISDICTIONAL AUTHORITY. 5. DURING DELIVERY, PRIOR TO, AND DURING THE PLANTING OF THE LAWN AREAS, THE SOD PANELS SHALL AT ALL TIMES BE PROTECTED FROM EXCESSIVE DRYING AND UNNECESSARY EXPOSURE OF THE ROOTS TO THE SUN. ALL SOD SHALL BE STACKED SO AS NOT TO BE DAMAGED BY SWEATING OR EXCESSIVE HEAT AND MOISTURE. 6. LAWN MAINTENANCE: a. WITHIN THE CONTRACT LIMITS, THE CONTRACTOR SHALL PRODUCE A DENSE, WELL ESTABLISHED LAWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND RE-SODDING OF ALL ERODED, SUNKEN OR BARE SPOTS (LARGER THAN 12"X12") UNTIL CERTIFICATION OF ACCEPTABILITY BY THE OWNER'S REPRESENTATIVE. REPAIRED SODDING SHALL BE ACCOMPLISHED AS IN THE ORIGINAL WORK (INCLUDING RE-GRADING IF NECESSARY). b. CONTRACTOR RESPONSIBLE FOR ESTABLISHING AND MAINTAINING SOD/LAWN UNTIL ACCEPTANCE BY THE OWNER'S REPRESENTATIVE. PRIOR TO AND UPON ACCEPTANCE, CONTRACTOR TO PROVIDE WATERING/IRRIGATION SCHEDULE TO OWNER. OBSERVE ALL APPLICABLE WATERING RESTRICTIONS AS SET FORTH BY THE PROPERTY'S JURISDICTIONAL AUTHORITY. Q. CLEANUP UPON COMPLETION OF ALL PLANTING WORK AND BEFORE FINAL ACCEPTANCE, THE CONTRACTOR SHALL REMOVE ALL MATERIAL, EQUIPMENT, AND DEBRIS RESULTING FROM HIS WORK. ALL PAVED AREAS SHALL BE BROOM-CLEANED AND THE SITE LEFT IN A NEAT AND ACCEPTABLE CONDITION AS APPROVED BY THE OWNER'S AUTHORIZED REPRESENTATIVE. R.PLANT MATERIAL MAINTENANCE ALL PLANTS AND PLANTING INCLUDED UNDER THIS CONTRACT SHALL BE MAINTAINED BY WATERING, CULTIVATING, SPRAYING, AND ALL OTHER OPERATIONS (SUCH AS RE-STAKING OR REPAIRING GUY SUPPORTS) NECESSARY TO INSURE A HEALTHY PLANT CONDITION BY THE CONTRACTOR UNTIL CERTIFICATION OF ACCEPTABILITY BY THE OWNER'S REPRESENTATIVE. MAINTENANCE AFTER THE CERTIFICATION OF ACCEPTABILITY SHALL BE IN ACCORDANCE WITH THE SPECIFICATIONS IN THIS SECTION. CONTRACTORS ARE REQUESTED TO PROVIDE A BID ESTIMATE TO COVER LANDSCAPE AND IRRIGATION MAINTENANCE FOR A PERIOD OF 90 CALENDAR DAYS COMMENCING AFTER ACCEPTANCE. S.MAINTENANCE (ALTERNATE BID ITEM) CONTRACTORS ARE REQUESTED TO PROVIDE A BID ESTIMATE FOR MAINTENANCE FOLLOWING THE INITIAL 90-DAY MAINTENANCE PERIOD ON A COST-PER-MONTH BASIS. T.FINAL INSPECTION AND ACCEPTANCE OF WORK FINAL INSPECTION AT THE END OF THE WARRANTY PERIOD SHALL BE ON PLANTING, CONSTRUCTION AND ALL OTHER INCIDENTAL WORK PERTAINING TO THIS CONTRACT. ANY REPLACEMENT AT THIS TIME SHALL BE SUBJECT TO THE SAME ONE (1) YEAR WARRANTY (OR AS SPECIFIED BY THE ENGINEER OR OWNER IN WRITING) BEGINNING WITH THE TIME OF REPLACEMENT AND ENDING WITH THE SAME INSPECTION AND ACCEPTANCE HEREIN DESCRIBED. U.WARRANTY 1. THE LIFE AND SATISFACTORY CONDITION OF ALL 7 GALLON AND LARGER PLANT MATERIAL INSTALLED BY THE LANDSCAPE CONTRACTOR SHALL BE WARRANTED BY THE CONTRACTOR FOR A MINIMUM OF ONE (1) CALENDAR YEAR COMMENCING AT THE TIME OF CERTIFICATION OF ACCEPTABILITY BY THE OWNER'S REPRESENTATIVE. 2. THE LIFE AND SATISFACTORY CONDITION OF ALL OTHER PLANT MATERIAL (INCLUDING SOD) INSTALLED BY THE LANDSCAPE CONTRACTOR SHALL BE WARRANTED BY THE CONTRACTOR FOR A MINIMUM OF ONE (1) CALENDAR YEAR COMMENCING AT THE TIME OF CERTIFICATION OF ACCEPTABILITY BY THE OWNER'S REPRESENTATIVE. 3. REPLACEMENT: ANY PLANT NOT FOUND IN A HEALTHY GROWING CONDITION AT THE END OF THE WARRANTY PERIOD SHALL BE REMOVED FROM THE SITE AND REPLACED AS SOON AS WEATHER CONDITIONS PERMIT. ALL REPLACEMENTS SHALL BE PLANTS OF THE SAME KIND AND SIZE AS SPECIFIED IN THE PLANT LIST. THEY SHALL BE FURNISHED PLANTED AND MULCHED AS SPECIFIED UNDER "PLANTING", AT NO ADDITIONAL COST TO THE OWNER. WARRANTY IS TO EXCLUDE DAMAGE CAUSED BY FLOODS, LIGHTING STRIKES, FREEZING, WINDS OVER 45 MPH, FIRE, VANDALISM, HERBIVORE ANIMALS, DISEASE, INSECTS, WATER RESTRICTIONS, GOVERNMENT ACTIONS OR ACTS OF NEGLIGENCE BY THE OWNER OR OTHERS. 4. IN THE EVENT THE OWNER DOES NOT CONTRACT WITH THE CONTRACTOR FOR LANDSCAPE (AND IRRIGATION) MAINTENANCE, THE CONTRACTOR IS ENCOURAGED TO VISIT THE PROJECT SITE PERIODICALLY DURING THE ONE YEAR WARRANTY PERIOD TO EVALUATE MAINTENANCE PROCEDURES BEING PERFORMED BY THE OWNER, AND SHALL NOTIFY THE OWNER IN WRITING OF MAINTENANCE PROCEDURES OR CONDITIONS WHICH THREATEN VIGOROUS AND HEALTHY PLANT GROWTH. IT IS SUGGESTED SUCH SITE VISITS SHALL BE CONDUCTED A MINIMUM OF ONCE PER MONTH FOR A PERIOD OF TWELVE (12) MONTHS FROM THE DATE OF ACCEPTANCE. V.SUBMITTALS 1. FOR ALL LANDSCAPE INSTALLATIONS, THE CONTRACTOR SHALL SUBMIT PRODUCT DATA IN THE FORM OF MANUFACTURERS' CUT SHEETS AND CATALOG DATA FOR ALL PRODUCTS, MATERIAL AND EQUIPMENT CLEARLY INDICATING THE SPECIFIC PART OR PRODUCT CATALOG NUMBER(S) FOR APPROVAL AND SUBMIT A MATERIALS LIST INDICATING ALL PLANT SPECIES, QUALITY AND SIZE. 2. SUBMIT 6 COPIES OF REQUESTED INFORMATION, NEATLY BOUND AND INDEXED PER CATEGORY. 3. THE CONTRACTOR SHALL SUBMIT A LANDSCAPE COORDINATION DRAWING, INDICATING CONTRACTOR'S PROPOSED LOCATION OF TREES, SHRUBS, GROUNDCOVERS AND MULCH.THIS DRAWING SHOULD BE PREPARED ON A COPY OF THE LANDSCAPE PLAN PROVIDED IN THESE DRAWINGS AND SHALL CLEARLY DEPICT ADJUSTMENTS OR CHANGES THE CONTRACTOR PROPOSES TO THE PLANT SPECIES, SIZE OR LOCATION. THE DRAWINGS SHALL INDICATE ALL PROPOSED SUBSTITUTIONS OF SIZE, AND/OR MATERIAL. 4. ALLOW TWO WEEKS FOR THE ENGINEER TO COMPLETE REVIEW AND APPROVAL OF PRODUCT DATA, AND COORDINATION DRAWINGS. ENGINEER WILL NOT BE RESPONSIBLE FOR PROJECT DELAYS RELATED TO DELIVERY AND TRANSMISSION OF THE INFORMATION AND DOCUMENTATION ONCE INFORMATION HAS LEFT ENGINEER'S OFFICE. ITEMS REQUIRING A LONG LEAD TIME SHOULD BE SUBMITTED AS SOON AS POSSIBLE. 5. WARRANTY: CONTRACTOR SHALL SUBMIT A WARRANTY LETTER TO OWNER, INDICATING THE WARRANTY PERIOD, WARRANTY REQUIREMENTS (AS SPECIFIED IN THESE DRAWING AND SPECIFICATIONS), AND DATES OF WARRANTY PERIOD, WHICH SHALL BEGIN AT THE DATE OF ISSUANCE OF PROJECT CERTIFICATE OF OCCUPANCY, AND END TWELVE (12) MONTHS AFTER. 6. CERTIFICATION: CONTRACTOR SHALL SUBMIT CERTIFICATION STATING THAT: PLANT SPECIES AND SIZE CONFORM TO THOSE INDICATED ON THE DRAWINGS; ALL NURSERY STOCK IS IN ACCORDANCE WITH GRADES AND STANDARDS FOR NURSERY PLANTS, LATEST EDITION, PUBLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES; ALL PLANTS ARE FLORIDA GRADE NO. 1 OR BETTER AS DETERMINED BY THE FLORIDA DIVISION OF PLANT INDUSTRY; ALL PLANTS ARE HEALTHY, VIGOROUS, SOUND, WELL-BRANCHED, AND FREE OF DISEASE AND INSECTS, INSECT EGGS AND LARVAE AND HAVE ADEQUATE ROOT SYSTEMS; TREES FOR PLANTING IN ROWS ARE UNIFORM IN SIZE AND SHAPE. THIS CERTIFICATION IS NECESSARY PRIOR TO ACCEPTANCE OF WORK BY THE OWNER. 1.QUALITY. PLANT MATERIALS USED TO MEET THE REQUIREMENTS OF THIS PLAN SHALL CONFORM TO THE STANDARDS OF FLORIDA NO. 1 OR BETTER AS GIVEN IN THE MOST RECENT EDITION OF "GRADES AND STANDARDS FOR NURSERY PLANTS", FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, OR STANDARDS EQUAL THERETO. ALL PLANT MATERIALS SHALL BE INSECT- AND DISEASE-RESISTANT, AND SHALL BE CLEAN AND REASONABLY FREE OF WEEDS AND NOXIOUS PESTS OR DISEASES WHEN INSTALLED. PLANT MATERIALS THAT ARE KNOWN TO BE INTOLERANT OF PAVING ENVIRONMENTS, WHOSE PHYSICAL CHARACTERISTICS MAY BE INJURIOUS TO THE PUBLIC, OR THAT PRODUCE A QUANTITY AND QUALITY OF DEBRIS SO AS TO PRESENT MAINTENANCE DIFFICULTIES SHALL NOT BE SPECIFIED FOR USE UNDER THIS CODE. 2.TREES. A.TREES SHALL BE SPECIES HAVING AN AVERAGE MATURE SPREAD OF CROWN OF GREATER THAN FIFTEEN (15) FEET IN ST. LUCIE COUNTY AND HAVE TRUNKS THAT CAN BE MAINTAINED IN A CLEAN CONDITION. TREES HAVING A MATURE CROWN SPREAD OF LESS THAN FIFTEEN (15) FEET MAY BE ARRANGED OR GROUPED SO AS TO CREATE THE EQUIVALENT OF A FIFTEEN (15) FOOT SPREAD, HOWEVER, ANY SUCH GROUP OR GROUPS SHALL ONLY COUNT AS ONE (1) TREE FOR THE PURPOSE OF COMPLIANCE WITH THIS CODE. B. PALM TREES MAY BE CLUSTERED INTO GROUPS OF THREE (3) TO ACHIEVE THIS MINIMUM FIFTEEN (15) FOOT CROWN. ALL PALM TREES SHALL HAVE A MINIMUM CLEAR TRUNK OF TEN (10) FEET WHEN INSTALLED. THREE (3) PALM TREES ARE EQUAL TO ONE (1) SHADE TREE HAVING A MATURE SPREAD OF FIFTEEN (15) FEET. C. TREE SPECIES SHALL BE A MINIMUM OF TWELVE (12) FEET IN HEIGHT AND HAVE A CALIPER OF TWO (2) INCHES AT FOUR AND ONE-HALF (4½) FEET ABOVE THE GROUND WHEN INSTALLED. HEIGHT SHALL BE DETERMINED BY THE AVERAGE END OF ALL BRANCHES NOT THE TALLEST BRANCH OR TWO (2). D. ALL REQUIRED TREES, EXCEPT PALMS, SHALL HAVE A MINIMUM OF FIVE (5) FEET OF CLEAR TRUNK AND A MINIMUM FIVE-FOOT CANOPY SPREAD AT TIME OF PLANTING. E.TREES OF SPECIES WHOSE ROOTS ARE KNOWN TO CAUSE DAMAGE TO PUBLIC ROADWAYS OR OTHER PUBLIC WORKS SHALL NOT BE PLANTED CLOSER THAN TWELVE (12) FEET TO SUCH PUBLIC ROADS OR WORKS, UNLESS THE TREE ROOT SYSTEM IS COMPLETELY CONTAINED WITH A BARRIER FOR WHICH THE MINIMUM DIMENSIONS SHALL BE FIVE (5) FEET SQUARE AND FIVE (5) FEET DEEP, AND FOR WHICH THE CONSTRUCTION REQUIREMENTS SHALL BE FOUR-INCH THICK CONCRETE REINFORCED WITH NUMBER SIX (6) ROAD MESH (6X6X6) OR EQUIVALENT. F.NONE OF THE TREES LISTED IN ST. LUCIE COUNTY LAND DEVELOPMENT CODE SECTION 7.09.03(F) SHALL BE PLANTED.WHERE SUCH SPECIES ALREADY EXIST, THEIR REMOVAL SHALL BE A CONDITION OF ANY FINAL DEVELOPMENT ORDER. G. FIFTY PERCENT (50%) OF THE REQUIRED TREES SHALL BE SPECIES OTHER THAN PALM TREES, EXCEPT THAT ON NORTH AND SOUTH HUTCHINSON ISLAND THE PUBLIC WORKS DIRECTOR MAY APPROVE THE USE OF MIX OF TREE SPECIES OF MORE THAN FIFTY PERCENT (50%) PALM TREES IF IT IS DEMONSTRATED TO THE SATISFACTION OF THE DIRECTOR THAT THE PARTICULAR SITE IS EXPOSED TO HIGH SALT IMPACTS OR OTHER SIMILAR NATURAL CONDITIONS THAT ARE NOT CONDUCIVE TO NON-COASTAL PLANT SPECIES. H. WHEN MORE THAN TEN (10) TREES ARE REQUIRED TO BE PLANTED TO MEET THE REQUIREMENTS OF THIS CODE, A MIX OF SPECIES SHALL BE PROVIDED. THE MINIMUM NUMBER OF SPECIES TO BE PLANTED ARE INDICATED IN TABLE 7-30. WHEN A MIX OF SPECIES IS REQUIRED, NO SINGLE SPECIES SHALL EXCEED A TWO (2) TO ONE (1) RATIO RELATIVE TO ALL OTHER INDIVIDUAL SPECIES. I.ONE HUNDRED PERCENT (100%) OF THE TREES SHALL CONSIST OF NATIVE SPECIES SUCH AS LIVE OAKS (QUERCUS VIRGINIANA), LAUREL OAKS (QUERCUS LAURIFOLA), SLASH PINE (PINUS ELLIOTTI), OR OTHER SPECIES LISTED IN SLC LDC SECTION 7.09.04(L)(2), NATIVE AND DROUGHT-TOLERANT VEGETATION. THE REQUIREMENTS FOR CANOPY OR SHADE TREES SHALL BE EXEMPTED BY THE PUBLIC WORKS DIRECTOR WHEN THE PROPOSED LOCATION OF THE CANOPY OR SHADE TREES WILL BE IN CONFLICT WITH OVERHEAD POWER LINES AS DESCRIBED IN SLC LDC SECTION 7.09.03(E)(2)(L) OF THIS CODE. THE PUBLIC WORKS DIRECTOR SHALL REQUIRE MITIGATION AT A MINIMUM RATIO OF ONE (1) INCH TO ONE (1) INCH TO COMPENSATE FOR THE LOSS OF ANY CANOPY OR SHADE TREE AS OUTLINED IN SLC LDC SECTION 6.00.05(D). J.IF ANY DEVELOPMENT ACTIVITY IS TO OCCUR ON A SITE LOCATED ON ANY PARCEL OF LAND LOCATED WEST OF THE ATLANTIC INTERCOASTAL WATERWAY, THAT HAS, OR HAS BEEN DETERMINED TO HAVE, NATIVE SCRUB VEGETATION AND HABITAT PRESENT PRIOR TO THE COMMENCEMENT OF BUILDING ACTIVITIES, ANY NEW LANDSCAPING MATERIAL INTRODUCED TO THE SITE PURSUANT TO THE REQUIREMENTS OF THIS CODE, SHALL COMPLY WITH THE RESTRICTIONS OF SECTION 7.09.04(N). K.NO TREE SHALL BE PLANTED WHERE IT COULD, AT MATURE HEIGHT, CONFLICT WITH OVERHEAD POWER LINES. LARGER TREES (TREES WITH A MATURE HEIGHT OF THIRTY (30) FEET OR MORE) SHALL BE PLANTED NO CLOSER THAN A HORIZONTAL DISTANCE OF THIRTY (30) FEET FROM THE NEAREST OVERHEAD POWER LINE. MEDIUM TREES (TREES WITH A MATURE HEIGHT BETWEEN TWENTY (20)--THIRTY (30) FEET) SHALL BE OFF-SET AT LEAST TWENTY (20) FEET HORIZONTALLY FROM THE NEAREST OVERHEAD POWER LINE. SMALL TREES (TREES WITH A MATURE HEIGHT OF LESS THAN TWENTY (20) FEET) SHALL NOT BE REQUIRED TO MEET A MINIMUM OFF-SET, EXCEPT THAT NO TREE, REGARDLESS OF SIZE SHALL BE PLANTED WITHIN FIVE (5) FEET OF ANY EXISTING OR PROPOSED UTILITY POLE, GUY WIRE, PAD MOUNTED ELECTRICAL TRANSFORMER OR OTHER UTILITY TRANSMISSION/ COLLECTION STRUCTURE OR EQUIPMENT. PALM TREES WITH A MAXIMUM MATURE HEIGHT GREAT ENOUGH TO INTERFERE WITH OVERHEAD POWER LINES SHALL NOT BE PLANTED BELOW OVERHEAD POWER LINES AND SHALL BE LOCATED A MINIMUM OF TWO AND ONE-HALF (2½) FEET, PLUS THE AVERAGE MATURE FROND LENGTH, OUTSIDE OF ANY UTILITY RIGHT-OF-WAY. THE PUBLIC WORKS DIRECTOR, IN CONSULTATION WITH FLORIDA POWER AND LIGHT COMPANY, SHALL MAINTAIN A LIST OF TREES TYPICALLY FOUND IN THE SOUTH FLORIDA AREA THAT AT MATURE GROWTH HEIGHTS CAN REASONABLY BE EXPECTED TO INTERFERE WITH OVERHEAD POWER LINES. 3.SHRUBS AND HEDGES. SHRUBS SHALL BE A MINIMUM OF TWENTY-FOUR (24) INCHES IN HEIGHT ABOVE GRADE IMMEDIATELY AFTER PLANTING. HEDGES, WHERE REQUIRED, SHALL BE PLANTED AND MAINTAINED SO AS TO FORM A THIRTY-INCH OR HIGHER CONTINUOUS, UNBROKEN, SOLID VISUAL SCREEN WITHIN EIGHTEEN (18) MONTHS AFTER THE TIME OF PLANTING. TWENTY-FIVE PERCENT (25%) OF THE QUANTITY OF PLANTED SHRUBS SHALL CONSIST OF NATIVE SPECIES. 4.VINES. VINES SHALL BE A MINIMUM OF TWELVE (12) INCHES IN HEIGHT IMMEDIATELY AFTER PLANTING AND MAY BE USED IN CONJUNCTION WITH FENCES, SCREENS, OR WALLS TO MEET PHYSICAL BARRIER REQUIREMENTS. 5.GROUND COVERS. GROUND COVERS, OTHER THAN GRASS, SHALL BE PLANTED IN SUCH A MANNER AS TO PRESENT A FINISHED APPEARANCE AND REASONABLY COMPLETE COVERAGE WITHIN FOUR (4) MONTHS AFTER PLANTING. 6.LAWN GRASS. GRASS AREAS SHALL BE PLANTED IN SPECIES NORMALLY GROWN AS PERMANENT LAWNS IN ST. LUCIE COUNTY. GRASS AREAS MAY BE SODDED, PLUGGED, SPRIGGED, OR SEEDED, EXCEPT THAT SOLID SOD SHALL BE USED IN SWALES OR OTHER AREAS SUBJECT TO EROSION. WHEN OTHER THAN SOLID SOD IS USED, PROTECTIVE MEASURES SHALL BE TAKEN UNTIL COMPLETE COVERAGE IS ACHIEVED. 7.NATIVE VEGETATION. THE PRESERVATION OF EXISTING NATIVE VEGETATION SHALL BE REQUIRED WHERE THE LOCATION OF SAID VEGETATION IS NOT IN CONFLICT WITH THE PROPOSED BUILDING OR PARKING AREAS. THE PUBLIC WORKS DIRECTOR, MAY REQUIRE THAT REASONABLE CHANGES BE MADE TO ANY SITE PLAN OR APPLICATION FOR BUILDING PERMIT FOR THE PURPOSE OF PRESERVING OR PROTECTING ANY SPECIAL OR UNIQUE EXISTING TREE(S) OR NATIVE HABITAT. 8. THE CONTRACTOR SHALL ATTEMPT TO PRESERVE AS MANY EXISTING TREES AS POSSIBLE AND FEASIBLE. TREES THAT ARE PRESERVED MAY BE CREDITED TOWARDS THE SITE TREE REQUIREMENT IF THEY MEET THE SPECIFICATIONS. 9. THE CONTRACTOR SHALL COORDINATE THE PLACEMENT OF TREES, SIGNS AND LIGHTS SUCH THAT ALL SIGNAGE IS EASILY SEEN AND LIGHTING WORKS FOR ITS INTENDED PURPOSE. TREE PLACEMENT MAY VARY FROM THIS PLAN TO ACHIEVE THIS REQUIREMENT. 10. ALL LANDSCAPE MATERIAL IN SHOCK WILL BE REPLACED PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. 11. ALL LANDSCAPE IS REQUIRED TO BE IRRIGATED BY AUTOMATIC MEANS. 12. PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY ALL CATEGORY I LISTED INVASIVE SPECIES SHALL BE ERADICATED FROM THE SITE. LANDSCAPE MATERIAL STANDARDS & NOTES FLORIDAREVISIONS DATE1835 - 20TH STREETVERO BEACH, FL 32960PH. (772) 569-0035FX. (772) 778-3617MELBOURNE, FL - PH (321) 253-1510FT. PIERCE, FL - PH (772) 468-9055C:\CIVIL ON HARD DRIVE\2020\20-0029 Indian River Spirits\DWG\20-0029 C15 LANDSCAPE PLAN.dwg 9/24/2020 1:11 PMGREGG REEDST. LUCIE COUNTYINDIAN RIVER SPIRITSSITE IMPROVEMENTS3200 NORTH KINGS HIGHWAY