Loading...
HomeMy WebLinkAboutPermit Worksheetsit,.: a .,r : ,' •'. '. :. .. _ _.. -IERMIT NUMBER Installer •e h K K 04-p Address of home 2,fr� being installed Manufacturer��>`T Lenpthx:width NOT& ' If home to a single wide fill out one half ' the blocking plan if hord a Is a triple or quad wide sketch In temalnder of home I understand Lateral Ann Systems cannot be used on. any home (new or where the sidewall ties exceed 5 It 4 in, Installer's:�initiais ��;.• PERMIT WC7FIKSHEET page 1 of z 1 New Home Used Home _ ®� Home installed to -the Manufacturer's Ins tallatlon Manual ❑ Homexis Installed I aocgrdanoe with `Rule 16-C []�• Single :wide �!' Wind Zone Il ' _ ,❑ Wind Zone III [� Dcuble.Wide ❑ Installation Decal.# Trlpla/Quad ❑ Serial#3740'r�Tly.. PIER SPACING TABLE FOR USED HOMES Load: tg oapealapaolty Footer .s1T • (sg In) 16' x 16' (266) 18112' x 18 i/2' (842) 20' x 20' '(40b) 22' x 22T (4a4)- 24' X 24' (a76)• 26' X '26. (676) 1 DOD st a 00 Dst 4 6 6 :.8.. 8 00 6 B 8. 0 s 26006 6 a600 s 8 8 abuu 8' 8 interpoiatea;rom time '►sc:-i pier spaomp uwie. PiER PAD SIZES I-beam pler.'pad size r rk 2 2 • '' Perimeter pier pad size l i Other pier pad sizes % rr X ?2 r� (required by the mfg.) ®'Drawthe approximate locations of marriage wall openings 4 foot or greater. Use this symbol to -show the piers, List sill marriage wall openings greater than 4 foot and.thelr' pier pad sizes below, Opening Pier padtsize o2 2y,� TIEDOWN COMPONENTS Longitudinal Sfab11lz/n� Devlce (LSD) Manufacturer l�41 K K rzc 7,",W L' Longitudinal StablikingDevlce w/Lateral Arrils Manufacturer- ✓h�`y •�r.� �� POPULAR PAD S ZES re�X-�7b;c� iftiE�'L:1 (—ANCHORS 4 it _ ft r FRAME TIES within 21 of end of home spaced at 5140 oo OTHER IE5—I Nu bar Sidewall Longitudinal Marrlags wall Shearwall 4 " " PERMIT WORKSHEET page 2 of 2 + •PERMIT NUMBER :.fflu POCKET ETROME I ER TES The pbcket penetrometer tests are rounded down to psi or check hereto declare 1000 lb. soil --S,--vdt?I5ut testing. X X X POCKET PENETROMETER. TESTING METHOD I. Test the perimeter of the hothe at 6 locations.. 2. Take the reading at the depth of the•footer; S. Using 600 lb. lhorements, take the lowest reading and round. down to that increment. X TORQUE PROBE TEST The results of the torque probe test Is inch pounds or check here If you are declaring 51 anchors without t ing _ : A test showing 275 Inch pounds or less will require 5 foot anchors, . . Note: A state approved lateral arm.system Is being used and 4 ft. .anchors are allowed at4he sldewall locations. i understand 5.ft anchors are,. required at all centerline tie pointp where the torque test reading Is 276 or less and where the mobile home manufacturer may. requires anchors with 4000 lb holding capacity. Installer's inittalW.2, ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALL -R Installer Name --r 2, /-,r4 04 Date Tested l / r/ /:za I it Electrical lbrineot electrical conductors between multi -wide units, but not to the main power ource. This•Ingludes the bonding wire between must-wlde'units. Pg. Phimbinq bnneot all sewer drains to an existing sewer tap or septic tank Pg. onneot all potable water supply piping to an existing water meter, water tap, or other rdependerlt water supply sydiems. Pg..__ site Preparation Debris and organic material remov Water drainage: Natural aie Pad Other Fasten ng multi wide un to Floor. Type Fastener. enAth: Spacing: Walls: Type Fastener. Len Spacing: Roof: Type Fastener. Length: Spacing: Fcr.used homes min. 30 gauge, & ida, galvanized m tal strip will be centered'over the peak of the -root and fastened With gale. roofing nails at 2" on center on both sides of the centerllne. Gasket rwntherpro"Una r auin:enentf I understand a property installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marrlape'walls are a result of a poorly installed or no gasket being Installed I understand a strip of tape will not serve as a gasket. Installer's initials' �• Type gasket Installed: Pg. Between Floors Yes Between Walls Yes Bottom of ridgebeam Yes ci Weatherproofing The bottomboard will be repaired and/or taped. Yes Pp. Siding on units Is installed to manufacturer's speoKloatlons. Yes Fireplace chimney installed so as not to allow intrusion of rain water. Yes Nflsee raneous Skirting to be Instatidd. Yes t!--:�—No . . Dryer vent installed outside of skirting. Yes Range downflow vent instailed'outslde.of skirting. Yes WA - Drain lines supported at 4 foot intervals. Yes Electrical crossovers protected. Yes Other.: aU information given with thl is accurate and true based on Installer Signature Date /• ,