Mobile Home Inspection Report
All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this
completed Inspection Report and copies of both sides of the Title to the home.
All used Mobile homes must be Wind Zone 11 certified.
Owner: V V INV j0N & AAQ �� VIL L&-f Date: a
(Print or type) T C�
Address: 3CA 0 TH ORT' ALE {/
Physical Loca' n of Home)
Year / Manufacturer ao /? ILAY Serial # CitL0D&a9M HUD Plate # h(TA r (# Ito 91f
Width Length Single _�� Double Wind Zone
C = In Compliance N = Not in Compliance
Fire Safety / Electrical
G 1. Smoke Detector: Installed Missing
G 2. Electrical System Checked: Exposed Wiring Other
Ci 3. Distribution Panel: Missing Loose Main Missing Breaker Missing
Unplugged Opening Other
Ci 4. Electrical Fixtures: Missing Installed Improperly
Improperly Wired Loose Wire
GFCI receptacles not where required 101,
Ci 5. Electrical Ground: Chassis Main Panel Gas Pipe L'ii, P4 ,
0�
00
Revised 3/9/05
Page 1 of 3
Construction
1. Exit Doors Operable: Front
Back Other
2. Exit Door Locks: Missing
Inoperable
—C— 3. Egress windows: Missing
Inoperable-
4. Windows: Broken Glass
Inoperable
5. Screens: Missing Damaged
_C_ 6. Floor System: Joist
Decking Area Damaged
E 7. Interior Paneling: Missing Loose Damaged
8. Rodent Proofing: Bottom Board
Pipe openings Other
9. Leaks Apparent: Ceiling Doors
Floor Roof
—i 10. Vertical tie -down straps: Missing
ShortDamaged
11. Structural modifications since manufactured: YES NO�
12. Walls: Structurally Unsound Loose Weather tight _
Plumbing
G 1. Trap: Missing Not connected Other
�i 2. Plumbing fixtures: Missing Not installed Not Vented
3. Relief Valve: Missing Inoperable Other
G 4. Drain Waste and Venting Piping: Missing Not supported
Clean outs Use of fittings Not capped
Heating and Air Conditioning
C_ 1. Heating Appliances: Missing Not Connected Other.
C 2. Deleted Heating/AC system: Not installed Other
G 3. Thermostat: Missing Inoperable
ii 4. Air registers: Missing Inoperable
G 5. Ducts: Not sealed Missing Collapsed
Page 2 of 3
6. Gas furnace Water heater vent: Missing Loose
_ 7. Return Air: To Furnace.,, ToWC.•.:. .. .. From roams...:
...:
G 8. Range: Vent Hood -
9. Gas Valve: Accessible Installed improperly
10. Gas lines: Not capped Not supported Kinked
Not bonded
Summary
1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO_��
2. Will a remodeling permit be required? YES NOLA/—
The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent
than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be
limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232
IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO
BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY,
A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS
MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT.
NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE-
LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN
SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED.
A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX
THEIR SEAL.
Date inspected: Iola 9 7
Inspected By: 5-MVE Mou a:
Slgn Lure required
Phone Number: (�IJ�!�� lb7f)-73aj
License # 3 L 3 Jy
Page 3 of 3
Engl�O Sea// "
STEVEN G. WOOD, P.E.
FL 1ZCENSE 34398
950 SULTAN ODE,
pGRT ST LUCIE, FL