HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method"
Project Name: WYNNE THE -GRAND CARLTON
Builder Name: WYNNE BUILDING COPR.
Street: ��jq� ��C�C>��Z
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County:, St. Lucie (Florida Climate
Zone 2) .
1. New construction or existing . New. (From Plans)
9. Wall Types(1442.0 .sgft.)
Insulation ... Area.
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1476.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. Knee_ Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
.11. Ducts
R ' ft2
7. Windows(141.3 sqft.) Description Area
a: Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: Sgl, U=0.54 101.25 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8- SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtulhr . Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50'
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (1445.5 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2.
None
c. NIA R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 46.72
Glass/Floor Area: 0.098
PASS
Total Baseline Loads: 48.09
hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance,
' _;�io
with the Florida Energy Code.
,�,�, y..; 1 ' _� 0
PREPARED BY:
Before construction is completed
W 4
DATE: 1-8-20
this building will be inspected for
compliance with Section 553.908
;0;
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Coe'
OWNER/AGEN
BUILDING OF 1
DATE: ®. %b
DATE:
-
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 11403.3.2.1. .
- Compliance requires an Air Barrier and Insulation Inspection Checklist.in accordance with ��4 ject requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R40REW-T E)
CODE COMPLIANCE
ST, LUCIE COUNTY
MCC
1/8/2020 2:47 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY:' CHECKLIST REPORT
PROJECT
Title; WYNNE THE GRAND CARL Bedrooms:. 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
#'of Units: 1 Worst.Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate'Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No'
County:
St. Lucie
Jurisdiction: ST, LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE ;
Family Type: Single-family
FL,
'New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
. Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree -Days Moisture
Range
FL, Fort Pierce FL VERO BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 115,68
SPACES
Number: Name Area Volume. Kitchen Occupants.
Bedrooms
InfilID .Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1. No.
Yes
Yes
3 M.BATH 56 448 No 0
1. Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes.
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes .
Yes •
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING . 468 3604 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge lnsulatio BEDROOM 52 ft 0
301 ft2
____
0 1
0.
2 Slab -On -Grade Edge lnsulatio WIC 1 ft 0
63 ft2
. _
0 1
0
3 Slab -On -Grade Edge lnsulatio M. BATH 8 ft 0
56 ft2
0 1
0
4 Slab -On -Grade Edge lnsulatio . KITCHEN 1 ft 0
192 ft2
____
0 1
0
5 Slab-On=Grade Edge lnsulatio BATH ' .5ft 0
45 ft2
_
0 1
0
6 Slab -On -Grade Edge lnsulatio BEDROOM 2 32.2 ft 0
203.6 ft2
__
.0 1
0
7 Slab -On -Grade Edge lnsulatio ENTRY 7 ft . 0
55 ft2
___
0 1
0:
1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Editiop (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0
42 ft2.
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
0
1
0
ROOF
/ Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
.0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
10 Knee Wall (Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
-
Height
Sheathing Framing
Solar Below
o
_ 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
_ 2 SW=>NE Exterior Concrete Block - Int InsuBEDR00M
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
3 NW=>SE Exterior Concrete. Block - Int InsuBEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5 NE=>SW Exterior Concrete Block- Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6 NE=>SW ,Exterior Concrete Block - Int InsEREDR00M 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7 SE=>NW Exterior Concrete Block - Int InsEKEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
_ 8 S=>N Exterior Concrete Block - Int InsREDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
9 SW=>NE Exterior Concrete Block - Int InsB EDR00M 2
4.1 2
0 8
0
16.0 f12
0
0
0.4
0
_ 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY
4.1 6
0 81
0
48.0 ft2
0
0
0.4
0
_ 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY
4.1 1
0 8
0
8.0 ft2
.0
0
0.4
0
_ 12 SW=>NE Exterior Concrete Block -'Int InsuLAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior Concrete Block - Int Inst GREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block - Int insd3REAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 IKIPI IT SI I11A11AADV t%UCf%V1 ter 000nor
WALLS
Adjacent ;9 Ornt To Wall
Type Space Cavity Width Height
-
Sheathing Framing Solar Below
o
15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2
0.23 0.4
0
DOORS
# Ornt
Door Type Space Storms U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated ENTRY None .39 3
1 6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
V # Ornt ID Frame
Overhang
Panes NFRC U-Factor. SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal.
5 NW=>SE14 Metal
Low-E Single Yes 0.54 0.25 N 32.9 ft2 1 ft 0 in
Low-E Single Yes 0.54 0.25 N 6.9 ft2 1 ft 0 in
Low E Single Yes 0.54 0.25 N 24.0 ft2 6 ft 0 in
Low-E Single Yes 0.54 0.25 N 37.5 ft2 1 ft 0 in
Low E Single Yes 0.55 0.25 N 40.0 ft2 8 ft 0 in
1 ft 5 in Drapes/blinds
1 ft 5 in None
1 ft 5 in None
1 ft 5 in None
1 ft 5 in Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1 315 ft2
315 ft2 24 ft 8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH
�1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .1233
ACH 50
7
•V
HEATING SYSTEM
# System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split Singl SEER: 15 34.8 kBtu/hr cfm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType Location EF Cap Use SetPnt
Conservation
1 Electric
None Garage 0.97 40 gal 60.9 gal 120 deg
None
1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPI IT Al IMMAPV rtw=r k-1 ICT Q=onOT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ --- Supply - =
--- Return --
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic . 6 250 ft2
Attid
65 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan Feb Mar
Heating Jan HFeb f X� Mar
Venting
f
A r
Apr
f
Ma
May
Jun Jul
Jun Jul
Au
AuBeSp
Oct
f Oct
Nov
Nov
Dec
Dec
Jan Feb [[�X Mar
tX
Apr
[
May
Jun Jul
Aug
Se
tX Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM 78
PM 80
78
80
78
78
78
78 78
78
78
80 80
80
80
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM 78 •
78
78
78
78 78
78
78
78 78
78
78
PM 78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM 66
PM 68
66
68
66
68
66
68
66 68
68
68
68 68
68
68
68 68
68
68
68 68
66
66
Heating (WEH) AM 66
66
66
66
66 68
68
68'
68 68
68
68
PM 68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 ibs/sq.ft.
ft2
ft
0.3
CLST.
Default(8 lbs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
JUNIOR M. BED
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
POWDER
Default(8 lbs/sq.ft.
ft2
ft
0.3
NOOK
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/s .ft.
ft2
ft
0.3
ENTRY
1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
w
Design Location: FL, Fort Pierce
_
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier,
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
the insulation and any gaps in the air barrier shall be sealed.
The insulation in any dropped ceiling/soffit
Access openings, drop down stairs or knee wall doors to
shall be aligned with the air barrier.
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls.
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed,
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge'of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed, light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight•and IC rated.
Plumbing and wiring _
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Pytpnd behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler 92mu-Wdu and walls or befflngs,
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1/8/2020 2:47 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
I. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (ifmultiple-family)3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER .
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.543
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump, HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: A a';�,
Address of New Home:\"',>°%L1 �r\ �/ d0 City/FL Zip: FT. PIERCE, FL ��4 S�
1/8/2020 2:47:26 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1