HomeMy WebLinkAboutAPPROVED 5- Signed and Sealed Engineering CalculationsForensic Engineering Consuitants, inc. MEMBRANE ATTACHMENT CALCULATIONS Project Name St. Lucie Battery Report No.: ATRT-MB-20.143 Project Address 5500 Orange Avenue Ft. Pierce, FL - 32947 Deck Substrate Recover (Metal), Insulated Mean Roof Height 20.3 Feet Configuration Low Slope Roof Area (Approx.) 9090 Sq.Ft Category II Mean Roof Width 87.0 Feet Exposure Condition C Perimeter Width 8.1 Feet Building Type Enclosed Parapet Height 0.0 Feet Base Wind Speed 170 mph Corner Zones 8.1' x 8.1' Each Slope V 0.0 Slope H 12.0 Slope Angle° 0.00 Uplift Pressures qZ - 0.00256 KZ Kt Kd V2 P qZ (GCP - GCP;) qZ KZ K:t Kd V GCP GCP; 57.149 0.904 1.005 0.85 170 -1.00 0.18 Field -1.80 0.18 Perimeter -2.80 0.18 Corner Field Pt Alt -67.44 psf Pt asd -40.46 psf Perimeter P2 u,t -113.16 psf P2 asd -67.89 psf Corner P3 pit. -170.30 psf P3 asd-102.18 psf Proposed System Carlisle Sure -Weld TPO Single Ply Roof Systems Product Approval No. FL14083-R24 (Page 83 of 87) System No. R-64 System Design Pressure -60 psf Membrane Full Width 126 inches Side Lap 6 inches Net Width 120 inches Membrane Red. Width 66 inches Side Lap 6 inches Net Width 60 inches Membrane Red. Widtl- 66 inches Side Lap 6 inches Net Width 60 inches Fasteners Carlisle HP Purlin Fasteners and Piranha Plates (Fasten thru' roof assembly into purlins) Fastener Spacing in Lap of Membrane 6 inches # Rows 1 Min. Characteristic Resistance Force-300.00 Ibf Verify with TAS-105 Tests Fastener Spacing {(MCRF/P;) x 144}/Row Spacing Full Width Mmbrn Red. Width Mmbrn Red. Width Mmbrn Field Fastener Spacing 8.90 17.79 17.79 Perimeter Fastener Spacing 5.30 10.60 10.60 Corner Fastener Spacing 3.52 7.05 7.05 RECOMMENDED MEMBRANE ATTACHMENT PATTERN Field Laps @ 120" o.c. (max. Purlin Spacing) Full Width Sheet 6 inches on center Perimeter Laps @ 60" o.c. (max. Purlin Spacing) Reduced Width Sheet 6 inches on center Corner Laps @ 60" o.c. (max. Purlin Spacing) Reduced Width Sheet 6 inches on center These calculations have been done in accordance with ASCE 7-10, based on the information provided by the contractor. The roof system must be installed in accordance with the FBC & manufacturer's recommendations. Ensure that roof system meets all fire rating & drainage requirements of Florida Building Code, before installation. Verify that existing roof meets all FBC requirements to receive a recover roof, before installing new roof Sincerely Forie. nsic Engineering Consultants, Inc. R. N. Sailappah, P.E... li Principal Engineer Florida Registration No. 46696 Forensic Engineering.Consultantsjnc. (CA # 8265), P.O. Box 970034, Boca Raton, FL- 33497 Ph (561) 901 8490 Fax (561) 218 3830