HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE GRAND CARLTON IMPAC
BuilderName: WYNNE BUILDING CO PR.
Street: `05 5 G %> �`�,��
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1.. New construction or existing New (From Plans)
9. Wall Types .(1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a.'Concrete Block- Int Insul, Exterior
R=4.1 1250.00 ft2
b. Frame -Wood, Adjacent
R=11.0 192.00 ft2.
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10.Ceiling.Types (1476.0 sqft.)
Insulation Area
a. UnderAttic (Vented)
R=30.0. 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditionedfloorareabelowgrade(ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Wmdows (141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
k.Btu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating.systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
.8. Floor Types (1445.5 sqft.) Insulation Area
a. Electric
Cap:40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
b. Conservation features
EF:0.970
b. N/A R= ft2
None
c. N/A R= ft2
N
15. Credits
Pstat
Total Proposed Modified Loads: 47.50
Glass/Floor Area: 0.098
PASS
�7
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of the plans and
al
,
this calculation are in compliance with the Florida Energy
specifications covered by this
_ 0,
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
fj,lf
DATE: 1-9-20
this building will be inspected for:
4w � t7
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
OWNER/AG N •
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation In Checklist in accordance -with R402.4.1A and thin project requires
an envelope leakage'test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1:2 .
RENEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
1 /8/2020 4:18 PM EnergyGaugeO USA 6:0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant SMCC Page 1 of 5
FORM R4.05-2017 INPUT. SUMMARY:C'HECKLI;
Title:
WYNNE THE GRAND CARLT
Building Type:
User
OwnerName:
WYNNE BUILDING CROP
# of Units:
1
BuilderName:
WYNNE BUILDING COPR.
Permit Office:
ST. LUCIE COUNTY
Jurisdiction:
ST. LUCIE COUNTY
FamilyType:
Single-family.
New/Existing:
New (From Plans)
Comment:
PROJECT
Bedrooms:
2
ConditionedArea:
1446
Total Stories:
1
Worst Case:
Yes
RotateAngle:
180
CrossVentilation: No
Whole House Fan: No
Address Type:
StreetAddress
Lot#
Block/Subdivision:
PlatBook:
Street:
County:
St. Lucie
City, State, Zip:
FT. PIERCE,
FL,
CLIMATE
/ Design Temp Int Design Temp Heating Design DailyTemp
DesignLocation TMY Site 97.5% 2.5% Winter Summer DegreeDays' Moisture Range
FL, Fort Pierce. FL VERO_BEACH^MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area
1 Entire House 1446
Number
Name
Area
1
BEDROOM
301
2
WIC
63
3
M. BATH
56
4
KITCHEN
192
5
BATH
45
6
BEDROOM 2
204
7
ENTRY
55
8
LAUNDRY
42
9
GREAT/DINING
488
FloorType
Space
1 Slab -On -Grade Edge Insulation
BEDR
2Slab-On-Grade Edge Insulation
WI
3Slab-On-Grade Edgelnsulation
M. B
4Slab-On-Grade Edge Insulation.
KITC
5Slab-On-Grade Edge Insulation
BAT
6Slab-On-Grade Edge Insulation
BEDRO
7Slab-On-Grade Edge Insulation
ENT
Volume
11568
ATH
HEN
SPACES
Volume
Kitchen Occupants-
Bedrooms
2408
No 0
1
504
No 0
448
No _ 0
1536
Yes 0
360
No 0
1632
No 0
1
440
No 0
336
No 0
3904
No 0
FLOORS
Perimeter PerimeterR-Value
Area
)OM
' 52 ft 0.
301 ft2 '
C
1 ft . 0
63 ft2
8 ft 0
56 ft2
1 ft 0
192 ft2
H
5 ft 0
45 ft2.
OM 2
32.2 ft 0
203.5 ft2
RY
7 ft 0
55 ft2
Infil ID.
Finished
Cooled
Heated
1
Yes
Yes
Yes
1
No
Yes
Yes
1
Yes
Yes
Yes'
1
No
Yes
Yes
1
Yes
Yes
Yes
1
Yes
Yes
Yes
1
Yes
Yes
Yes
1
Yes
Yes
Yes
1
Yes
Yes
Yes
Joist R-Value
Tile. Wood Carpe
0 1 0
0 1 0
0 1 0
0' 1 0
0 1 0.
0 1 0
0 1 6
1 /8/2020 4:18 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORMR405-2017 INPUT SUMMARY -CHECKLIST REPORT
FLOORS
# FloorType Space " Perimeter �PerimeterR-Value
Area
JoistR-Value
Tile Wood Carpet
8Slab-On-Grade Edge Insulation LAUNDRY 6ft 0
42ft2
_--_
0
1
0
9 Slab -On -Grade Edgelnsulation GREAT/DINING 46 ft 0
488 ft2
-___
0
1
0
ROOF
/ Roof.
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1524ft2
240ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING'
# CeilingType Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic. (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 UnderAttic(Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 UnderAttic(Vented) M. BATH
30
Blown
56 ftz
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192ft2
0.1
Wood
5 UnderAttic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 UnderAttic(.Vented) BEDROOM
30
Blown
204ft2
0.1
Wood
7 UnderAttic (Vented) ENTRY
30
Blown
55'ft2
0.1
Wood
8 UnderAttic(Vented) LAUNDRY
30
Blown
42ft2
0.1
Wood
9 UnderAttic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
10 KneeWall(Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent apace Cavity Width
Et in
Height
Et In
Area
Sheathing Framing Solar Below
R-Nfaiup FmCtoon Ahqor 0
1 NE=>SW Exterior Concrete Block - Iht Insul BEDROOM.
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
_ 2 SW=>NE Exterior Concrete Block - Int Insul BEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
_ .3 NW=>SE Exterior Concrete Block - Int Insul BEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4 SW=>NE Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
_ 5 NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0 '
0
0.4
0
_ 6 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7 SE=>NW Exterior. Concrete Block = Int lnsuBEDROOM2
4.1 10
0 8.
0
80.0ft2
0
0
0.4
0
_ 8 S=>N Exterior Concrete Block - Int InsuBEDROOM 2.
4.1 4
3 8
'0
34.0 ft2
0
0
0.4
0
9 SW=>NE Exterior Concrete Block - Int InsuBEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block- Int Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior. Concrete Block = Int Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12 SW=>NE Exterior Concrete Block- Int Insul LAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 . NE=>SW Exterior Concrete Block - Int lnsul3REAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>$E Exterior. Concrete Block - Int lnsuI3REAT/DINI
4.1 20
0 8
0
160.0ft2
0
0
0.4
0
1/8/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 .INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Space
Height
In Area
Sheathing FramingPt
R-11alue Practim Solar Below
15 N=>S Garage Frame -Wood KITCHEN 11 24 8
192.0 ft2
0.23 0.4
0
DOORS
# Ornt
DoorType Space Storms
U-Value
Ft
Width Height
In Ft In
Area
1 SE=>NW
Insulated ENTRY None
.39 3
1 6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation =>) changed to Worst Case.
Wall
Ornt ID Frame
Panes NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation IntShade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-ESingle Yes 1.04 0.29 Y
Low-ESingle Yes 1.04 0.29 Y
Low-ESingle Yes 1.04 0.29 Y
Low-ESingle Yes 1.04 0.29 Y
Low-ESingle Yes 1.11 0.27 Y
32.9 ft2' 1 ft 0 in
6.9 ft2 1 ft 0 in
24.0 ft2 6 ft 0 in
37.5 ft2 1 ft 0 in
40.0 ft2 8 ft 0 in
1 ft 5 in Drapes/blinds
1 ft 5 in None
1 ft5 in None
1 ft 5 in None
1 ft 5 in Drapes/blinds
Exteriors
None
None
None
Exterior5
GARAGE
# FloorArea
CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 315ft2
315ft2 24ft
INFILTRATION
8ft
11
# Scope Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse ProposedACH(50) .000356 1349.6 74.09 139.34 .1233
7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split. Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 CentralUnit/
Split Single SEER:15
34.8 kBtu/hr
cfm 0.8 1
sys#1
HOT WATER SYSTEM .
# System Type
SubTpe Location EF Cap
Use SetPnt
Conservation
1 Electric
None Garage 0.97 40 gal 60.9 gal 120 deg
None
1/8/2020 4:18 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Editiorr(2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # ' CompanyName
System Model# CollectorModel#
Area Volume.
FEF
None None
ft2
DUCTS
- Supply--
—
Return —
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area
LeakageType
Handler
TOT OUT QN RLF
Heat Cool
1 Attic
6 175 ft2
Attic
65 ft2
DefaultLeakage
Attic
(Default) c(Default) c
1 1
'TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinHJan H Feb'
Mar
� Mar
Apr
Apr
f
May
May�.Jun�
Jun Jul
Jul
AuSep
rjAugSe
Oct HNov
Oct Nov
W
Dec
H Dec
Ventin Jan [)Feb
X Mar
[X] A r
[
Ma
Jun Jul
Aug
Se Oct :Nov.
Dec
ThermostatSchedule: HERS.2006Reference
Hours
ScheduleType
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78'
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
_
78 78
78
78
Heating (WD) AM
66
66
.66
66
66 68
68
68
68 68
68:
68
PM
68
68
68
68
68 68
68
68
-68 68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM.
68
68
68
68.
.68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8lbs/sq.fL
0 ft2
0 ft
0.3
BEDROOM
Default(81bs/sq.ft.
ft2
ft.
0.3
WIC
Default(8lbs/sq.ft.
ft2.
ft
0.3
M: BATH
Default(81bs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default 8lbs/s .ft.
ft2.
ft
.0.3..
GREAT/DINING
1/8/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev: 1) - FlaRes2017 FBC 6th Edition-(2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
uu
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities'within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity g g insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts,. penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated. .
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Pytpnfi behind piping and wir'ng.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall .
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
be.tween.fire.spripider cover plates and molls orce*lings.
a. in addition, inspection of log walls shall oe In accordance with the provisions of IGG-4uu.
1/8/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy
Performance Index,
the more 'efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (insulation R-value)
10A2.
4.1
i Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded). in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Homer oys"�L s mTz s\r-� 5 City/FL Zip: FT. PIERCE. FL �4
1/8/2020 4:19:34 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1