Loading...
HomeMy WebLinkAboutConstruction PlansXNC. I t R i r(f`..z - 10-25-19 M. Randall Rodgers, P.E. FL Lic. No. 68212 " 1801 Hazelwood Drive Ft. Pierce, FL 34982 PH: (772) 201-1634 - �r E ,0..,. a ��+�'- �{�„fi`'i}�.4 �� s4 �" iN., rt" k r!-2 tr' � �:.;j : `�'•- ,,.z asn^�i � x k.� . r a _ TO CODE + I2" 24" SHEER DESCENT 0IF log DEPTH W 114 1 s' tifcy „ V It \CP ;X d BUBBLER o „aS 321111 6 32' 1" DECK SQFT: 663 SHEER DESCENT LINE 2" RETURN LINE 2.5" MAIN DRAIN LINE 2.5" —, VACUUM LINE 2" 1' DEPTH T 6" X 3' STEP TILE "M M g•— LE *A 7 REVIEWED FOR CODE CON IPLIANCE: ST. LUCIE' � Tj�, BO( t I have reviewed and I give my approval to prodlied with the construction of this project. x Customer Date 5 AX WIDTH: 14" 4" MAX LENGTH: 28' DEPTH; 3' 6" TO 4' 11" PERIMETER: 73' SHAPE: ALLEGRO SQUARE FEET: 331 DIRT FROM EXCAVATION: HAUL LEAVE: NO LEAVE & SPREAD: NO LEAVE -MOVE -THEN SPREAD NO EXTRA FILL & COMPACTION NO JOB ENTRANCE: FAR LEFT SIDE OF LOT THROUGH GATE 6 X 6 TILE: AY-623 ALEXANDRIA INT FINISH: BLUE GEM STEP TILE: AY323 DIAMONED ON STEPS FILTER: CLEAN & CLEAR 100 PUMP: SUPERFLO VS 0.10TOR H.P. 1.5 HP TIME CLOCK: IN PUMP CHLORINATOR: ICHLOR 30 LIGHTS 2 GLOBRITES IN THE POOL TRANSFORMERS 1 DOOL CLEANER: DORADO VAC LINE 1 MAIN DRAIN: 32" CHANNEL SKIMMERS: 1 RETURNS: 4 SWIMOUT OR LADDER: NONE 4' 11" HANDRAIL: NONE FILL LINE: NONE OVERl;i e !.INE: NONE SPA SPECS: NONE SPA PUMP:- NONE SLIDE: NONE HEATER: NONE TANK: N/A VAC. HEAD: N/A VAC. HOSE 1 VAC POLE: 1 BRUSH: 1 LEAF SKIMMER: 1 TEST KIT: 1 n FRFLOW LINE: FILL LINE: NONE RE REMOVAL: STUMP REMOVAL: NONE WATER & ELECTRICAL SUPPLY: REAR OF HOUSE ELECTRICAL HOOKUP: PAYUK LEFT SIDE OF HOME BACKWASH LINE: STD BLUE FLAT LINE PATIO: 663 SQFT FLO-CRETE COLOR: SANDSTONE EXISTING PATIO. 385 SOFT GRIND & TOP TERMITE: STD DECO -DRAIN: WHITE FOOTERS: STD PLANTERS: NONE OVERPOUR: YES SCREEN ENCLOSURE: NATHAN WYATT "BRONZE" SAFETY FENCE COLOR: BLACK ON BLACK CUT & CAP SPRINKLERS: NONE, ABANDONED PIPES ONLY APPROX GALLONS: 9950 PUMP G.P.M. SEE ATTACHED SOLAR BY: NONE YES NO 6" X 6" X SHEET TILL: ®X_ OVERPOUR X MOSAICS X— Meaner: R08ERT WOOD Address: 8886 S FEDERAL HWY C-' a PORT ST LUCIE FL 34982 One: 772-337-9713 ext 20 Cell: 772-631-3948 _ Email: robertbwood@atlr.net T License #: CPC 1458338 Name: CHRISTOPHER E N': SE Address: 2453 JOHNSTON RO City: FT PIERCE FL 34951 Cell: 772-284-4434 Email: caver111469@gmaii.com —Pool construction complies with FBC 2017 ANSI-7. ANSI-15 WHEN PROVIIDED SHALL BE AT 20" MAX BELOW THE WATERLINE SWIMOUTS (NO SCALE) A N Vacuum (In Hg) X 1.13 Feet Of Head 1LWj11HI1L,,10iLW1,A MAIN DRAIN POOL DETAIL (NU SCALE) rnirsff M61E OF REPOSE 6• AND RRI ER - 4' THICK WAILS W/#3 REBAR 012' O.C. EACH WAY 3• To V - 6- THICI( WALLS W/13 RO Ni 012- O.C. EACH WAY 0• TO 3• - 8' Dora( %WLS W/j3 REBAR 012. O.C. EACH WAY ," m A` Pressure (PSI) X 2.31 Feet Of Head Vacuum Head + Pressure Head = Total Dynamic Head fB COPPER ' VERTICAL INSTALL PoolBond PB-2008 Instal in Plumbing T at least 3' Below Water level in Return PiipingAnstall in sprinkler box for easy access HATER BOND DETAILS FOR 3 3 5� WAVATION MID THE ANLxE OF REPOSE IS ALLOWABLE PROVDED: SFKNING IS INSTALLED AT EXCAVATION ALA SHORING SHOULD BE FENT TO SECURE SOILS FROM N OMPROVEDD IF �I r• f •SNNOOC1NDER OCCURS OCCIENGINEER DOES " •' • COLPACRON TESL OF 11E BAaftLED MATERIAL ARE PROVIDED '.. PRIOR TO THE PoUMIE OF THE PATIO MISC. TES 1. ALL STEPS AND SWMOm RENCH OM WEL HAVE 2x6 CAPIEE BORDER OF OPPOSITE COLOR OF GEM 1Wu1T FOR VMUTY 2. HANIOLD TO BE NSTALIED ARE WHERE DECK RASED +6' ABOVE POOL STOS !(Qt7E; REMOVE GRATE a YIDL PONT n1A FROM MAIN fACW�011R OIUN a ATTACH NIX. PUMP LEE WHEN EPMNG POOL 6 x6 GRATE SHALL BE SECURED IN IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL r PER FL µN SLOPE CAP ME TILL 4' SLAB TERIOR 2500 FIBER MIX FINISH 4h- TYP. WALL-3,000 PSI GUNRE ..' STEEL-TEX FORM OR KRAFT WALL 6• TYP. FLOOR . TRENCH ORATI 3,000 PSI 13 • 12- O.C.B.W. GUNITE - NOTE: FOR DEPTHS t GREATER THAN 6• ADD TREADED PLUG i , ` (1)13 COVE BAR 06' O.C. GRAVEN. B TO PUMP TYP. WALL SECTION & WELL POINT WATER LEVEL (NO SCALE) • •N E EXISTING GRADE OR 1 • TO 4 SLOPE (1) #5 REBAR POOL PERIMETER OR (2) #3 REBAR RAISED AREA ELEV. & GRADE (NO SCALE) POOL PATIO " 12 VAC FROM .`3.: ? POWER SUPPLY `•.' SIZE AS DETERMINED z d- =•u x BY LICENSED ELECTRICIAN UNDERWATER•';, LIGHT:- `— 1' PVC POOL FINISH - CONDUIT STEP DETAILS >. t. TAOID IS MN OF IV WIDE SCHEDULE 40 PVC SLEEVE 2. RISER NOT GREATER THAN 12' OLCEPT IF s== MORE THAN (3) TREADS ARE USED - z• NO BONDING 3. ALL STEPS TO DE SOLID GUNRE 3000 P.S.I. OR GROUND REWIRED NICHLESS UNDERWATER LIGHT DETAIL Na SCALE) 11 cwnN (2) #3 REBAR OR (1) #5 REBAR N• FOOTER DETAIL (NO SCALE) PIPING SCHEMATIC CUSTOM MOLDED PRODUCTS INC. POOLS by _ .ARE HNC DECK 1 ROW OF WA70dRE TEE WATERLINE - HAIR a I INEH MAz t ,,,�, ,,,,,.• —11 +3 STEEL W 12. O/C EW. 5wa�MI CMP 25506-32X VGB PER 1RC4501.G6 COMPLIANT 32' CHANNEL DRAIN OOMPtANT wlm 2017 FLORIDA BUILDING CODE USED 10 ASMIEJANSI A1121g.8 32' CHANNEL DRAIN AND SUMP 25506-320-000 *THREE 2• SOCKET x 2.5' SPIGOT PORTS *DEBRIS GUARD INCLUDED *38.79in? OPEN AREA %ft LISTED ROW RATES *WHITE PVC BODY 'COVER GOES OVER BODY TO GIVE FINISHED LOOK To Pule The maximum flow rating for this suction fitting with the center port plugged and outer parts open is 308 GPM (floor) and 212 GPM (wall) when using 2.5' plumbing and 268 GPM (floor) and 192 GPM (wall) when using 2' plumbing. The maximum flow rating for this suction fitting with the outer ports plugged and the center port open is 200 GPM (floor) and 168 GPM (well) when using 2.5• plumbing end 184 GPM (floor) and 176 GPM (wall) when using 27 plumbing. RETURN TO POOL THREE-WAY WATER TO SHEER VALVE DESCENT d -- - - FlLTER SUCTION FROM POOL TYPICAL SHEER DESCENT DETAIL CHU SCALE) CODE ST. LI B• THICK TYPICAL SECTION THRU POOL (No SCALE) Pipe Size 6 fps 8fps 1' 16 gprl 0.14' 21 gpm 6.23' 1,5' 37 gpm 0,08' ` 50 gpm 0.14' 2- 62 gpm 0.06' 82 0,10' 2.5' 88 gpm 0.05' 117 gpm 0.09' 3' 136 gpm 0.04' 181 gpm 0.07' 4' 234 1534 gpm 0.03' 313', gpm 0.05' 6' gpm 0.02' 712 gpm 0.03' Determine System now Rate: Minimum Flow Rate Required: 35 gpm per skimmer 1. Calculate Pool Volume: X)(X ft X)-(X- x 7.48(gal/Ft) = XXX of (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: XXX gal / XXX = XXX + XXX = XXX (Volume) (Turnover Minutes) (Pool Row Rate) (Feature Flow Rate) (System Flow Rate) Determine Pipe Sizes: Trunk Piping to be 2.5 inch to keep velocity • 8 fps max. at 117 gpm Maximum System Flow Rate. Return Piping to be 2.5 inch to keep velocity 0 8 fps max. aL 117 gpm Maximum System Flow Rate. Main Drain Cover(_ SEE ABOVE ) System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Drain Configuration Pump Model PENTAIR SUPERFLO VS H.P. 1.5 Total H.P: H.P.xsMIoa Miar.1114iormonandbe2spesdarvariahlespead Flier Make PENTAIR C&C Size 100 Filter min, arm based on 81v. bmmovwrlaw rite pod gai 1380 free. =1TmzRate Divide G.P.M. by Cartridge =.375 or Sand =15 a D.E. = 2 Time Controller make ON PUMP Model ------ ® ConnisaxstopeafeamminmmdMvspeeds EWED FOFI I The overrides ndtoon e e normal cydaar24 Irswidceffa less ;OMPLIANCE CIE COUNTY BOCC DESIGNED FOR: POOLS BY GREG AVERILL RESIDENCE 2453 JOHNSTON RD FT PIERCE, FL 11111111111, ,Op,LL RC ;"YBENS 1801 Rauh * Pi7g c77re77��e77, 0, FTATE(O ;0". LoR1D ***ELECTRIC NOT TNCI PREPABFDBY: STEVE HORST DRAFTING & 3 , PENTAIR TDH CALCULATOR Pool Information PBG-AVERILL-HIGH SPEED Flow Rate: 88.12 GPM Total Piping Lengths: Suction Lift 2 Ft Inlet Side: 52 Ft Discharge Side: 122 Ft Maximum Pipe Velocity Allowed: Piping Sizes: (consult your local code) Inlet Piping: 2.4451n p g Inlet Pi Piping: 8 FVSec Discharge Piping: 2.445 In Discharge Piping: 8 Ft/Sec i Piping Head Loss at 88.12 Gal/Min- (not incuding fittings or valves) Inlet Piping: 2.55 Ft Discharge Piping: 5.97 Ft For advanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer This program is for single pump sytems with a single body of water. Results: Your TDH Calculation Required Minimum Pipe Sizes: Flow Rate: 88.12 Gal/Min Inlet Piping: 2 5 In Your Head Loss: 34.77 Ft Discharge Piping: 2.5 In Maximum Flow Rate at Maximum RPM: 89.12 Gal/Min Ensure the drain cover max flow rating is not exceeded. Head Loss at Maximum Flow Rate: 34.78 Ft System Head Pressure Curve 70 60 50 O_ z 40 a 30 20 10 O 0 25 50 Volun Selected Components Components ru. as Sia53�a)vyw ka� anus Piping tl.ry m e.y»euw asa�eeeew 1ttlNay� Pumps tr. swrcvs se Lens r ae.a.lx sarael 1 1 2e 5R 1 1 142 1 s.al ye.1 oiwyr H.aelms• Quwniy are.l3a 0 3 6 ,o C 0 3 C. 0 5 tP a`-rr 1 coke. R�Ry,RinrPa�wMla'eM.v. S V perFlo VS - 3450 rpm Clean System Desired Operation Point 75 100 125 fM ex^m Me PENTAIR TDH CALCULATOR Pool Information PBG-AVERH.L-LOW SPEED Pool Volume: 9950 Gal Total Piping Lengths: Tom Over Time: 4.50 His Inlet Side: 52 Ft Suction Lilt: 2 Ft Discharge Side: 122 Ft Maximum Pipe Velocity Allowed: Piping Sizes: (consult your local code) Inlet Piping: 2.4451n Inlet Piping: 8 FVSec Discharge Piping: 2.445 In Discharge Piping: 8 FVSec Piping Head Loss at 36.85 Gal/Min: (not incuding fittings or valves) Inlet Piping: 0.51 Ft Discharge Piping: 1.19 Ft For advanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer. This program is for single pump sytemz with a single body of water. Results: Your TDH Calculation Required Minimum Pipe Sizes: Flow Rate: 36.85 Gal/Min Inlet Piping: 1.5 In Your Heath Loss: 7.97 Ft Discharge Piping: 1.5 In Maximum Flow Rate at Maximum RPM: 88.12 Gal/Min Ensure the drain cover max flow rating Is not exceeded. Head Loss at Maximum Flow Rate- 34.78 Ft }} SysterA Head Pressure Curvo O 10 20 30 40 50 Volumetric Flow Rate (GPM) Selected Components components oesat zazsawrre taanoual ar.,eea� Piping atsa. 90CyeBc40x CSeeaeprLwi T®Tl.grf Pumps xane syAn. vs x U,md o.ry aaaerarn t nta e na t as t nm rr a., er d rrr ee+r arxerrn 1 a Le 1 a QOt a s ax agar t s:7 A:.E-sake- sauweas:.wsawoanw sib vveaM an grMsn u n DESIGNED FOR: tip 84f�g z _p �.�yStj pp� Me i 0 0 &� PO o U all o g"Xiat1 gP, z ez 09 F �� O 0. Lij J s a Zp fai Hm5 00 Mq g�'g ef-0 $9 or. w �� pz j9j �$W Nx c+z •�, NP9� aIGy O .x 60a .if myy�n V W �F 'Doe o U �o y o w Si 1W 6i Cl ro z POOLS BY GREG AVERILL RESIDENCE 2453 JOHNSTON RD FF PIERCE, FL REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY ROCC P��ttOpLl. R Q-PN�CEN, 1$�! Hmly Piefce, ***ELECTRIC NOT INQ PREPARED BY: STEVE HORST DRAFTING & DESIGN SERVICES M2)201.7M6 hmsL*ve@yaha X3