Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL, 5VEVALUATION REPORT OF UNION CORRUGATING COMPANY `26 GA. 5V PANEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 7271.2-R4 ROOFING METAL ROOFING Prepared For: Union Corrugating Company 701 S. King St. Fayetteville, NC 28301 Telephone: (910) 483-0479 Fax: (910)483-1091 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa., OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (I Page) Report No. C2174-2 Date: 8.23.2017 FL 7271,2-R4 C2174-2 8.23.2017 Manufacturer: Union Corrugating Company Page 2 of 3 Product Name: 5V Panel Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: -Min. J 5/32"LWck AP.4,raled p)y1voadOrwin.:4" thkk woodplar� �m n SG of 0.42) for never and existing constructions. Designed by others and installed as per FBC 2017. Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1 Slope: 1/2:12 or greater in accordance with. FBC 2017 Section 1507A-2 Design Uplift Pressure: 66.3 psf @ fastener spacing of 12" ox, (Factor of Safety = 2) Panel Attachment: 49-15 or #10-14 x Iong wood screw with washer. Fastener shall be of At panel ends sufficient length to penetrate through the deck a minimum of 3/8" At intermediate @ max 6" o.c. across panel width @ max 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with UL580-94 'Uplift Resistance of Roof Assemblies' & UL1897-98 `Uplift Tests for Roof Covering Systems'. Test Equivalency: The test procedures in UL 580-94 comply with test procedures prescribed in UL 580-06_ 'T)ae test procedures in -u—L 1897-9S comply with test procedures prescribed in UL I897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 20I7 Section 1505 and current approved roofing materials directory or ASTM E1081UL790 report from an accredited Iaboratory for fire ratings of this product. Supporting Documents: UL580/UL1897 Test Report Farabaugh Engineering and Testing Inc. Project No. T187-06, Reporting Date 7/25/06 FL 7271.2-R4 C2174-2 8.23.2017 Page 3 of 3 - ulwmv 5� L-65Y v, 1gr�5 miw +m1-cn ici4 a, wu-nr ow , mm ZH i111 71myi _ 3ivo yryx 3HON IS `UNIX HLi19S 3n[ l� Z a sx ht Ll�ii�dI1TO � � IMaNN4) AIR LLJ 7 CD o_ (10 LJJ Z T n^ vn /V� J VJ Ld t �O W LLJ zLli V o zz. �� �l Cis LiUz N Q _j m Q a �_ a U o � 0 � � w _o _Q Q Y w — o W 0 cc i W } E � E z � w `n iW a- Q W � z w w z c Q L LLJ < �I l C Ii O W G] LLJ p Z f W �Z�� [r LLJo I—Lj LLJ am F W LLJ QC) V) �CrCCT LL. � < � (n < , <D,o_ ��