Loading...
HomeMy WebLinkAboutProduct Approval 1213/2020" Florida Building Code Online Business & Professional - Regulation BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge I Stats R Facts Publications Contact Us BCIS Site Map I Links I Search ta P 'r " Product Approval ni USER:Public User (j r ( Product Aporoval Menu>Product or Application Search>Application List>Application Detail qwo Z ? •Ark FL# FL13223-R REVIEWED FO H Application Type Code Version 2017 CODE COMPLIANCE Application Status Approved STo LUCIE COUNTY Comments BOCC i-� �s Archived Product Manufacturer James Hardie Building Products,Inc. y Address/Phone/Email 26300 La Alameda Ste.250 Mission Viejo, 92691 F''e Copy. (909)545-8359 l� chad.diercks@jameshardie.com Authorized Signature Chad Diercks chad.diercks@jameshardie.com Technical Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana,CA 92337 (909)349-2927 pingsheng.zhu@jameshardie.com Quality Assurance Representative Pingsheng Zhu Address/Phone/Email 10901 Elm Ave. Fontana,CA 92337 (909)349-2927 pingsheng.zhu@jameshardie.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 17— Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Ronald I.Ogawa Evaluation Report Florida License PE-24121 Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By John Southard,P.E. W Validation Checklist-Hardcopy Received Certificate of Independence FL13223 R4 COI RIO-Certificate of Indeoendence.ndf Referenced Standard and Year(of Standard) Standard Year ASTM C1186 2007 ASTM E330 2002 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL13223 R4 Eauiv RIO-2692B-17 ASTM C1186 eauivalencv.Ddf https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvRk6bsvZ66FCwkdpAghfYHNfydCyTGMPIGgZQlQyBy7Qp/*3d°/*3d 1/3 1213/2020' Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/09/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL# Model,Number or Name Description 13223.1 Cempanel Siding fiber-cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL13223 R4 II cempanel-installation.Ddf Approved for use outside HVHZ:Yes FL13223 R4 II NOA 17-0406.06.pdf Impact Resistant:Yes FL13223 R4 II RIO 2689-17 Panel to Furring.Ddf Design Pressure:N/A FL13223 R4 II RIO-2686-17 Panel Wood Metal Frame.pdf Other:For use inside a HVHZ install in accordance with NOA Verified By: Ronald I.Ogawa 24121 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.pdf FL13223 R4 AE RIO 2689-17 Panel to Furring odf FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.pdf Created by Independent Third Party:Yes 13223.2 HardiePanel Siding fiber-cement panel siding of Use Installation Instructions Approved for use In HVHZ:Yes F1,33223 R4 II HardiePanel-Installation.Ddf Approved for use outside HVHZ:Yes FL13223 R4 II NOA 17-0406.06.Ddf Impact Resistant:Yes FL13223 R4 II RIO 2689-17 Panel to Furrino.pdf Design Pressure:N/A FL13223 R4 II RIO-2686-17 Panel Wood Metal Frame.pdf Other:For use inside a HVHZ install in accordance with NOA Verified By: Ronald I.Ogawa 24121 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.pdf FL13223 114 AE RIO 2689-17 Panel to Furring.Ddf FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.pdf Created by Independent Third Party:Yes 13223.3 Prevail Panel Siding fiber-cement panel siding Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL13223 R4 II NOA 17-0406.06.Ddf Approved for use outside HVHZ:Yes FL13223 R4 II Prevail-Panel-In staIlation.pdf Impact Resistant:N/A FL13223 R4 II RIO 2689-17 Panel to Furrino.Ddf Design Pressure:N/A FL13223 R4 II RIO-2686-17 Panel Wood Metal Frame.odf Other: For use inside a HVHZ install in accordance with NOA Verified By: Ronald I.Ogawa 24121 17-0406.06 Created by Independent Third Party: No Evaluation Reports FL13223 R4 AE NOA 17-0406.06.Ddf FL13223 R4 AE RIO 2689-17 Panel to Furring.Ddf FL13223 R4 AE RIO-2686-17 Panel Wood Metal Frame.pdf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee Fl,32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: w� � eCheck hftps:/Avww.floridabuilding.org/pr/pr app_ U.aspx?param=wGEVXQwtDgvRk6bsvZ66FcwkdpAghfYHNfydCyTGMP[GgZQ1QyBy7Q%3d%3d 213 Hardie Panel /� �o Vertical Siding JamesHardie �' 9 EFFECTIVE APRIL 2009 OW INSTALLATION REQUIREMENTS- PRIMED&COLORPLUS@ PRODUCTS Visit www.jameshardie.com for the most recent version, SMOOTH • CEDARMILL° • SELECT SIERRA 8 • STUCCO IMPORTANT:FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY,AFFECT SYSTEM PERFORMANCE,VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY.BEFORE INSTALLATION,CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE INSTRUCTIONS. INSTALLATION OF HZ10TM PRODUCTS OUTSIDE AN HZ10Tm LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONE APPLIES TO YOUR LOCATION,VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343(866 9HARDIE) STORAGE & HANDLING: © CUTTING INSTRUCTIONS Store flat and keep dry and OUTDOORS INDOORS covered prior to installation,Installing 1.Position cutting station so that wind will blow dust away from user 1.Cut only using score and snap,or shears(manual,electric or pneumatic). and others in working area. 2.Position cutting station in well-ventilated area siding wet or saturated may result in 2.Use one of the following methods: shrinkage at butt joints.Carry product a.Best I.Swre and snap ii.Shears(manual,electric or pneumatic) -NEVER use a power saw indoors on edge. Protect edges and corners b.Better: I.Dust reducing circular saw equipped with a -NEVER use a circular saw blade that does not carry the HardieBlade saw blade trademark from breakage.James Hardie is not HardieBlade9 saw blade and HEPA vacuum extraction NEVER dry sweep—Use wet suppression or HERA Vacuum responsible for c.Good: i.Dust reducing circular saw with a HardieBlade saw blade res P (only use for low to moderate cutting) damage Caused Important Note:For maximum protection owest respirable dust production),James Hardie recommends alwaysusing Best"-level cuttin methods where feasible. by improper P � p p ) g g Storage and NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures.Additional exposure information is available at wwwjameshardie.com to help you determine the most appropriate cutting method for yourjob requirements.If concern still exists about exposure levels or you handling of the product, do not comply with the above practices,you should always consult a qualified industrial hygienist or contact James Hardie for further information. M083105 GENERAL REQUIREMENTS: • HardiePanel®vertical siding can be installed over braced wood or steel studs spaced a maximum of 24"D.C.Irregularities in framing and sheathing can mirror through the finished application. • HardiePanel vertical siding can also be installed over foam insulation/sheathing up to 1"thick.When using foam insulation/sheathing,avoid over-driving nails (fasteners),which can result in dimpling of the siding due to the compressible nature of the foam insulation/sheathing.Extra caution is necessary if power-driven nails (fasteners)are used for attaching siding over foam insulation/sheathing. • A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements.James Hardie will assume no responsibility for water infiltration.James Hardie does manufacture HardieWrapTM Weather Barrier,a non-woven non-perforated housewrapl,which complies with building code requirements. • When installing James Hardie products all clearance details in figs,5,6,7,8,9,10&11 must be followed. • Adjacent finished grade must slope away from the building in accordance with local building codes-typically a minimum of 6"in the first 10'. • Do not install James Hardie products,such that they may remain in contact with standing water. • HardiePanel vertical siding may be installed on vertical wall applications only. • For larger projects,including commercial and multi-family projects,where the span of the wall is significant in length,the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design.These values can be found in the Technical Bulletin"Expansion Characteristics of James Hardie®Siding Products"at www.JamesHardie,com. • DO NOT use stain on James Hardie®products. INSTALLATION: Fastener Requirements Joint Treatment Position fasteners 3/8"from panel edges and no closer than • Vertical Joints-Install panels in moderate contact(fig.1),alternatively 2"away from corners.Do not nail into corners. joints may also be covered with battens,PVC or metal jointers or HardiePanel Vertical Siding Installation caulked(Not applicable to ColorPlus®Finish)(fig.2). • Framing must be provided at horizontal and vertical edges for nailing. • Horizontal Joints-Provide Z-flashing at all horizontal joints(fig.3). • HardiePanel vertical siding must be joined on stud. Figure 2 Figure 3 • Double stud may be required to maintain minimum edge water-resistive barrier water-resistive barrier nailing distances. 2 4 stud 2 x 4 stud water-resistive water-resistive barrier barrier Figure 1 -- —upper panel f—upper panel stud / r water-resistive I Do not 1/4"gap Do not 114"gap barrier Caulk Caulk sheathing HardiePanel Batten Joint "H"Joint ~Z-flashing Z-flashing 0 o vertical siding water-resistive barrier decorative keep nails 2 x 4 stud —lower ~band board 3/8'min. panel f—lower from panel panel edges plate ° Figure 4 319" leave appropriate gap between Recommendation:When r — of L panels,then caulk* installing Siena 8,provide ° Caulk Joint a double stud at panel moderate contact (Not applicable to ColorPlus®Finish) joints to avoid nailing keep fasteners 2" 'Apply caulk in accordance with caulk through grooves. nu away from corners manufacturer's written application instructions. 'For additional information on HardieWra rm Weather Barrier,consult James Hardie at 1-8664Hardie or www.hardiewrap.com WARNING:AVOID BREATHING SILICA DUST James Hardie®products contain respirable crystalline silica,which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause of cancer from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis,and has been linked with other diseases.Some studies suggest smoking may increase these risks. During installation or handling:(1)work in outdoor areas with ample ventilation;(2)use fiber cement shears for cutting or,where not feasible,use a HardieBlade°saw blade and dust-reducing circular saw attached to a HEPA vacuum;(3)warn others in the immediate area;(4)wear a properly-fitted,NIOSH-approved dust mask or respirator(e.g.N-95)in accordance with applicable government regulations and manufacturer instructions to further limit respirable silica exposures. During clean-up,use HEPA vacuums or wet cleanup methods-never dry sweep. For further information,refer to our installation instructions and Material Safety Data Sheet available at www.jameshardie.com or by calling 1-800-9HARDIE(1-800-942-7343). FAILURE TO ADHERE TO OUR WARNINGS,MSDS,AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH. soasaeos HS0919-P112 3110 CLEARANCES Install siding and trim products in compliance Maintain a 1" 2" Maintain a 1"-2"clearance between At the juncture of the roof and vertical with local building code requirements for clearance between James James Hardie products and decking surfaces,flashing and counterflashing shall clearance between the bottom edge of the Hardie'products and paths, material. be installed per the roofing manufacturer's siding and the adjacent finished grade. steps and driveways. Figure 7 instructions.Provide a 1"-2"clearance stud between the roofing and the bottom edge siding water of the siding and trim. siding Figure 6 g resistive r1%2" �►r barrier deck material Figure 5 I Figure ure 8 1„ 211 1 bottom 0 = ° f plate f I i l joist flashing } ledger 4 concrete 6"min. foundation hashing T� Figure 11 KICKOUT FLASHING Maintain a 1/4"clearance Maintain a minimum 1"gap stepflashing/ / Because of the volume of water that can pour down between the bottom of James between gutter end caps and Smemb erin ; / a sloped roof,one of the most critical flashing Hardie products and horizontal siding&trim. '. details occurs where a roof intersects a sidewall. flashing.Do not caulk gap. self-adherin J 1 The roof must be flashed with step flashing. Where eaves membrane` Figure 10 � kldkeut the roof terminates,install a kickout to deflect water flashing away from the siding. Figure 9 Drip edge . *—siding { '� It is best to install a self adhering membrane on the va"gap siding i %" ousewrap wall before the subfascia and trim boards are nailed in place,and then come back to install the kickout. t < . fasciaFigure 11,Kickout Flashing$To prevent water from dumping behind the siding and the ing ,I:if' end of the roof intersection,install a"kickout"of sufficient length and angle to direct the gutter and end cap water running down the roof away from the siding. GENERAL FASTENING REQUIREMENTS • Consult applicable code compliance report for correct fasteners type and Fasteners must be corrosion resistant,galvanized,or stainless steel. placement to achieve specified design wind loads. Electro-galvanized are acceptable but may exhibit premature corrosion, • NOTE:Published wind loads may not be applicable to all areas where James Hardie recommends the use of quality,hot-dipped galvanized Local Building Codes have specific jurisdiction.Consult James Hardie nails. James Hardie is not responsible for the corrosion resistance of Technical Services if you are unsure of applicable compliance documentation, fasteners. Stainless steel fasteners are recommended when installing 9 Drive fasteners perpendicular to siding and framing. Fastener heads should fit snug against siding(no air space).(fig.A) James Hardie®products near the ocean,large bodies of water,or in • Do not over-drive nail heads or drive nails at an angle. very humid climates. • If nail is countersunk,caulk nail hole and add a nail.(fig.B) PNEUMATIC FASTENING • For wood framing,under driven nails should be hit flush to the plank with a James Hardie products can be hand nailed or fastened with a pneumatic tool, hammer(For steel framing,remove and replace nail). Pneumatic fastening is highly recommended, Set air pressure so that the Da not use aluminum fasteners,staples,or clipped head nails. fastener is driven snug with the surface of the siding.A flush mount Snug Flush attachment on the pneumatic tool is recommended. This will help control the Countersunk, depth the nail is driven.If setting the nail depth proves difficult,choose a ® add nail Caulk& ® liIIIII 0 setting that under drives the nail. (Drive under driven nails snug with a do not under oo NOT smooth faced hammer-Does not apply for installation to steel framing), Figure A Figure B drive nails STAPLE CAULKING PAINTING For best results use an Elastomeric Joint Sealant complying DO NOT use stain on James Hardie®products.James Hardie products must be with ASTM C920 Grade NS,Class 25 or higher or a Latex painted within 180 days for primed product and 90 days for unprimed. Joint Sealant complying with ASTM C834.Caulking/Sealant 100%acrylic topcoats are recommended.Do not paint when wet.For application must be applied in accordance with the caulking/sealant rates refer to paint manufacturers specifications.Back-rolling is recommended if manufacturer's written instructions or ASTM C1193. the siding is sprayed, *The illustration(figure 11)was reprinted with permission of THE JOURNAL OF LIGHT CONSTRUCTION.For subscription information,visit www.jlconline.com. RECOGNITION: In accordance with ICC-ES Legacy Report NER-405,HardiePanele vertical siding is recognized as a suitable alternate to that specified in:the BOCA National Building Code/1999,the 1997 Standard Building Code,the 1997 Uniform Building Code,the 1998 International One-and Two-Family Dwelling Code,the 2003 International Building Code,and the 2003 International Residential[Code for One-and Two-Family Dwellings. HardiePanel vertical siding is also recognized for application in the following: City of Los Angeles Research Report No.24862,State of Florida listing FL#889,Dade County,Florida NOA No.02-0729.02,U.S. Dept of HUD Materials Release 1263c,Texas Department of Insurance Product Evaluation EC-23,City of New York MEA 223-93-M,and California DSA PA-019.These documents should also be consulted for additional information concerning the suitability of this product for specific applications. ©2010 James Hardie Technology Limited.All rights reserved. TM,SM,and 0 denote trademarks or registered trademarks of Additional Installation Information, James Hardie Technology Limited.C7 is a registered Warranties,and Warnings are available at titJamesHardie trademark of James Hardie Technology Limited. www.jameshardie.com / HS0919-P212 3/10 Florida Product Approval HardiePanel° Siding • For use inside HVHZ: o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami-Dade County Florida NOA 07- 0418.04. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements. • For use outside of HVHZ, o HardiePanel Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Report RIO-2297-11. Consult the HardiePanel product installation instructions on the follow pages for all other installation requirements.