HomeMy WebLinkAboutEnergy CodeFORM R40572017
'FLORIDA ENERGYEFFICIENCYCODE FOR, BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance. Method
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
Street: �r2�
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, IFL ,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9., Wall Types.(1432.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a, Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms3
d. N/A
R= ft2
5. Is this a worst case? Yes
10.,Ceiling, Types (1783.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0. 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts' .
R ft2
7: Windows(151.4 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
A. U-Factor: Sgl, U=1.04 111.36 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency, .
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15:00
c. U-Factor: N/A ft2
SHGC;
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC: .
Area Weighted Average:Overhang Depth: 2:850 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems"
8. Floor Types (1753.0 sgft.) Insulation Area
a. Electric
'Cap: 40.gallons
a. Slab -On -Grade Edge Insulation R=0.0 1153.00 ft2.
b. Conservation features
EF:0.970
b. N/A R= ft2 •
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 52.20
Glass/Floor Area: 0.086
PASS
`7
Total Baseline Loads: 53.92
I. hereby certify that the plans and -specifications covered by
Review of the plans and
-ip
this calculation are in compliance with the Florida Energy
specifications covered by this
_
`'' ",�►
Code.
calculation. indicates compliance
,, ^.;�.
0
with the Florida Energy Code.
,
PREPARED BY:
Before construction is completed:
DATE: 1-9-20
this building will be inspected for
compliance with Section 553.908
�.
hereby certify that this building, as designed, is in compliance
: Florida Statutes.
"
with the Florida Energy Code..
'
OWNER/AG T:
BUILDIN I LA
DATE:
DATE:
- Compliance requires certification by the air handlerunit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R46&3.2.1. t,��
- Compliance requires an.Air Barrier and Insulation Inspection Checklist in accordance v @4�1rWFhhAi1Fp jt6t requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R40
ibE O®MPLINC
ST. LUOIE.COUNT.
HOW,
1/8/2020 4:43 PM EnergyGauge® USA 6:0:02.(Rev. 1) - FlaRes2017. FBC, 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms:. 3
Address Type:
Street Address
Puilding Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate An 0
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE.,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort. Pierce FL VERO BEACH_MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name
Area. Volume
1 Entire House
1753 14024
SPACES.
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID'
Finished -Cooled
Heated
1 MASTER BEDROO
224 1792 No 0
1
1
Yes
Yes
Yes
2 WIC
63 504 'No 0
1
No.
Yes
Yes
3 MASTER BATH
56 448 No • 0
1
Yes
Yes
Yes
4 M.BATH
61 488 No 0
1
Yes
Yes
Yes
5 LAUDRY
36 288: No 0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No 0
1
1
Yes
Yes
Yes
7 DINING/GREAT R
588 4704 No 2
1
Yes
Yes
Yes
8 KITCHEN
.209 1672 Yes 0
1
Yes
Yes
Yes
9 BATH
50 400 No 0
1
Yes
Yes
Yes
'10 HALL
25 200 No 0
1
No
Yes
Yes
11 FOYER
92 736 No 0
1
Yes
Yes
Yes '
12 BEDROOM 3
169 1352 No 0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value .
Area
Joist R Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
. MASTER BEDRO .37 ft . 0
224 ftz
_
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 t 0
63 ftz
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH, 8 ft 0
56 ftz
___-
0 1
0
4 Slab -On -Grade Edge Insulatio
M: BATH 7 ft 0
.61 ftZ
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ftz
_
0 1
0
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017. FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT. SUMMARY CHECKLIST REPORT
4
FLOORS
# Floor Type
Space Perimeter PerimeterR-Value
Area
Joist R-Value
Tile Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
0 1 -0
7SIab-On-Grade Edge Insulatio
DINING/GREAT 50 ft
0
588'ft2
0 1 0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift
0
209 ft2'
__
0 1 0
9 Slab -On -Grade Edge Insulatio
BATH 5'ft
0-
50 ft2
0 1 0
1,0Slab-On-Grade Edge. Insulatio
HALL 1 'ft
0
25 ft2
0 1 0
11SIab-On-Grade Edge Insulatio
FOYER .9 ft
0
92 ft2
0 1 0
12SIab-On-Grade Edge insulatio
BEDROOM 3 14 ft
0
169 ft2
ee
0 1 0
ROOF,
/
Roof
Gable
Roof
Rad
Solar
SA. Emitt-
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Metal 1847 ft2
0 ft2
Light
N
0.4
No 0.9
- No 0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under.Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood .'
3 Under Attic (Vented)
MASTER BATH
30.
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ftZ
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 112.
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1--
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Cavity Width
Space.R-\/%lllle
Height
Sheathing Framing Solar Below
reao
_ 1.
E Exterior Concrete Block
- Int InsdIASTER BE 4.1 16
0 8
0
128.0.ft2
0
0 0.3
0
2
W Exterior Concrete Block
- Int InsmASTER BE 4.1 7
0 8
0
56.0 ft2
0
0 0.3
0
3
S Exterior Concrete Block
- Int Insi lIASTER BE 4.1 14
0 8
0
112.0 ft2
0
0 .0.3
0
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3. of 6
FORM R405-2017 ANPUT. SUMMARY •GIHFCKI 'IST RFpnQT
WALLS
V*
Omt
To Wall MoeAdjacent Space
Cavity Width
-Et In
Height
Et -in
Are%k
Sheathing' Framing
P-Niall le EcaCtJon
Solar Below
Ahqnr r, de%
4
E
Exterior
Concrete Block- Int InsWASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
5
E
Exterior
Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
6
E
Exterior
Concrete Block - Int InsEKEDR00M 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
7
S
Exterior
Concrete Block - Int InsQINING/GRE'
4.1 30
0
8 0
:240.0 ft2
0
0
0.3
0
_ 8
W
Exterior
Concrete Block - Int InSQINING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.3
0
_ 9
W
Exterior
Concrete Block - Int InsulKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
10
E
Exterior
Concrete Block - Int Insul BATH .:
4.1 5
0
8 0
40.0 ft2.
0
0
u
0
_ 11
N
Exterior
Concrete Block- Int Insul FOYER.
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
_ 12
N
Exterior
Concrete Block -. Int Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
13
W
Exterior
Concrete Block - Int InsQEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block - Int InsREDROOM 3
4A 1
0
8 0
8.0 V
0
0
0.3
0
_ 1.5
N
Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.3
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered:orientation: _> chan ed to Worst. Case..
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1,
S 3
Metal Low-E Single Yes
1.04 0.29
N
32.4 ft2
1 It 0 in
1 ft 5 in
Drapes/blinds
Exterior 5
2
E 5
Metal Low-E Single Yes
1.04 0.29
N
6.9 ft2
1 ft 0 in
1 ft 5 in
None
None
3
E 6
Metal Low E Single Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
4
S 7
Metal; Low E Single Yes
1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 5 in
None
None
5
W 8
Metal Low E Single Yes
1.11 0.27
N
40.0 112
8 ft 0 in
1 ft 5 in
None
None
6
W 13
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior 5
GARAGE.
#
Floor Area Ceiling Area Exposed Wall -Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000264 1168.7 64:16
120.66
.0881
5
1/8/2020 4:43 PM EnergyGauge® USA6.0.02 (Rev. 1)-.FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM. R405-2017 INPUT SUMMARY [:NPM0 1ST 01;DnRT
HEATING SYSTEM'
# System Type
Subtype
Speed Efficiency .
Capacity
Block
Ducts
1 Electric'Heat Pump/
Split
Singl HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtu/hr cfm 0.85
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40,ga1 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
--- Supply --
--- Return --
Air
CFM 25,
CFM25
HVAC #
# Location R=Value Area
Location
Area Leakage Type
Handler
TOT
OUT QN
RLF .Heat
Cool
1 Attic
6 175 ft?
Attic
55 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling
ng Jan Feb
Mar
Apr
Apr €
Ma un
y J rj Jul
May Jun Jul
rj Au
Aug•
risep
Oct
Nov
Dec
Venting Jan Feb
Mar
p�
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1.
2
3
4 5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78 78 78.
78
78
80 80
80
80
PM
80
80
78
78 78 78
78
78
78 78
78
78
Cooling (VVEH) AM
PM
78
78
78
78
78
78
78 78 78
78 78 78
78
78
78
78
78 78
78 78
78
78
78
78
Heating (VVD)
68
68
68
68 68
PM
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68
68 68
68
68
PM'
68.
68
68
68 -68 68
68
68`
68 68
.66
66
MASS
Mass Type.
Area
Thickness Furniture Fraction
Space'
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3,
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH
Defeult(8 lbs/sq.ft.
ft2 -
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software. Page 5 of 6.
:ORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS .
Mass Type Area Thickness. Furniture Fraction Space
Default(816s/sq.ft. ft' ft 0:3 ' GREATlDINING
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE.402.4.1:1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE.WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street:. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a. continuous. air barrier.
not be used as a sealingmaterial.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation idropped ed g
n an ceilin /soffit
the insulation and any -gaps in the air barrier. shall be sealed.
shall be aligned with the air
gned barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance' of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing' shall be sealed.
Rim joists
Rim joists shall include the air barrier:
Rim joists shall be' insulated.
Floors .
The air barrier shall be installed at any exposed edge of
Floor framing. cavity insulation shall be installed !to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor framing decking, or floor
g g cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from: the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of.floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, .utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall -be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to. fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers 'and
Exterior walls. adjacent lo showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air.barrier shall be installed behind. electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots -that penetrate building thermal envelope shall
be sealed to the sub=floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers: shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
nkler cover plates and WIN or ceilings.
a. in addition, inspection or log walls shall be in accordance with the provisions of ICC-400.
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD .
ESTIMATED. ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index,.the more -efficient the home. .
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R '6.0
2. Single-family or multiple -family • 2: Single-family b) Return :ducts R . 6.0
c) AHU location Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms
5. Is this a worst case? (yes/no)
6.. Conditioned floor area (sq. ft.)
7. Windows, type and area .
- a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
c) Area
4. 3 13. Cooling system:
Capacity 34.8
a) Split system
SEER 15.0
5. Yes b) Single .package
SEER
c) Ground /water.source SEER/COP
6. 1753 d) Room unit/PTAC
EER
e) Other
7a. 1.058
7b. 0.285
7c. 151.4
8. Skylights
.a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA .
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood,. raised (R=value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A.' Exterior:
1. Wood frame. (Insulation R-value)
2. Masonry'(Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Kneewalls/skylight walls
d) Radiant barrier installed.
9a. 0.0
9b.
9c.
1DA1..
10A2. ' 4.1 :
14. Heating system:
Capacity
a) Split system heat pump
HSPF 8.5
b) Single package heat pump HSPF .
c) Electric resistance
COP
d) Gas furnace, natural gas..
AFUE
e) Gas furnace, LPG
AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0:97'
b) Gas fired; natural gas EF
c) Gas fired, LPG EF.
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
0 Heat recovery unit HeatRec%
g):Other
1061:
11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a..
30.0
b)'Cross ventilation No
11 b..
c)' Whole house fan No
11c.
19.0
d) Multizone cooling credit
11d.
No
e) Multizone heating credit
0 Programmable thermostat Yes
`'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features. which will be installed (or exceeded). in. this. home before final inspection. Otherwise,.a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: ` O�
Address of New Home: \ City/FL Zip: FT. PIERCE, FL 3�
1/8/2020 4:43:52 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1