HomeMy WebLinkAboutProject Informationwrightsoft® Project SummaryJob: Entire House DBate: QUICK CALCS, INC. "317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AQL.COM. Project • • . • For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: e.. Design Information Weather: Winter Design Conditions. Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heat" Coolin�gg Area (ftz) 1753 1753 Volume (ft3) 14741 14741 Air changes/hour 0.38 0.20 Equiv. AVF .(cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat Capacity balance point = 34 OF 8.5 HSPF 34600 .Btuh @ 47°F 27 OF 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Summer Design Conditions Outside db 90 OF Inside db. 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible.Cooling Equipment Load Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh. Use manufacturer's data n Rate/swing multiplier Equipmenf sensible load 0.95 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 . Btuh (none) Equipment latent load 5007 Btuh. Equipment total load 30652 Btuh. Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI`ref 79145.85 - Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh. Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160. cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load. sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .� + wrightsoft" Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 ,qCp Page 1 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N j ' wrightsoft Right-J® Worksheet Job: • Entire House Date: By:. QUICK CALLS, INC. :317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@c,40L.COM 1 Room name Entire House MASTER BEDROOM 2 Eq)osed wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 280.0 ft. 5 Room area 1753.0 ft- 280.0 ftz Ty Construction U-value Or HTM Area (ft-) Load Area (ft-) Load number (Btuh/ft2L-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A�ocs 0 143 ne} 4 00 2 55 488 448 1795 1141 - 192 < 192 769 489 1Ac1om ;, 1270 ne 35;56 7043 7 0 247 488 0 0 0 1Aclom : 1270 ne> 35'56 7043 16 0 581 1151 0 ;U 0 r:0 1Ac1om 1 270 . ne'= .. 35,56 45.24 . - 16 .. m :. 0 . ,. :'. 581 ,-, : .739..::, . .: -0 -' U 0 .. 0 11 V�! LD 13AAocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11DO 0390 se 10..92 1131 23 23 248 257 0 0 0 0 y/ 13A4ocs;-. 0143 sw 400 $55 437 396 1584 1007 56: 56 224 743 AM 0.7 , sw-.. 21:56 27 q 0 Q. 'L—G' 13AAws 0.143 nw 4.00 2-55 290 217 867 551 112 79 318 202 1A-c1om 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 4A5-2omd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P '12C-0sw's 0 091 255 1;.26 308 : : :: 784 C 16A-30md 0.032 - 0.90 2.32 1753 1753 1571. 4067 280 280 251 650 F 22/ktpl ::;'. 0989 •.-;` 27fi9 ;: OUO :1753 '163 :-A237 ;: .. 0..:: 280 •. ;45; :'.1246. .. 0 T. 6 c)AED excursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 Appliances/other 1000 0 0 Subtotal pins 6 to 13) 18467 17655 4779 3789 Less odemal load 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 18467 17655 0 4779 0 3789 34% 53% 6190 . 9340 34% 53% 1602 2005 - ITTotal room load Air required (cfm) 26995 6380 5794 I 1 124657 1160 1160 300 249 Calculations approved bVACCA.:tO meet all requirements of Manual J 8th Ed wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-4r-10 17:19:28 k CalcMDocuments%WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8. Front Door faces: N Page - wrightsoft' RighWO Worksheet Job: • Entire House Date: QUICK CALCS, INC. By: .317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@10L.COM Calculations approved byACCA.to meet -all requirements of Manual J 8th Ed wriglitsoTt' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 I&A ... k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rul' Calc = MJ8Front Door faces: N Page 2 -�- wrightsoft° Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: .317 ST..LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email:.QUICKCALCS AOL.COM 1 Room name LAUDRY BEDROOM 2 O ft 12.0 ft 3 Room head ight e 9h 8.0 ft heat/cool 8.0 ft heat1cool 4. Room dimensions 6.0 . x 6.0. ft 15.0. x 120 ft 5 Room area 36.0 ftz 180.0 ftz Ty . Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ft2L-•F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A�ocs ' ; 0143 ne, 4 00 2 55 0 0 0 96 80 319 203, 1Ac1om ' :1 270 ne; 35.56 70.3 0 0 0 0 0 1Ac1om 1270 ne; 35:56 7043 0 0 0 0 :• 16 0 5t11 1151 '1Ac1om' t.1,270 ,ne, . 35:56 4524 0 ; . 0 - : 0 . _ 0- 0.' 11 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 i—D 11DO 0.390 se. 10.92 1131 0 0 0 0 0 0 0 0 13A�1ocs 0143 sw 4:00 2.'S5 0 0 0 0 0 0 0 770 . sw:: 21:56 . _ .27 53 0 0 0 . 0 .., 0 ... 'o 13AAocs .0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1.270[n. 35.56 45.24 0 1 0 0 0 0 0 0 0,770 nw 21.56 _36..90 0 . 01 0 .0 0 0 0 n 6 c)AED excursion -3 -60 Envelope toss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 . 1772 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 15 Subtotal Duct loads 34% 530/0 38 13 95 50 345/6 53% 1615 541 1786 945 Total room load Air required (cfm) 51 145 2156 2730 2 6 101 117 _ Calculations approved bVACCA to meet all requirements of Manual _J 8th Ed .4CCA wr. ightsoTtRight-Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N Page 3 wrightsoft° Right-JO Worksheet Job: • Entire House Date: QUICK CALCS, INC. By: .317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name DINING/GREAT ROOM KrrCHEN 2 6grosed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat1cool 4 Room dimensions I 1 1:0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft' 209.0 ft' Ty Construction U-value Or HTM Area (ftz) Load Area Load number I (Btuh/ftk*F). (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 " 13A4ocs_' 0143 hey - 4:00 255 0 0 0 0 0: p :p .,0 1Ac1om :1270 ne; 3$56 70:43 0 0 0 0 ,• 0 : 0 ;0 l). 1Ac1om ;1 270 ne 3556 70.43 :: 0 0 0 0 :: D = 0 p : ;0 - 1Ac1om:. 1.270. nee 35;56 45.24 . - 0:: 0 .: - 0.:. 0 .... 0 :. .. :.` Q p p 11 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �D 11130 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A�Iocs. ;.0143 sw 400 255 267 226 903 574 98.; 98 392 249 4A5 tom' U.T/0 sw 2156 27 53 41 : 22 , 893 . _, ' 1140 ;'.' 0 :, ;0 , 0 0' 13A46cs 0.143 nw 4.00 2.55 178 137 549 349 0 .. .. 0 0 _.. _. 0 1A-c1om 1270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5 2omd 0.770 nw 21.56- 36.90 41, 0 880 1505 0 0 0 0 P C :12C-0sw •: 16A 0 0911 28 ; ' ' 0 ' 0 :. ~ 0 116 . ; 295 30md 0.032 - 0.90 2.32 588 588 527 1364 209 209 187 485 F .. 22/MtPI ;.- '. -... 0989 ,; _'.; _,- 27.69 '::' 0.00 588: ' , 50 ::1$65 : p ':' 209;', 1t . ,p 305 0 i 6 c)AED excursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 1000 282 220 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other p 1000 Subtotal (lines 6 to 13) 6136 6679 1399 . 1880 Less extemal load p 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 15 Subtotal Duct loads 6142 6693 1399 1880 34% 53% 2058 - 3541 340 53% 469 995 Total room load Air required (cfm) 8200 10234 1867 2875 386 440 88 124 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed Aft,'- wrigFtttsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 .:.k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup ,Calc = MJ8' Front Door faces: N Page 4 -f - wrightsoft® Right%I@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: .317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name BATH HALL ad wall. 5.0 ft 0 ft 3 Room h height 8.0 ft heaticool 8.0 ft heat/cool 4 . Room dimensions 10:0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0 ft2 25.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft.) Load number (BtufVft'L°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh Heat Cool Gross WP/S Heat Coal Gross NIP/S. Heat Cool 6 13A-4oc5-, CYAQ :ne 400 2,55 40 40 160 .102 = 0:' 0 t 0 .::p 1A-clom 4 270 '1 ne 35:56 7043 0 0 0 0 0= 0 0 0 1Ac1om 270 ne 35:56 70 43 0 0 0 0 0 0 I - 0 A 11 9Ac1om 13A-4ocs 1.270 ne` 35:56 45.24 .. 0 . 0 . 0 0 ": 0 , " :A 1 .,. >0 _ . _ •;,:;Q yJLO 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11DO 0390 se 10.92 11.3.1 0 0 0 0 0 0 0 0 13A-0ocs , "4A52orrt_. 0143 sw 400 2 55 0 0 0 0 0> :0 0 0 ':,0, 70 . sw 21i56.. 27:53 .. s0 0 . 0 .... p 0 :;<: 0 . 0 ,.. 0. 0.148 nw 4.00 2.55 0 0 0 0 0 0 0 0 %13A4ocs —G' 1A clom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd. 0.770 nw 21.56 36.90 0. 0 0 .0 0 0 0 0 P.. 12C-0sw.' - ° _0 091 :..: • 2:55 1:28 :. p .., '. 0 .= . 0 0 • :. :00 C 16A-30md 0.032 - 0.90 2.32. 50 50 45 116 25 25 22 58 0.06 `:: 0:06 ;. , :: 50 w. 6 c)AED emursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 p p 0 Appliances/other 0 0 Subtotal (lines 6 to,13) 433 235 22 56 Less external load p 0 0 0 Less transfer 0' 0 0 0 Redistribution 6 14 _ rJ 14 Subtotal 439 249 0 0 0 0 15 Duct loads 34% 53% 147 132 34°/a 53% 0 0 Total room load 528 316 0 0 Air required (cfm) 0 0 _ Calculations approved byACCA to meet all requirements of Manual J 8th Ed A ' - wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:19:28 Page 5 ..:k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJB Front Door faces: N wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. . 317 ST. LUCIE LN., FT. PIERCE, FL 34946-Phone: 772466-6799 Fax 772466-6796 Email; QUICKCALCS @(AOL.COM 1 Room name FOYER BEDROOM 3 2 E�osed wall 9.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 92.0 ft 13.0, x 13.0 ft 5 Room area 92.0 ft2 169.0 ft= Ty Construction U-value Or HTM Area (ft2) (ft') Load number (Btuh/ftz "F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A�ocs,; 0143 ne 4 00 2 55 01. 1.0 0 0 104 r 88 351 223' 1A-c1om '- 1 270 ne 35,56 70.43 0 0 0 0 0 0 ;0 - 0 1Ac1om ° 1270 ne, 3556 70:43 0 0 0 0 0 1Ac1am ; 1.270 . ne" 35:56 . 45.24 -0 . 0 .: 0 0 16 0 581. 739 11 yJ 13AAocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 Ip 11DO 0390 se 10.92 11.31. 23 23 248 257 0 0 0 0 13A4ocs: 0143 -sw: '4:00 - 2.55.: 8... 8 - 32 "; 20 8 - 8 32 20 G '4A52om,: 1 0770 sw .21.56, 27;53 -. .0 `.. 0, 0 , •. 0 , : 0'. 0 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A572omd 0.770 nw 21.56 36.90 0 0 0 0 0. 0. 0 0 P 12C 0sw`- ' . 0 091 '. ''.=' 2:55 A 28 ': 88 ':.� 88 :; - M4 :. . 113 ` 104 s ,:. 104 :.. , 26$ .133 C 16A-30md 0.032 0.90 2.32 92 92 82 213 169 169 151 • _ . , , 392 F :'• -22Atpl': - :. 0.989 . =... . = 27:69 .:. - 0.00:. _ 92 ,°` 9 `;249;: 0 • :.. -. _169 14' " 388 's:0 6 c)AED wcursion -25 -52 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1163 730 2020 1527 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 .0 0 0 14 Subtotal 1163 730 2020 1527 151 Duct loads 34°/6 53% 390 386 34% 53% 677 808 Total room load 1553 .1116 2697 2335 Air required (cfm) 73 48 127 100 Calculations approved byACCA to meet. all requirements of Manual J 8th Ed A r-1017:19:28 wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-AprPage 6 k Caes0ocuments\WYNNE-THE WINDSOR-REVISED.rup Cale = MA Front Door faces: N + wrightsoft° Duct System Summary Date: ate: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email: QUICKCALCS ,AOL.COM For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Heating Cooling Externalstatic pressure 0.50. in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Availabl6static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H20. 0.250 / 0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 cfm 1160 - cfm Total effective length .(TEL) 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl . Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox0 VIFx'' 19.5 115.6 st1 BEDROOM 2 c 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox 0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 Ox0 VIFx 36.5 135.0 st2 DINING/GREAT ROOM-6 C 3411 129 147 0.371 7.0 Ox 0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 0x0 VIFx 7.0 95.0 KITCHEN c 2875 88 124 0:366 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 ox0 VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 Ox 0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 31.90 150 124 0.273 6.0 Ox 0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox0 VIFx 40.9 135.0, st2 WIC c 216 4 9 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Gig Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (In) (in) Material Trunk st2 Peak AVF 612 602 .0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx t wri htsoft` Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:19:29 leCA 9 - Page 1 ...k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Cato = MJ8 Front Door faces: N Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist . Opening (in) Duct Mati Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft@ 2017-Apr-1017:19:29 f 9 Right -Suite® Universal 2017 17.0.14 RSU08101 . Page 2 ZCA ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N