HomeMy WebLinkAboutProduct Approval (4) Florida Building Code Online,,--, Page 1 of 5
5
BCIS Home Log Inn User Registration Hot Topics I Submit Surcharge Stats&Facts Publications?? FBC Staff W; BCIS Site Map Links Search
Product Approval
I 1 • USER:Public User
�teh'gx;iitti3 .._I •v:l �...,\ I"-1`,�1{.
Product Aooroval Menu>Product or Application Search>Application List>Application Detail
n T�7J FL# FL17184-R3
Application Type Revision Ll
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Plastpro Inc./Nanya Plastics Corp.
Address/Phone/Email 5200 W CENTURY BLVD.
LOS ANGELES,CA 90045
(440) 969-9773 Ext 16
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440)969-9773 Ext 18
scottjohnson@plastproinc.com
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation&Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J. King,P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL17184 R3 COI Certificate of Independence.pdf
Referenced Standard and Year(of Standard) StandardYear'
AAMA/W D MA/CSA 101/I.S.2/A 440 2005
ASTM E1886 2005
ASTM E1886 2002
ASTM E1996 2002
ASTM E1996 2006
ASTM E1996 2005
ASTM E330 2002
TAS 201, 202, 203 1994
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtD4vCo3EapiIIB W... 3/16/2017
Florida Building Code Online ^ Page 2 of 5
Equivalence of Product Standards
_ Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 03/10/2016
Date Validated 04/18/2016
Date Pending FBC Approval 04/18/2016
Date Approved 06/08/2016
Summary of Products
Go to Page Page 2/3
FL 4 Model, Number or Name Description
17184.21 u. Fiberglass Door Up to a 3'0 x 6'8 Glazed"Impact"Fiberglass Single Door(X
Configuration)Inswing/Outswing
Limits of Use. Installation Instructions
Approved for use in HVHZ: No FL17184 R3 II Inst 17184.21.1)df
Approved for use outside HVHZ: Yes .Verified By: Lyndon F. Schmidt,P.E.43409
Impact Resistant: Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.21 for any additional use FL17184 R3 AE Eva] 17184.21.odf
limitations, installation instructions and product particulars. Created by Independent Third Party:Yes
17184.22 v.Fiberglass Door Up to a-3'0 x 6'8 Glazed"Impact"Fiberglass Single Door
with a Sidelite(OX or XO Configurations)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 1I Inst 17184.22.1)df
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third_Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 17184.22 for any additional use FL17184 R3 AE Eval 17184.22.odf
limitations, installation instructions and product particulars. Created by Independent Third Party:Yes
17184.23 w. Fiberglass Door Up to a 3'0 x 6'8 Glazed"Impact"Fiberglass Single Door
with a'Sidelite(OXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 II Inst 17184.23.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 17184.23 for any additional use FL17184 R3 AE Eval 17184.23.1)df
limitations, installation instructions and product particulars. Created by Independent Third Party: Yes
17184.24 x. Fiberglass Door Up to a 6'0 x 6'8 Glazed"Impact"Fiberglass Double Door(XX-
Configuration)Inswing/Outswing
_ Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 II Inst 17184.24.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 17184.24 for any additional use FL17184 R3 AE Eval 17184.24.1)df
limitations, installation instructions and product particulars. Created by Independent Third Party: Yes
17184.25 y. Fiberglass Door Up to a 6'0 x 6'8 Glazed"Impact"Fiberglass Double Door
with Sidelites(OXXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No 1=1_17184 R3 II Inst 17184.25.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: Yes Created by Independent Third-Party: Yes
Design Pressure: N/A Evaluation Reports
'Other:See INST 17184.25 for any additional use FL17184 R3 AE Eval 17184.25.odf
limitations, installation instructions and product particulars. Created by Independent Third-Party;Yes
17184.26. z.Fiberglass Door Up to a nominal 3'0_x 7'0"Non-Impact"Glazed Fiberglass
Single Door with or without"Non-Impact"Sidelites(X,XO or
OX,OXO Configurations)Inswing/Outswing
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3 EapiI1B W... . 3/16/2017
plastpro
5200 W. CENTURY BLVD. z g;
LOS ANGELES, CA 90045
0 0"0
C4
xza
AL K a
74.00"MAX.OVERALL FRAME WIDTH E * 6 S
GLAZED FIBERGLASS DOUBLE DOOR z
INSWING/OUTSWING A
"IMPACT" N CZ
-3a ,
c Qw-
z z
v)o
c�cn
0 R:n 5 4d
GENERAL NOTES "c'
1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building W
M
o
Code (FBC)structural requirements excluding the"High Velocity Hurricane Zon&'(HVHZ). I R
o
X 0
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base =j n
material shall be beyond wall dressing or stucco. I M
>
o 0
3. When used in areas requiring wind bome debris protection this product complies with Section
1609.1.2 of the FBC and does not require an Impact resistant covering.This product meets missile
ry level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and Section 1609.1.2A of the FBC.
0 En
z
4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x o 0
buck masonry construction. v)
LL 5. Site conditions that deviate from the details of this drawing require further engineering analysis
by a licensed engineer or registered architect,
z z
t5
TABLE OF CONTENTS
SHEET# DESCRIPTION
w z
Ld
I Typical elevation,design pressures,&general notes
2 Door panel details OVERALL OVERALL: DESIGN PRESSURE(P;F)- T
GLASS -kSSU-
G FRAME. ,........
,SWIN —0
3 Horizontal cross sections z rj
Aypt.
'D DIMENSION z 'POSITIVE NEGATIVE
4 Vertical cross sections
.......... DATE 8/25/14
5 Buck and frame anchoring-2X buck masonry construction INSWING 74.00"x 82.00" 20.50"x 62.75" +50.0 -50.0 N.T.S.
6 Frame anchoring-I X buck masonry construction GI DWG.BY: AL m
2. 7 Astragal details CHK.BY. LFS
OLITSWING 74.00"x 80.50" 20.50"x 62.75" +50.0 -50.0
8 Bill of materials,glazing detail&components DPAWNG NO.:
F 17184.24
o
A? SHEEr__1 oF-f-
51 EXTERIOR ��� .............
a v�c1
GIQ i
lo
'F'F'*' o o a0 zo
q U N
43
47 52 46 4l �•e E m o m u v
INTERIOR 55 52a i-t
=z
1 HORIZONTAL CROSS SECTION Tw -_
N
35.75'MAX. T— a
DOOR I. 1.58'—^� mr r—•40" GI ?0 0
PANEL WIDTH L I I T .
20.5U'MAX. a g m
D.LO.WIDTH
I �1 REINFORCEMENT WOOD
am
fvrlock 1BS INTERIOR EXTERIOR o 0
Ix
Y
TOP RAI! LATCH L HINGE STILE a
Cellular PVC CetlulcrPVC a a
J x w
c w x f•DQ"—�I I+
O 1.58" —I
o p"
X
o 1 1 N LD N
z
i l 55
i%/ h
� L � BOTTOM RAIL LATCH 8 HINGE STILE 46
45 0011 or PVC 47 Reinforcement Q
m
4.5, W Z
s 2 N
NARDwRE A TABLE „QO
o m
MANUFACTURER MODEL
a 40 DOOR PANEL LOCK' SIGNATURE SERIES og7E. $ 25 4 zo
s� N.T.S.
DEADBOLT: SIGNATURE SERIES(980) o
a LOM YH COMMON 2 VERTICAL CROSS SECTION M.BY. AL
YAIE DEADBOLT: YH COLLECTION(80 SERIES) 2
c OHK•BY.. LFS 3
SCHIAGE 'F'LOCK: SERIES ¢
FL_DEADBOLT: 660)62 OR Ho.: a
— L—17184.24 0
N
SHED 2 OE 8 d
dt
1 1-11,CMIN.
4 49
EMB.(TYP.) '�// to
21 21 C ='`�' •� �o Jam-d n
4 Z
A
d O1
/ �\ M
��5 " -ZO
7 Em m
3 v o 3 EXTERIOR 40 \ a $p 'm a-a m
X 2 0 X 4 \ V
E uZ
3 Q 3 cZzl S
S 3a -
In
0
INTERIOR H go Li
En
9 10 a� J �
U
4 HORIZONTAL CROSS SECTION E am `" ¢-
3 5 4 3 Shown w/1Xsub-buck F N
3
v, 1-114"MIN• 1-1/4"MIN. o o
EMB.(TYP.) 4 4 4 EMB.(TYP.) a a
C 0.15" 0.15'
C'SINK C'SINK C ro
L (TYP.) (iYP.) L °
p
20 21 21 20 m
0 60 7 61 I y rn
z
V 7 U
W
d EXTERIOR � ° ° D)
40 q0 `\ 63 40 EXTERIOR qp Lt`
z
o ° w Z
IT
z ° 10 INTERIOR 27 Y3 INTERIOR 10 ° ° z
°d. B L 10 10 B c DATE: 8/25/14 0.
SCALE: N.T.S.
Bwc.BY.. AL m'
`J 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 HORIZONTAL CROSS SECTION E oRA�NG`NO.:LFS 3�
3 Inswing shown-oulswing 3 Inswing shown-outswing 3 Inswing shown-outswing FL-17184.24 v
also approved also approved also approved N
V SHEEr_,L OF $
a
R.\CllentskPlastaro,inc PERMANE Flodda Pmdutt A rovals FL-17184 C-Drawln s\Current FL-17184.21-.25.dw.4-4
m
m
Z Z Co
A ° n
e c c n
AW ° ' A—•
° 4
113
o n °tea °
On
CL oa x co
y v y °a
T G m �y 29 m °.
° O n O V
Z A Z a °
W <
a
0.15
a C'SINK J
° (TYP.)
m
1-1/4"MIN.
1-1/4"MIN. EMB.(TYP.)
EMB.(TYP.)
Z
m
:E
a r-
0
DO e
=,y
°m
an e
m
e IV O
1-1/4"MIN.
EMB.(iYP.) 1-1/4"MIN.
tit---EMB.(TYP.)
T
f_
Z c D
q n
3� °e A m
°e
�n A �a
g- n yr °
Q p
N ° c N
Z Z O
e � �
e
G m °
0
°e° ° till 111
CD e.SCHag
m C) `���;.•VCISNgE .�' ��i
1-1/4"MIN. No.43409
EMB.(TYP.) =*
$ Q PRODUCT: Documents Prop—d By:',.� _
PLASTPRO INC. Lyndon F. Schmidt �� R20RlCr' ,�,%
A v c FIBERGLASS DOOR P.E. No. 43409
•ol tb PART OR ASSEMBLY: �K BUILDING CONSULTANTS.I INC.
I� r � NO.D4DATE15 UPDATE TO 51H ED. (2014 FHC 6Y VERTICAL CROSS SECTIONS el l�
P.O. Box.:230.81 .659.9 7 33595
Phone No.: 813.859.9197
REVISIONS FBPE C.A. No. 9813
e - ' 03D14 R.W.BUILD-C....LTn NTH IND. /�'Z
t
J �
r
•�l
� 4"91,•' (vn l II II °v `"' !� cT' Z0.C
•.. ..-• E.
n I I SEE DETAIL �=ZUiZ o dn=nwo coNrnm•;
zro0
N
DmoTYP.HEAD&
S IAMBS m
OPENING dOPENING SmMA ]
II II � � .r mdaa
FRAME ASTRAGAL I I a2 a _ E ozGAL !
2X BUCK S OTWN FOR I a SHOWN FOR I f c° cut 1
'� REFERENCE I I F v
REFERENCE I I P v 2X BUCK
ILY ONLY I I F ^O NF
II -d II I
TYP. �P
0 0�
SEE DETAIL I I N SILL zo �z
II 1 II Co
U
Y
q
0q:� J W>
� F- C
D W ¢O• �W N �N
N 28 o xr
n BUCKANCHORING HINGEJAMB FRAME ANCHORING ASTRAGAL STRIKE JAMB 23 0
n Masonry 2X buck construction I Q m m
a a
Fi
0
L 3 27 -m
V
LATCH&DEADBOLTDETAIL
2.09" HOLE N V)
z
U 3/8"DIA. w g
9 En
CONCRETE ANCHOR NOTES: DETAIL
1. Concrete anchor locations at the comers may be adjusted to maintain the min. o <
edge distance to mortar joints.
2. Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to g
maintain the min.edge distance to mortar joints,additional concrete anchors 10 e
may be required to ensure the"MAX.ON CENTER"dimension are not exceeded.
10
3 Concrete anchor fable: ' ' Nr a
MIN CLEARANCE MW CLEARANCE. DETAIL 1 �J 5
ANCHOR 'ANCHOR M1N v o
TO MASONRY TO ADJACENT Outswing configuration o
TYPE SIZE EMBEDMENT - 10 ---
EDGE:. ANCHOR -0 13
a TAPCON® 1/4" 1-1/4" 2" 4" HOLE oA�E 8/25/14 0
ELCO 3/8"DIA. scaiE, N.T.S. m
ULTRACON® 4" MG.BY. AL
DETAIL 1 HINGE DETAIL CHK.BY. LFS 3
R WOOD SCREW INSTALLATION NOTES: Inswing configuration
1.Maintain a minimum 518"edge distance,I"end distance,&1"o.c.spacing of DRAW NG NO.: Q
wood screws to prevent the splilling of wood. FL-17184.24 0
SHEET S OF 8 d
z
10
1— SN:7 z rc'e p� om
4--&SEENOTE1
�V.. " `fro
o �i �'•.,,-....••• �4y�� >
L SEE DETAIL ''''''�ffttll 1�111 o,%,```1` o o m i
II UN••
oz�
Ito 9m �W
J TYP.HEAD& II X \ a N m cr a m
MASONRY JAMBS
OPENING I I E vz i
8—�
1
II ASTRAGAL
FRAME SHOWN FOR 28 mr-
REFERENCE ONLY
_"
os =Uo 5
m
,P •c"j• 1XBUCK� II am ¢Z
F iL � ��
N I I F of a
II N TYP. a a
SEE DETAIL I I SILL LATCH B DEADBOLT DETAIL
m 1,
a a
N Z
11 HINGEJAMB FRAME ANCHORING ASTRAGAL STRIKE JAMB W in
o
Masonry I buck construction FF
2.07' o 1
A CONCRETE ANCHOR NOTES:
'0 1.Concrete anchor locations at the comers may be adjusted to malntafn the mfn. ¢
edge distance to mortarJoinfs. a d
a 2 Concrete anchor locations noted os MAX.ON CENTER^must be adjusted to DETAIL 2 Z
molntdn the min,edge distance to morfarloints.addtional concrete anchors m
c maybe required to ensure the MAX ON CENTER"dimension are not exceeded. HOLE w =
L 3.Concrete anchor table: 3/9"DIA. N a
'.MIN CLEARANCE MfNrCLEARANCE a
o ANCHOR ANCHOR o °
TO MASONRY TO ADJACENT: z
.:,TYPE =SIZE .:EMBEDMENT: O a
z _ - EDGE'.; .::ANCHOR z a
Irw
oaTE: 8125114
°
a TAPCON° 1/4' ...1-1/4" 2° 4" ScatE:
N.T.S.
a
t• a^Etco a 1/a^ 1-1/1r HOLE
ULTRACON owa.BY. AL m
$ TAON® 3/16" 1-1/4^ 3• 1.1/2' 3/9'DIA• o*L BY.. LFS 3
WOOD SCREW INSTALLATION NOTES: DETAIL 1 DETAIL 1 DRAwMG Na.:
1.Maintain anm mum S/8°edOe distance.l"enddstance,&I°a.a.spacingof Inswing configuration Outswing Configuration FL-17184.24 <
wood screws to prevent the splitting of wood. N
sHEEr 6 of H
rt
ti
R.\Clients\Plast ro,Inc PERMANENT\Florida Product A rwals\FL-1718AC-Drawin s\Current\FL-1718421-25Av+ 4-7
0
w t-4 to
to
�•i
I{�2.88"
o I -
y �
fJ,
to
N
i.s
W V
V y
V
y •
1
14 0
o co
is
P_
O
O� H
°: I f--0.573" D J
G) •
n
Z _ n
n 0 A
a
o '
O
w t7 •
e 0
O
w
g �
L7 o
I - - I
0.059, o
V
W
w 7 •I1I1
II
cl
W I
y
b
N 1J
tT O^O ern -
09 a rn
T
3ooO°m
0 Cr
mto x0 w
�01 3 o y N o -
y
m -
{{1111111///
N..43409
In o� S2 PRODUCT: Doc—nta Preparod By:�/ ,••••� �•. .'
T - - F I^ PLAS►PRO INC- Lyndon F. Schmidt /i/ s OR70•• �,
IV V o m \ FlBERGLASS DOOR No. a3aos / S/Q AL{e
?00 CNii PART OR ASSEMBLY: C��{/BUILDING CONSULTANTS, INC.
Io' N N r y •I' 1 04DATE15 UPDATE TO 5TH ED. (2014) FBC B ASTRAGAL DETAILS �/�/ P.O. Box 230, Valrlao, FL 33595 .
Phone No.: 813.659.9197
/ REVISIONS FBPE C.A. No. 9813
®201 4 R.W.BUILDING Ca NSULTANTs INC.
BILL OF MATERIALS ���` ........
ITEM DESCRIPTION MATERIAL ITEM DESCRIPTION MATERIAL Q'�:
A 1 X BUCK SG>=0.55 WOOD 21 POLYFIBER COMPOSITE JAMB POLYFIBER
B 2X BUCK SG>=0.55 WOOD 23 #8 X 3"PFH WOOD SCREW STEEL =Te`i� A *
C 1/4"MAX.SHIM SPACE 27 LATCH STRIKE PLATE STEEL N a o•�_
D 1/4"X 2,3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 28 DEADBOLT PLATE STEEL W z F•'o 2 m F)
E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE 30 DOOR SWEEP �'i �'-., '.Gy�� o m aD
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 31 OUTSWING THRESHOLD BY DLP ALUM./WOOD �J/�� o m
F 1/4"X 2-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 32 ADA THRESHOLD ALUMINUM 11" o a.,
G 3/16"X 3-1/4"PFH ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD BY DLP ALUM./WOOD a :5 o ;z°chi
H 1/4"X 3-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS K r o m i?w
J 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 41 DOOR SKIN(MIN.0.075'THICK)PLAST-PRO/NANYA F =11,063 PSI MIN. FIBERGLASS a a q 'm a a w
L #10 X 2-1/7'PFH WOOD SCREW STEEL 42 TOP RAIL CELLULAR PVC s LL
N 1/4"X 1.3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 43 LATCH&HINGE STILE CELLULAR PVC E oZ /\
3 ASTRAGAL STRIKE PLATE @ HEAD STEEL 44 REINFORCEMENT WOOD FOR LOCKS WOOD S rd 4
6 SEALANT SILICONE 45 BOTTOM RAIL CELLULAR PVC
7 WEATHERSTRIP FOAM 46 FOAM CORE POLYURETHANE z
9 4"HINGE STEEL 47 LATCH&HINGE STILE REINFORCEMENT LVL N
10 #10 X 3/4"PFH WOOD SCREW STEEL 51 ODL LITE FRAME ALUMINUM �o z
20 JAMBFINGER-JOINT-PINE WOOD 52 #101-3/4'PFH SCREW STEEL 3o via
53 GLAZING COPOUND REDI-SEAL BY ODL,POLYMERIC FOAM P/MERIC FOAM.._— oN r s o
54 STRUCTURAL SILICONE DOW#995 SILICONE )_•'' =: 5 m w�
55 SCREW PLUG
60 ASTRAGAL 6063-T5 ALUMINUM BY DLP ALUMINUM- =y J o a o a
61 CONCEALED STIFFENER 6063 T6 ALUMINUM BY PLASTPRO INC. ALUMINUM o o
n 62 SLIDE BOLT ROD STEEL
63 #8 X 2"PPH SCREW STEELin
,v
4S6"
4.56" 34 GLASS
l Th to
BITE Oin 5' 53 1"OVERALL'''"`== w
r 53 54 GLASS THK. iE �N
d � 1
LEI-
IXTEMPERED GLASS
ADA SILL
HEAD 8 SIDE HEAD d SIDE 32 AIR SPACE
20 Jamb 21 Poiyfiberjmmb ISHC m
$ 1/8"ANNEALED GLASS w rw- a
0.09(Y'SAFLD(®PVB a
4.56" 4.56" " q INTERLAYER Z
€ 53 53 1/8"ANNEALED GLASS z mD
2
DATE 812$114 _
o�c G1 GLAZING DETAIL SC&E: N.T.S. 9
GwG.BY. AL m
S CHK 8P. LFS 3
Q
OUISWING THRESHOLD �1 INSWING THRESHOLD DRAWING No.:
9 31 pOSH °° BCS FL-77184.24 0
SHEEP 8 OF $ N
d ® HI
1)
r