HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online s, - ( Page 1 of 2
VtI� tj 1
U N7
8CIS Home Log In I User Registration I Hot Topics { Submit Surcharge ; Stats S Facts 1 Publications i F 3C Staff { BCIS Site Map i Links I•Search i
• Florida
Product Approval
USER:Public User
Product Aoorov la Menu>Product or Apphc ti_3 on Search>Application List>Application Detail -
FL# FL10674-1112
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
Toledo,OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Emall
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M.Niemlhen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R12 COI 2016 01 COI Nleminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D71S8 2008
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwd)gtBNbEY5V%2... 1/19/2017
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 04/18/2016
Date Validated 04/19/2016
Date Pending FBC Approval 04/20/2016
Date Approved 06/08/2016
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10674 R12 II 2016 04 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-Ri2.pdf
Impact Resistant:N/A Verified By:Robert J.M.Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section S. Evaluation Reports
FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT
SHINGLES FL10674-R12.1()df
Created by Independent Third Party:Yes
Back N R
Contact Us::2601 Blair Stone Road.Tallahassee FL32399 Phone:850-487-1824
The state of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement s Accessibility Statement lc Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the affice by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If
they have one.The ematis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which canoe made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
F®-
Credit Card
Safe
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V°/D2... 1/19/2017
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization H9503
353 CHRISTIAN STREET,UNIT#13
: TRIM 1 1 1 ERD - OXFORD,CT 06478
1 PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-117
One Owens Corning Parkway 1`1.10674-1112cawap
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3'and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,,.
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been;evaluated for compliance with the"Sth Edition (2014) Florida Building Code
sections noted herein-.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall-be in accordance with the requirements the Accredited Quality Assurance.Agency noted
herein.
CONTINUED COMPLIANCE: This,Evaluation Report is valid until such time as the named products) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the
product changes or the referenced Quality Assurance documentation'changes: .Trinity)ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising Iiterature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire.Evaluation Report shall be provided to the user by the manufacturer-or
its distributors and shall be available for inspection at the job site at the request of the;Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
4Pi.... :.,r.�,
�. �ce-
setfis t.s
+I�� �•.;,;,,�;,.,•.�, �d The,aafm1e seal appearing was authorhedbyRobeRNteminen,
Robert J.M.Nieminen,P.E. � .,,o^rONa�k�.4 P.Eon04/18/2016.-This does not serve asan electronically signed
` JJbm°trrrr} document.Signed,sealed les havebeen transmitted to the hardco
Florida Registration No.59166,Florida DCA ANE1983 t v
_ Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
-1. Trinity IERD does not.have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or
distributing products it evaluates.
2. Trinity ERD.is not owned,'operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will•acquire,a financial interest In any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in-the approval process of the
product.
_ 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen,P.E.are, in any way,the Designer of.Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance.unless retained
specifically for that purpose.
• °�.� TRINiI"Y!ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prone Standard Year
1507.2.50'R905.2.4 Physical Properties ASTM 1)3462- 2009
1507.2.7.1;R905.2.6.1 Wind Resistance ASTM D3161 2009
1501.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical.Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,112453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire B ass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshirer"are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration*, Duration Premium Cool, TruDefinitione Duration .Designer Color
Collection,TruDefinition Oakridge, Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire Hip&Ridge Shingles, High Ridge,WeatherGuardo HP Hip &Ridge Shingles, ProEdge.Hip&Ridge
Shingles and DuraRidgeT1 Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter.Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS•
5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,1s/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7
CerWcote ofAuthodkoNoe#950.3 FL10674-R32
Revision 7:04/18/2016
Page 2 of 8
'ERD
TRINITY;
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning.Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation.Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Pro a Standard Year
1507.2.5,R905.2.4' Physical Properties ASTM D3462. 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1S07.2.7:1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Enti Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File"R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&.Wind Resistance 20120516-R2453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 -
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
_4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classie and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire.are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire''are fiberglass reinforced,SAab asphalt roof shingles.
4.1.4 Duration*, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration-Designer Color
Collection,TruDefinition Oakridge, Oakridge and WeatherGuard* HP are fiberglass reinforced, laminated .
asphalt roof"shingles.
4.2 Berkshire Hip&Ridge Shingles, High Ridge,WeatherGuarde HP Hip &Ridge Shingles, ProEdge Hip&Ridge
Shingles and DuraRidge'"'Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter-Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on,which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory .
for fire ratings of this product.
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
CerN/lcate OfAuthonzation N9s03 FU0674-R32
Revision 7:04/18/2016
Page 2 of 8
. �.� TRINI"1'Y ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified-in- accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating'the shingles are acceptable for
use in all wind zones up to Va:d=150 mph (Vult 194 mph). Refer to Section 6 for instal lation'requirements
to meet this wind rating.
5.4.2 -All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in.accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM-D3161,Class F,indicating the shingles are
acceptable for use in all wind zones up to V®Sd=150 mph(Vrrit=194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. 'Contact-
-the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in'the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C.Rule•61G20-3.
6. INSTALLATION:
6_1 Underlavment: '
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61G203,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6_2 Asphalt Shinsles:
6.2.1. Installation of asphalt shingles shall comply'with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2•or R905.2, with the.following
exceptions:
➢ Berkshire shingles require minimum five(5)nails per shingle.
➢' WeatherGuarti HP shingles require minimum"six_(6)nails per shingle. .
Devonshire'"'shingles require minimum'six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations..
6.2.2 Fasteners shall be in,accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted. _
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, 'special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Feltundedaymerd Deck FAundedsyment Deck SdWharad
weatlredack®
Self-adhered undedaymard
WeatherLocl&
urrderlayment
Drip Drip edge pdp—» D�pedge
edge edge
. •' Nagsloeated-
ailsiocated 2".3"iromesve
2"-S'from eave
Install first Self-sealing adhesive SaQ aeaUng adAesive
S
t
arterSir�ip osnionedalon eave ►nsce0flru5mroerSrrip y positionedclongesve
shinglevrith '•., P 9 with8'romoved
6'removed ' Starter Strip shingle overhangs eaves and rakes I -'/i Stow Stdp Plus overhangs eaves and takes 1/e-V4"
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7'
[ertiJlrote ofAuthori:otion 89503 FL30674-R12
Revision7:04/18/2016' "
Page 3 of 8
1
\``'• TRINITY i ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard or Arse pm Normal Mansard or Arw pan
Wind Ares s High Wind dosv�n.s y Wind Aron. High Wind desvanss y
Area pare vlsntox normales Ars.s vlento.w.rt.s - Ana pars vientos normal" Anss vientos fwrtes
�1' Z' (B Z' t' Al t. t• Z. Z. t•
tt• it tz ut
W Exposure 6 6/B•Exposurs
Esposieldn Exposisidn
6.2.7 Minimum Nailing—Berkshire®:
sealant strip sealam strip
Lr tha de seAedar La tira de sdlador
.e----► •t---► a�--s• �.-•s r--.a •.--�a•---.e
8 iY 9 Vf 9 Yi' e yfI
8 rh~ 8 l e"1°
r
r
r
Standard Fastening Pattern 6-Nail Fastening Pattern
Sea6nt strip -
S !o&adasOW" '
,Lr P-•8 • • -►• ►•t~
Y AVW roolkn9 oament
Cenxinto do tedwdo astrlto
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-117
Certfeate oJAuthoriiation#9503 FL30674-R12
Revision_7:04/18/2016
Page 4 of 9
„ J TRINITY;ERD
6.2.8 Minimum Nailing—DevonshireTM':
n
I 7” •H gn 1 $" 8" 7"
•I 1�-1
aavos
Nails
5.5/8aexposufe Sodantlocation
Exposidbn de 5.5/8 pulp Ubioadbn del sepador s W
6!Y
Ten 1"Spots of Asphalt Roof Cement
Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing—Duration®,TruDefinition® Duration, Duration® Premium Cool&TruDefinition Duration
Designer Color Collection:
4-Nail Fastening Pattern a-Nall Fastening Pattern
su mmfASWINARaa7Ah su.11>1nf2shNnyarr2wmh
ran;iygrw ttaa.TOW
- I. •�- tr t^ t^ tz^ tr r
71
u...e�:.wr, :va. o•ro - - , os .,,em. :,.. -e.®m.of..w, .^r..- cw�...o.-. .. .o..u�.ou.a.�;n.._•
47A•46A^ - 4W a31a• -
Standard Fastening Pattern 6-Nall Fastening Pattern
Fastening for Slopes Greater Than 21:12
Sw.N.I19rHhnUr ana rMN
wo,tyPiw
V. tr I I Ir r
41T S.Sa"
T,
F"1'Spot1Q1A N ROCffigC. ft1
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7
CertiJlcate OfAuthorizatlon#9503 FL10674-11112
Revision 7:04/18/2016
Page 5 of 8
{` TRINITY ERD
6.2:1.'. Minimum Nailing—TruDefinition Oakridge®,Oakridge®:
01
4 Wl Pattem 6 Na1LPattam .
Esquema con 4 dauos Esquema con 6 davos
r r
I<-- iz
56/8"Fxpasure �� 55f8 Exposure Walls
Ezposlddnde5618puig Claws EWdd6ndo6618pu1g 5 SIG"Exposure Cfavos 6 Sir Exposure
Expag6n de6618pufg. EzposieOU de 6618pufg
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening foi Slopes Greater Than 2132
sunluDHlubnlna uu fHmn
Non,'rvp"
1' 12• 12•
tour r sap .
Mansard or Steep Slope Fastening.Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
. , �' .i/ �' ■� ilnols i1tM Ylarr
. Y17eEa arery
•�+ {;�;ate .:1:
. - rtaw..eM�2..ieA.dta
Exterior Research and Design,I.I.C. Evaluation Report 031940.02.12-R7
CefWcate o/AuthmlzaUsn M95R4 FL10674-1112
Revision 7:04/18/2016
Page 6 of 8
• ��'�' TRINITY ERD
6_3 Hip Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard•HP Hip and Ridge Shingles and
Prolidge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four
(4)nails per shingle. Installation of DuraRidgel Hip& Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand-sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.t 4 Fig.2
t— PnsrdlNlgaWd '
UNedlsn A TaPYlew SNIeVIe>r
4 J0 Nails Nails-
P
I I TopLanhaled Place
r '4-4 I I
A I 1 I
I I
P I I 1 I I
OSIf@ ml
ul
I
I
I
I
I
1
6.3.4 Minimum Nailing—WeatherGuardO HP Hip and Ridge:
Fig.A 4 4 Fig.C Hip&Ridge Shingle Fastening
Pnma(ng WNW Top Vbw
t`Wleelbn p
A
Nabs
p I I Nails Nails
p I I T
4 I I 2 2-
I
+ y r r
k--s'—�I
E><powle
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7
ceriveate ofAuthorf:otron X903 F1.30674-1112
Revision 7:04/18/2016.
Page 7 of 8
TRINITY ERD
6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard
Wind Direction Fastening
seam Ship Pattern
8-Exposure �'•I ;� ��► I.r
i .
t2' Sesiatnt
Fasten 711, 7'h° IF Exposure
Cover Exposed
Fastensn with
Roof Cement ----1IM.
6.3,6 Minimum Nailing—DuraRidge'"I Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Pnraiins Wild Dirotdan Yoe enn tan
k—Dirotttondernuontodsvant i• Vimsuperlor i•
Dinocanddrtnts prrdorni=t•
+ 2Ns • "nscotNu9S-Nair- • Gtiro
Naih
• z,..���r- { � LIE
is
• I t i i � �16€
I
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2,7.1/R905.2.6.1.
B. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of -
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmannoul.com
END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7
Cenprate ofAuthorirallon M03 FL10674-RIZ
Revision 7:04/18/2016
Page 8 of 8