Loading...
HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online s, - ( Page 1 of 2 VtI� tj 1 U N7 8CIS Home Log In I User Registration I Hot Topics { Submit Surcharge ; Stats S Facts 1 Publications i F 3C Staff { BCIS Site Map i Links I•Search i • Florida Product Approval USER:Public User Product Aoorov la Menu>Product or Apphc ti_3 on Search>Application List>Application Detail - FL# FL10674-1112 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Owens Coming Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Coming PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Emall Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M.Niemlhen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R12 COI 2016 01 COI Nleminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D71S8 2008 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwd)gtBNbEY5V%2... 1/19/2017 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated 04/19/2016 Date Pending FBC Approval 04/20/2016 Date Approved 06/08/2016 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R12 II 2016 04 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-Ri2.pdf Impact Resistant:N/A Verified By:Robert J.M.Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER,Section S. Evaluation Reports FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT SHINGLES FL10674-R12.1()df Created by Independent Third Party:Yes Back N R Contact Us::2601 Blair Stone Road.Tallahassee FL32399 Phone:850-487-1824 The state of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement s Accessibility Statement lc Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the affice by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The ematis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which canoe made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: F®- Credit Card Safe http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V°/D2... 1/19/2017 EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization H9503 353 CHRISTIAN STREET,UNIT#13 : TRIM 1 1 1 ERD - OXFORD,CT 06478 1 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-117 One Owens Corning Parkway 1`1.10674-1112cawap Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3'and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,,. P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been;evaluated for compliance with the"Sth Edition (2014) Florida Building Code sections noted herein-. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall-be in accordance with the requirements the Accredited Quality Assurance.Agency noted herein. CONTINUED COMPLIANCE: This,Evaluation Report is valid until such time as the named products) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.if the product changes or the referenced Quality Assurance documentation'changes: .Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising Iiterature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire.Evaluation Report shall be provided to the user by the manufacturer-or its distributors and shall be available for inspection at the job site at the request of the;Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: 4Pi.... :.,r.�, �. �ce- setfis t.s +I�� �•.;,;,,�;,.,•.�, �d The,aafm1e seal appearing was authorhedbyRobeRNteminen, Robert J.M.Nieminen,P.E. � .,,o^rONa�k�.4 P.Eon04/18/2016.-This does not serve asan electronically signed ` JJbm°trrrr} document.Signed,sealed les havebeen transmitted to the hardco Florida Registration No.59166,Florida DCA ANE1983 t v _ Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: -1. Trinity IERD does not.have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or distributing products it evaluates. 2. Trinity ERD.is not owned,'operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will•acquire,a financial interest In any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in-the approval process of the product. _ 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen,P.E.are, in any way,the Designer of.Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance.unless retained specifically for that purpose. • °�.� TRINiI"Y!ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prone Standard Year 1507.2.50'R905.2.4 Physical Properties ASTM 1)3462- 2009 1507.2.7.1;R905.2.6.1 Wind Resistance ASTM D3161 2009 1501.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical.Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,112453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire B ass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshirer"are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration*, Duration Premium Cool, TruDefinitione Duration .Designer Color Collection,TruDefinition Oakridge, Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire Hip&Ridge Shingles, High Ridge,WeatherGuardo HP Hip &Ridge Shingles, ProEdge.Hip&Ridge Shingles and DuraRidgeT1 Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter.Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS• 5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,1s/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 CerWcote ofAuthodkoNoe#950.3 FL10674-R32 Revision 7:04/18/2016 Page 2 of 8 'ERD TRINITY; ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning.Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation.Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1507.2.5,R905.2.4' Physical Properties ASTM D3462. 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1S07.2.7:1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Enti Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File"R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&.Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 - Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 _4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classie and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire.are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire''are fiberglass reinforced,SAab asphalt roof shingles. 4.1.4 Duration*, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration-Designer Color Collection,TruDefinition Oakridge, Oakridge and WeatherGuard* HP are fiberglass reinforced, laminated . asphalt roof"shingles. 4.2 Berkshire Hip&Ridge Shingles, High Ridge,WeatherGuarde HP Hip &Ridge Shingles, ProEdge Hip&Ridge Shingles and DuraRidge'"'Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter-Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on,which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory . for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 CerN/lcate OfAuthonzation N9s03 FU0674-R32 Revision 7:04/18/2016 Page 2 of 8 . �.� TRINI"1'Y ERD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified-in- accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating'the shingles are acceptable for use in all wind zones up to Va:d=150 mph (Vult 194 mph). Refer to Section 6 for instal lation'requirements to meet this wind rating. 5.4.2 -All Owens Corning hip&ridge shingles,Starter Strip Shingle and Starter Strip Plus noted herein are Classified in.accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM-D3161,Class F,indicating the shingles are acceptable for use in all wind zones up to V®Sd=150 mph(Vrrit=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. 'Contact- -the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in'the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule•61G20-3. 6. INSTALLATION: 6_1 Underlavment: ' 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G203,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6_2 Asphalt Shinsles: 6.2.1. Installation of asphalt shingles shall comply'with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2•or R905.2, with the.following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢' WeatherGuarti HP shingles require minimum"six_(6)nails per shingle. . Devonshire'"'shingles require minimum'six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations.. 6.2.2 Fasteners shall be in,accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. _ 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, 'special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feltundedaymerd Deck FAundedsyment Deck SdWharad weatlredack® Self-adhered undedaymard WeatherLocl& urrderlayment Drip Drip edge pdp—» D�pedge edge edge . •' Nagsloeated- ailsiocated 2".3"iromesve 2"-S'from eave Install first Self-sealing adhesive SaQ aeaUng adAesive S t arterSir�ip osnionedalon eave ►nsce0flru5mroerSrrip y positionedclongesve shinglevrith '•., P 9 with8'romoved 6'removed ' Starter Strip shingle overhangs eaves and rakes I -'/i Stow Stdp Plus overhangs eaves and takes 1/e-V4" Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7' [ertiJlrote ofAuthori:otion 89503 FL30674-R12 Revision7:04/18/2016' " Page 3 of 8 1 \``'• TRINITY i ERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Arse pm Normal Mansard or Arw pan Wind Ares s High Wind dosv�n.s y Wind Aron. High Wind desvanss y Area pare vlsntox normales Ars.s vlento.w.rt.s - Ana pars vientos normal" Anss vientos fwrtes �1' Z' (B Z' t' Al t. t• Z. Z. t• tt• it tz ut W Exposure 6 6/B•Exposurs Esposieldn Exposisidn 6.2.7 Minimum Nailing—Berkshire®: sealant strip sealam strip Lr tha de seAedar La tira de sdlador .e----► •t---► a�--s• �.-•s r--.a •.--�a•---.e 8 iY 9 Vf 9 Yi' e yfI 8 rh~ 8 l e"1° r r r Standard Fastening Pattern 6-Nail Fastening Pattern Sea6nt strip - S !o&adasOW" ' ,Lr P-•8 • • -►• ►•t~ Y AVW roolkn9 oament Cenxinto do tedwdo astrlto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,U.C. Evaluation Report 037940.02.12-117 Certfeate oJAuthoriiation#9503 FL30674-R12 Revision_7:04/18/2016 Page 4 of 9 „ J TRINITY;ERD 6.2.8 Minimum Nailing—DevonshireTM': n I 7” •H gn 1 $" 8" 7" •I 1�-1 aavos Nails 5.5/8aexposufe Sodantlocation Exposidbn de 5.5/8 pulp Ubioadbn del sepador s W 6!Y Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing—Duration®,TruDefinition® Duration, Duration® Premium Cool&TruDefinition Duration Designer Color Collection: 4-Nail Fastening Pattern a-Nall Fastening Pattern su mmfASWINARaa7Ah su.11>1nf2shNnyarr2wmh ran;iygrw ttaa.TOW - I. •�- tr t^ t^ tz^ tr r 71 u...e�:.wr, :va. o•ro - - , os .,,em. :,.. -e.®m.of..w, .^r..- cw�...o.-. .. .o..u�.ou.a.�;n.._• 47A•46A^ - 4W a31a• - Standard Fastening Pattern 6-Nall Fastening Pattern Fastening for Slopes Greater Than 21:12 Sw.N.I19rHhnUr ana rMN wo,tyPiw V. tr I I Ir r 41T S.Sa" T, F"1'Spot1Q1A N ROCffigC. ft1 Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R7 CertiJlcate OfAuthorizatlon#9503 FL10674-11112 Revision 7:04/18/2016 Page 5 of 8 {` TRINITY ERD 6.2:1.'. Minimum Nailing—TruDefinition Oakridge®,Oakridge®: 01 4 Wl Pattem 6 Na1LPattam . Esquema con 4 dauos Esquema con 6 davos r r I<-- iz 56/8"Fxpasure �� 55f8 Exposure Walls Ezposlddnde5618puig Claws EWdd6ndo6618pu1g 5 SIG"Exposure Cfavos 6 Sir Exposure Expag6n de6618pufg. EzposieOU de 6618pufg Standard Fastening Pattern 6-Nail Fastening Pattern Fastening foi Slopes Greater Than 2132 sunluDHlubnlna uu fHmn Non,'rvp" 1' 12• 12• tour r sap . Mansard or Steep Slope Fastening.Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: . , �' .i/ �' ■� ilnols i1tM Ylarr . Y17eEa arery •�+ {;�;ate .:1: . - rtaw..eM�2..ieA.dta Exterior Research and Design,I.I.C. Evaluation Report 031940.02.12-R7 CefWcate o/AuthmlzaUsn M95R4 FL10674-1112 Revision 7:04/18/2016 Page 6 of 8 • ��'�' TRINITY ERD 6_3 Hip Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard•HP Hip and Ridge Shingles and Prolidge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,using four (4)nails per shingle. Installation of DuraRidgel Hip& Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.t 4 Fig.2 t— PnsrdlNlgaWd ' UNedlsn A TaPYlew SNIeVIe>r 4 J0 Nails Nails- P I I TopLanhaled Place r '4-4 I I A I 1 I I I P I I 1 I I OSIf@ ml ul I I I I I 1 6.3.4 Minimum Nailing—WeatherGuardO HP Hip and Ridge: Fig.A 4 4 Fig.C Hip&Ridge Shingle Fastening Pnma(ng WNW Top Vbw t`Wleelbn p A Nabs p I I Nails Nails p I I T 4 I I 2 2- I + y r r k--s'—�I E><powle Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R7 ceriveate ofAuthorf:otron X903 F1.30674-1112 Revision 7:04/18/2016. Page 7 of 8 TRINITY ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard Wind Direction Fastening seam Ship Pattern 8-Exposure �'•I ;� ��► I.r i . t2' Sesiatnt Fasten 711, 7'h° IF Exposure Cover Exposed Fastensn with Roof Cement ----1IM. 6.3,6 Minimum Nailing—DuraRidge'"I Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Pnraiins Wild Dirotdan Yoe enn tan k—Dirotttondernuontodsvant i• Vimsuperlor i• Dinocanddrtnts prrdorni=t• + 2Ns • "nscotNu9S-Nair- • Gtiro Naih • z,..���r- { � LIE is • I t i i � �16€ I 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2,7.1/R905.2.6.1. B. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of - this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(414)248-6409;karen.buchmannoul.com END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R7 Cenprate ofAuthorirallon M03 FL10674-RIZ Revision 7:04/18/2016 Page 8 of 8