Loading...
HomeMy WebLinkAboutProject Information RoRIDA SOLAR ENERGY CMNTER`t Approved Solar Energy System Approval Date: April 1983 FSEC#S 1175 Revision Date: July 2011 DISTIUBUTOR SYSTEM Solar Hydronics Corp. 0-80-40 1423 Gunn Highway Odessa..Florida 33556 This system was evaluated-by the Florida Solar Energy Center (FSE.C) in accordance with the Florida Standards Program for Solar Domestic Water and Pool Heating Systems (FSEC Standard 104-05) and was found to meet the minimum standards established by FSEC. North Central. South The calculated.Florida Energy Factors for this system are: 2.1 2.2 '2.2 DESCRIPTION Collector Manufacturer FSEC Number Model Units --,J 1. Alternate Energy Technologies 00090N AE40. 1 2. Alternate Energy Technologies 0021SN MSC40 I 3. Solar Hydronics Corp. 00333N SHC-40 l 4. Alternate.Energy Technologies 00081N AE-21 2 5. Alternate Energy Technologies 00213N MSC-21 2 6. Solar Hydronics Corp. 00444N SI-IC-21 2 Tank Manufacturer Model Number Capacity(gal) Type: Direct ]. American Water Heater SE-62/112=80H-045S 80 2. Any Equivalent UL Listed Tank 80 2 3. Pump Manufacturer Model Number Power Draw(Watts) Rated Prover I. Taco 003-BC4 51.75 1/401J.P. 2. Solar Hydronics Corp. 003-BC4 51..75 1/40 R.P. 3. Solar Hydronics Corp.- 003 VTBC4 Pump/Control 51.75 1/40 H.P. i! Controller Manufacturer Model Number Type:Differential ' I. Independent Energy/Goldlin.e CM30/C=30/GL-30LC0 AC 2. Solar Hydronics Corp. SH.C=30-L.CO/Gir30LCO L rl 3. Stecca TRO=301-1-13-00 '1 + u C- e1 ✓ 4. IMC SOLR-2ELC-10 AC 5. Resol DeltaSol BS/1 AC Freeze Protection - I. -Manual drain down 2. Freeze protection valve 3. Automatic Recirculation 1(.79 c_l l.a�!_u!.Rv+u,G:­ Fu): aoa 32922-5/-0.1 - 1 El..121•o38•Il'!t71O.- l',r:Q 1-638.1010•:::�:c.iscc.uclaJn ! Li'.. +f!'S:;7L l'. Cll---..-rY?Fes.•al.L.)'9> if!•'.11Y:1�-.,_.eSF�/E}l'..IYT.L`AONLI.'•A Rvf il:l`:I: 1 J -/•,.- � - (�'r. •�.<��`r '.. - .:'`�;('!s":t'.:. 'C:i-t'-I t'4.`%i•{•:-�i\:i.'C .'C �-ii i.0.fri i'�'i.t,i.Cr.':`('':."yl: ''4,t',i-.^;(Y�-f/..'.( - _ - `�`r�•'�:,j•. ,a'>.. .Y--Y...:+'-Y���'\'".i•'-��'.:�Y_:ry fS��G f:_�7.:' i_r,:�2.�=>',>�7�?.�.).''T ` r.\ti�;tir `}>•�:r' � y^'.-\..�� .'v. i CERTIFIED SOLAR COLLECTOR _~SUPPLIER: BRAND: AltemateEnergy r j Altemets Energy Technologies MODEL: AE 40 1345 Energy Cove Court �= (?rt ='s Green Cove Springs,FL 32043 USA COLLECTOR TYPE: Glazed Flat Plate e CERTIFICATION#: 10001820 }' , # www.aelsolar.com' i tti Y In Accordance with: Original Certification: April 16,2013 SRCC Standard 100-2010-08 ` Expiration Date: December 03,2024 <' The solar collector listed below has been evaluated by the Solar Rating&Certification Corporation'"(SRCC'"),an ISO/IEC 17065 accredited and EPA s f recognized Certification Body,In accordance with SRCC OG-100,Operating Guidelines and Minimum Standards for Certifying Solar Collectors,and has been r• certified by the SRCC.This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by reference.This document must be reproduced in its entirety. Y' �¢✓ COLLECTOR THERMAL PERFORMANCE RATING ' Kilowatt-hours(thermal)Per Panel Per Day Thousands of Btu Per Panel Per Day Climate-> High Radiation Medium Radiation Low Radiation Climate-> High Radiation Medium Radiation Low Radiation ] ` Category (6.3 kWh/m'.day) (4.7 kWh/m'.day) (3.1 kWhlm'.day) (2000 Btulft'.day) (1500 Blulft'.day) (1000 Btu/ft',day) Category `n (TI-Ta) (TI-Ta) T 1 A(-5°C) 17.5 13.2 9.0 A(-9'F) 59.6 45.1 30.8 ^.� B(5'C) 15.3 11.1 6.9 B(9-F) 52.4 37.9 23.6 C(20"C) 12.2 8.1 4.0 C(36'F) 41.7 27.5 13.6 D(50'C) 6.3 2.7 0.1 D(90-F) 21.6 9.1 0.2 \k E(80-C) 1.3 0.0 0.0 E(144'F) 4.6 0.0 0.0 .Yj A-Pool Heating(Warm Climate)B-Pool Heating(Cool Climate)C-Water Heating(Warm Climate) D-Space&Water Heating(Cool Climate)E-Commercial Hot Water&Cooling J SA 1 ls, COLLECTOR SPECIFICATIONS ' Gross Area: 3.690 m' 39.72 ft' Dry Weight 69 kg 153 lb ^;.•j Net Aperture Area: 3.475 m' 37.40 ft' Fluid Capacity: 4.6 liter 1.2 gal r Absorber Area: 3.385 m' 36.44 ft' Test Pressure: 1103 kPa 160 psi TECHNICAL INFORMATION Tested in accordance with:ISO 9806:1994 ISO Efficiency Equation[NOTE:Based on gross area and(P)=Ti-Ta] M1ti` SI UNITS: r)=0.755-5.22470(PIG)-0,01950(P'/G) Y Intercept: 0.760 Slope: -6.215 Wlm'.'C IP UNITS: rl=0.755-0,92081(P/G)-0.00191(P'IG) Y Intercept: 0.760 Slope; -1.095 Btulhr.ft'.'F Incident Angle Modifier Test Fluid: Water 0 10 20 30 40 50 60 70 Test Mass Flow Rate: 0.0194 kg/(s m') 14.29 Ib/(hr ft') t'j Kra 1.00 1.00 0.99 0.97 0.93 0.79 Impact Safety Rating:11 REMARKS: I.C� 0' �sy i 1.1.. Technical Director Print Date:August,2015 Page 1 of 3 OG 100 CERTIFIED Please verify certification is active on the SRCC website. 0 Solar Rating&Certification CorporationTM <: www.solar-rating.org 4 400 High Point Drive,Suite 400♦Cocoa,Florida 32926 4(321)213-6037♦Fax(321)821-0910 r.�^'�•`:;'ti v.. rr�a` ".k.^•.Y,fn'.,;'y y>'S _-;...:r^;-.+:r.•�� a. =� r!? /`?'K,`:.nr 7'}Y n'i:�.�_'..s J Y,.. �,y� , _ �a_�. � :i.l;V`v<.. .rv;-'`w` v.'r/v:�t•'C,iv„��.�.'�...`_'!'._i._v._.vf�,!r.\_�,C���2�<.iy'=„<l„�?�.v,,,!'[?�s Ct::,, < �•:\j/. ,. . ti' - - ,<'(r <>C; `t��S:`:i - r.� i. _t; ;r^',i•i-✓.�f._...�i.�C, = "���5'.�;i '.�, i'.. _ C`�,-< _ __ 51 CERTIFIED SOLAR COLLECTOR SUPPLIER: BRAND: AlternateEnergy Alternate Energy Technologies MODEL: AE 40 1345 Energy Cove Court Green Cove Springs,FL 32043 USA COLLECTOR TYPE: Glazed Fiat Plate { www.aetsolar.com CERTIFICATION#: 10001820 Via' L' In Accordance with: Original Certification: April 16,2013 `J SRCC Standard 100.2010-08 Expiration Date: December 03,2024 The solar collector listed below has been evaluated by the Solar Rating&Certification CorporationTM (SRCCTM),an ISO/IEC 17065 accredited and EPA recognized Certification Body,in accordance with SRCC OG-100,Operating Guidelines and Minimum Standards for Certifying Solar Collectors,and has been certified by the SRCC.This award of certification is subject to all terms and conditions of the Program Agreement and %< the documents incorporated therein by reference.This document must be reproduced in its entirety. X ADDITIONAL INFORMATION(click here to return to the rating page) �^ Test Lab: Atlas Weathering Services Group Test Date: December 03,2012 1 s Test Report Number: R2 AT28423 Test Location: outdoors <? SOLAR COLLECTOR CONSTRUCTION DETAILS Y Gross Length: 3.078 m Gross Width: 1.199 m Gross Depth: 81.080 mm COLLECTOR MATERIALS Outer Cover. Glass sheet Enclosure bark: Aluminum Back Insulation: Foam,None Inner Cover. None Enclosure side: Aluminum- Side Insulation: Foam,None ; Absorber Description: Tubes connected to Fins Flow Pattern: Parallel/Harp �• Riser Tube: Copper .Fin: Copper ,. ' Iz Absorber Coating: Selective Tube to fin connection Laser Weld r, GLAZING Outer Cover Inner Cover a Material: Glass sheet None Surface Characteristics: Textured Thickness: 3.2 mm N/A .k Transmissivity: High(equal to or greater than 90%) Length: 3.027 m Width: 1,148 m Tube Glazing to Header Enclosure Seal: EPDM gasket r r' f :<U ABSORBER: Absorber Coating: Selective Header Material: Copper Header OD: 28.6 mm Header Wall: 0.9 mm 'r Riser Tube Material: Copper Riser Tube OD: 10.0 mm Riser Tube Wall 0.6 mm `• Thickness: ={ Fin Material: Copper Fin Thickness: 0.20 mm <iS') Print Date:August,2015 Page 2 of 3 OG-100 CERTIFIED Please verify certification is active on the SRCC website. ©Solar Rating&Certification CorporationTM www.solar-rating.org♦400 High Point Drive,Suite 400 Cocoa,Florida 32926 (321)213-6037 Fax(321)821-0910 ,, i ti .+�'.,,''-C!v'i n„ �� i',<' `•z i'✓'< �'r-�.< i_�r�`.f`i 'r".a ; 'r: i:)"ice 1.^i-. ,'•i'a^r.`��.."s^/.^.•- ,_l:>:, ,'>':+.^�;✓ i;';c c<,� .x- �' Yn. .�, s C� y F > �+� r v' ,r -.r x'Y`r.. :",�.Mf�"< ,�!`-.^�- .r i/;•K' � ^.<''t`. f'S,'{' i.F � - C s'`Y d' . +, � 'y a.a+ 1 �,Y .rz > Ny �_��.:..�'.�v'�.+.r,Ar.,�:.�.-,✓:'^>.?"�.^_ry! .��,'k;�✓•r ..rj'i,. �h...a,,. ,�,._... w F, r CERTIFIED SOLAR COLLECTOR SUPPLIER: BRAND: -AlternateEnergy Alternate Energy Technologies MODEL: AE-40 r i 1345 Energy Cove Court 1,rr� I i Green Cove Springs,FL 32043 USA COLLECTOR TYPE: Glazed Flat Plate a^�1 ✓ www.aetsolar.com CERTIFICATION#: 10001820 r XE In Accordance with: Original Certification: April 16,2013 _ SRCC Standard 100-2010-08 -' v' Expiration Date: December 03,2024 The solar collector listed below has been evaluated.by the Solar Rating&Certification Cor orationTM TM y g p (SRCC I"),an ISO/IEC 17065 accredited ; and EPA recognized Certification Body,in accordance with SRCC OG-100,Operating Guidelines and Minimum Standards for Certifying Solar Collectors,and has been certified by the SRCC.This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by reference.This document must be reproduced in its entirety. Flow Pattern: Parallel/Harp y Number of Riser 10 Tube Spacing: 112.8 min Number of times 1 c Tubes: each riser crosses ..; �. the absorber. •.. ' Length of Flow Path: 2.96 m Riser to Fin/Plate Laser Weld a. `4 Bond: ' INSULATION: ^r Location Type Thickness Location Type Thickness ` <''1> Back—Top Layer. Foam 35.6 mm Sides—Inner Layer. Foam 15.9 mm Back—Bottom Layer. None Sides—Outer Layer. None `A:j' Enclosure Fastening Methods: Rivets - iSt _ T ti} Power Output per Collector(W) y : {{ I Ti-Ta,G=1000 W/m'j <. ;? 0 10 30 50 70 2786 2586 2143 1643 1084 {.ty PRESSURE DROP r Flaw DP Flow AP S.1 i mUs Pa gprn In H.0 r y; 20 0 0.32 0.0 by 50 0 0.79 .0.0 a > 80 1 0 1.27 0.0 M1� U {`✓? ."yam :y %.i Print Date:August,2015 Page 3 of 3 OG70FIEt y, Please verify certification is active on the SRCC website. ©Solar Rating&Certification Corporation- x'> y www.solar-rating.org 400 High Point Drive Suite 400 Cocoa Florida 32926 4(321)213 6037♦Fax(321)821-0910 `C X ,`~�.�_..-•Rr {..-y_i.' Cr-Z�,_^,..+/ 'Y��.•�'Q'`i.�l,'r+,. ?��. -�.r/�`,.f.._ f°}_?''`2`ir ^'u ...}. ,. i 1 �¢sL���r Jar ail{ , +� y f '��•'" r ■ ���. r 7•i.,ri 1 x S�§. slynt'�`3/.ley �/i� s �. S 1' �:. � •�' y/ t S �K..h rti it• �. ®� ' } ly"•4 r lS�y. t 1/�+f� -1`i�� � 7 }j 'p"is Y���®� or ����� (.� 1 —s-S ,, ��_���`)Y fj�yr)`�'j:/1 a�J fs lY�� ® '•• • 4 J�fif�! I ay11 1TCJN •Y ' fjf ® f ®� fitrvrs ® 1 -so 1 ` , f.`icy_I�' �✓� • • ■ Y1 `fi`F III, :� ♦ r�J:: • ti i�xs'tir Lp S ��c`+•f • ■ • F� • e 0 %s7G r d x�i k,i� i • •— ■ .L.7i�? �'�~� 'i'"rocs t�`1-.- ■ • -o ..ei'I.'ie�,�yn:i.•cu. SOLAR COLLECTOR SOLAR COLLECTOR RETURN SUPPLY 120 VAC COMPONENT LEGEND ITEM oes No cwPrloN 5 4 1 ARVeTr 2 BALL VALVE-SOLARSUFilY 3 BALLVALVE-SOLAR RETURN d BOLER DRAIN(VALVE)-SOLAR SUPPLY s�+� "'' 12 5 SOLAR DRAM(VALVE)-SOLAR RE IM • 6 VOToFem CF£CK VALVE 6 • 7 CIRCULATION PUMP 7 8 FREEZE PROTE=N VALVE 9 GATE•SHUTOFPVALVE to RELIEF VALVE-PRESSURE ONLY P 11 RELIEF VALVE-TMaPRESSURE oo'o 12 DIFT'ERENTIALTEIVPCONTROL 2 ` 6 SOFT HOT WATER 3 11 (N aaL OUTLET S ' COLD WATER INLET- • S SENSOR WIRE CHASE I ROOF FLASHING 10%THERMISTOP SENSOR COMPONENT LEGEND 8 0 _ COOLIE DESCRIPTION CAP NO, 1 AIR VENT • : ,9 - 'r: .•; �4.��� 2 BALL VALVE•SOLAR SUPPLY `•�° 3 BALLVALVE-SOLAR RETURN 4 BOILER DRAIN(VALVE)-SOLAR SUPPLY • :�.!; '. 5 BOILER DRAIN(VALVE)•SOLAR RETURN - 6 MOTORIZED CHECK VALVE 7 CIRCULATION PUMP B FREEZE PROTECTION VALVE 9 GATE'SHUTOFP VALVE 10 RELIEF VALVE•PRESSURE ONLY 11 RELIEF VALVE-TEMP 3 PRESSURE 12 DIFFERENTIAL TEMP CONTROL ' ' Steca Elektronik GmbH 1 87700 Memmingen I Germany I Fon+49(0)8331 8558-0 1 Fax+49(0)8331 8558-132 1 www.steca.com , Steca TR 0301 U V, 3 inputs, ^ i- 44 s- 1 output 0301 U ((.(") i 42 C The Steca TR 0301 U controller was specially developed for 40 LLL3■3 the North American market based on the Steca TR 0301 basic O L controller.With its special certification(ETL label)from a Na- tionally Recognized Testing Laboratory(NRTL)in the US,the C controller meets the safety standards and minimum require- Mtge+ O ments of the North American market, U A feature of the Steca TR 0301 series of controllers is the animated graphic display,which offers a complete visualisa- C uS >� aistfioo tion of the solar energy system's operating status and solar circuit. The clearly arranged display ensures easy operation using pic- - V) tograms.The controller was jointly designed with an inter- nationally renowned design centre.The controller is used for monitoring and controlling solar thermal systems with one collector array and one storage tank.In addition,the control- ler performs important system monitoring and safety func- tions to ensure safe and long-lasting operation of the entire ,6o mm .3 mm system.The numerous additional functions of the Steca TR 0301 U also include a maximum storage tank temperature function,a tube collector function,an anti-freeze function, a holiday and storage retool function as well as a choice of % : temperature indications in either degrees Celsius(°C)or Fah- renheit(7).The operational safety of the system is supported E E by a sophisticated fault diagnosis.The multi-coloured LCD backlighting ensures quick and safe location of occurring er- rors and facilitates quick troubleshooting. The Steca TR 0301 U controller is supplied with a pre-fitted US mains connection cable and a preinstalled, pluggable - rar mm s.no mal 3 pump output. 51 Product features TR 0301 U ■ Compact,multipart designer casing System voltage 120 VAC,60 Hz ■ Maximum storage tank temperature optional 240 V AC,60 Hz Own consumption <1 W[<0.001 HPI ■ High level of operational safety through fault diagnosis Inputs 3 ■ Temperature display°C/°F 3 xtemperature(Pt1000) ■ Collector overtemperature disconnection output 1 1 x switch output relay(111), ■ Spring clamp terminals allow rapid and easy installation max 400 W/0.5 HP(120 VAC) or 800 W/1 HP(240 V AC) Line cord 75 inch,3 x 18 AWG at 221°F Displays - Tum-on temperature difference 8 K(46.4°FI ■ Graphical LCD display with backlighting Turn-off temperature difference 4K[39.2°F) ■ Animated representation of the systems and operating Ambient temperature 0°C[+32°F]...+45°C[+113°FI states Degree of protection IP 20/DIN 40050 Dimensions(X x Y x Z) 160 x 157 x 47 mm [6.3 x 6.18 x 1.85 inch] Operation Weight 350 g[12.35 ozl ■ Non-verbal menu navigation Temperature sensors 2 x Ptl 000 Collector sensor.1.5 m[59 inch] iliconecablewith bushing ■ Side switch for manual,auto,off s (Measuring range up to+180°C[+356°FI); Storage tank sensor..0.3 m[11.8 inch] twisted single conductor flat surface Functions sensors with compression cable lug ■ Holiday(storage tank retooling) I racnn;mldaraatzs•c/n•F (Measuring range up to+105°C[222 IF]) ■ Interval/tube collector ■ Anti-freeze ■ Display Storage tank top System with one storage tank r----------- ----1 I1 collector array _— J r, .1 Internal heat exchanger,intelligent pump control [areas of application] [inputs/outputs) INSUL=TUBEID Flexible, Closed-Cell Pipe Insulation Designed for the • Industry DESCRIPTION INSTALLATION when installed on low temperature surfaces INSUL-TUBE®pipe insulation is an environ- With a factory-applied coating of talc on the that are exposed to continuous high humidity. mentally-friendly,CFC-free,flexible elastomeric smooth inner surface,INSUL-TUBE®slides thermal insulation.It is black in color and is easily over pipe or tubing for quick installation. FLAME AND SMOKE RATING available in unslit tubular form in wall thick- When applied to existing lines,tubing is slit INSUL-TUBE®in wall thicknesses of 2"(50 mm) nesses of 3/8",1/2",3/4", 1",1-1/4", 1-1/2" lengthwise and fitted into place. (Slitting can and below has a flame spread rating of 25 or or 2"in sizes ranging from 3/8"I.D.to 8"IPS. be done on the job with a sharp knife or pre-slit less and a smoke development rating of 50 or (Available in 6'lengths and coils),INSUL- INSUL-TUBE®is available on request). All less as tested by ASTM E84,"Surface Burning TUBE°key physical properties are approved seams and butt joints should be sealed with an Characteristics of Building Materials". through supervision by Factory Mutual Research approved contact adhesive,making sure both INSUL-TUBE®is acceptable for duct/plenum Corporation. surfaces to be joined are coated with adhesive. applications,meeting the requirements of NFPA Fittings are fabricated from miter-cut tubular 90A/B. INSUL-TUBE® is non-porous,fiber-free and sections,and cover,flanges,etc.,from INSUL- resists mold growth.An EPA-registered antimi- SHEET®.K-Fit®factory fabricated fittings are Numerical If ratings alone may not define the crobial agent is incorporated into the product also available.ASTM C1710,Installation Guide performance of products under actual fire conditions.They are provided only far use in the selection of products to providing additional protection against mold, for Flexible Closed Cell Foams,should be used meet limits specified when compared to a known standard. fungal and bacterial growth. as an installation guide. INSUL-TUBE°is GREENGUARD®certified as a OUTDOOR APPLICATIONS low VOC material,meeting the requirements of INSUL-TUBE®is made from a UV-resistant the "Children&Schools"and"Indoor Air Qual- elastomeric blend.For moderate UV exposure ity"classifications. (residential applications),no additional protec- tion is.needed.For severe UV exposure(rooftop APPLICATIONS applications)or for optimum performance, SPECIFICATION COMPLIANCE INSUL-TUBE®is used to retard heat gain and K-FLEX®374 Protective Coating,approved ' prevent condensation or frost formation on jacketing or K-FLEX Clad°is required. y M 10-2131 Vol. refrigerant lines,cold water plumbing,and ''Compliant chilled water systems.It also retards heat flow UNDERGROUND Classification for hot water plumbing,liquid heating,dual For buried lines above the water table,use a (Recognition No. 0 , temperature piping,and many solar systems. clean fill such as sand(3"-5"layer)to protect t •I INSUL-TUBE°is designed for the HVAC and INSUL-TUBE®before backfilling.It is recom- according to UL 723 and Refrigeration industry. mended that materials to be buried are properly es requiremen , , sealed at all seams and butt joints with an ap- Approval I INSUL-TUBE®is recommended for applica- proved contact adhesive.For optimum perform- *NFPA No.101 Class' Rating -Meets tions ranging from-2977 to 220OF(-182°C ance,the lines should be encased in a conduittary Materials for Air,entsI fistribution Systems to 104°C).The expanded closed-cell structure to protect them from problems associated with -Meets requirements of ASTM C 411(Test Method forI makes INSUL-TUBE°an efficient insulator and ground water intrusion and compaction. Surface Performanceof High Temperature requirements-Meets o tand 16.0 provides effective moisture vapor resistance. (Mold Growth/Air Erosion) INSUL-TUBE°can be used with heat tracing/ RESISTANCE TO MOISTURE ' heattapes. VAPOR FLOW *Meets residential and non-residential requirements for CommissionCalifornia Energy 1 The closed-cell structure and unique Standards Title 24 INSUL-TUBE°has a tough skin that withstands formulation of INSUL-TUBE®effectively retards "'O certified tinderI tearing,rough handling,and severe envi- the flow of moisture vapor,and is considered IndoorQuality I -Meets energy code requirements of ASHRAE 1 ronmental conditions,yet is flexible for easy a low transmittance vapor retarder.For most installation.INSUL-TUBE®has superior cold indoor applications,INSUL-TUBE®needs no weather flexibility. additional protection.Additional vapor barrier protection may be necessary for INSUL-TUBE® w� Made in USA 0��E=774, FM U K FLEX USA , Containsa Pmtective �.�� �. M[imimbialAgent QREENGUMD` INNOVATION IN INSULATION Anppo11[A J 0 PROPERTIESPHYSICAL ` TEST METHODS Thermal Conductivity(K) 90'F(32°C)Mean Temp 0.258(0.0372) ASTM C 177/C 518 BTU-in/hr-RI-°F(W/mK) 757(24°C)Mean Temp 0.245(0.0353) ASTM C 177/C 518 Density 3-6 PCF ASTM D 1622/D 3575 Operating Temperature Range(Flexible to-40°F(-40°C)) -297°F(-182°C)to+220°F(lG4°C) Water Vapor Permeability Dry Cup.Perm-In 0.03 ASTM E 96 Water Absorption%(Volume Change) 0 ASTM C 209 Flame Spread/Smoke Developed (up to 2"wall) <25/50 ASTM E 84 Ozone Resistance Pass ASTM D 1171 Chemical/Solvent Resistance Good Mildew Resistance/Air Erosion Pass UL 181 UV Weather Resistance Pass QUV Chamber Test THICKNESS RECOMMENDATIONS I CONTROL CONDENSATION PIPE SIZE 0' • O' •' Normal Conditions(Max 851,29"C-70%R.H.) 3/8"I.D.thru 1-318"I.D. 3/8"(10 mm) 1/2"(13 mm) 3/4"(19 mm) 1"(25 mm) Over 1-318"thru 3"IPS 3/8"(10 mm) 1/2"(13 mm) 1"(25 mm) 1"(25 mm) Over 3"IRS thru 4"IPS 1/2"(13 mm) 1/2"(13 mm) 1"(25 mm) 1-12"(38 mm) Over 4"IPS 1/2"(13 mm) 3/4"(19 mm) 1"(25 mm) 1-12"(38 mm) Mild Conditions(Max 807,,26"C-50%R.H.) 318"I.D.thm 2-18"I.D. 3/8"(10 mm) 3/8"(10 mm) 1/2"(13 mm) 1/2"(13 mm) Over 2-1/8"thru 3"IPS 3/8"(10 mm) 318"(10 mm) 1/2"(13 mm) 3/4"(19 mm) Over 3"IPS thru 4"IPS 1/2"(13 mm) 1/2"(13 mm) 3/4"(19 mm) 314"(19 mm) Over 4"IPS 1/2"(13 mm) 1/2"(13 mm) 3/4"(19 mm) 314"(19 mm) Severe Conditions(Max 907,32"C-80%RIO 3/8"I.D.thru 1-18"I.D. 314"(19 mm) 3/4"(19 mm) 1-1/2"(38 mm) 1-12"(38 mm) Over 1-1/8"I.D.thru 4"IPS 3/4"(19 mm) 1"(25 mm) 1-12"(38 mm) 1-12"(38 mm) Over 4"IPS 3/4"(19 mm) 1"(25 mm) 2"(50 mm) 2"(50 mm) INSUL-TUBE6 in thickness noted within the specified temperature ranges will prevent condensation an indoor piping under design conditions defined below.Thickness recommendations above 2"can be sleeved to achieve thickness desired.Normal: Maximum severity of indoor conditions rarely exceed 857(29"C)and 70%R.H.in United States.Mild:Typical conditions are most air-conditioned spaces and and climates.Severe:Generally found in areas where excessive moisture is introduced or in poorly ventilated areas where the temperature may be depressed belowthe ambient. Underconditions of high humidity,additional thickness of insulation may be required.NOTE Thickness recommendations calculated using 0.2575 K-factor (0.245 plus 5%test error allowance). SQUAREPIPE"R"VALUES PER II NOMINALII.D. 318" 2.7 3.6 5.6 8.5 12.0 14.6 20.4 1/2" 2.5 3.4 5.4 7.9 11.1 13.5 18.9 5/8" 2.5 3.3 5.4 7.5 10.5 12.8 17.8 3/4" 2.3 3.1 5.4 7.5 9.9 12.1 16.8 7/8" 2.3 3.2 5.4 7.2 9.5 11.6 16.1 1-18" 2.3 3.1 5.5 7.1 8.9 10.8 15.8 1-318" 2.2 3.2 5.3 7.3 8.4 10.2 14.9 1-58" 2.4 3.1 5.1 7.1 8.1 9.8 14.6 1-1/2"IPS 2.3 3.0 4.9 6.7 7.7 9.3 13.8 2-18" 2.3 3.0 4.9 6.8 7.6 9.2 13.6 2"IPS 2.3 2.9 4.8 6.5 7.4 9.0 13.3 2-12"IPS 23 3.0 4.6 6.3 7.2 8.6 12.6 2-5/8" 2.3 3.1 4.7 6.4 7.3 8.8 12.9 3-18" 2.3 3.0 4.6 6.2 7.1 8.5 12.4 3"IPS 2.3 3.2 4.6 6.1 7.0 8.3 12.2 3-58" 2.3 3.2 4.6 6.1 6.9 8.3 12.1 4-1/8" 2.3 3.1 4.6 6.0 6.8 8.1 11.7 4"IPS 2.3 3.2 4.7 6.0 6.8 8.1 11.6 5"IPS 3.2 4.5 5.9 6.6 7.8 11.1 6"IPS 3.1 4.5 5.8 6.5 7.6 10.9 8"IPS 3.1 4.4 5.6 7.4 Note:"R"factors were calculated using a K factor of 0.245(at 75"F,24"C mean temp.)and nominal wall thickness is each case.Lower operating temperatures will result in improved R values.Contact Technical Services for specific recommendations. K-FLEX USA-100 Nomaco Drive-Youngsville,NC 27596-toll free 800-765-6475-fax 800-765-6471-www.kflexusa.com K-FLEX USA ©May 2010 K-FLEX USA.INSUL-TUBE®is a registered trademark of K-FLEX USA.The GREENGUARD®INDOOR AIR QUALITY CERTIFIED mark INNOVATION IN INSULATION is a registered certification mark used under license through the GREENGUARD®Environmental Institute. INDS-0001-1211 J � p 117e6W.1601.11 SL CID",631J,Ohio 4.1135 PLASTIC Pit:(800)321-9532 0 F➢s:(800)321-9535 iaa;w.oatey.coni WATER HEATER PANS SUBMITTAL SPECIFICATION Engineering Specification: Oatey Plastic Water Heater Pans car!be installed under electric water Job Reference heaters to protect from water damage. Available with V'PVC.or 1"CPV&.&ain.fittings to.allow for ;connection to indirect drain. f 7?' t (All dimensions in inches) Manufactured from 0.0625"plastic polymer �o- 1"PVC or 1"CPVC drain fitting provided Pre=cut side opening accommodates drain fitting For ruse.with Electric Water Heater Tanks +: Meets requirements-of Southern Building Code ♦. .Pan depth is 2.50" 4 Vicat Softening Temperature is 180P F Product Description Qtv Inside Outside. No., Diameter Diameter A g WATER HEATER PANS WITH 1"CPVC FITTING 34160 18"Plastic Water Heater Pan-Bulk 12 18 18.75 34161 20"Plastic Water Heater Pan-Bulk 12 20 21.25 34162 22"Plastic Water Heater Pan—Bulk. 12 22 23.25 34163 ' 24"Plastic Water Heater Pan-Bulk 12 24 24.50 34164 26"Plastic Water Heater Pan.-Bulk' 12 26 26.75 _ 34168, 28"Plastic Water Heater Pan-Bulk 12 28 29.75 34165 30"Plastic Water Heater Pan-Bulk 12 30 31.00 WATER HEATER PANS WITH 1"PVC FITTING 34060� 18"Plastic Water Heater Pan-Bulk 12 18 18.75 34061 20"Plastic Water Heater Pan-Bulk 12 20 21.25 34062 22"Plastic Water Heater Pan-Bulk 12 22 23.25 34063 24"Plastic Water Heater Pan--Bulk 12 24 24.50 34058 24"Plastic Water Heater Pan—Bagged_ 6 24• 24.50 34064 26"Plastic Water Heater Pan-Bulk 12 26 26.75 34072 28"Plastic Water Heater Pan-Bulk 12 28 .29.75 34065 30"Plastic Water Heater Pan-Bulk 12 30 31.00 WATER HEATER PAN ADAPTERS 34086, 1-1/2"PVC Adapter 32 34088 1"PVC Adapter 12 39089 1"CPVC Adapter 12 Data is subject to manufacturing tolerances:. 'H-17 Visit;vMw.oatev:com for updates 10/2005 Residential Electric W A T E R H E A T E R S Direct Solar Water Heaters A 6-Year Limited Tank/6-Year Limited Parts Warranty's American direct solar water heaters are designed for installation as a part of a direct(open loop) solar water heating system or for use with .� external heat exchangers in closed loop systems.Available in 65,80 and 119-gallon capacities these models provide storage for the hot water produced by the solar collectors and a supplementary electric 4, heating element that maintains consistent water temperature during periods when solar energy is not available. '= S§. Multiple Connection Options for Installation Flexibility 3 • Side and top connections for open loop systems or closed loop systems using an external heat exchanger E a� Electrical • 4500 watt heating element-long lasting low-watt density design spreads wattage over larger surface area to prolong element life and maximize efficiency • Pre-wired for surface mount temperature sensor(sensor supplied separately) Tank Construction • Glasslined Steel Tank—glasslining protects against corrosion to maximize tank life • 2-inch thick"Environmentally-Friendly"Non-CFC Foam insulation(1116 Value) reduces standby heat loss Anode Rod • Aluminum anode rod with stainless steel core protects tank against corrosion CSA Certified and ASME Rated T&P Relief Valve , Durable Tamper-Resistant Brass Drain Valve Compliance • Units are UL and cUL listed to UL 174 Standard for Household Electric Storage Tank Water Heaters and CAN/CSA-C22.2 No.110-M90;Complies with California legislation AB 1953 and Vermont legislation Act 193 that limits the lead content in plumbing fixtures that come into contact with drinking water to a maximum of 0.25/o. Standard 6-Year Limited Tank and Parts Warranty La UadCW-t • Optional 10-year extension on tank warranty when used in a residential application Eligible for a 30%federal tax credit when installed as • 3-year tank and 1-year parts warranty when installed in a commercial part of a complete solar application water heating system. • For complete warranty information consult written warranty supplied with For more information visit the product,online at www.americanwaterheater.com,or call American Water www•americanwaterheater.com Heaters at 800.456.9805 00 No part ofthis work maybe reproduced or transmitted in any form or by any means,electronic or mechanical,including photocopying and recording,or by any Information storage retrieval system,without permission in writing from American WaterHeaters. Residential Electric Direct Solar Water Heaters W A T E R H E A T E R 5- UPPER ACCESS HOT COLD T&P PANEL 4S00 WATT LOCATION HEATINGELEMENT Op Op QO A O ANODE COLD RETURN HOTSUPPLYFROM 11 TO SOLAR ® SOLAR COLLECTORS COLLECTORS � HOT SUPPLY FROM FLU SOLAR COLLECTORS C COLDRETURN LOWER ACCESS PANEL TO SOLAR TEMPERATURE SENSOR FLU COLLECTORS ® MOUNTINGSTUD p DRAIN VALVE 1041S (UP 11 WEIGHT SE62-6 65 1 4500 21 16 60-1/4 22 59-1/4 20-1/2 7-1/2 152 SE62-80H-045S 80 1 4500 21 16 60-1/4 24 59-1/4 20-1/2 7-1/2 191 SE62-119R-0455 119 1 4500 21 16 62 28 61-1/2 20-1/2 7-1/2 278 *Limited warranty on tank and parts.See written warranty supplied with the water heater for complete details. All solar loop and domestic water connections are 3/4"NPT.Top solar loop and domestic water connections are male NPTwith factoryAnstalled dielectric pipe nipples.Side solar loop connections are female NPT and are plugged from the factory. Specification Furnish and install,where indicated,in accordance with manufacturer's instructions and in compliance with all rules and regulations of authorities having jurisdiction. Storage tank(s)shall be American®Model as manufactured by American Water Heaters or equivalent.Storage tank(s)shall have a nominal storage capacity of gallons,recovery of GPH at °F temperature rise and supplied with auxiliary heating elements rated at 4.5 KW, volt.Storage tank(s)are hydrostatic tested at 300 PSI having a working pressure of 150 PSI and shall have a Fused Ceramic Shield internally lined tank applied under pressure and fired at 1600°F allowing for maximum protection.Storage tank(s)shall be equipped with an approved pressure and temperature relief valve.The outer jacketing shall have a baked enamel finish.The tank shall be foam insulated with an EPA-approved,non-CFC material 2"in thickness.Storage tank(s)shall have a 6-year limited warranty against corrosion as outlined in the written warranty. Distributed By: Order Entry and Sales Warranty and Service 500 Princeton Road(FEDEX,UPS) 500 Princeton Road(FEDEX,UPS) Johnson City,TN 37601-2030 Johnson City,TN 37601-2030 P.O.Box 4808(Mailing) P.O.Box 1597(Mailing) Johnson City,TN 37602-4808 Johnson City,TN 37605-1597 (800)937-1037 (800)456-9805 FAX(800)581-7224 FAX(800)999-5210 NCESS00708 No part ofthis work maybe reproduced ortransmitted in any form or by any means,electronic or mechanical,including photocopying and recording,or by any information storage retrieval system,without permission in writing from American Water Heaters. J • Submittal Data Information 101-066 11vaco Plumb `n' Plug® Domestic Hot Water Circulators EFFECTIVE: February 14,2014 SUPERSEDES: March 1,2011 JOB ENGINEER CONTRACTOR REP. ITEM NO. MODEL NO. General Product Information: Performance Data: Taco Plumb n' Plug® (PNP) Circulators periodically recirculate Flow Range: 0-7 GPM (003), 0-19.5 GPM (005) hot water through the domestic water piping system to decrease 0- 11.5 GPM (006) the delivery time to outlet fixtures and reduce wasted water. Head Range: 0-4.5 Feet(003), 0-8.5 Feet(005) These UL-listed'units feature quiet, efficient operation and low 0-9.5 Feet(006) power consumption. Self lubricating, with no mechanical seal Minimum Fluid Temperature:40OF(4°C) and Tacos unique replaceable cartridge design, Plumb n' Plug® Maximum Fluid Temperature:220OF(104°C) circulators are field serviceable and maintenance free. An Maximum Working Pressure: 125 PSI optional Aquastat is available for constant circulation Applica- tions to maintain temperature between 95°F and 1151F. Features: Materials of Construction: • UL Listed CIRCULATOR: • Optional 950F-1150F Aquastat Available Casing (Volute): Bronze or Stainless Steel • Standard High Capacity Output Stator Housing: Steel • Compact Design Cartridge: Stainless Steel •Quiet, Efficient Operation Metallic • Direct Drive-Low Power Consumption Impeller: Non Shaft: Ceramic • Unique Replaceable Cartridge Design-Field Serviceable Bearings:Carbon • Self Lubricating O-Ring&Gaskets: EPDM • No Mechanical Seal • Unmatched Reliability-Maintenance Free INTEGRAL FLOW CHECK(IFC): •Sweat Connections- Bronze Body&Plunger:Acetal • Union&Threaded Connections-Stainless Steel Spring:Stainless Steel • Flanged-Stainless Steel O-Ring: EPDM Model Nomenclature: Mounting Positions: BC - Bronze, '/2" Sweat B — Bronze,3/a" Sweat ST — Stainless Steel,3/a" FNPT SC — Stainless Steel, Union Connection SF — Stainless Steel, Flanged oa ' PNP — Plumb n'Plug® STANDARD OPTIONAL OK IF OVER 20 PSI Electrical Data: MODEL VOLTS Hz Ph AMPS RPM HP 003-PNP 0.45 005-PNP 0.54' 115 60 1 3250 1%ao 006-PNP 0.52 006-PNP(IFC) 0.57 Motor Type Permanent Split Capacitor,Impedance Protected NSF a-smart c �L us . NS%ANSI372 LISTED A Taco resource—saving product ANALOG TIMER OPTION: Application: Analog Features: The Plumb n' Plug with analog timer will cycle the circulator dur- a 24 Hour Analog Timer ing peak usage periods such as early morning or early evening.An a 15 Minute ON/OFF intervals optional aquastat is available for constant circulation applications . Easy-to-Use Clock Timer to maintain temperature between 95°F and 115oF.The Taco 003 PNP is ideal for recirculation loops.Its design operating condition • Factory installed 6' line cord of 3 gpm at 3 feet of head helps to reduce erosion,corrosion and noise in system piping. Use the 003 PNP for systems up to 200 total feet(supply and return) of'A" pipe.The Taco 005 and 006 PNP is designed for systems using 200-400 feet of 'A" pipe. Installation of isolation valves, pipe insulation and flow checks are recommended. Pump Dimensions&Weights: MODELS 003-PNP-and 006-PNP MODEL 005-PNP A A C—►1 B B D I 1 E — —— E o o . �� 3/a"MALE F F Eft.CORD THREAD Eft.CORD ANALOG TIMER MODEL CONNECTION A B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. mm IN. mm LBS. KG 003-BC4-PNP '/2"Sweat 2Y3 54 003-B4-PNP 3/a"Sweat 23/16 56 51/4134 7'/a 184 3'/ie 77.8 35/�s 84 003-ST4-PNP 3/a" FNPT 2 51 003-SC4-IPNP Union 23%2 76 6 152 005-SF2-PNP SS Flanged 8'/a 205 115/16 49 3%2 80 3%2 78.6 4% 121 6% 162 7.0 3.2 006-BC4-PNP 1/2"Sweat 2% 54 006-134-PNP 3/a"Sweat 23/,s 56 VA 134 7'/a 184 3'/16 77.8 Vii6 84 006-ST4-PNP 3/a"FNPT 2 51 006-SC4-1 PNP Union Z31I32 76 6 152 ANALOG TIMER with INTEGRAL FLOW CHECK(IFC)® MODEL CONNECTION A B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. mm IN. mm LBS. KG 003-BC4-3PNP Y2"Sweat 23/16 56 3Y16 77.8 5'/a 134 35/1s 84 003-BC4-2PNP 3/a"Sweat 005-SF2-1 PNP SS Flanged 8% 205 11 A6 49 3%2 80 3%2 78.6 43/a 121 6% 162 7.0 3.2 006-BC7-1 PNP 1/2"Sweat 006-BC7-PNP %"Sweat 23/18 56 3Y16 77.8F51/4 134 35/1s 84 DIGITAL TIMER OPTION: Application: Digital Features: The Plumb n' Plug with Digital Timer allows ON/OFF program . Digital Timer-7 Day Programmable settings to fit any homeowner's schedule.Multiple settings allow . Large LCD Display for different weekday/weekend run times.Run time intervals can . Easy-to-Use Program Buttons be set as short as 1 minute to maximize energy savings. Easy- . ON/OFF Intervals as short as 1 Minute to-Use clockface and large LCD display make settings a snap. Its onboard capacitor retains settings in memory for up to 2,500 '2,500 Hour Capacitor Backup, Saves Settings hours during power outages. An optional Aquastat is available for constant circulation applications to maintain temperature between 950F and 115°F.Taco 003 PNP is ideal for recirculation loops. Its design operating condition of 3 gpm at 3 feet of head helps to reduce erosion and noise in system piping.Use the 003 PNP for systems up to 200 total feet(supply and return) of 3/4" pipe. Installation of isolation valves pipe insulation and flow checks are recommended. Pump Dimensions&Weights: MODELS 003-PNP and 006-PNP A • B R0F I , C —— f E. I - 3/a MALE 6ft.CORD THREAD DIGITAL TIMER MODEL CONNECTION A B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. mm IN. mm LBS. KG 003-BC4-8PNP 'A"Sweat 21/8 54 003-134-213NP 3/4"Sweat 23/,s 56 5'/4 134 003-ST4-2PNP W FNPT 2 51 003-SC4-3PNP Union 23%2 76 6 152 7Ya 184 115/ts 49 3'/ts 78 3 16 84 7.0 3.2 006-BC4-4PNP '/2"Sweat 2'/8 54 006-134-2PNP W Sweat 23/,s 56 5'/4 134 006-ST4-2PNP 3/4" FNPT 2 51 006-SC4-3PNP Union 231/32 76 6 152 DIGITAL TIMER with INTEGRAL FLOW CHECK(IFC)® MODEL CONNECTION A - B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN. mm IN. mm LBS. KG 003-BC4-1 1 PNP '/z°Sweat 003-BC4-10PNP 3/a"Sweat 006-BC7-5PNP '/z"Sweat 8Ys 205 115/,e 49 23/,s 56 3'/,s 78 51/4134 35/,s 84 7.0 3.2 006-BC7-4PNP 1 3/4"Sweat LINE CORD ONLY OPTION: Application: For recirculation systems setup for constant circulation or with an optional aquastat control, use Plumb n' Plug®with line cord only.Simply plumb it in and plug it in.Taco 003 PNP is ideal for recirculation loops. Its design operating condition of 3 gpm at 3 feet of head helps to reduce erosion and noise in system piping. Use the 003 PNP for systems up to 200 total feet (supply and return)of 3/4" pipe. Installation of isolation valves, pipe insulation and flow checks are recommended. Pump Dimensions&Weights: MODELS 003-PNP and 006-PNP with LINE CORD ONLY A B� D C c o, I E I I a o, F LINE CORD ONLY MODEL CONNECTION A B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN, mm IN. mm LBS. KG 003-BC4-4PNP 1/2"Sweat 51/s 130 41/a 105 23/1s 56 41%2 112 003-134-1 PNP 3/4"Sweat 51/8 130 41/a 105 21/8 54 41/4 108 003-ST4-1 PNP %" FNPT 5% 143 47/a 124 2 51 4 102 003-SC4-2PNP Union 5%2 131 411/32 110 231/a2 76 515/1s 151 006-BC4-2PNP 1/2"Sweat 51/s 130 4% 105 23/1s 56 31/16 78 4'%2 112 3s/,s 84 6.5 2.9 006-134-1 PNP 3/4"Sweat 51/s 130 41/a 105 21/a 54 41/4 108 006-ST4-IPNP 3/4"FNPT 5% 143 41/a 124 2 51 4 102 006-SC4-2PNP Union 51/32 131 4t1/32 110 231/32 76 515/1s 151 LINE CORD ONLY with INTEGRAL FLOW CHECK(IFC)® MODEL CONNECTION A B C D E F SHIP WGT. IN. mm IN. mm IN. mm IN. mm IN, mm IN. mm LBS. KG 003-BC4-IPNP 1/2"Sweat 003-BC4-6PNP %"Sweat 6 152 4'/s 124 23/�s 56 275/is 75 43/e 111 3s/�s 84 6.5 2.9 006-BC7-3PNP 1/2"Sweat 006-BC7-2PNP 3/4"Sweat PERFORMANCE FIELD INFORMATION (60 Hz) DOMESTIC WATER RECIRCULATION MODELS(STD) FLOW-M'/H 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 12 3.5 11 - 1�- 003 10 005 3 � 006E 3.0 9 2 8 2.5 y WF 1Wi 7 W 2.0 = 6 0 2 5 1.5 F 4 1 O 3 1.0 2 0.5 1 F 71 00 2 4 6 8 10 12 14 16 18 200.0 FLOW-GPM DOMESTIC WATER RECIRCULATION MODELS(IFC) FLOW-M3/H 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 10 3.0 9 003-IFC 005-IFC 8 32 006B-IFC 2.5 7 N �i w uW 6 2.0 5 � p 4 1 1.5 F 3 2 1.0 1 00 2 4 6 8 10 12 14 16 18 200.5 FLOW-GPM Do your best work.® Printed in USA TACO,INC., 1160 Cranston Street,Cranston,RI 02920 Telephone:(401)942-8000 FAX:(401)942-2360. Copyright2014 TACO(Canada),Ltd.,8450 Lawson Road, Unit#3,Milton,Ontario L9T OJ8. Telephone:905/564-9422. FAX:905/564-9436. TACO,Inc. Visit our web site at:http://www.taco-hvac.com