Loading...
HomeMy WebLinkAboutWind Load Calculation File Copy _ Planning&Development Services Department �CF���D APB e Building&Code Regulations Division 0 7Z'g17 -- 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance Project Name: Dale Martucci Project Address: 4911 Paleo Pines Circle, Fort Pierce, FL 34951 Permit#: 1703-0101 Occupancy Type: U Construction Type:V-B INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. • Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) Residential 14 - 1. DESIGN CODE: Florida Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as(check one): X Enclosed Partially Enclosed Open 3. Risk Category: X 1 II III IV Exposure Category: B X C D 4. Design Wind Velocity 155 mph ASD X LRFD End Zone Width: 3 ft 5. Mean Roof Height 9-91 ft Roof Pitch: 5 &29 :12 Parapet: ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1:29 Zone 2: 50 Zone 3: 74 Zone 4:34 Zone 5:42 Garage: 7. Design Loads: Floor: 50 PSF Roof/Dead: 10 PSF Roof/Live: 20 Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: E 10. Design Soil Bearing PressurIATION 00 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTI STATEMENT: I certify that, to the be of knowledge and belief, the attached plans &specifications have been designed to comply wit he ap i bl tructural portions of the building codes currently adopted and enforced by St. Lucie County. I I o ce tha structural elements depicted-on these plans provide adequate resistance to the design forces sp i ied: - k \\`\ Nol If t /1 Richard J.Wills 76835 Print Name = Cert#&Co.Cert Auth. SF•%���� Tuff Shed, Inc. S+�natu ,Da e,Jrd Seal = 1777 S. Harrison St., Ste. 600, Denver, CO 80210 Company Name&Address TgTE op