Loading...
HomeMy WebLinkAboutProduct Approval (3) Florida Building Code Online COW. 1 of 2 KF M 9a ...�...a.,..,.......____..-.........._� ,,....,.,.._.._.�, f��'fa.s_�t�.•.� f.;3� l� .c'w,, ��s?..��i i'�.-.�,. BCIS Home j Log In User Registration 1 Hot Topics 1 Submit Surcharge 1 Stats&Fads `s Publications FBC Staff i BCIS Site Map Links Search bProduct Approval USER:Public User �.. �� Product Approval Menu>Product or Application Search>Application List>Application Detail C �tr�fJ FL# FL17667 : . x Application Type: New Code Version 2014 Application Status Approved Comments Archived ❑ Product Manufacturer Innovations Manufacturing, Inc. Address/Phone/Email 4555 Grape St. Denver,CO 80216 (303) 321-0945 obunker@innovationsmanuFacturing.com Authorized Signature Owen Bunker obunker@innovationsmanufacturing.com Technical Representative Owen Bunker Address/Phone/Email 455 Grape St. Denver, CO 80216 (303) 321-0945 obunker@innovationsmanufact u ring,com Quality Assurance Representative Owen Bunker Address/Phone/Email 4555 Grape St Denver, CO 80216 (303) 321-0945 obunker@innovationsmanufacturing.com Category Windows Subcategory Fixed Compliance Method Test Report Testing Lab Architectural Testing,Inc. -Florida Quality Assurance Entity Architectural Testing,Inc. Quality Assurance Contract Expiration Date 12/31/2018 Validated By Scott Wolters, PE Wj Validation Checklist- Hardcopy Received Certificate of Independence FL17667 R0 COI COI-Innovations Manufacturing 2014.odf Referenced Standard and Year (of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440-11 2011 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option B http://viww.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDgvFGYZsjrZFR... 4/10/2017 Florida Building Code Online Page 2 of 2 S,y Date Submitted 04/23/2015 Date Validated 04/26/2015 Date Pending FBC Approval 05/03/2015 Date Approved 06/22/2015 Summary of Products FL# Model, Number or Name Description 17667.1 IM Fixed Transom Window' Limits of Use Installation Instructions Approved for use in HVHZ: No FL17667 RO II E5100.01 stamped drawinos.pdf Approved for use outside HVHZ: Yes Verified By: Architectural Testing,Inc. -Florida Impact Resistant: No Test Reports Design Pressure: +50/-50 FL17667 RO TR e5100.01-401-44-r0.odf Other: Maximum size tested 72"wide by 12"tall.Approved protection required in windborne debris region. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-467-1824 The State of Florida is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to _supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: LM HE Credit Crird Safe http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEV X QwtDgvF GYZsj rZFR... 4/10/2017 PARTS LIST ITEM PARTNUMBER DESCRIPTION VENDOR 1 WALLASSEMBLY TUFF SHED 2 TRANSOM WINDOW INNOVATIONS MFG 3 WINDOWTRIM LOUISIANA PACIFIC A 4 .113#8 x 2 3/8"RING SHANK NAIL FASTENAL AS TESTED INSTALLATION NOTES: 1. WINDOW MUST BE INSTALLED INTO A SPF OR BETTER 2X WOOD MEMBER g g 2. WINDOW MUST BE INSTALLED USING 2"LONG,#8 ROOFING NAILS. ALL NAILS MUST BE SPACED A MAXIMUM OF 6"ON CENTER,THROUGH THE NAIL FIN INTO THE 2X WOOD MEMBER. A 3. ALL INSALLATION FASTENERS MUST BE LOCATED A MINIMUM OF 1/2" FROM THE EDGE OF THE NAIL FIN AND HAVE A MINIMUM EMBEDMENT OF 1-1/2".. 1-1/2" MIN EMBEDMENT #8 x 2"LONG 1/2" MIN 2X WOOD ROOFING NAILS � � EDGE BUCK 1/2" MIN DISTANCE (SPF min) EDGE —T DISTANCE 1-1/2"MIN 1/8" SHIM EMBEDMENT SPACE TRANSOM WINDOW 1/8" SHIM #8 x 2" LONG SPACE ROOFING.NAILS TRANSOM WINDOW SECTION A-A �( - � �Lto<tur.r Te�tina [�uildili tterTObether. B hEAD/SILL DETAILS WOOD SECTION B-B Test sa plecomplies with these details. BUCK JAMB DETAILS Deviations are noted. (SPF min) Report#: E5100.01-401-44 Date: 04/13/2015 Verified by: TUFF S}{E D Order#. Po* THESE DRAWINGS AND THE DRAWINGS BY: TITLE DRAWING NO. DESIGN ARE THE PROPERTY TUFF SHED,INC. Customer. Drawn By: PK OF TUFF SHED,INC.THESE INSTALLATION INSTRUCTIONS AP-FL-TRANSOM cBuildin s&Gara cs Date: 11/18/14 DRAWINGS A RE FORA Stora g g BUILDING TO BE SUPPLIED IN HOUSE S. HARRISONFHNG DEPARTMENT REV.LEVEL 01 TUFF SHED,INC. Site Address: AND BUILT BY TUFF SHED. 1777 S.H STREET FOR TRANSOM WINDOWS 6, rH.lmc"r.xi". Checked By: ANY OTHER USE IS DENVEIZ,COLORADO 80210 SHEET FORBIDDEN BY TUFF SHED MANUFACTURED BY Dale: (303)753-TUFF Building SiZe:wm"-�rw INC B THE ENGINEER OF TUFF SHED WG ASSUMESALL PESPONGIBNiH— INNOVATIONS MFG,INC Scale: N.T.S. RECORD. THE CONTE TOFTHESEDRA—GSA— E SHEET 1 OF 3 OF tHE aUILOIMG9 5"ONrt HERFN. Intertek - -- -- Architectural Testing z - f'.. TEST REPORT Report No.: E5100.01-401-44 Rendered to: INNOVATIONS MANUFACTURING, INC. Denver, Colorado PRODUCT TYPE: Transom Window SERIES/MODEL: IM SPECIFICATION(S): AAMA/WDMA/CSA 101/I.S.2/A440-11,NAFS 2011 -North American Fenestration Standard/Specification for Windows,Doors, and Skylights -Title Summa g of Results AAMA DMA/CSA 101 I.S.2 A440-11 Class R-PG50 1829 x 309 72.x 12 -TR Design Pressure ±2400 Pa ±50.13 pso Air Infiltration <0.1 L s m2 <0.01'cfm ft2 Water Penetration Resistance:Test Pressure 440 Pa (9.19 pso Test Completion Date: 02/11/15 This report contains in its entirety: `���,r►""" ��,,,�� Cover Page: 1 page �,�`��N P'.M :'P % Report Body: 5 pages J� �icEnrsF•.9�o ' Alteration Addendum: 1 page =* ; No.77418 Location Air Seal: 1 page STATE OF Drawing: 1 page o '•. :�``' ���•�` OR ID.." k �N150�0MFMDVUM - . 2015.04.23 16:17:11 =04'00' Reference must be made to Report No. E5100.01-401-44, dated 04/23%15'for complete test specimen description and detailed test results. 2250 Massaro Boulevard www.archtest.com www.intertek.com/building P 813.628.4300 Tampa, FL 33619. f. 717.764.4129 �I . I' Architectural Testing Test Report No.: E5100.01-401-44 Report Date: 04/23/15 Pagel of 5 i Report Issued To: Innovations Manufacturing, Inc. T 4555 Grape Street Denver, Colorado 80216 2.0 Test Laboratory: Architectural Testing, Inc. an Intertek company("Intertek-ATI") 2250 Massaro Boulevard Tampa, Florida 33619 813-628-4300 3.0 Project Summary: 3.1 Product Type: Transom Window 3.2 -Series/Model: IM 3.3 Compliance Statement: Results obtained are tested values and were secured by using the designated test method(s). .The specimen tested successfully met the performance requirements for a Class R-PG501829 x 309 (72 x 12)-TR rating. 3.4 Test Dates: 02/10/15 - 02/11/15 3.5 Test Record Retention End Date: All test-records for this report will be retained until February 11, 2019. 3:6 Test Location: Intertek-ATI test facility in Tampa, Florida. 3.7 Test Specimen Source: The test specimen(s) was .provided by the client. Y. Representative samples of the test sp'ecimen(s)will be retained by Intertek-ATI for a minimum of four years from the test completion date. 3.$.Drawing Reference: The test specimen drawings. have. been -reviewed by Intertek-ATI and are representative of the test specimen(s) reported herein..Test specimen construction was verified by Intertek-ATI per the drawings located in Appendix C. Any deviations are documented herein or on the drawings. 3.9 List of-Official Observers: Name Company Owen Bunker Innovations Manufacturing, Inc. - -- Wilferson Simbert Intertek-ATI Jt www.archtest.com www..intertek.com/building : I - AL Architectural Testing Test Report No.: E5100.01-401-44 Report Date: 04/23/15 Page 2 of 5 4.0 Test Specification(s): _ AAMA/WDMA/CSA 101/I.S.2/A440-11, NAFS 2011 - North American Fenestration Standard/Specification for Windows,Doors, and Skylights 5.0 Test Specimen Description: 5.1 Product Sizes: -Overall Area: Width Height 0.6 mz (6 ft2) millimeters inches millimeters inches Overall size 1829 72 305. 12 4. 5.2 Frame Construction: Frame Member Material Description Head,sill and Aluminum Extruded ambs Joinery Type Detail Each corner was sealed with sealant' and All corners Mitered and keyed secured with one inside aluminum.corner key with epoxy. 5.3 Weatherstripping: No weatherstripping was utilized. 5.4 Glazing: No conclusions of,any kind regarding the adequacy or inadequacy of the glass in anyglazed testspecimen(s)can be made. Glass T e Glazing Glazing Method Interior glazed against adhesive Monolithic 3 mm thick backed foam glazing tape and annealed glass secured with snap-in PVC glazing beads. Location Quantity Da li ht Opening Glass Bite millimeters inches Transom daylight 1' 1784 x 260 70-1/4 x 10-1/4 1/2" opening www.archtest..com www.intertek.com/building I i { f Ak Architectural Testing Test Report No.: E5100.01-401-44 Report Date: 04/23/15 Page 3 of 5 5.0 Test Specimen Description: (Continued)- 5.5 Drainage: No drainage was utilized. 5.6 .Hardware: No hardware was utilized. 5.7 Reinforcement: No reinforcement was utilized. 6.0 Installation: The specimen was installed into a 2x6 Southern Yellow Pine wood buck. The rough opening allowed for a 1/8" shim space. The exterior perimeter of the window was sealed with sealant. Location Anchor Description Anchor Location 3" from'.each corner and spaced 8" Head,sill and jambs 2"long roofing nails on center, through.the nail fin and trim board into the-wood buck 7.0 Test Results: The temperature during testing -was 19°C (67°F). The results are tabulated as follows: Title of Test Results Allowed Note Air Leakage, Infiltration per ASTM E 283 <0.1 L/s/m2 1.5 L/s/m2 at 75 Pa 1.57 s <0.01 cfm ff2 0:3 cfm ft2 max. 1 Water Penetration, per ASTM E 547 N/A N/A 2 Uniform Load Deflection, per ASTM E 330 N/A -N A 2 Uniform Load Structural, per ASTM E 330 NIA NIA 2 Forced Entry Resistance, per ASTM F 588, type: D -Grade: 10 Pass No entry www.archtest.com www.intertek.com/building ArcMt' e`i Testing - Test Report No.: E5100.01-401-44 _ Report Date: 04/23/15 Page 4 of 5 -7.0 Test Results: (Continued) Title of Test Results Allowed Note 0 tional Performance Water Penetration, per ASTM E 547 . at 440 Pa 9.19 pso Pass No leaka e 3 Uniform Load Deflection, per ASTM E 330 Deflections taken at the head +2400 Pa (+50.13 pso <0.3 mm (<0.01") -2400 Pa -50.13 pso 0.3 mm 0.01" Report Only 4,5, 6 Uniform Load Structural, per ASTM E 330 Permanent sets taken at the head +3600-Pa(+75.19 psf) 0.5 mm (0.02") 0.8'mm (0.03") max. -3600 Pa -75.19 pso 0.5 mm 0.02" 0.8 mm 0.03" max. 4, 5, 6 Note 1: The tested specimen meets (or exceeds) the performance levels specified in 4AMAIWDMAICSA 1011I.S.2/A440 for air leakage resistance. Note 2: The client opted to start at a pressure higher than the minimum required. Test results are reported under Optional Performance. Not e}3: Without insect screen. Note"4: The deflections reported are not limited byAAMA/WDMA/CSA 101/LS2/A440 for this product designation, The defection data is recorded in this report for special ` code compliance and information only. 6 Note S: Loads were held for 10 seconds, Note 6: Tape and film were not used to seal against air leakage during structural testing. i i i , i www.archtest.com www.intertek.com/building 3 S t E, Architectural Testing Test Report No.: E5100.01-401-44 Report Date: 04/23/15 Page 5 of 5 ! Intertek=ATI will service this report for the entire test record retention period. Test records such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation, will be retained by Intertek-ATI for the entire test record retention period. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s)-tested, This report may not be reproduced, except in full, without the written approval of Intertek-ATI. For ARCHITECTURAL TESTING, Inc. f Digitally Sigired by:DanioI P.Braun Digiblly Signed by:JP McDonald - Daniel P. Braun J.P. McDonald, P.E. Senior Vice President Director-Regional Operations VLM:vlm Attachments(pages): This report is complete only when all attachments listed are included. Appendix-A: Alteration Addendum(1) Appendix-B: Location of Air Seal(1) Appendix-C: Drawing(s)(1) . 1 a ' f This report produced from controlled document teinplate ATI 00438,revised 06/27/14. i 1 www.archtest.com www.intertek.com/building I A Test Report No.: E5100.01-401-44 I. R_ eport Date: 04/22/15 ij Architectural Testing - 4 f Appendix A Alteration Addendum Note: No alterations were required. • 1 www.archtest.com www.intertek.com/building b b i • b t - - ® Test Report No.: E5100.01-401-44 I Report Date: 04/22/15-__-_--�- — ---- 4i Architectural Testing - ----'--" — y 1` r Appendix B Location of Air Seal: The air seal between the test specimen and the test wall is detailed r below. The seal is made of foam weatherstripping and is attached to the edge of the*test specimen buck. The test specimen buck is placed against the test wall and clamped in place, compressing the weatherstripping and creating a seal. Test Wall Air Seai '(Weather6 ttpping) Test Specirhen Buck Test'Specimeri. a - 1 I ' 4 Li i www.archtest.com www.intertek.com/building a Interik Test Report No.: E5100.01-401-44 Architectural Testing Report Date: 04 22 15 . P i, I! FI G Appendix C Drawings) I I - o www.archtest.com www.intertek.com/buildin