FL# FL17588
Application Type New
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived ❑
Product Manufacturer Flood Solutions, LLC
Address/Phone/Email 1 Industrial Park Dr.
Bldg.27
Pelham,NH 03076
(603) 595-5222
info@floodsolutions.com
Authorized Signature Lori Malitsky
info@floodsolutions.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Panel Walls
Subcategory Wall Louver
Compliance Method Evaluation Report from a Product Evaluation Entity
Evaluation Entity ICC Evaluation Service, LLC
Quality Assurance Entity ICC Evaluation Service
Quality Assurance Contract Expiration Date 03/31/2018
Validated By ICC Evaluation Service, LLC.
Certificate of Independence FL17588 R0 COI Certificate of Independence for Evaluation.odf
Referenced Standard and Year(of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1612.5
Product Approval Method Method 2 Option A
Date Submitted 03/27/2015
r
http://www.floridabuilding.org/pr/Pr_app_dtl.a spx?param=wGEVXQWtDqvYdq2pQ%2fX... 4/10/2017
Florida Building Code Online _ Page 2 of 2
Date Validated 04/23/2015
Date Pending FBC Approval
Date Approved 04/25/2015
Summary of Products
FL# Model, Number or Name' Description
17588.1 FS FS-1412,FS-1608, FS-1616,FS-1608-HEX
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17588 RO II FS and FS HEX installation instructions.Ddf
Approved for use outside HVHZ: No Verified By: ICC Evaluation Service, LLC
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: FL17588 RO AE ICC Reoort.Ddf
17588.2 FS FS-1412,FS-1608, FS-1616,FS-1608-HEX
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17588 RO II FS and FS HEX installation instructions.Ddf
Approved for use outside HVHZ: Yes Verified By: ICC Evaluation Service, LLC
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: FL17588 RO AE ICC Reoort.Ddf
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
L
Credit hard'
Safe
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgvYdg2p Q%2fX... 4/10/2017
h INSTALLATION INSTRUCTIONS
MODELS:, fS AND .FS-HEX
ICC-ES CERTIFIED\- ENGINEERED
•
FEMA -COMPLIAN.T__FLOOD .VENTS------
What you'll need:
-1"Concrete/wood/metal.screws which is,dependent on what type of wall you will be fastening into'
-1"Anchors for concrete wall installation
-Power Drill
-1/4"Masonry Bit or 1/4"wood drill bit(dependent on what type of wall you will be fastening into)
-Screwdriver
-Hammer.
-Level
-Exterior Caulking
-Flashing,if needed,for an opening with a cavity in the wall(optional) µ_
INSTRUCTIONS:
***NOTE: BE SURE THAT BOTTOM OF OPENING IS LESS THAN 12"ABOVE THE ADJACENT GRADE.***
Step l:PROVIDE A CLEAN,SQUARE AND LEVEL ROUGH OPENING
'Stea 2:APPLY FLASHING AROUND THE INTERIOR OF THE WALL OPENING IF THERE IS A CAVITY IN THE WALL(optional)\
Step 3:LAYOUT THE VENT SO THE OPEN AREAS OF THE VENT HAVE A CLEAR OPENING BEHIND THEM.
-St_ ep:MAKE SURE VENT.IS LEVEL
Step 5:MARK HOLES ON WALL AND THEN.REMOVE VENT FROM OPENING
FOR-CONCRETE WALLS:Use Concrete Screws and Anchors
FOLLOW STEPS 1-5 ABOVE
Step S:DRILLHOLES 1-1/4"DEEP INTO CONCRETE/BLOCK WALL.
Step.6:FULLY INSERTANCHORS INTO WALL,TAPPING ANCHORS INTO PLACE,USING A HAMMER MAKINGSURE
•ANCHORS,ARE FLUSH TO THE WALL
Step&REPLACE VENT INTO OPENING
Step 9:SECURE ALL SCREWS THROUGH HOLES INVENT INTO ANCHORS SET IN WALL
Step 10:,CAULK AROUND PERIMETER OF VENT TO HELP PREVENT WATER FROM SEEPING
BEHIND THE FLANGE FRAME'
FOR WOOD WALLS:Use Wood Screws
-FOLWWSTEPS 1-5 ABOVE
Stea 5:DRILL,HOLES 1/2"DEEP INTO THE WOOD WALL
Step 6:REPLACE VENT OVER THEOPENING
Step 7:SECURE ALL SCREWS THROUGH HOLES IN VENT INTO THE WOOD WALL :
Step 8:CAULKAROUND PERIMETER OF VENT.TO HELP PREVENT WATER FROM SEEPING BEHIND THE FRAME
FOR INSTALLATION INTO DOORS:
FOLLOW STEPS 1-5 ABOVE .
Step 5:IF.THE'DOOR IS NOT A SOLID DOOR,USE ALUMINUM FLASHING AROUND THE PERIMETER OF THE,HOLE
Step.6:DRIVE•WOOD OR METAL SCREWS THROUGH_PREDRILLED HOLES.IN_V,ENTS-INTO-WOOD-FRAMING-- ---- -- -
- -Sten.7:CAULK AROUND PERIMETER OF VENT TO HELP PREVENT WATER FROM SEEPING
BEHIND THE_FLANGE FRAME'
FLOOD SOLUTIONS,-:LLC.
r
One Industrial Park Drive
+1► , , Bldg. 27
Pelham NH,03076
Toll Free:1-800-325-9775
`- In NH:'603-595-'5222 l
Fax:.603-595-4778
www.floodsolutions.com a
info@floodsolutio ns.com
�i
EVALUATION o e ' ' e e e e ' e
C
. SERVICE"
Repb r
,
E S t •
•
: �� .. i �
Min
DIVISION: 08 00 00—OPENINGS
SECTION:08 95 43—VENTS/FOUNDATION FLOOD VENTS
REPORT HOLDER:
FLOOD SOLUTIONS, LLC
ONE INDUSTRIAL PARK DRIVE, BUILDING 27
PELHAM, NEW HAMPSHIRE 03076
EVALUATION'SUBJECT:
STATIC FLOOD VENTS
7
ICC ICC. ICC H C 3
:`
.,
Pm
LISTED
Look for the trusted marks of Conformity!
"2024 Recipient of Prestigious Western States Seismic Policy Council
lNTRNAI#RM i
(WSSPC)Award in Excellence" A Subsidiary of coaE.auluie
- - SCCAur.drted �
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not C8-0J j
specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a C t
recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as _ n i
to any finding or'other matter in this report, or as to any product covered by the report. KIWZT,'r mm Ate + a
Copyright© 2015 t
INSTALLATION, .INSTRUCTIONS
M O.D E LS:- FS AND FS-HEX
ICC-ES CERTIFIED -:ENGINEERED
FEMA COMPLIANT FLOOD VENTS
What you'll need:
-1"Concrete/wood/metal screws which is dependent on what type of wall you will be fastening into
-1"Anchors for concrete will installation
-Power Drill
-1/4"Masonry Bit or 1/4"wood drill bit(dependent on what type of wall you.will be fastening into)
-Screwdriver
-Hammer
-Level
Exterior Caulking
-Flashing,if needed,for an opening with a cavity in the wall(optional)
INSTRUCTIONS:
***NOTE: BE SURE THAT BOTTOM OF OPENING IS LESS THAN 12"ABOVE THE ADJACENT GRADE.***
Step 1:PROVIDE A CLEAN,SQUARE-AND LEVEL ROUGH OPENING -
Step 2-.APPLY FLASHING AROUND THE INTERIOR OF THE WALL OPENING IF THERE IS A CAVITY IN THE WALL(optional)
Step 3:LAYOUTTHEVENT SO THE OPEN AREAS OF THE VENT HAVE A CLEAR OPENING BEHIND THEM.
Step 4:MAKE SURE VENT IS LEVEL
Step 5:MARK HOLES ON WALL AND THEN,REMOVE'VENT,FROM.OPENING
FOR CONCRETE WALLS: Use Concrete Screws and Anchors
FOLLOW STEPS 1-5 ABOVE
Step 5:DRILL HOLES 1-1/4"DEEP INTO CONCRETE/BLOCK WALL-.
Step 6:FULLY INSERT ANCHORS INTO WALL•,•TAPPING ANCHORS INTO PLACE USING A HAMMER MAKING SURE ,
ANCHORS ARE FLUSH TO THE WALL
Step 8:REPLACE VENT INTO OPENING
Step 9:SECURE-ALL SCREWS THROUGH HOLES IN VENT INTO ANCHORS SET IN WALL _
Step 10:CAULK AROUND PERIMETER OF VENTTO HELP PREVENT WATER FROM SEEPING
BEHIND THE FLANGE FRAME
FOR•WOOD WALLS: Use Wood Screws
FOLLOW STEPS 1-5 ABOVE_
Step 5:DRILCHOLES 1/2" DEEP INTO THE WOOD WALL ;
Step 6:REPLACE VENT OVER THEOPENING
Step 7:.SECURE ALL SCREWS THROUGH HOLES INVENT INTO THE WOOD WALL
Step 8:CAULK AROUND PERIMETER OF VENTTO HELP PREVENT WATER FROM SEEPING BEHIND THETRAME
FOR INSTALLATION INTO DOORS: '
FOLLOW STEPS 1-5 ABOVE
Step 5:IF THE DOOR IS NOT SOLID,DOOR,USE ALUMINUM'FLASHING'AROUND THE PERIMETER OF THE'HOLE
Step 6: DRIVE WOOD OR METAL SCREWS THROUGH PREDRILLED HOLES INVENTS INTO WOOD FRAMING
.Step 7:CAULK AROUND PERIMETER OF VENT TO HELP.PREVENTWATER FROM-SEEPING
BEHIND THE FLANGE FRAME
FLOOD SOLUTIONS,.LLC.
One Industrial Park Drive
* Bldg.'27
Pelham NH, 03076
Toll free: 1-800-325-9775
In NH: 603-595-5222
Fax:-603-595-4778
www.floodsolutions.com
info@floodsolutio ns.com
e
ICC EVALUATION
Atzn�7 SERVICE Most Widely.Accepted and Trusted
ICC-ES Evaluation Report ESR-3760 FBC Supplement
Issued March 2015.
This report is subject to renewal March 2016.
www-icc-es.ora 1.(800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council e
DIVISION: 08 00 00—OPENINGS
Section: 08.95 43=Vents/Foundation Flood Vents
REPORT HOLDER:
FLOOD SOLUTIONS,LLC
ONE INDUSTRIAL PARK DRIVE
BUILDING 27
PELHAM,NEW HAMPSHIRE 03076
(800)325-9775
www.floodsolutions.com
info(a)floodsolutions.corri
EVALUATION SUBJECT: .
STATIC FLOOD VENTS
1.0 REPORT PURPOSE AND SCOPE -
Purpose:
The purpose of this evaluation report supplement is to'indicate that Flood Solutions' flood vents, recognized in ICC-ES
master evaluation report ESR-3760, have also been evaluated for compliance with the codes noted below: ,
Applicable code editions:
■ 2014 Florida Building Code—Building(FBC)
■ 2010 Florida Building Code—Building(FBC)
iiii 2014 Florida Building Code—Residential(FRC)
■ 2010 Florida Building Code—Residential(FRC)
2.0 CONCLUSIONS
The Flood Solutions flood vents, described in Sections 2.0 through 7.0 of the master evaluation report ESR-3760, comply
with the FBC and the FRC,.provided the design and installation-are in accordance with the International Building Code
(IBC)provisions noted-in the master report.
Use of the,Flood Solutions' flood vents has also been found to be in compliance with the High-Velocity'Hurricane Zone
provisions of the FBC'and the FRC for structures not subject to 2010 FBC Section 2326.1 or 201.0 FRC 4409.13.3.1, as
applicable.
For products falling under Florida Rule 9N-3, verification that the report holders quality assurance program is audited by a
quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the
responsibility of an approved validation entity.(or the code official'when the report holder does not possess an approval by
the Commission).
This supplement expires concurrently with the master report, issued March 2015.
ICC-ES Evaluation Reports.are not to be construed as representing aesthetics or any other attributes not specifically addresser,nor are they to be construed N"
as an endorsement of the subject of the report or a recounnendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as
to any finding o•other matter in this,report,or as to any product covered by the report. 6"0i 1
Copyright©2015 Page 1 of 1
G
G g
-ee • s 1 W
s
DIVISION: 08 00 00—OPENINGS
SECTION: 08 95'43—VENTS/FOUNDATION FLOOD VENTS
REPORT HOLDER:
FLOOD SOLUTIONS, LLG
ONE INDUSTRIAL PARK DRIVE, BUILDING 27
PELHAM, NEW HAMPSHIRE 03076 _
EVALUATION SUBJECT:
STATIC FLOOD VENTS
q
ICG ICG Me...
.PNiG. LISTEa
Look for-the trusted marks of.Conformity! '=M
"2014.Recipient of Prestigious Western States Seismic Policy Council
r..nrs
(WSSPCJ Award in Excellence" A Subsidiary of 6oU NADj E
ICC=ES Evaluation Reports are not fo be construed as representing aesthetics..or any other attributes not
specifically-addressed, nor are they to be construed as an endorsement of the subject of the report or a
\\
recommendation for its use. There is no warranty by ICG Evaluation Service, LLC express or implied, as
,uzssaacieacim�nyr�c+ ocrs
to any finding or other matter in this report, or as to any product covered by the report.
Copyright© 2015
EVALUATION
Most Widely Accepted and Trusted
IMES Evaluation Report ESR-3760
Issued March 2015
This report is subject to renewal March 201.6.
www.icc-es.org 1 (800)423-6587 1 (562) 699-0643 A Subsidiary of the International Code Council e
DIVISION:08 00 00—OPENINGS for net free area for under-floor ventilation provided by
Section:08 95 43—Vents/Foundation Flood Vents each of Flood Solutions'static flood vents.
4.0 DESIGN AND INSTALLATION
REPORT HOLDER:
The Flood Solutions static flood vents are designed to be
FLOOD SOLUTIONS,LLC installed into walls or doors of existing or new construction
ONE INDUSTRIAL.PARK DRIVE from the exterior side. Installation of the vents must be in
BUILDING 27 accordance with the manufacturers instructions, the
PELHAM,NEW HAMPSHIRE 03076 applicable code and this report. In order to comply with the
(800)325-9775 engineered opening design principle noted in Section
www.floodsolutions.com 2.6.2,2 of ASCE/SEI 24, the vents must be installed as
info(@floodsolutions.com follows:
• With a minimum of-two opening on different sides of
EVALUATION SUBJECT: each enclosed area.
STATIC FLOOD VENTS With a minimum of one vent for'the square footage of
enclosed area noted in Table 1.
1.0. EVALUATION SCOPE Below the base flood elevation.
Compliance with the following codes: With the bottom of the vent located a maximum of
12 inches(305 mm)above grade.
■ 2015,2012 and 2009 International Building Code® 6.0 CONDITIONS OF USE
■ 2015,2012 and 2009 International Residential Code® The static flood vents described in this report comply with,
Property evaluated: or are a suitable alternative to what is specified in, those
Water flow codes listed in Section 1.0 of this report, subject to the
following conditions: !
2.0 USES
5.1 The static flood vents must be installed in accordance
Flood Solutions' static flood vents are used to provide for - with this report, the applicable code and the
the equalization of hydrostatic flood forces on exterior manufacturers installation instructions'In the event of
walls. a conflict,the instructions in'this report govern.
3.0 DESCRIPTION 6.2 The static flood vents must not be used in the place of
3.1 General "breakaway walls"'in coastal.high hazard areas, but
Flood Solutions' static flood vents are engineered,' are permitted for use in conjunction with.breakaway
walls in other areas.
permanently open flood vents with no moving parts that 6.0 EVIDENCE SUBMITTED
automatically allow flood waters to enter and exit enclosed
areas. The vents are constructed of aluminum 'and 6.1 Manufacturers descriptive literature and installation
available in four models. See Table 1 for model instructions:
designations and sizes. See Figure 1 for illustrations of the 6.2 Detail drawings.
flood vents. 6.3, Engineering calculations in accordance with
3.2 Engineered Opening: ASCE/SEI 24._
The Flood Solutions static flood vents comply with the 6.4 Quality documentation in accordance with the ICC-ES
design principle noted in Section 2.6.2.2 of ASCE/SEI 24 Acceptance Criteria. for Quality—Documentation
for a rate of rise and fall of 5 feet'per hour(0.423 mm/s).In (AC10), dated June 2014.
order to comply with the engineered opening requirement 7.0 IDENTIFICATION
of ASCE/SEI 24, the static flood vents must be installed in
accordance with Section 4.0 of this report. The Flood Solutions static flood vents recognized in this .
report must be identified by 'a label 'bearing the
3.3 Ventilation: manufacturer's name(Flood Solutions),,the model number,
Flood Solutions' static flood vents may be used to supply and the evaluation report number(ESR-3760).
natural ventilation for under-floor ventilation. See Table 1
]CC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addresser,,nor are they to be consinted
as an endorsement oflhe subject of the report or a reconnnendation for its use.There is no warranty by]CC Evaluation Service,LLC,express or implied,as
to any finding or ather matter in this report,or as to any product covered by the report
Copyright 0 2015 Page 1 of 2
ESR-3760 Most Widely Accepted and Trusted Page 2 of 2
TABLE 1—FLOOD SOLUTIONS STATIC FLOOD VENTS
ROUGH OPENING
VENT SIZE ENCLOSED �
SIZE NET FREE AREA
MODEL (Width x Height) (Width x Height) AREA COVERAGE (ins)
(in) in (ft)
FS-1608 18%x 10% 16 x 8 97 80.7
FS-1616 18%x 18'/2 16 x 16 191 158.2
: FS-1412 17 x 14% 14'/2 x 12 129 106.7
FS--1608-Hex 18'/2 x 10'/2 16 x 8 110 91.4
For SI: 1 inch=25.4 mm;1 ft=304.8 mm
'Available for use as under-floor ventilation.
fl
tS
tt a 7
s
s�
}
FS-1412 FS-1608
y
€t {d )
}
{r 11
' � f
FS-1616 FS-1608-HEX
FIGURE 1—FLOOD.SOLUTIONS STATIC FLOOD VENTS
File Co'py
Architectural Testing
MIAMI-DADE COUNTY
} PERFORMANCE TEST REPORT
Rendered to:
TUFF SHED,INC.
SERIES/MODEL: Premier and Sundance
PRODUCT TYPE: Side-Hinged Wood Double Shed Doors(Outswing)
This report contains in its entirety:
Cover Page: 1 page
Report Body: 14 pages
Sketches: 1 page
Drawings: 2 pages
Report No.: 77109.01-401-18
Test Dates: 10/17/07
Through: . 10/20/07
Report Date: 11/07/07
Expiration Date: 10/20/17
Miami-Dade County Notification No.: ATI FL 07021
2250 Massaro Blvd
Tampa, FL 33619
phone: 813-628-4300
fax: 813-628-4433
www.archtest.com
Architectural Testing
MIAMI-DADE COUNTY PERFORMANCE TEST REPORT
Rendered to:
TUFF SHED, INC.
1777 South Harrison Street, Suite 600
Denver, Colorado 80210
Report No.: 77109.01-401-18
Test Dates: 10/17/07
Through: . 10/20/07
Report Date: 11/07/07
Expiration Date: 10/20/17
Miami-Dade County Notification No.: ATI FL 07021
t _ Project Summary: Architectural Testing, Inc. was contracted by Tuff Shed, Inc. to perform
testing per Florida Building Code, Test Protocols for High Velocity Hurricane Zone, Protocol
TAS 202-94 on three(3) Series/Model Premier and three(3) Series/Model Sundance side-hinged
wood double shed doors (outswing). The samples tested met the performance requirements set
forth in the protocols for a ±54.6 psf Design Pressure rating (structural loads only).- Test
specimen description and results are reported herein. The samples were provided by the client.
Test Procedure: The test specimens were evaluated in accordance with the following:
TAS 202-94, Criteria for Testing Impact and Non Impact Resistant Building Envelope
Components Using Uniform Static Air Pressure Loading.
Drawing Reference: The test specimen drawings have been reviewed and verified by
Architectural Testing and are representative of the samples tested.
Test Specimen Description:
Test Specimen#1,#2 and#3:
Series/Model: Premier
Product Type: Side-Hinged Wood Double Shed Doors(Outswing)
Overall Size: 8' 5-3/4"wide by 7 0-1/4" high
Primary Panel Size: 3' 11"wide by 6' 8" high
Secondary Panel Size: 3' 11"wide by 6' 8" high
2250 Massaro Blvd
Tampa, FL 33619
phone: 813-628-4300
fax: 813-628-4433
www.archtest.com
1 �
77109.01-401-18
Architectural Testing Page 2of14
Test Specimen Description: (Continued)
Test Specimen#1,#2 and#3: (Continued)
Panel Construction: The doors were constructed with an interior sheet of 1/2" plywood
sheathing secured to a 1-1/2" square hollow steel door frame with #8 x 1-1/2" square drive
wood"screws located 6" on center and two (2) screws located at each end of every steel tube.
Next, a 15/32" DuratempTM plywood exterior sheathing was secured to the steel frame with
#8 x 1-1/2" square drive wood screws located 6" on center and two (2) screws at each end of
every steel tube. A 3-1/2" wide by 1/2" thick door trim was added to the exterior of the
panel and secured with exterior grade construction adhesive and 7/8" x 0.093" diameter ring
shank nails located 6" on center and two (2)nails at each end of every trim.
The exterior utilized two (2) hurricane spring bolts secured with four (4) #8 x 2-1/4" square
drive wood screws'located through the hurricane spring bolts into the wood panel at 6" from
top and bottom of secondary panels. The interior utilized stainless steel bolt latches secured
with two (2) #8 x 2-1/4" square drive wood screws and two (2) 1/4" x 3-1/2" carriage bolts
with lock washers and nuts.
Test Specimen#4,#5 and#6:
Series/Model: Sundance
Product Type: Side-Hinged Wood Double Shed Doors(Outswing)
Overall Size: 8'5-3/4"wide by TO-1/4" high
Primary Panel Size: 3' 11"wide by 6' 8" high
Secondary Panel Size: 3' 11"wide by 6' 8" high
Panel Construction: The doors were constructed of an interior sheet of 7/16" OSB
sheathing secured to a 1-1/2" square hollow steel door frame with #8 x 1-1/2" square drive
wood screws located 6" on center and two (2) screws located at each end of every steel tube.
- Next, a 3/8" thick LP SmartSide® exterior sheathing was secured to the steel frame with
#8 x 1-1/2" square-drive wood screws located 6" on center and two (2) screws at each end of
every steel tube.. A 3-1/2" wide by 1/2" thick door trim was.added to the exterior of the
w
panel and secured with exterior grade construction adhesive and 7/8" x 0.093" diameter ring
shank nails located 6" on center and two (2)nails at each end of every trim.
The exterior utilized two (2) hurricane spring bolts secured with four (4) #8 x 271/4" square
drive wood screws located through the hurricane spring bolts into the wood panel at 6" from
top.and bottom of secondary panels. The interior utilized stainless steel bolt latches secured
with two (2) #8 x 2-1/4" square drive wood screws and two (2) 1/4" x 3-1/2" carriage bolts
with lock washers and nuts.
Ak
/ 77109.01-401-18
Architectural Testing Page 3 of 14
Test Specimen Description: (Continued)
The following descriptions apply to all test specimens.
Frame Construction: The frame was constructed of Spruce-Pine-Fir #2 lumber. The
exterior face utilized a 3-1/2" wide by 1/2" thick door trim secured with 2-3/8" x 0.093"
diameter ring shank nails located 6" on center and two (2) nails at each end of every trim. A
7/16" receiving hole with a steel plate was added to the ceiling and floor at the interior bolt
latches.
Finish: All exterior wood was primed.
Hardware:
Description Quantity Location
Metal handle 1 Primary panel,40" from bottom
Metal hinges 3 per panel Bottom,top and midspan of panel
hinge stile
Spring loaded pin lock 2 Secondary panel,top and bottom of
lock keeper stile
Barrel bolt lock 2 Exterior of secondary panel 6" from
top and bottom of panel
Reinforcement: No reinforcement was utilized.
Installation: The panels were installed into a#2 Spruce-Pine-Fir wood:buck. The six metal
hinges (three [3] per panel) supported the panels and were secured to the wood buck with
four(4)#8 x 2-1/4" square drive wood screws through the hinges into the frame.
77109.01-401-18
Architectural Testing Page 4 of 14
Test Results: The following results have been recorded:
Protocol TAS 202-94,Static Air Pressure Tests
Test Unit#1 (Premier)
Design Pressure: ±54.6 psf
Title of Test Results
Indicator Readings (inch)
Structural Loads #1 #2 #3 #4 #5
50%of Test Pressure(+40.95 psf)
Maximum Deflection 0.22 0.98 0.20 0.20 0.07
Permanent Set 0.06 0.10 0.05 0.05 0.02
Design Pressure(+54.6 psf) 11
Maximum Deflection 0.33 1.17 0.25 0.23 0.09
Permanent Set 0.09 0.13 0.07 0.06 0.03
50%of Test Pressure(40.95 pso
Maximum Deflection 0.40 0.83 0.24 0.18 0.05
Permanent Set 0.01 0.11 0.02 0.02 0.01
Design Pressure (-54.6 psf)
Maximum Deflection 0.56 1.18 0.34 0.27 0.08
Permanent Set 0.02 0.20 0.05 0.05 0.01
Test Pressure(+81.9 pso
Maximum Deflection 1.23 1.38 0.32 0.31 0.11
Permanent Set 0.15 0.18 0.05 0.07 0.03
Test Pressure (-81.9 psf)
Maximum Deflection 1.04 2.07 0.49 0.41 0.12
Permanent Set 0.12 0.25 0.08 0.06 0.01
Note: See Architectural Testing, Inc. Sketch 91 for indicator-locations.
77109.01-401-18
Architectural Testing Page 5 of 14
Test Results: (Continued)
Protocol TAS 202-94,Static Air Pressure Tests
Test Unit#2 (Premier)
Design Pressure: ±54.6 psf
Title of Test Results
Indicator Readings(inch)
Structural Loads #1 #2 #3 #4 #5
50%of Test Pressure(+40.95 psf)
Maximum Deflection 0.32 0.54 0.10 0.07 0.03
Permanent Set 0.05 0.08 0.02 0.01 0.01
} Design Pressure(+54.6 psf) '
Maximum Deflection 0.48 0.84 0.14 0.12 0.05
Permanent Set 0.07 0.13 0.03 0.03 0.01
50%of Test Pressure(-40.95 psf)
Maximum Deflection 0.31 0.79 0.27 0.20 0.07
Permanent Set 0.09 0.14 0.03 0.04 0.01
Design Pressure(-54.6 psf)
Maximum Deflection 0.76 1.30 0.38 0.30 0.11
Permanent Set 0.14 0.21 0.07 0.06 0.02
Test Pressure(+81.9 psf)
Maximum Deflection 0.87 1.91 0.18 0.18 0.07
Permanent Set 0.10 0.16 0.02 0.03 0.02
Test Pressure (-81.9 psf)
Maximum Deflection 1.24 2.31 0.75 0.60 0.24
Permanent Set 0.35 0.40 0.27 0.12 0.06
Note: See Architectural Testing, Inc. Sketch V for indicator locations.
7710M I-401-18
Architectural Testing Page 6of14
Test Results: (Continued)
Protocol TAS 202-94,Static Air Pressure Tests
Test Unit#3 (Premier)
Design Pressure: ±54.6 psf
Title of Test Results
Indicator Readings(inch)
Structural Loads #1 #2 #3 #4 #5
50%of Test Pressure(+40.95 psf)
Maximum Deflection 0.26 0.69 0.18 0.15 . 0.02
Permanent Set 0.06 0.11 0.04 0.02 0.02
t Design Pressure (+54.6 psf)
Maximum Deflection 0.37 �0.95 0.22 0.19 0.11
Permanent Set 0.09 0.17 0.06 0.05 0.02
50%of Test Pressure(40.95 psf)
Maximum Deflection 0.53 0.97 0.34 0.27 0.15
Permanent Set 0.14 0..26 0.68 0.07 0.04
Design Pressure(-54.6 psf)
Maximum Deflection 0.69 1.28 0.45 0.37 0.21
Permanent Set 0.18 0.34 0.12 0.10 0.06
Test Pressure(+81.9 psf)
Maximum Deflection 0.67 1.49 0.32 0.29 0.17
Permanent Set 0.18, 0.34 0.10 0.10 0.06
Test Pressure (-81.9 psf)
Note: Top interior spring loaded pin lock released at 79.4 psf.
Remedial.work. Replaced interior spring loaded pin lock and changed the top lock
keeper to a larger steel plate with four(4) #8 x 1-1/2" square drive wood screws.
Note: See Architectural Testing, Inc. Sketch #1 for indicator locations..
J 77109.01-401-18
Architectural Testing Page 7 of 14
Test Results: (Continued)
Protocol TAS 202-94,Static Air Pressure Tests
Test Unit#3 (Premier) (Replacement)
Design Pressure: ±54.6 psf
Title of Test Results
Indicator Readings (inch)
Structural Loads #1 #2 #3 #4 #5
50%of Test Pressure(+40.95 psf)
Maximum Deflection 0.36 0.70 0.18 0.10 0.06
Permanent Set 0.07 0.16 0.04 0.03 0.02
` Design Pressure(+54.6 psf) t
Maximum Deflection 0.48 0.98 0.23 0.16 0.09
Permanent Set 0.09 0.23 0.06 0.05 0.03
50%of Test Pressure(-40.95 psf)
Maximum Deflection 0.38 0.63 0.27 0.11 0.06
Permanent Set 0.05 0.06 0.07 0.03 0.01
Design Pressure(-54.6 psf)
Maximum Deflection 0.54 0.97 0.42 0.17 0.11
Permanent Set 0.09 0.13 0.10 0.05 0.03
Test Pressure(+81.9 psf)
Maximum Deflection 0.70 1.71 0.26 0.17 0.13
Permanent Set 0.10 0.26 0.07 0.09 0.03
Test Pressure(-81.9 psf)
Maximum Deflection 0.85 1.64 0.68 0.27 0.20
Permanent Set 0.17 0.29 0.19 0.67 0.04
Note: See Architectural Testing, Inc. Sketch #1 for indicator locations.
77109.01-401-18
Architectural Testing Page 8 of 14
Test Results: (Continued)
Protocol TAS 202-94,Static Air Pressure Tests
Test Unit#4 (Sundance)
Design Pressure: ±54.6 psf
Title of Test Results
Indicator Readings(inch)
Structural Loads #1 #2 #3 #4 #5
50%of Test Pressure(+40.95 psf)
Maximum Deflection 0.24 0.64 0.12 0.09 0.04
Permanent Set 0.06 0.10 0.02 0.02 0.02
Design Pressure(+54.6 psf) '
Maximum Deflection 0.34 0.90 0.15 0.11 0.06
Permanent Set 0.10 0.15 0.03 0.03 0.02
50%of Test Pressure(40.95 psf)
Maximum Deflection 0.30 0.72 0.13 0.10 0.05
Permanent Set 0.02 0.07 0.01 . 0.02 0.01
Design Pressure(-54.6 pso
Maximum Deflection 0.48 1.07 0.21 0.17 0.08
Permanent Set 0.01 0.13 0.04 0.04 0.01
Test Pressure(+81.9 pso
Maximum Deflection 0.57 1.35 0.18 0.13 0.09
Permanent Set 0.14 0.18 0.03 0.03 0.02
Test Pressure(-81.9 psf)
Maximum Deflection 0.97 1.83 0.36 0.23 0.12
Permanent Set 0.10 0.17 0.05 0.02 0.01
Note: See Architectural Testing, Inc. Sketch 91 for indicator locations.
77109.01-401-18
Architectural Testing Page 9of14
Test Results: (Continued)
Protocol TAS 202-94,Statie Air Pressure Tests
Test Unit#5 (Sundance)
Design Pressure: ±54.6 psf
Title of Test Results
Indicator Readings(inch)
Structural Loads #1 #2 #3 #4 #5
506/o of Test Pressure(+40.95 psf)
Maximum Deflection 0.50 0.79 0.10 0.10 0.04
Permanent Set 0.12 0.18 0.05 0.04 0.01
Design Pressure (+54.6 psf) +
Maximum Deflection 0.75 1.26 0.17 0.14 0:05
Permanent Set 0.22 0.28. 0.07 0.06 0.01
50%of Test Pressure(40.95 pso
Maximum Deflection 0.44 0.76 0.12 0.12 0.07
Permanent Set 0.01 0.02 0.03 0.01 0.01
Design Pressure (-54.6 psf)
Maximum Deflection 0.59 0.76 . 0.13 0.12 0.10
Permanent Set 0.07 0.09 '0.05 0.02 0.02
Test Pressure(+81.9 psf)
Maximum Deflection 1.35 2.30 0.31 0.22 0.10
Permanent Set 0.44 0.52 0.15 0.09 0.04
Test Pressure(-81.9 psf)
Note: Top interior spring loaded pin lock released at 78.7 psf.
Remedial work. Replaced interior spring loaded pin lock and retest.
Note: See Architectural Testing, Inc. Sketch V for indicator locations.
``.
Ak
77109.01-401-18
Architectural Testing Page 10 of 14
Test Results: (Continued)
Protocol TAS 202-94,Static Air Pressure Tests
Test Unit#5 (Sundance) (Replacement)
Design Pressure: ±54.6 psf
Title of Test Results
Indicator Readings(inch)
Structural Loads #1 #2 #3 #4 #5
50%of Test Pressure(+40.95 psf)
Maximum Deflection 0.66 0.95 0.10 0.08 0.05
Permanent Set 0.22 0.23 0.04 0.01 0.01
Design Pressure(+54.6 psf) ;
Maximum Deflection 0.88 1.34 0.15 0.12 0.06
Permanent Set 0.26 0.29 0.05 0.03 0.02
50%of Test Pressure(-40.95 psf)
Maximum Deflection 0.54 0.66 0.11 0.10 0.04
Permanent Set 0.03 0.04 0.03 0.01 0.01
Design Pressure(-54.6 pso
Maximum Deflection 0.66 0.66 0.11 0.14 0.06
Permanent Set 0.08 0.10 0.01 0.03 0.01
Test Pressure(+81.9 psf)
Maximum Deflection 1.12 2.68 0.50 0.18 0.08
Permanent Set 0.34 0.47 0.10 0.05 0.04
Test Pressure(-81.9 psf)
Maximum Deflection 1.11 0.74 0.58 0.23 0.14
Permanent Set 0.19 0.29 0.08 0.12 0.03
Note: See Architectural Testing, Inc. Sketch #1 for indicator locations.
77109.01-401-18
Architectural Testing Page 11 of 14
Test Results:, (Continued)
Protocol TAS 202-94,Static Air Pressure Tests
Test Unit#6 (Sundance)
Design Pressure: ±54.6 psf
Title of Test Results
Indicator Readings(inch)
Structural Loads #1 . #2 #3 44 #5
50%of Test Pressure(+40.95.psf)
Maximum Deflection 0.35 0.90 0.66 0.09 0:08
Permanent Set 0.05 0.15 0.05, 0.01' 0.02
' Design Pressure(+54..6 psf) ' +
Maximum Deflection 0.43 1.12 0.87 0.17 0.09
Permanent Set 0.07 0.19 0.06 0.04 0.03
50%of Test Pressure(40.95 psf)
Maximum Deflection 0.38 0.74 0.14 0.08 0.07
Permanent Set 0.03 0.01 0.02 0.01 0.02
Design Pressure(-54.6 psf)
Maximum Deflection 0.51 1.03 u4 0.13 0.12
Permanent Set 0.05 0.05 - 0.03 0.03 0.03
Test Pressure(+81.9 psf)
Maximum Deflection 0.62 1.62 0.24 0.19 0.16
Permanent Set 0.16 0.34 0.09 0.07 0.06
Test Pressure(-81.9 psf)
Maximum Deflection 0.83 1.82 0.37 0.24 mg
Permanent Set 0.05 0.10 0.03 0.03 0.02
Note: See Architectural Testing, Inc. Sketch #1 for indicator locations.
77109.01-401-18
Architectural Testing Page 12 of 14
Test Equipment:
Pressurization System: Computer controlled centrifugal blower with electronic pressure
measuring device
Deflection Measuring Device: Linear transducers and 1" dial indicators
Laboratory Compliance Statements: The following is provided as required by the protocol for
the testing reported herein. ,
Upon completion of testing, specimens tested for TAS 202-94 met the requirements of
Section 1620 of the Florida Building Code,Building(2004).
Tape and film were used to seal against air leakage during structural testing. In our opinion,
the tape and film did not influence the results of the test.
Testing was conducted at the Architectgral Testing laboratory located in Tampa, Florida. ,
List of Official Observers:
Name Company
Jeff Cunningham Tuff Shed, Inc.
Owen Bunker Tuff Shed, Inc.
Scott Parker Architectural Testing, Inc.
Joseph A.Reed,P.E. Architectural Testing, Inc.
Mark A.Hess Architectural Testing, Inc.
Ak
77109.01-401-18
Architectural Testing Page 13 of 14
Detailed drawings,.data sheets, representative samples of test specimens, a copy of this report, or
other pertinent project documentation will be retained by Architectural Testing for a period of
ten years from the original test date. At the end of this retention period, such materials shall be
discarded without notice and the service life of this report will expire.
Results obtained are tested values and were secured by using the designated test methods.. This
report does not constitute certification of this product nor an opinion or endorsement by this
laboratory. It is the exclusive property of the client so named herein and relates only to the
specimens tested. This report may not be reproduced, except in full,without the written approval
of Architectural Testing.
For ARCHITECTURAL TESTING, INC.
D4*b11S9ned61r.M.*&Hrsv KA.Rmd
Mark A.Hess Joseph A.Reed,P.E.
Technician Director-Engineering and Product Testing
MAH:cmd
Attachments(pages): This report is complete only when all attachments listed are included.
Appendix-A: Sketches(1)
Appendix-B: Drawings(2)
Architectural DATE: IOU0101 PROJECT NO.11►09.01-401-l$ SHEET OF
Testing
BY: PROJECT NAME: C.
0.
,
C ,
e�CeS �tYlo �1
•
;
v
,
-
S e cie rc
v1a ve.
f.�
,
:
°.... .:.......:.... .. _.....
A r,
HURRICANE SPRING BOLT
ATTACH{1)HURRICANE BOLT 6"FROM TOP OF DOOR HANDLE AND STRIKE ! `
DOOR AND(11 6"FROM BOTTOM OF DOOR. /
ATTACH EACH BOLT WITH(4)#8 x 24/4"SQUARE INSTALL DOOR HANDLE PER 8
DRIVESCREWS MANUFACTURERS INSTRUCTIONS.USE 1G
O SINGLE DOOR ASSEMBLY #8 x 2-1/4"SQUARE DRIVE WOOD NYLOC 11
SCREWS,ATTACH STRIKE PLATE WITH(2)
TOP VIEW #B x 2'SQUARE DRIVE WOOD SCREWS. PARTIAL INSIDE VIEW PARTIAL END VIEW PARTIAL OUTSIDE VIEW WASHER DETAIL A'
swc:+.•r.+•a SCREWS TO BE LOCATED AS SHOWN.
/�rcli tecturULTest n i
BOLT LATCH ON FIXED DOOR FOR
DOUBLE DOOR Test snmplacchDlic s witli i9�t det ils. '"'�^ ' i
NAIL DOORJAMB STUDS TO KING ASSEMBLY NOTES: Deviativns are noted. !
STUDS WITH(2)12d @ 12-(NOT I3r, gyp)-)g SEE DETAIL'A'
SHOWN) 1. ATTACH ITEM 1(1/2-PLYWOOU7�l� FOR INSIDE VIEW i
SHEATHING)TO ITEM 2(STEEP 7 Tech- ``
�^ OF ASSEMBLY !1-1/2'SQ.TUBING)WITH ITEM 3(#8 x 1-1/2'
SCREWS)@'6"O.C.AND(2)SCREWS AT EACH 3 6
END OF EVERY STEEL TUBE AS SHOWN IN
HURRICANESPRINGBOLT DOOR SHEATHING DETAIL V.
ATTACH WITH((4)#8 x 2-1/4' EXTERIOR SHEATHING-112•DURATEMP 2. ATTACH ITEM 5(15132-PLYWOOD DURATEMP
SQUARE DRIV WOOD INTERIOR SHEATHING-112"PLYWOOD EXTERIOR SHEATHING)TO ITEM 2(STEEL 7
SCREWS. DOOR FRAME-1-112"SO.TUBING)WITH ITEM 3 1
DOUBLE DOOR ASSEMBLY (#ax1-1rz SCREWS)@m6"O.C.AND(2)SCREWS
TOP VIEW AT EACH END OF EVERY STEELTUBE AS .,!%
s w•-+w SHOWN IN DETAIL'S', f
3. ATTACH ITEM 6(DOOR TRIM)TO ITEM 6(15132-
BOLT LATCH ON FIXED PLYWOOD DURATEMP EXTERIOR SHEATHING r '
DOOR FOR DOUBLE DOOR WITH EXTERIOR GRADE CONSTRUCTION )
INSTALL EACH BOLT LATCH ADHESIVE AND ITEM 7(7I8'RING SHANK NAILS) j 3
WITH(2 08 x 2-1/4'TUFF @ 6"O.C.AND(2)NAILS AT EACH END OF
SHED HINGE SCREWS(PN HINGE ATTACHMENT EVERY TRIM PIECE AS SHOWN, 8 i
TS002)AND(2)1/4'x 3-112' !
CARRIAGE BOLTS W1 {3)TUFF SHED HINGES 4, INSTALL ITEM 8 F LOCKWASHERS AND NUTS- PER DOOR.ATTACH ITU F SHED'L"HANDLE) ,+
ORDER FROM TUFF SHED EACH HINGE WITH H THE DOOR'ASSEMBLY WITH(2)ITEM 9(#8 x I
PURCHASING DEFT, #8 x 2-114"TUFF SHED 2-114 SQUARE DRIVE SCREWS). INSTALL ITEM
HINGE SCREWS IPN 10(CAB LATCH)TO THE DOOR ASSEMBLY WITH j
Hi-rPUOORCM
ASING ORDER FROMPT. ITEM 11(98 x 1-114 PAN HEAD SCREWS). 2 1
DOORTHRESNOLD HINGES TO BE INSTALL WASHER AND NYLOCON HANDLE 2 i
LOCATED AS SHOWN, SHAFT. SEE DETAIL`A'.ALL ITEMS SHALL BE f i
INSTALLED PER MANUFACTURER'S 3
INSTRUCTIONS. 6 % 3
DOUBLE DOOR ASSEMBLY HINGE ASSEMBLY DETAIL
Zb SIDE VIEW FRONT VIEW ® E. LODED DOOR ASSEMBLY 1
sT/.iD:bVf••TY �CYi:Nr1'-YC ' �.
DETAIL'B' s
Ordet#. PO# THESE DRAWINGS AND THE DRAWINGS BY: TITLE DRAWING NO,
TUFF S}�E D DESIGN ARE D,I PROPERTY TUFF SHED,INC.Customer. Drawn By:CAD OF TUFFSHED,INC.THESE XYX-PGEN-01
Storage Buildings&Garages Dale: 10124107 ORAWINGSAREFORA SHED DOOR DETAILS
g g g Site Address: SOLOING TO BE SUPPLIED IN HOUSE DRAFTING DEPARTMENT TUFF SHED,INC. AND BUILT BY TUFF SHED. 1777 S.IIARRISON STREET PREMIER SERIES REV.LEVEL 01
Chocked By. ANY OTHER USE IS DENVER.COLORADO 80210
Da10: FORBIDDEN BY TUFF SIZED SHEET
ulldipp SI2e:worw.+ame•eemr-w.rt,Nsn INC d THE ENGINEER OF (303)753-TUFF
Scale; N.T.S.
RECORD. TUFFSHADM ASSWfSALLI+FSPMWjL"fCA I
n+F CDIrterA'DF TrreSF Dn!rFncs!lmn+F SHEET 1 OF 1 conaTauc++Dw DF THE euw,yos anw+w»+cea, y4
f
-r
1
I