Loading...
HomeMy WebLinkAboutCIMINO REVISION- ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 612/27/2020 3:55 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUTY ST LUCIE COUNTY VINCENT CIMINO CIMINO RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , 6702 DONLON ROAD Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 1439 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.51 75.00 ft² SHGC=0.22 Sgl, U=0.49 73.00 ft² SHGC=0.24 Sgl, U=0.45 3.00 ft² SHGC=0.26 N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1439.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1260.70 ft² b. Frame - Wood, Adjacent R=11.0 176.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Under Attic (Vented)R=30.0 1439.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:4.512 ft. Area Weighted Average SHGC:0.230 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 3 (151.0 sqft.) (1436.7 sqft.) (1439.0 sqft.) (1439.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 28.0 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 140 EF: 0.980 Glass/Floor Area: 0.105 Total Proposed Modified Loads: Total Baseline Loads: 47.75 50.62 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 12-28-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUTY ST LUCIE COUNTY 1 VINCENT CIMINO CIMINO RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1439 3 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FORT PIERCE , St. Lucie 6702 DONLON ROAD Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1439 11843.8 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 BEDROOM 3 131 1048 No 0 1 Yes Yes1 Yes 2 CLST 3 18 144 No 0 Yes Yes1 Yes 3 BATH 2 54 432 No 0 Yes Yes1 Yes 4 CLST 2 18 144 No 0 Yes Yes1 Yes 5 BEDROOM 2 132 1056 No 0 1 Yes Yes1 Yes 6 HALL 30 240 No 0 Yes Yes1 No 7 DINING 96 768 No 0 Yes Yes1 Yes 8 FOYER 24 192 No 0 Yes Yes1 Yes 9 KITCHEN/NOOK 265 2120 Yes 0 Yes Yes1 Yes 10 GREAT ROOM 266 2314.2 No 0 Yes Yes1 Yes 11 LAUNDRY 36 288 No 0 Yes Yes1 Yes 12 M BATH 98 784 No 0 Yes Yes1 Yes 13 M TOILET 30 240 No 0 Yes Yes1 Yes 14 M WIC 33 264 No 0 Yes Yes1 No 15 MASTER BEDROO 208 1809.6 No 0 1 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 131 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -023 ft BEDROOM 3 2 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3 3 54 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft BATH 2 12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 4 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2 5 132 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -028 ft BEDROOM 2 6 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 7 96 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -016 ft DINING 8 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft FOYER 9 265 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -013 ft KITCHEN/NOOK 10 266 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft GREAT ROOM 11 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -04 ft LAUNDRY 12 98 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft M BATH 13 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -04 ft M TOILET 14 33 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 15 208 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -029 ft MASTER BEDRO # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Composition shingles 1559 ft² Medium 0.3 0 22.62______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 1439 ft² N N150 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 131 ft² 0.1 Wood______BEDROOM 3 Batt 2 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 3 Batt 3 Under Attic (Vented)30 54 ft² 0.1 Wood______BATH 2 Batt 4 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 2 Batt 5 Under Attic (Vented)30 132 ft² 0.1 Wood______BEDROOM 2 Batt 6 Under Attic (Vented)30 30 ft² 0.1 Wood______HALL Batt 7 Under Attic (Vented)30 96 ft² 0.1 Wood______DINING Batt 8 Under Attic (Vented)30 24 ft² 0.1 Wood______FOYER Batt 9 Under Attic (Vented)30 265 ft² 0.1 Wood______KITCHEN/NOOK Batt 10 Under Attic (Vented)30 266 ft² 0.1 Wood______GREAT ROOM Batt 11 Under Attic (Vented)30 36 ft² 0.1 Wood______LAUNDRY Batt 12 Under Attic (Vented)30 98 ft² 0.1 Wood______M BATH Batt 13 Under Attic (Vented)30 30 ft² 0.1 Wood______M TOILET Batt 14 Under Attic (Vented)30 33 ft² 0.1 Wood______M WIC Batt 15 Under Attic (Vented)30 208 ft² 0.1 Wood______MASTER BEDRO Batt 12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0BEDROOM 3 00012 8N Concrete Block - Int Insul 0.30Exterior96.0 ft² ____ 2 4.1 0BEDROOM 3 00011 8W Concrete Block - Int Insul 0.30Exterior88.0 ft² ____ 3 4.1 0CLST 3 0002 8W Concrete Block - Int Insul 0.30Exterior16.0 ft² ____ 4 4.1 0BATH 2 0006 8W Concrete Block - Int Insul 0.30Exterior48.0 ft² ____ 5 4.1 0CLST 2 0002 8W Concrete Block - Int Insul 0.30Exterior16.0 ft² ____ 6 4.1 0BEDROOM 2 0005 8E Concrete Block - Int Insul 0.30Exterior40.0 ft² ____ 7 4.1 0BEDROOM 2 00012 8S Concrete Block - Int Insul 0.30Exterior96.0 ft² ____ 8 4.1 0BEDROOM 2 00011 8W Concrete Block - Int Insul 0.30Exterior88.0 ft² ____ 9 4.1 0DINING0004 8E Concrete Block - Int Insul 0.30Exterior32.0 ft² ____ 10 4.1 0DINING00012 8S Concrete Block - Int Insul 0.30Exterior96.0 ft² ____ 11 4.1 0FOYER0006 8S Concrete Block - Int Insul 0.30Exterior48.0 ft² ____ 12 4.1 0KITCHEN/NO 00013 8N Concrete Block - Int Insul 0.30Exterior104.0 ft² ____ 13 4.1 0GREAT ROO 08014 8N Concrete Block - Int Insul 0.30Exterior121.3 ft² ____ 14 4.1 0LAUNDRY0004 8W Concrete Block - Int Insul 0.30Exterior32.0 ft² ____ 15 11 0LAUNDRY0006 8S Frame - Wood 0.30.1Garage48.0 ft² ____ 16 4.1 0M BATH 0007 8E Concrete Block - Int Insul 0.30Exterior56.0 ft² ____ 17 11 0M BATH 0008 8S Frame - Wood 0.30.1Garage64.0 ft² ____ 18 4.1 0M TOILET 0004 8E Concrete Block - Int Insul 0.30Exterior32.0 ft² ____ 19 11 0M TOILET 0008 8S Frame - Wood 0.30.1Garage64.0 ft² ____ 20 4.1 0MASTER BE 08013 8N Concrete Block - Int Insul 0.30Exterior112.7 ft² ____ 21 4.1 0MASTER BE 08016 8E Concrete Block - Int Insul 0.30Exterior138.7 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .23 17.8 ft² None______S LAUNDRY 8682 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 W Low-E Single 0.49 0.24 15.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes2 N 2 W Low-E Single 0.45 0.26 3.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes4 N 3 S Low-E Single 0.51 0.22 15.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes7 N 4 S Low-E Single 0.51 0.22 20.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes10 N 5 S Low-E Single 0.49 0.24 20.0 ft² 5 ft 4 in 1 ft 4 in NoneMetal None______Yes11 N 6 N Low-E Single 0.49 0.24 15.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes12 N 7 N Low-E Single 0.51 0.22 40.0 ft² 11 ft 4 in 1 ft 4 in NoneMetal None______Yes13 N 8 E Low-E Single 0.49 0.24 8.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes18 N 9 E Low-E Single 0.49 0.24 15.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes21 N 12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 484 ft² 484 ft² 22 ft 8 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1381.8 775.81.000366Wholehouse .1278142.32Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 28 kBtu/hr 840 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 140 ft² Attic 14 ft² Default Leakage Attic (Default) c______1 1 (Default) c 12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 HALL Default(8 lbs/sq.ft.f t ² f t 0.3 DINING Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN/NOOK Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO 12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������