HomeMy WebLinkAboutCIMINO REVISION- ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 612/27/2020 3:55 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUTY
ST LUCIE COUNTY
VINCENT CIMINO
CIMINO RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL ,
6702 DONLON ROAD
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Detached
1
No
1439
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.51 75.00 ft²
SHGC=0.22
Sgl, U=0.49 73.00 ft²
SHGC=0.24
Sgl, U=0.45 3.00 ft²
SHGC=0.26
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1439.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1260.70 ft²
b. Frame - Wood, Adjacent R=11.0 176.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Under Attic (Vented)R=30.0 1439.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:4.512 ft.
Area Weighted Average SHGC:0.230
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(151.0 sqft.)
(1436.7 sqft.)
(1439.0 sqft.)
(1439.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
28.0 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 140
EF: 0.980
Glass/Floor Area: 0.105
Total Proposed Modified Loads:
Total Baseline Loads:
47.75
50.62 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
12-28-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUTY
ST LUCIE COUNTY
1
VINCENT CIMINO
CIMINO RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
1439
3
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
6702 DONLON ROAD
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1439 11843.8
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 BEDROOM 3 131 1048 No 0 1 Yes Yes1 Yes
2 CLST 3 18 144 No 0 Yes Yes1 Yes
3 BATH 2 54 432 No 0 Yes Yes1 Yes
4 CLST 2 18 144 No 0 Yes Yes1 Yes
5 BEDROOM 2 132 1056 No 0 1 Yes Yes1 Yes
6 HALL 30 240 No 0 Yes Yes1 No
7 DINING 96 768 No 0 Yes Yes1 Yes
8 FOYER 24 192 No 0 Yes Yes1 Yes
9 KITCHEN/NOOK 265 2120 Yes 0 Yes Yes1 Yes
10 GREAT ROOM 266 2314.2 No 0 Yes Yes1 Yes
11 LAUNDRY 36 288 No 0 Yes Yes1 Yes
12 M BATH 98 784 No 0 Yes Yes1 Yes
13 M TOILET 30 240 No 0 Yes Yes1 Yes
14 M WIC 33 264 No 0 Yes Yes1 No
15 MASTER BEDROO 208 1809.6 No 0 1 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 131 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -023 ft BEDROOM 3
2 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3
3 54 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft BATH 2
12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
4 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2
5 132 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -028 ft BEDROOM 2
6 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL
7 96 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -016 ft DINING
8 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft FOYER
9 265 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -013 ft KITCHEN/NOOK
10 266 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft GREAT ROOM
11 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -04 ft LAUNDRY
12 98 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft M BATH
13 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -04 ft M TOILET
14 33 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC
15 208 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -029 ft MASTER BEDRO
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Composition shingles 1559 ft² Medium 0.3 0 22.62______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 1439 ft² N N150
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented)30 131 ft² 0.1 Wood______BEDROOM 3 Batt
2 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 3 Batt
3 Under Attic (Vented)30 54 ft² 0.1 Wood______BATH 2 Batt
4 Under Attic (Vented)30 18 ft² 0.1 Wood______CLST 2 Batt
5 Under Attic (Vented)30 132 ft² 0.1 Wood______BEDROOM 2 Batt
6 Under Attic (Vented)30 30 ft² 0.1 Wood______HALL Batt
7 Under Attic (Vented)30 96 ft² 0.1 Wood______DINING Batt
8 Under Attic (Vented)30 24 ft² 0.1 Wood______FOYER Batt
9 Under Attic (Vented)30 265 ft² 0.1 Wood______KITCHEN/NOOK Batt
10 Under Attic (Vented)30 266 ft² 0.1 Wood______GREAT ROOM Batt
11 Under Attic (Vented)30 36 ft² 0.1 Wood______LAUNDRY Batt
12 Under Attic (Vented)30 98 ft² 0.1 Wood______M BATH Batt
13 Under Attic (Vented)30 30 ft² 0.1 Wood______M TOILET Batt
14 Under Attic (Vented)30 33 ft² 0.1 Wood______M WIC Batt
15 Under Attic (Vented)30 208 ft² 0.1 Wood______MASTER BEDRO Batt
12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0BEDROOM 3 00012 8N Concrete Block - Int Insul 0.30Exterior96.0 ft² ____
2 4.1 0BEDROOM 3 00011 8W Concrete Block - Int Insul 0.30Exterior88.0 ft² ____
3 4.1 0CLST 3 0002 8W Concrete Block - Int Insul 0.30Exterior16.0 ft² ____
4 4.1 0BATH 2 0006 8W Concrete Block - Int Insul 0.30Exterior48.0 ft² ____
5 4.1 0CLST 2 0002 8W Concrete Block - Int Insul 0.30Exterior16.0 ft² ____
6 4.1 0BEDROOM 2 0005 8E Concrete Block - Int Insul 0.30Exterior40.0 ft² ____
7 4.1 0BEDROOM 2 00012 8S Concrete Block - Int Insul 0.30Exterior96.0 ft² ____
8 4.1 0BEDROOM 2 00011 8W Concrete Block - Int Insul 0.30Exterior88.0 ft² ____
9 4.1 0DINING0004 8E Concrete Block - Int Insul 0.30Exterior32.0 ft² ____
10 4.1 0DINING00012 8S Concrete Block - Int Insul 0.30Exterior96.0 ft² ____
11 4.1 0FOYER0006 8S Concrete Block - Int Insul 0.30Exterior48.0 ft² ____
12 4.1 0KITCHEN/NO 00013 8N Concrete Block - Int Insul 0.30Exterior104.0 ft² ____
13 4.1 0GREAT ROO 08014 8N Concrete Block - Int Insul 0.30Exterior121.3 ft² ____
14 4.1 0LAUNDRY0004 8W Concrete Block - Int Insul 0.30Exterior32.0 ft² ____
15 11 0LAUNDRY0006 8S Frame - Wood 0.30.1Garage48.0 ft² ____
16 4.1 0M BATH 0007 8E Concrete Block - Int Insul 0.30Exterior56.0 ft² ____
17 11 0M BATH 0008 8S Frame - Wood 0.30.1Garage64.0 ft² ____
18 4.1 0M TOILET 0004 8E Concrete Block - Int Insul 0.30Exterior32.0 ft² ____
19 11 0M TOILET 0008 8S Frame - Wood 0.30.1Garage64.0 ft² ____
20 4.1 0MASTER BE 08013 8N Concrete Block - Int Insul 0.30Exterior112.7 ft² ____
21 4.1 0MASTER BE 08016 8E Concrete Block - Int Insul 0.30Exterior138.7 ft² ____
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .23 17.8 ft² None______S LAUNDRY 8682
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 W Low-E Single 0.49 0.24 15.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes2 N
2 W Low-E Single 0.45 0.26 3.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes4 N
3 S Low-E Single 0.51 0.22 15.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes7 N
4 S Low-E Single 0.51 0.22 20.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes10 N
5 S Low-E Single 0.49 0.24 20.0 ft² 5 ft 4 in 1 ft 4 in NoneMetal None______Yes11 N
6 N Low-E Single 0.49 0.24 15.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes12 N
7 N Low-E Single 0.51 0.22 40.0 ft² 11 ft 4 in 1 ft 4 in NoneMetal None______Yes13 N
8 E Low-E Single 0.49 0.24 8.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes18 N
9 E Low-E Single 0.49 0.24 15.0 ft² 1 ft 4 in 1 ft 4 in NoneMetal None______Yes21 N
12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 484 ft² 484 ft² 22 ft 8 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1381.8 775.81.000366Wholehouse .1278142.32Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 28 kBtu/hr 840 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 140 ft² Attic 14 ft² Default Leakage Attic (Default) c______1 1 (Default) c
12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 HALL
Default(8 lbs/sq.ft.f t ² f t 0.3 DINING
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN/NOOK
Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT ROOM
Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
12/27/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������