APPLICATION ENGINEERING
FOR HEATING AND COOLING
PALM HARBOR HOMES-PLANT 6/9
605 S. Frontage Rd.
Plant City, FL 33566
Manufacturer's Model#: 34OTL28562C
HVAC System Type: OVERHEAD GRAD FLEX FOR UP-FLOW(SPLIT A/C)
Prepared By LaSalle Air Systems 711WO14 (Method 8Output 20141
All rights reserved this infonnaSon proprietary to LaSalle Bristol Co.and PALM HARBOR HOMES-PLANT 619
Calculations on this page are based on design standards set forth in ASHRAE and ACCA Manuals J Rev 8.2 and D Rev 1.1. System registers are located
for best distribution based on Manual T.Design calculations are based on worst case orientation. Room loads may vary based on actual conditions.
ENTIRE HOUSE VALUES-DESIGN ZONE: 9 (HUD)30N Latitude
COOLING LOAD: 33,144 Btuh for Outside TempMumidity of 95 ° F(35 C)/47%and Inside reduced to 75 ' F(23 C)/50%
HEATING LOAD: 38,152 Btuh based on outside temp of 10 ° F(-13 C)with inside temp raised to 72 ° F(22 C)
OVERALL HEAT LOSS COEFFICIENT: 0.097 Crawlspace is not heated by the primary air handler.
CONSTRUCTION DETAILS&U/SHGC VALUES: (11+Non-ins Rim-17-33)
Total Cond.Floor Area: 1484.00 s.f. TRUE Outside Perimeter. 170.00 It
Level 1 Ceiling: 92.625 to 108 in. Level 2 Ceiling: 0 to 0 in. Level 3 Ceiling: 0 to 0 in.
Primary Wall Area: 1168.34 s.f.(Net) Dark Roof(U): 0.030 Net Roof Area(less duds): 1441.5 s.f.
Secondary Wall Area: 0.00 s.f.(Net) Prim Wall(U): 0.064 FLOOR DUCTS(U): 0.064
TOTAL Std window 108.50 s.f. Sec Wail(U): 0.032 ATTIC DUCTS(U): 0.238
TOTAL SGD-Shaded 40.00 s.f. Exp Floor(U): 0.086 F-)CT.DUCTS(U): 0.125
TOTAL Shaded 12.50 s.f. Std winds 1.060 /0.86 ATTIC DUCT AREA: 58.744 s.f.exposed
TOTAL Skylite 0.00 s.f. SGDSha 0.630 10.05 EXT.DUCT AREA: 0 s.f.exposed
TOTAL Doorl Area: 20.00 s.f. Shaded 1.060 /0.05 PEOPLE: 4 2960 Btuh Total Appliances
TOTAL Door2 Area: 0.00 s.f. Skylite 0.420 /0.34 FIREPLACES: 0
All Glass%of Floor. 10.85% Door-i: 0.480 DUCT'GAIN: @ Average 1735 Stuh @ 93 TD/48 TD
All Glass%of Wall: 11.93% Door 2: 0.670 DUCT LOSS: 2984 Btuh @ 117 TD
Mech.Ventilation per MHCSS 3280.103(b): 52 cfm Summer Infiltr(7.5 mph): 49.3 cfm
LATENT GAIN: 5154 Btuh Altitude: 40 It Winter Infiltration(15 mph): 93.0 cfm @ Average
ROOM BY ROOM VALUES: 1191.8 FPM, max velocity in trunk#: 2
Heat Exiting Furnace: 101 deg A/C Exiting: 50 deg 0.15 Max pressure at AIH
Actual heating and cooling required in each room and Cooling Air Heating Air Maximum A/C capacity
flow set to maximum of either heating or cooling Values for Values for 50 12.5 KW per MHCSS 3280.715
HEATING COOLING CFM 3 ton unit 90%Gas/Oil Elec Calibrated Blower Test
ROOM NAME LOSS(Btu) GAIN(Btu) DIST CFM Btuh CFM Btuh E Btuh Btuh(aft adj)
Living Room c 8,758 7,99E 276 279 7,803 263 9,754 9,245 11,695
Dining Area c 4,882 4,285 152 195 5,453 184 6,816 6,460 8,151
Kitchen c 3,990 3,638 129 146 4,080 138 5,100 4,834 6,136
Foyer h 1,319 787 38 - - - - -• -
Bath#1 h 1,323 798 38 48 1,358 46 1,698 1,609 2,051
Utility c 2,477 2,151 77 79 2,206 74 2,757 2,613 3,327
M.Bath h 2,476 1,538 71 101 2.817 95 3,521 3,337 4,243
M.Bedroom c 4,724 4,854 167 167 4,677 158 5,846 5,541 7,048
WIC h 1,763 1,111 50 39 1,096 37 1,370 1,299 1,655
Bedroom#2 c 3,386 3.093 109 118 3.312 112 4,140 3.924 4,951
Bedroom#3 c 3,056 2,895 102 112 3,145 106 3,931 3,726 4.701
TOTALS 38,152 33,144 1,209 1,283 35,947 1,213 44,934 42,587 53,957
COI TRACTOR'S COPY
FLORIDA ZONE II AND III LONGITUDINAL AND
LATERAL BRACING SYSTEMS PLACEMENT
For Roof slopes up to 4112 pitch
Each system is required to have a frame tie and stabilizer attached at each
lateral arm stabilizing location.
Revised: 6/17/2002
HOME DIMENSIONS REPRESENT BOX SIZE
LEGEND Lo ng i to d i n a I Longitudinal and Lateral o- Lateral Bracing
Bracing System "Bracing System System
o � a
xU E
0 � 0CD
m
� )
SINGLE AND DOUBLE WIDE SINGLEAND DOUBLE WIDE
UP TO 48'LONG-4 SYSTEMS 49'-76'LONG-6 SYSTEMS
52'INCLUDING HITCH 80'INCLUDING HITCH
FOR TRIPLE WIDE OR TAG UNITS- FOR TRIPLE WIDE OR TAG UNITS-
8 SYSTEMS OVER 57 BOXI 56'INCLUDING HITCH 6 SYSTEMS UP TO
52'BOX/56'INCLUDING HITCH
CONTYtACTOR'S COPY
6
LONGITUDINAL BRACE DETAIL FOR SD3 PIER PAD
OUTSIDE HOME BEAM
MMLBC BEAM CLIP
W/ ¢ Yxt XJ"
CARRIAGE BOLTS
h x2 4' NOTES
CARRIAGE BOLT
MAXIMUM PIER HEIGHT 49"
1)r 41 LONGITUMNIAL, MAX. SIDENNLL HEIGHT 136"
BRACE TUBE
39" FOR 12' TO 24" PIER MAX. BEAM SPACINGta9.5"
44" FOR 12" TO 32" PIER MAX ROOF EAVES 1'6'
53' FOR 12" TO 40" PIER
65' FOR 12' TO 48" PIER NOTE: 1/2' BOLTS ARE GRADE 5
h-4)" CARRIAGE BOLT WHEN USING LONGITUDINAL BRACES,
2ND PIER IN FROM THE END
OF THE HOT MAY BE USED
TO MAKE ROOD FOR BRACE 'PUBES,
SD3 PIER PAD
LONGITUDINAL & LATERAL BRACING SYSTEM
DETAIL ASSEMBLY DRAWING
>t�St4 µ�M Sul C
.. TERJ11. AINIt1STAIM
;:`,•�, GRACE T178E
-C.R.Cabdel . •""
i RqJWrediEngineer
Cup IC OR
OELUX STEEL
`°°a•,,P,...,iar''• WrdVE`
L0NGfTUDINAL UP
8RABE T M
STEEL PIER PAD
The Minute Man Anchors LLBS W/,ANGLE DRIVE
Bracing System was tested for PINS SD 3 PIN
Wind Zones I,II,&III
Tested 10/10/01
Rev.316102 3,150 lb.WORKING LOAD ANCHORS WITH STABILIZERS AND FRAME
R2V..7/14/04 TIES ARE REQUIRED ON 4 CORNERS OF ALL SINGLE WIDE HOMES.
Rev. ANCHOR STRAPS MAY BE INSTALLED WITH AN ANGLE AS LOW AS
2/10
45 DEGREES UP TO 90 DEGREES WHEN THEIR SOLE PURPOSE IS
Rev.1/1/15 VERTICAL ANCHORAGE.
CONTRACTOR'S CUP