Loading...
HomeMy WebLinkAboutProject Information I APPLICATION ENGINEERING FOR HEATING AND COOLING PALM HARBOR HOMES-PLANT 6/9 605 S. Frontage Rd. Plant City, FL 33566 Manufacturer's Model#: 34OTL28562C HVAC System Type: OVERHEAD GRAD FLEX FOR UP-FLOW(SPLIT A/C) Prepared By LaSalle Air Systems 711WO14 (Method 8Output 20141 All rights reserved this infonnaSon proprietary to LaSalle Bristol Co.and PALM HARBOR HOMES-PLANT 619 Calculations on this page are based on design standards set forth in ASHRAE and ACCA Manuals J Rev 8.2 and D Rev 1.1. System registers are located for best distribution based on Manual T.Design calculations are based on worst case orientation. Room loads may vary based on actual conditions. ENTIRE HOUSE VALUES-DESIGN ZONE: 9 (HUD)30N Latitude COOLING LOAD: 33,144 Btuh for Outside TempMumidity of 95 ° F(35 C)/47%and Inside reduced to 75 ' F(23 C)/50% HEATING LOAD: 38,152 Btuh based on outside temp of 10 ° F(-13 C)with inside temp raised to 72 ° F(22 C) OVERALL HEAT LOSS COEFFICIENT: 0.097 Crawlspace is not heated by the primary air handler. CONSTRUCTION DETAILS&U/SHGC VALUES: (11+Non-ins Rim-17-33) Total Cond.Floor Area: 1484.00 s.f. TRUE Outside Perimeter. 170.00 It Level 1 Ceiling: 92.625 to 108 in. Level 2 Ceiling: 0 to 0 in. Level 3 Ceiling: 0 to 0 in. Primary Wall Area: 1168.34 s.f.(Net) Dark Roof(U): 0.030 Net Roof Area(less duds): 1441.5 s.f. Secondary Wall Area: 0.00 s.f.(Net) Prim Wall(U): 0.064 FLOOR DUCTS(U): 0.064 TOTAL Std window 108.50 s.f. Sec Wail(U): 0.032 ATTIC DUCTS(U): 0.238 TOTAL SGD-Shaded 40.00 s.f. Exp Floor(U): 0.086 F-)CT.DUCTS(U): 0.125 TOTAL Shaded 12.50 s.f. Std winds 1.060 /0.86 ATTIC DUCT AREA: 58.744 s.f.exposed TOTAL Skylite 0.00 s.f. SGDSha 0.630 10.05 EXT.DUCT AREA: 0 s.f.exposed TOTAL Doorl Area: 20.00 s.f. Shaded 1.060 /0.05 PEOPLE: 4 2960 Btuh Total Appliances TOTAL Door2 Area: 0.00 s.f. Skylite 0.420 /0.34 FIREPLACES: 0 All Glass%of Floor. 10.85% Door-i: 0.480 DUCT'GAIN: @ Average 1735 Stuh @ 93 TD/48 TD All Glass%of Wall: 11.93% Door 2: 0.670 DUCT LOSS: 2984 Btuh @ 117 TD Mech.Ventilation per MHCSS 3280.103(b): 52 cfm Summer Infiltr(7.5 mph): 49.3 cfm LATENT GAIN: 5154 Btuh Altitude: 40 It Winter Infiltration(15 mph): 93.0 cfm @ Average ROOM BY ROOM VALUES: 1191.8 FPM, max velocity in trunk#: 2 Heat Exiting Furnace: 101 deg A/C Exiting: 50 deg 0.15 Max pressure at AIH Actual heating and cooling required in each room and Cooling Air Heating Air Maximum A/C capacity flow set to maximum of either heating or cooling Values for Values for 50 12.5 KW per MHCSS 3280.715 HEATING COOLING CFM 3 ton unit 90%Gas/Oil Elec Calibrated Blower Test ROOM NAME LOSS(Btu) GAIN(Btu) DIST CFM Btuh CFM Btuh E Btuh Btuh(aft adj) Living Room c 8,758 7,99E 276 279 7,803 263 9,754 9,245 11,695 Dining Area c 4,882 4,285 152 195 5,453 184 6,816 6,460 8,151 Kitchen c 3,990 3,638 129 146 4,080 138 5,100 4,834 6,136 Foyer h 1,319 787 38 - - - - -• - Bath#1 h 1,323 798 38 48 1,358 46 1,698 1,609 2,051 Utility c 2,477 2,151 77 79 2,206 74 2,757 2,613 3,327 M.Bath h 2,476 1,538 71 101 2.817 95 3,521 3,337 4,243 M.Bedroom c 4,724 4,854 167 167 4,677 158 5,846 5,541 7,048 WIC h 1,763 1,111 50 39 1,096 37 1,370 1,299 1,655 Bedroom#2 c 3,386 3.093 109 118 3.312 112 4,140 3.924 4,951 Bedroom#3 c 3,056 2,895 102 112 3,145 106 3,931 3,726 4.701 TOTALS 38,152 33,144 1,209 1,283 35,947 1,213 44,934 42,587 53,957 COI TRACTOR'S COPY FLORIDA ZONE II AND III LONGITUDINAL AND LATERAL BRACING SYSTEMS PLACEMENT For Roof slopes up to 4112 pitch Each system is required to have a frame tie and stabilizer attached at each lateral arm stabilizing location. Revised: 6/17/2002 HOME DIMENSIONS REPRESENT BOX SIZE LEGEND Lo ng i to d i n a I Longitudinal and Lateral o- Lateral Bracing Bracing System "Bracing System System o � a xU E 0 � 0CD m � ) SINGLE AND DOUBLE WIDE SINGLEAND DOUBLE WIDE UP TO 48'LONG-4 SYSTEMS 49'-76'LONG-6 SYSTEMS 52'INCLUDING HITCH 80'INCLUDING HITCH FOR TRIPLE WIDE OR TAG UNITS- FOR TRIPLE WIDE OR TAG UNITS- 8 SYSTEMS OVER 57 BOXI 56'INCLUDING HITCH 6 SYSTEMS UP TO 52'BOX/56'INCLUDING HITCH CONTYtACTOR'S COPY 6 LONGITUDINAL BRACE DETAIL FOR SD3 PIER PAD OUTSIDE HOME BEAM MMLBC BEAM CLIP W/ ¢ Yxt XJ" CARRIAGE BOLTS h x2 4' NOTES CARRIAGE BOLT MAXIMUM PIER HEIGHT 49" 1)r 41 LONGITUMNIAL, MAX. SIDENNLL HEIGHT 136" BRACE TUBE 39" FOR 12' TO 24" PIER MAX. BEAM SPACINGta9.5" 44" FOR 12" TO 32" PIER MAX ROOF EAVES 1'6' 53' FOR 12" TO 40" PIER 65' FOR 12' TO 48" PIER NOTE: 1/2' BOLTS ARE GRADE 5 h-4)" CARRIAGE BOLT WHEN USING LONGITUDINAL BRACES, 2ND PIER IN FROM THE END OF THE HOT MAY BE USED TO MAKE ROOD FOR BRACE 'PUBES, SD3 PIER PAD LONGITUDINAL & LATERAL BRACING SYSTEM DETAIL ASSEMBLY DRAWING >t�St4 µ�M Sul C .. TERJ11. AINIt1STAIM ;:`,•�, GRACE T178E -C.R.Cabdel . •"" i RqJWrediEngineer Cup IC OR OELUX STEEL `°°a•,,P,...,iar''• WrdVE` L0NGfTUDINAL UP 8RABE T M STEEL PIER PAD The Minute Man Anchors LLBS W/,ANGLE DRIVE Bracing System was tested for PINS SD 3 PIN Wind Zones I,II,&III Tested 10/10/01 Rev.316102 3,150 lb.WORKING LOAD ANCHORS WITH STABILIZERS AND FRAME R2V..7/14/04 TIES ARE REQUIRED ON 4 CORNERS OF ALL SINGLE WIDE HOMES. Rev. ANCHOR STRAPS MAY BE INSTALLED WITH AN ANGLE AS LOW AS 2/10 45 DEGREES UP TO 90 DEGREES WHEN THEIR SOLE PURPOSE IS Rev.1/1/15 VERTICAL ANCHORAGE. CONTRACTOR'S CUP