FL #
FL27499-RI
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 32D1 SE Dominica Terace
Stuart, FL 34997
(772) 872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Walters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Tnc.
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Lucas A. Turner, P.E., MBA
i Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL27499 R1 COI Dyn C01Off
Standard
Year
TAS 100
1995
TAS 110
2003
TAS 125
2003
httpsJlwww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe°/a2bOsCepABg3%2bkM6B4KrS3X7m7RLNDTr%2fv7QaQ%3d%... 1/4
4/10/2020 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL #
................ ...
27499.1
Model, Number or Name
..__._...................................................................................-.
DM Class 1000 1" Nailstrip
Limits of Use
Approved for use in HVHZ. Yes
Approved for use outside HVHZ: Yes
Impact Resistant. N/A
Design Pressure: N/A
Other: Please see Eva[ report for Limits of Use
27499.2 DM Class 1000 1" Nailstrip,
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eva] report for Limits of Use.
02/22/2019
08/29/2019
08/30/2019
10/15/2019
27499.3 DM Class 1050 1 1/2" Nailstrip
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eva] report for Limits of Use,
27499.4 1 DM Class 1050 1 1/2" Nailstrfp
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.5 DM Class 1500 1 1/2" Mechanical
Seam
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use
27499.6 DM Class 1500 1 1/2" Mechanical
Seam
Limits of Use
Approved for use in HVHZ; Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.7 DM Class 1500 1 1/2" Mechanical
Seam
Description
..._,_ ............................... ................ ........._ w
26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Installation Instructions
FL27499 R1 II NSSI6HZ.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R1 AE DM Evall.pdf
Created by Independent Third Party: Yes
.032" Aluminum roof panel, 16" wide, with 1" snap f€t seams.
Installation Instructions
FL2749 R1 II NSAI6HZ.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 Rl AE DM Eva12.pdf
Created by Independent Third Party: Yes
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Installation Instructions
FL27499 RI II NSAI9HZ.pdf
Verified By: Scott Wolters, P.E. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R1 AE DM Eval3,1df
Created by Independent Third Party: Yes
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap fit seams
Installation Instructions
FL27499 R1 II NSSI9HZ.pdf
Verified By; Scott Wolters, P.E. FLPE# 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R1 AE DM Eval4.p ff
Created by Independent Third Party: Yes
.032" Aluminum roof panel, 20" wide, with 1 1/2" standing
seams.
Installation Instructions
FL27499 R1 II 15MS620HZ.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party; Yes
Evaluation Reports
FL27422 R1 AE DM Eval5.pdf
Created by Independent Third Party: Yes
16 oz. Copper roof panel, 16" wide, with 1 1/2" standing
seams,
Installation Instructions
FL27499 R1 II 15MSCHZ.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party; Yes
Evaluation Reports
FL27499 R1 AE DM Eval6.pdf
Created by Independent Third Party: Yes
26 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2"
standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Installation Instructions
FL27499 R1 II 15MSS1626HZ.pdf
Verified By: Scott Wolters 62354
https:llwww.#loridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCepABg3%2bkM6i34KrS3X7m7RLNDTr%2fv7QaQ%3d%... 2/4
ENGINEERING, DRAFTING, CONSULTING
15211 971h Road N
West Palm Beach, FL 33412
PhIFx: (561) 225-1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 1050 .032" ALUMINUM 1%" NAILSTRIP 19" WIDE
ROOF PANEL (FLPA# 27499.3)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 1050 Series .032" Aluminum 1 Y2" Nailstrip 19" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural Fluropon coated aluminum roof panes (25 ksi min) that meets the requirements of
Sections 1507A and 1518.9 of the 6$ Edition (2017) Florida Building Code. The panel has been tested per TAS
100 and TAS 125 by Intertek with results shown in test reports G3443.31-450-44 and G3443.17450-44, and per
TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-02-01 and VLS-
005-02-01,
Technical Documentation:
1. Drawing "NSA19-HZ" dated 8/15/19, signed and sealed by Scott Wolters, PE.
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE, and
by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE,
3. Supplemental Calculations to support "NSA19-HZ" drawing, signed and sealed by Scott Walters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions,
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 19" (nominal)
Fastener Spacing across panel: 19" (at Nailstrip)
(Panels overlap with male/female snap fit)
Min. Slope: HVHZ: 2"112"
Non-HVHZ: '/2'112" (Lap Sealant Req'd
— See Chart)
Tr,'CIPbON6 IN IMFAC CkPfA1N'AJg15, 5T0FFFI20N(5, & WINOOW5
Field
Installation
Perimeter & Corner
Installation
Max. Design Pressure:
-168 psf
-168 psf
Fastener Spacing:
3" From Ends, 6" Max. O.C.
3" From Ends, 6" Max. O,C,
Min Panel Fasteners:
#10x1" Panclip Fasteners
#10x1" Panclip Fasteners
Panel Sealant:
Continuous bead of Geocel 2300
or 2320 on both sides of seam
Continuous bead of Geocel 2300
or 2320 on both sides of seam
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions,
Underlayment: Minimum ASTM D 226 Type II with 4" overlaps and 6" end -laps, anchored
with 12 Ga, x 1 %" galvanized roof nails with 32 Ga. Tin caps spaced 6"
O.C. in rows at the perimeter, at overlaps, and two intermediate rows
staggered and spaced 12" O.C.
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, 1" round plastic caps may be used to prevent
galvanic reactions.
Minimum Substrate: ''/z' (15/32" min) 4-ply CDX Plywood, nailed to 2x rafters spaced 24" max.
O.Cl with 8d ring -shank nails spaced 4" O.C.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
15152.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. Rational analysis, provided by a Florida licensed Amhitect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction,
5. All panels shall be permanently labeled with the manfacturer's name
and/or logo, and the following statement, "Dynamic Metals
FL# 27499.3, DM Class 1050".
5FFCIA[ 0N6 IN WrACr F-r55TAN1' CT,1'AUNNJ 5, 5T0PffV0NC5, & WNPOWS
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 3rd party QA provider, to the dimensions shown on Drawing NSA19-HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSQ-45,60616 SSQ-8681118
5VC-049071.8 5VC-0360516 5VC-0521218
Re -Roofing. The DM Class 1050 Series 032": Aluminum 11/2" Nailstrip 19"Wide Roof Panel
may be installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1521 (HVHZ) or Section 11511 (outside of HVHZ) of the
Florida Building Code,
If you have any questions or need more information concerning this approval please contact me,
Thank you,4ti
-� VV ot
-.f/""
........
05 E
s'
No 62354
Scott Wolters
FL PE# 62384
STATE OF 411
NUG1 6 M19
0 R
NM�
m11W
a'T'ov",- ".,PON 5' F,
assz
�uAAl Isil
�� s N �a zr isBSI',Avj Ml; F ,7 1 its LS�J:
m 3 1 Cie LIZ fvul)
vas cx�c�r, �=srss i _w.