Loading...
HomeMy WebLinkAboutHealth Dept Final ApprovalSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: James Jurek AGENT: Dave Golden (Dave Golden Homes) PROPERTY ADDRESS: 5315 Tree Top Trl Fort Pierce, FL 34951 LOT: BLOCK: APPLICATION #:AP1478340 PERMIT #:56-SF-2054790 DOCUMENT # : FI 1558850 DATE PAID.04/10/2020 FEE PAID:660.00 RECEIPT #:56-PID-4355048 SUBDIVISION: ID # : 1407-342-0040-000-5 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER FT [ ] [02] TANK MATERIAL Polypropylene [ ] [281 DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS 92 FT [ ] [04] MULTI -CHAMBERED [LIJ N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER PolylokPL-68 [ ] [31] IRRIGATION WELLS FT [ ] [ 0 6 ] LEGEND 1. 70-143-11 DC4 2. [ ] [ 32 ] POTABLE WATER 62 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 8 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 28 FT [ ] (09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 509.4 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 5.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 26.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] 46 LOCATION CONFORMS WITH SITE PLAN FINAL OTMV GRADING FILL / EXCAVATION MATERIAL [ ] [ ] [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [231 FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / DISAPPROVED ]: St. Lucie CHD J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]:2S. St. Lucie CHD Envi onmental Speci 1st II Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1478340 EID2054790 DATE: 12/11 /2020 DATE: 12/28/2020 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1478340 PERMIT #:56-SF-2054790 DOCUMENT # : FI 1558850 DATE PAID:04/10/2020 FEE PAID:660.00 RECEIPT # :56-PI D-4355048 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST, filter, and 5x9 long BED DF installed. Well not installed in correct location. Needs copy of corrected survey. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for filled system, site plan conformity, and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1478340 EID2054790