Loading...
HomeMy WebLinkAboutCertification for Design Load ComplianceRECEI`.'rD APR 0 7.017 Planning & Development Services Department • Building & Code Regulations Division - - --- - 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Ciuperger 2016.231 Project Address: 15370 Skyking Dr., Port St. Lucie, FL 34986 Permit #: 1703-0247 Occupancy Type: Single Family Construction Type: Residential INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or mufti -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida FBC Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: X B C - D 4. Design Wind Velocity 160 mph ASD LRFD End Zone Width: ft 5. Mean Roof Height 18.47 ft Roof Pitch: 6 :12 Parapet: = ft = -� 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):"c.kX ,Ff �1010 Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: fi.Z,7� PSf 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,000 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: that, to the best of my knowledge and belief, the attached plans & specifications have been designed to 72•.Lr J- _ _..j Fr comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie ,County I also certify that structural elements depicted on these plans provide adequate resistance to the design �,f f y4fr rcesspecif ed.,d°,_' ff, Edward F. Shinskie PE # 47515 r Print Name Cert # & Co. Cert Auth. 7_ RKE Enterprises LLC _ �T 'Sign ature, Date, and Seal 4707 Wild Turkey Rd, Mims, FL 32754F1 COPY, Company Name & Address EF:, a,.,,, -Revised 07/25/2014