Loading...
HomeMy WebLinkAboutProduct Approval (7) Florida Building Code Online A Page 1 of 3 i &-'PrdessidnalReguliflon BCIS Home I Log In User Registration Hot Topics I Submit Surcharge Stats&Facts i Publications I FBC Staff BCIS Site Map { Links I Search Florida Product Approval .I R USER:Public User w+�rd m Product Aooroval Menu>Product or Aoolication Search>Aoolication List>Application Detail FL# FL11698-113 Application Type Revision Code Version 2014 Application Status Approved Comments Archived ❑ Product Manufacturer Englert Inc. Address/Phone/Email 1200 Amboy Ave. Perth Amboy,NJ 08861 (732)826-8614 Ext3909 j.tripod@englertinc.com Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Joseph F.Tripod Address/Phone/Email 1200 Amboy Avenue Perth Amboy,NJ 08862 (732)826-8614 jftripod@aol.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the James L.Buckner,P.E @ C-Buck,Inc. Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/31/2019 Validated By Steven M.Urich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL11698 R3 COI CertOflndep,pdf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL 1897 2004 UL 580 2006 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL116 8 R3 Eciuiv Test Standard E uiv. df Sections from the Code FILE COPY https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f fr... 4/7/2017 Florida Building Code Online Page 3 of 3 Limits of Use Installation Instructions Approved for use in HVHZ:No FI 11698 R3 II 6 S1101 241. WoodDeck EVALREPORT Ddf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-165 max. Evaluation Reports Other: Refer to,Evaluation Report for FL11698 R3 AE 6 S1101 24oa WoodDeck EVALREPORT Ddf Limitations and Conditions of Use.Refer to Created by Independent Third Party: Yes manufacturer's installation instructions_ as a supplemental guide for attachment. 11698.7 07-Englert"Series Roof Panel-0.032"Aluminum, 16"Width,Attached to Plywood Deck 1101"(R2) Limits of Use Installation Instructions Approved for use in HVHZ:No FL11698 R3 II 7 S1101 032Alum WoodDeck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E P.E. #31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-37.5 Evaluation Reports Other: Refer to Evaluation Report for FL11698 R3 AE 7 S1101 032Alum WoodDeck EVALREPORT.Ddf Limitations and Conditions of Use.Refer to Created by Independent Third Party:Yes manufacturer's installation instructions as a supplemental guide for attachment. 11698.8 08-Englert"C Panel"(112) Roof Panel-26 Gauge Steel,24"Width,Attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ:No FL11698 R3 II 8 CPanel 26ga WoodDeck EVALREPORT.pdf Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E P.E. #31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-62 Evaluation Reports Other: Refer to Evaluation Report for FL11698 R3 AE 8 CPanel 26aa WoodDeck EVALREPORT Ddf Limitations and Conditions of Use. Refer to Created by Independent Third Party:Yes manufacturer's installation instructions as a supplemental guide for attachment. 11698.9 09-Englert"C Panel"(112) Roof Panel-0.032"Aluminum,24"Width,Attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ:No FL11698 R3 II 9 CPanel 032A1um WoodDeck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-99 Evaluation Reports Other:Refer to Evaluation Report for FL11698 R3 AE 9 CPanel 032A1um WoodDeck EVALREPORT Ddf Limitations and Conditions of Use.Refer to Created by Independent Third Party:Yes manufacturer's installation instructions as a supplemental guide for attachment. 11698.10 10-Englert"Series Roof Panel-24 Gauge Steel, 15-1/4"Width,Attached to Plywood Deck 11500"(112) Limits of Use Installation Instructions Approved for use in HVHZ:No FL11698 R3 II 10 S1500 24oa WoodDeck EVALREPORT Ddf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E.P.E.#31242 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-150max. Evaluation Reports Other:Refer to Evaluation Report for FL11698 R3 AE 10 S1500 24ga WoodDeck EVALREPORT Ddf Limitations and Conditions of Use. Refer to Created by Independent Third Party: Yes manufacturer's installation instructions as a supplemental guide for attachment. Badc Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone,850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here Product Approval Accepts: M® eCh'uk M Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dti.aspx?paraTn=wGEVXQwtDgsQFc5K`/o2f Tr... 4/7/2017 Florida Building Code Online Page 3 of 3 Limits of Use Installation Instructions Approved for use in HVHZ:No FL11698 R3 II 6 S1101 24oa WoodDeck EVALREPORT Ddf Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-165 max. Evaluation Reports Other:Refer to Evaluation Report for FL11698 R3 AE 6 S1101 24oa WoodDeck EVALREPORT.Ddf Limitations and Conditions of Use.Refer to Created by Independent Third Party:Yes manufacturer's installation instructions as a supplemental guide for attachment. 11698.7 07-Englert"Series Roof Panel-0.032"Aluminum, 16"Width,Attached to Plywood Deck 1101"(R2) Limits of Use Installation Instructions Approved for use in HVHZ:No FL11698 R3 II 7 S1101 032Alum WoodDeck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E P.E. #31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-37.5 Evaluation Reports Other:Refer to Evaluation Report for FL11698 R3 AE 7 S1101 032A1um WoodDeck EVALREPORT.Ddf Limitations and Conditions of Use.Refer to Created by Independent Third Party:Yes manufacturer's installation instructions as a supplemental guide for attachment. 11698.8 i 08-Englert"C Panel"(112) Roof Panel-26 Gauge Steel,24"Width,Attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ:No FL11698 R3 II 8 CPanel 26oa WoodDeck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E P.E. #31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-62 Evaluation Reports Other: Refer to Evaluation Report for FL11698 R3 AE 8 CPanel 26oa WoodDeck EVALREPORT.pdf Limitations and Conditions of Use. Refer to Created by Independent Third Party:Yes manufacturer's installation instructions as a supplemental guide for attachment. 11698.9 1 09-Englert"C Panel"(112) Roof Panel-0.032"Aluminum,24"Width,Attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL11698 R3 II 9 CPanel 032A1um WoodDeck EVALREPORT.Ddf Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E P.E. #31242 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:+N/A/-99 Evaluation Reports Other:Refer to Evaluation Report for FL11698 R3 AE 9 CPanel 032A1um WoodDeck EVALREPORT Ddf Limitations and Conditions of Use. Refer to Created by Independent Third Party: Yes manufacturer's installation instructions as a supplemental guide for attachment. 11698.10 10-Englert"Series Roof Panel-24 Gauge Steel, 15-1/4"Width,Attached to Plywood Deck 11500"(R2) Limits of Use Installation Instructions Approved for use in HVHZ:No FL11698 R3 II 10 S1500 24oa WoodDeck EVALREPORT.Ddf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.P.E.#31242 Impact Resistant:N/A Created by Independent Third Party: Yes Design Pressure:+N/A/-150max Evaluation Reports Other: Refer to Evaluation Report for FL11698 R3 AE 10 S1500 24ga WoodDeck EVALREPORT Ddf Limitations and Conditions of Use.Refer to Created by Independent Third Party: Yes manufacturer's installation instructions as a supplemental guide for attachment. Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email addressif they have one .the licensee.However email addresses are public record.If you do not wish to .The emails provided may be used for official communication with supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here_. Product Approval Accepts: MM M a hsck M Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsQFc5KD/o2f l'r... 4/7/2017 NCSUCK E:ngineering SpL=a1cslttj Strlrlc-tur l &nq1nL=L=r1nq CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report " nglert® Series 11 Q„ Metal Roof Assembly Manufacturer: nglert, Inc. 1200 Amboy Avenue Perth Amboy, NJ 08862 for Florida Product Approval FL 11698.5 Florida Building Code Sth Edition (2014) Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: "Series 1100" Roof Panel Material: Aluminum Panel Thickness: 0.032" Panel Width: 16" Panel Seam: Snap-Lock Support: Wood Deck Digitally signed by James L.Buckner,P.E. Prepared b Electronically signed and sealed documents p Y shall comply with the provisions of FAC Rule James L. Buckner, P.E., SECB 61c15-23.`\\\\„i,,,,,�� Florida Professional Engineer#31242 .`���Es.L ...... Florida Evaluation ANE ID: 1916 P. \CENSF''•,F,p'; Project Manager: Diana Galloway - *' "°s1za2 Report No. 15-126-S1100-A3W-ER - * ' � : (Revises 15-126-S1100-A3W-ER) • STATE OF Date: 4/4/ 16 N '•.FLORIOP.•'' Contents: Evaluation Report Pages 1-8 w 2016.04.15 16:17:24-04'00' CBUCK,Inc.•Palm Beach County,Florida Phone:(561)491-9927 Email:chuck@cbuckinc.net•Website:www.cbuckinc.net Mailing Address:2637 E.Atlantic Blvd,#34069,Pompano,FL 33062 FL#: FL 11698.5 R3 Date: 4/4/16 Engineerinq Report No.:16-122-1100-A3W-ER Page 2 of 8 st cicsit � stri ctur i &n irk erir1 CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: Englert, Inc. 1200 Amboy Avenue Perth Amboy, NJ 08862 (732)826-8614 Product Name: - "Series 1100" Product Category: Roofing Product Sub-Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System "Series 1100"Standing Seam Roof Panel Description: 0.032" Aluminum Snap-Lock roof panel mechanically attached to Wood Deck with fixed panel clips&screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Panel Clip 3. Fasteners 4. Seam Adhesive 5. Underlayment 6. Insulation (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32"or 19/32"or greater plywood, (Per Table A) • or Wood plank(min.specific gravity of 0.42) Slope: Minimum slope shall be: 3 : 12 or greater In compliance with FBC Chapter 15 based on the type of roof covering, applicable code sections , and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure: Refer to Table A (Refer to "Table A" attachment details herein) FL#: FL 11698.5 R3 Date: 4/4/16 Report NO.: 16-122-1100-A3W-ER Page 3 of 8 S� c1 It�lj fl 1 OJfI f'6Q1!'1TIIIrI CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: • UL580-06—Test for Uplift Resistance of Roof Assemblies • TAS 125-03—Standard Requirements for Metal Roofing Systems Standards Equivalency: The UL 580-94 standard version used to test the evaluated product assembly is equivalent with the prescribed standards in UL 580-06 adopted by the Florida Building Code 5th Edition (2014). Code Compliance: The product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report This product evaluation is limited to compliance with the structural Scope: requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • This evaluation report for "Optional Statewide Approval' contains technical Conditions of Use: documentation, specifications and installation method(s) which include "Limitations and Conditions of Use"throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. • Option for application outside "Limitations and Conditions of Use" • Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • Deck shall be in compliance with applicable building code. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade& Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID#QUA 1824). FL#: FL 11698.5 R3 Date: 4/4/16 Report NO.: 16-122-1100-A3W-ER Page 4 of 8 Sp clalfiy Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Components/Materials Roof Panel: Englert Series 1100 (by Manufacturer): Material: Aluminum Thickness: 0.032" (min.) Panel Widths: 16" (max.) Coverage Rib Height: 1-1/4- Alloy Type: 3105-H14(in compliance with ASTM B 209) Corrosion Resistance: Per FBC Section 1507.4.3 Roof Panel Clips: Product Name: Englert"Series 1100 Clip" Englert Part#: 05079A Type: One-piece,fixed clip Material: Galvanized Steel Thickness: 24 Gauge min, Yield Strength: 40 ksi min. Dimensions: 1-3/16" (tall)x 1-15/16" (long)x 3" (wide) Corrosion Resistance: Per FBC Section 1506.7 Fastener: Type: Pancake-Head Wood Screw Size: #10 x 1" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.1 Components&Materials: Seam Adhesive/Sealant: (by Others) Product Name: Bostik 915 Type: One component, polyurethane adhesive Application Size: 1/8" bead Application Location: along female flange the full length of panel (Refer to drawing Page 7) Insulation (Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf(Ibs/ft3) min. Or Compressive Strength: 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL#: FL 11698.5 R3 Date: 4/4/16 Report No.: 16-122-1100-A3W-ER CBUCK L-nQinL=e%r1ncj Page 5 of 8 CBU S Specie thj Structural EngineeringCBUCK,Inc.Certificate of Authorization#8064 Installation: Installation Method: (Refer to"TABLE A" below and drawings at the end of this evaluation report.) ■ Clip Spacing: Refer to"TABLE A"Below (along the length of the panel) • Two(2)fasteners per Clip • Rib Interlock: Snap-Lock (Panel ribs shall be fully engaged to form an integral snap-lock.) ■ Minimum fastener penetration thru bottom of support, 3/16". ■ For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE"A"ALLOWABLE LOADS "Series 1100"(.032"Aluminum) Roof Panel attached to Wood Deck # Panel Deck Panel Clip #of Seam Panel Design Width Thickness Clip Spacing Fasteners Adhesive Seam Pressure (max.) (min.) (max.) per Clip (min.) (ASD) 1 16" 19/32" 3"Fixed 24" 2 NO SnapLock -37.5 PSF 2 16" 15/32" 3" Fixed 12" 2 YES SnapLock -105 PSF Note:Allowable design pressure(s)for allowable stress design(ASD). L Install the "Series 1100" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. Uplift Class 60 Based on UL580 Uplift Test By Hurricane Test Laboratories, Inc. (FBC Organization#TST ID: 1527) Report#0155-0713-04,Specimen#2(#1)Date:9/21/04 2. TAS 125 Uplift Test By Intertek/Architectural Testing,Inc.(FBC Organization ID#TST 1558) Report No. F5010.01-109-18-r0(#2) Date:3/08/16 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) Englert, Inc. Licensee#420 4. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 5. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) FL#: FL 11698.5 R3 Date: 4/4/16 Report No.: 16-122-1100-A3W-ER Page 6 of 8 Spec i �lj Stru urai E=n t �rtnq CBUCK,Inc.Certificate of Authorization#8064 - Installation Method Englert, Inc. "Series 1100" (0.032" Aluminum) Roof Panel attached to Wood Deck Drawings 16" Max. Coverage T r Panel Profile 0 1-3/16" � 3 Panel Clip Profile Englert "Series 1100 Clip" (Part#05079A) FL#: FL 11698.5 R3 Date: 4/4/16 CBUCK Engineering Report No.:16-122-1100-A3W-ER Page 7 of 8 Sp CiG'wtj srrur—tural E=nQInL=L=rinc;) CBUCK,Inc.Certificate of Authorization#8064 Installation Method Englert, Inc. "Series 1100" (0.032" Aluminum) Roof Panel attached to Wood Deck 1/8" Bead Bostik 915Adhesive continuous along panel seam 16" Integral Snap Lock O O O O O O O SONNE"x O O O O #10 Pancake Head Screws Wood Deck (Two per Clip) Typical Assembly Profile View (Typical Fastening Pattern Across Width) FL#: FL 11698.5 R3 Date: 4/4/16 Report No.: 16-122-1100-A3W-ER Page 8 of 8 s ecicaI1'y strl.! urcm r=ngltl'°°i erinc) CSUCK,Inc.Certificate of Authorization#8064 Installation Method Englert, Inc. "Series 1100" (0.032" Aluminum) Roof Panel attached to Wood Deck Fasteners: #10 Pancake-Head Mod Screws, "Series 1109'Roof Panel (Two per Clip) Series 1100 Panel Clip Wood Deck Typical Roof Assembly Isometric View (Optional) Rigid Insulation Board per Page 4 of this report TABLE"A"ALLOWABLE LOADS "Series 1100"(.032"Aluminum) Roof Panel attached to Wood Deck # Panel Deck Panel Clip #of Seam Panel Design Width Thickness Clip Spacing Fasteners Adhesive Seam Pressure (max.) (min.) (max.) per Clip (min.) (ASD) 1 16" 19/32" 3" Fixed 24" 2 NO SnapLock -37.5 PSF 2 16" 15/32" 3"Fixed 12" 2 YES SnapLock -105 PSF Note:Allowable design pressure(s)for allowable stress design(ASD).