Loading...
HomeMy WebLinkAboutNotice of Acceptance MIAMI MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: VersaShield® Fire-Resistant Roof Deck Protection and VersaShield° SoloTM Fire-Resistant Slip Sheet LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 14-1022.26 and consists of pages 1 through 3. The submitted documentation was reviewed by Alex Tigera. O 6-�2p�16.02 MIAMI•DADE COUNTY - . Y!07/22 FI x i a o Y! r ai 0 /02/17 Page 1 of 3 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Underlayment Material: Fiberglass SCOPE: This acceptance is for VersaShield® Fire-Resistant Roof Deck Protection (a.k.a "VersaShield® Underlayment") and VersaShield®SoIoTM Fire-Resistant Slip Sheet(a.k.a"VersaShield SoIoTM"), as described in this Notice of Acceptance, for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Specifications Description VersaShield®Fire- 42"x 100' rolls ASTM D 226 Non-Asphaltic fiberglass-based underlayment Resistant Roof Deck Type II and/or fire barrier. Protection VersaShield®SoIoTM 72"x 166.7' rolls UL790 Non-Asphaltic fiberglass-based slip sheet and/or Fire-Resistant Slip Sheet 36,x 166.7' rolls fire barrier. MANUFACTURING LOCATION: 1. Conover,NC EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GAF-270-02-02 ASTM D 226 11/15/10 Technologies GAF-748-02-01 ASTM D 226 12/12/16 ELK-063-02-01 TAS 100 09/27/01. Underwriters Laboratories Inc. 99NK45831 UL790 03/21/00 1 ONK11990 UL790 05/18/11 R19254 ASTM D 226 09/13/01 08CA37926 UL790 09/23/09 08CA49140 INSTALLATION: 1. VersaShield®Fire-Resistant Roof Deck Protection or VersaShield®SoIoTM Fire-Resistant Slip Sheet shall be installed in strict compliance with applicable Building Code. 2. VersaShield®Fire-Resistant Roof Deck Protection or VersaShield®Solo TM Fire-Resistant Slip Sheet shall be installed with a minimum 4-inch head lap in a shingle layer fashion. 3. VersaShield®Fire-Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type II underlayment. MIAMI•DADE COUNTY NOA No.: 16-1216.02 Expiration Date: 02/07/22 Approval Date: 02/02/17 Page 2 of 3 s LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. VersaShield®Fire-Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application.VersaShield®SoIoTM Fire-Resistant Slip Sheet shall not be left exposed to the weather. 4. VersaShield® Fire-Resistant Roof Deck Protection and VersaShield® SoIoTM Fire-Resistant Slip Sheet are a component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. VersaShield® Fire-Resistant Roof Deck Protection or VersaShield®SoIoTM Fire-Resistant Slip Sheet may be used with any approved roof covering Notice of Acceptance listing. VersaShield®Fire-Resistant Roof Deck Protection or VersaShield® SoIoTM Fire-Resistant Slip Sheet may be used as a component part of an assembly in the Notice of Acceptance. If VersaShield®Fire-Resistant Roof Deck Protection or VersaShield®SoIoTM Fire-Resistant Slip Sheet is not listed, a request may be made to the Authority Having Jurisdiction(AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance, and fire testing results. 6. VersaShield® Fire-Resistant Roof Deck Protection and VersaShield® SoIoTM Fire-Resistant Slip Sheet are a non- asphaltic underlayment that may be used as a fire barrier for prepared roof assemblies. For fire classification of specific roof assemblies using VersaShield® Fire-Resistant Roof Deck Protection or VersaShield® SoIoTM Fire- Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility,yellow line to identify the ASTM Standard designation or logo, and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this material. END OF THIS ACCEPTANCE MIAMI•DADE C NOA No.: 16-1216.02 OUNTY Expiration Date: 02/07/22 Approval Date: 02/02/17 Page 3 of 3 FA ES; . - .� I S/H1A Seismic and Hurricane Ties t t S/1­11A is designed to fit within several proprietary I truss chords to provide uplift resistance. Material:43 mil(18 ga) Finish:Galvanized Installation:•Use all specified fasteners. Typical S/1­11A • S/H1A can be installed with flanges facing i Installation outwards,reverse of illustration,when installed inside a wall for truss applications. • S/H1A does not replace solid blocking. • S/H1A may be used with proprietary truss I S/H1A ° t sections.Contact material supplier for specific " I installation details. ' Z'/a<" Codes:See page 11 for Code Report Reference I \ Y Key Chart. Fastenersa Allowable Uplift Loads`(Ibs) Typical S/H1 A Truss Installation Models z � Code To Thickness Plate(Wall Stud Thickness fttil(ga) q + N° Truss p Stud rod(ga) ,; Ref; Track 33 mil(20�9a)43 mll.(18 ga)34 and(16 ga) s 4-#10 3-#10 1-#10 27(22ga) 470 470 470 S/H1A 3131, 3(20 ga) 510', 550:,, 690 ,;,: IF4, �_.F ..., .. _ ... 4-#10 3-#10 1-#10 43(18 ga) 510 550 690 L2 4 tk10 3=(110 1-7,#10 54 1G a %520' 675 850 � ( g ) 1.Tabulated loads based on truss members with yield strength,Fy,of 50 ksi and tensile strength, Fc,of 65 ksi.Reduce tabulated load proportionally for lower truss member steel strength. Typical S/H7 A For example:43 mil(18 ga)truss member with a yield strength,Fy of 33 ksi and a tensile strength, Installation Fe,of 45 ksi is connected to 43 mil top track and wall stud.The adjusted allowable load is then x 550 lbs.x minimum[33/50 or 45/60]=363 lbs. 2.See pages 65 through 81 for more information on Simpson Strong-Tie fasteners. 4.0 cc MTSM/HTSM Twist Straps o The MTSM and HTSM offer high-strength truss-to- z W } masonry connections. 3 MTSM 16 Material:See table. ° Finish:Galvanized.Some products available in , w MTSM20 w stainless steel and ZMAX°;see Corrosion Information, y � t�° Moisture a v pages 17-20. i barrier L ° o not shown I Installation: #5 Rebar 7 z • Use all specified fasteners.See General Notes. ,t .. '• May be attached to either side of a grouted s ". T .a ° block wall.A minimum of one#5 horizontal rebar '/z"Min. c ° o shall be installed in the top course of this wall. '` o �" Titen®screws o Codes:See page 11 for Code Report Reference Key Chart. Typical MTSM20 Installation Connector Fastenerss A_tlowable -� Motlel Mafenal L; Loads Code o Rafter/Stud/Joist Thickness. f No Thickness (m.) - CMUS Concrete'S 33 mil(20 ga) Ref ; z milga)a 33 rnR(20 ga.)43,mi1(18'ga.}54 mil(16 ga) (lb's) MTSM16 54 16 5410 4410 3410 4 '/4x2'/4T1ten 4 Ynx11/4T1ten 860 0 MTSM20 (16 ga) #10 1 3 Ak10 4 '/ax2'14Titen 4 '144il'%Titen 860 170 HTSM16 HTSM16 B8 16 7-#10 5-#10 3-#10 4-'I4x2'/4Titen 4-%x1'/4Titen 1175 • ;HTSM20` (t4ga) 20`, ` 7=#10 ", I #10 3-#10; 4E'I4zZCTlten 4,'/„4z1'l4Titen. 1175 a �y 1.All straps have additional fastener holes. 2.Twist straps do not have to be wrapped over the truss to achieve the load. — 20 3.Minimum edge distance in concrete block for Titen screws is 11/2".4.They can be installed on the inside face of the wall. F ;, 5.Min.f m=1500 psi and Fc=2500 psi. LE CO Vsm 6.See pages 65 through 81 for more information on Simpson Strong-Tie fasteners. 131 r NUTRUSS BOTTOM CHORD CUP: NTC-6 W/(5) #100" HEX SCREWS TO TRUSS AND (5) 1Ox3/4" HEX SCREWS TO T% PLAKI. LOAD BEARING COLD FORMED STEEL TOP PLATE OR HEADER INTERIOR LOAD BEARING COLD FORMED STEEL STUD WALL :TRUSS TO COLD FORMED STEEL WALL CONNECTION N.T,S, 02-01-13 CONNECTION ALLOWABLE UPLIFT CAPACITY (POUNDS) FOR NTC-6 CLIP 5DMIKSI 33 KSI 50 KSI 33 KSI 50 KSI 27 204 295 408 590 NTC-6 33 250 361 500 722 �t�pg91lOtIP90 �a 43 323 466 645 932ry�t� 54 476 688 953 1376 0®o�o+ �1, NOTE: CONNECTION ALLOWABLE UPLIFT CAPACITY (POUNDS) USING ( 5 ) #1Ox3/4" SCREWS IN PULLOUT BASED ON WALL TOP PLATE THICKNESS AND MATERIAL No '3 e YIELD. NOTE: TOP PLATE MUST BE EQUAL TO •� OR GREATER THAN BOTTOM STA a o CHORD THICKNESS. REVISIONS014A REVISED BY DESCRIPTION OF CHANCE DATE 10/12/2016 DETAIL # FD-6-4 FABRICATOR DRAWN BY: JAS CHK'D BY:RLF DETAIL NAME: DATE: 02-01-13 DATE: 02-01-13 FRUSS TO COLD FORMED STEEL WALL CONNECTION y r> 41 UK AIV. TM VERSA Fa S y-ENIN G SYSTEM 2 5 tl,ti5, t . Specifications Material 1060 Carbon Steel Finish .0002 zinc Head Diameter .250 Shank Diameter .100 Length 1-1/2" Knurl Gripshanke SuperSharp Point Style Ballistic Collation Plastic Sheet Collated Quantity per Carton 3.2M Aerosmith Quality Control Process Aerosmith internally verifies each lot of pins to meet the following requirements: - Lot Trace - Pin Dimensions y� - Bend Test - Collation Specifications - Test fire each lot RECEIVED APR 05 2017 Gold Bond° BRAND Gypsum Board 09 29 00/NGC ram- DESCRIPTIO ® e , �• I ii , ii e Gypsum Board is the name for Fire and sound ratings for Examine and inspect materials with edges of opening unless a family of board products building systems utilizing to which ypsum board is to control Joints will be consisting of a gypsum board are dependent be applie .Remedy all installed at these points.End noncombustible core, on the core type and defects prior to installation of joints shall be staggered,and primarily of gypsum,with a thickness of the gypsum drywall.Any defects in the joints on opposite sides of a Epaper surfacing on the face, board,its application in finished installation due to partition shall not occur on ack and long edges.* conjunction with the misaligned framing or other the same stud. component parts,and the cause will be the Gypsum board shall be held in The popularity of gypsum board manner in which it is Yf? results from a number of responsibility of the work firm contact with the framing applied. performed under that section member while fasteners are factors.First,it takes virtually any decoration—from paint Tests for fire resistance and of the specification and such being driven.Fastening shall or textures to vinyl and sound transmission, defects shall be remedied proceed from center portion paper laminates.It also lends F)erformed by independent under that section of the of the board toward the itself to creative shaping of laboratories,have resulted in specification. edges and ends.Fasteners interior surfaces,allowing specific ratings for walls/ Gypsum board shall be applied shall be set with the heads the maximum in design partitions;floor/ceiling first to ceiling at right angles slightly below the surface of flexibility.Gypsum board is assemblies;shaftwalis, to framing members,then to the board in a dimple an economical alternative to stairwells and area walls.Boards of maximum formed by the hammer or other products.Because it is separation walls;and practical length shall be used power screwdriver.Care lightwei lit,it is easy to columns.For maximum fire so that an absolute mininTI-Ii shall be taken to avoid handle for speedy resistance and sound control, number of end joints occur. breaking the face paper of installation.With its natural double layer construction is Board edges shall be brought the gypsum board. properties,it is durable yet generally recommended into contact with each-other Improperly driven nails or easy to repair.In addition, since the additional mass but shall not be forced into screws shall be removed. gypsum board's fire further retards heat and noise place. Seepage 63,Environmental resistance and sound control penetration. Gypsum board joints at Conditions and Limitations. capabilities further Gypsum board can be installed openings shall be located so demonstrate its desirability to both metal and wood that no end joint will align in building systems. framing using nails,screws Ever conscious of the or adhesives in combination environmental challenges with nails or screws.In many we face in today's world, instances,the application CURVED SURFACES National Gypsum produces will dictate which fastening To apply gypsum board over a curved surface,place a stop at one end its gypsum board with 100 method is appropriate. of the board and then gently and gradually push on the other end, _ percent recycled paper on Control joints may be necessary forcing the center against the framing until the curve is complete. _ both the face and back. to prevent cracking in the Shorter radii than shown in the table may be obtained by moisten- Gold Bond gypsum board is gypsum board facing of ing the face and back papers of the board with water,stacking on a available with a variety of drywall systems,especially flat surface,and allowing the water to soak into the core for at least edge configurations.For easy in areas where structural one hour.When the board is dry it will regain its original hardness. joint finishing,the tapered elements such as slabs, Gypsum board may be applied to curved surfaces in accordance with edge is preferred to provide columns or exterior walls the following: a monolithic surface.Where can bear directly on non- joints will be exposed, load-bearing partitions.To GYPSUM BOARD BENDING RADII s uare or beveled ed es relieve the stresses which q occur as a result of Thickness Bending Lengthwise Bending Widthwise should beconsidered. Gypsum s m also movement induced b National Gypsgu�p also Y 1/4"(6.4 min) 5'-0°(1524 min) 15'-0"(4572 min) manufactures sum board changes in moisture, 3/8" 9.4 mm) 7'-6" 2286 min) 25'-0" 7620 mm) with proprietary edge temperature or both,control 1/2" 12.7 min "10'-0"(3048 mm) configurations made to joints are required in both 5/8'(15.9 mm) 15'-0"(4572 mm) accommodate a variety of partitions and ceilings. wall systems and finishing GYPSUM BOARD *Bending two layers of 1/4"(6.4 mm)board successively will permit a bending techniques. INSULATING PROPERTIES radius shown for 1/4"(6.4 mm)board'. *GA-216 For purposes of calculating Note:To achieve tighter bending radii,use Gold Bond 1/4"High Fire and sound ratings for "U"values,the"C"factor for Flex Gypsum Board.See page 75 for additional information and building systems utilizing 1"gypsum board is 1.2; 1/4"High Flex minimum bending radii chart. gypsum board are Resistance"R"for 3/8"board dependent on the core type is.32;for 1/2"board.45;for SURFACE BURNING CHARACTERISTICS and thickness of the gypsum 5/8"board.56 and for 1" (Fire Hazard Classification)Tested in accordance with ASTM E 84 board.83. Gypsum Gypsum Durasan WEIGHTS Board Sheathing All Standard Patterns 1/4"Regular-1.2 Ibs/SF Flame Spread Index 15 20 25 or less 3/8"Regular-1.2 Ibs/SF Smoke Developed 0 0 50 or less to- 1/2"Regular-1.6 Ibs/SF i P THE FOLLOWING PARAGRAPHS ARE FOR INSERTION INTO SECTIONS OF GENERIC SPECIFICATIONS OR GFNERIC/PROPRIETARY SPECIFICATIONS COVERING GYPSUM BOARD PRODUCTS.THE NATIONAL GYPSUM PRODUCT NAME FOLLOWS THE GENERIC DESCRIPTION IN PARENTHESES. PART 2 PRODUCTS 2.01 MATERIALS A.Regular Gypsum Board:A gypsum core board that is fire resistant and surfaced with paper on front/back and long edges and complies with ASTM C 1396. 1.Thickness:1/4",3/8",1/2"(Gold Bond BRAND Gypsum Board) 3.Length:6'through 16'. � �� 2.Width:4'. 4.Edges:Square,Tapered,or Beveled Ta� St" Smo PART 3 EXECUTION 3.01 INSTALLATION A.General:In accordance with the manufacturer's recommendations,National Gypsum Company'`Gypsum Construction Guide." NATIONAL GYPSUM BOARD PRODUCTS 65 High Impact Fiberglass Mesh Specification sheet IN . . . ASTM D-76;ASTM D-579 D-5035;ASTM MIL-Y-1140 TYPE- 4515 High IMPACT(SD.4515M2/40) COUNT: Warp-ends/in 6 Fill-picks /in 4 WEAVE- Leno 6 X 4 STANDARD 38 inches M STANDARD 150 Feet AREA • 238 sq. ft. MESH • Dry Weight 468 g/sq.m (13.8 oz./sq.yd.) Coating Weight 60 g/sq.m ( 1.7 oz./sq.yd.) 12% Finished Weight (+/- 10%) 528 g/sq.m (15.5 oz./sq.yd.) GLASS • • • Warp ECK 18- 1/0 Fill 250 yds/lb Roving AVERAGE BREAKING dN/5 cm (lbf/2 in.) Warp 270- ( 618) (8 picks&12 ends tested) Fill 968 (2210) Alkali Resistance after conditioning Warp 269 ( 614) 99% according to EIMA Standard 105.01 Fill 965 (2204) 99% ELONGATION- Warp 3.4% Fill 3.9% Soft,alkali resistant,self-extinguishing. Compatible with other materials of EIFS Our technical advice on the uses of our materials is given without obligation or warranty. ------------------------------------------------------------------------------------------------------------------------------------------ Riverview Manufacturing 866.975.9510 Toll Free 5841 Jacaranda Drive SE 404.691.4000 Local Mableton,GA 30126 800.794.0727 Fax www.TIQUEwall.com FILE COPY