HomeMy WebLinkAboutProduct Approval (8) VS Intertek Architectural Testing MIAMI-DADE COUNTY PERFORMANCE TEST REPORT Report No.: C4826.01-450-18 Rendered to: NEXGEN FRAMING SYSTEM, LLC Melbourne, Florida PRODUCT TYPE: 8'x 10' Composite Wall Panel MODEL: Insulated CFS with Synthetic Stucco Finish Wall Panel This report contains in its entirety: Cover Page: 1 page Report Body: 12 pages o``oSEp�.A.RFF'% Sketches: 3 pages Photographs: 2 pages _ * No.58920 Drawings: 4 pages 0'. STATE OF (V41` OR1�3' lqz�'\� l0ll�j1p�lL`E\`����` OigieN sgm bj:.los¢ph a Ra.tl 2016.04.18 16:28:05 -04'00' Test Start Date: 9/16/2013 Test End Date: 11/8/2013 Report Date: 4/18/2016 Test Record Retention End Date: 11/8/2023 Miami-Dade County Notification No.: ATIWPB 12032 FIL - a 2658 Electronics Way www.archtest.com . www.intertek.com/building P• 561.881.0020 West Palm Beach, FL 33407 f. 717.764.4129 Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing Page 1 of 12 1.0 Client Identification: y 1.1 Report Issued To: NexGen Framing System, LLC 445 Stan Drive, Suite 1 Melbourne,Florida 32904 1.2 Contact Person: Z. Cliff Singleton 2.0 Laboratory Identification: 2.1 Test Laboratory: Architectural Testing,Inc., an Intertek company("Intertek-ATI") 2658 Electronics Way West Palm Beach,Florida 33407 2.2 Laboratory Phone Number: 561-881-0020 3.0 Project Summary: 3.1 Introduction: Architectural Testing, Inc., an Intertek company ("Intertek-ATI") was contracted by NexGen Framing System, LLC to conduct TAS 201,TAS 202,and TAS 203 testing on their composite wall panel in accordance with Florida Building Code for High Velocity Hurricane Zone and Miami-Dade County requirements. The three specimens tested met the performance requirements set forth in the protocols. The results are summarized in Table 1. Table 1: Summary of Test Results Specimen# Test Protocol Design Pressure 1 TAS 201 (Large Missile TAS 203 +45 -45 psf 2 TAS 201 (Large Missile TAS 203 +45 -45 psf 3 TAS 202 TAS 201 (Large Missile TAS 203 +45 -45 psf 3.2 Product Type: 8'x 10' Composite Wall Panel 3.3 Series/Model: Insulated CFS with Synthetic Stucco Finish Wall Panel 3.4 Miami-Dade County Notification No.: ATIWPB 12032 3.5 Test Dates: 9/16/2013 - 11/8/2013 3.6 Test Record Retention End Date: 11/8/2023 3.7 Test Location: Intertek-ATI test facility in West Palm Beach, Florida. www.archtest.com . www.intertek.com/building Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing Page 2 of 12 3.0 Project Summary: (Continued) 3.8 Test Specimen Source: The test specimen(s) was provided by the client. Representative samples of the test specimen(s) will be retained by Intertek-ATI for a minimum of ten years from the report completion date. 3.9 Drawing Reference: The test specimen drawings have been reviewed by Intertek-ATI and are representative of the test specimen(s) reported herein. Test specimen construction was verified by Intertek-ATI per the drawings located in Appendix C. Any deviations are documented herein and on the drawings. 3.10 List of Official Observers: Name Company Z. Cliff Singleton NexGen Framing System, LLC Jeff McGovern Intertek-ATI Kristin Nolan Intertek-ATI Veron Wickham Intertek-ATI Joseph A. Reed, P.E. Intertek-ATI Alan Rule Intertek-ATI 4.0 Test Protocol(s): TAS 201-94,Impact Test Procedures TAS 202-94, Criteria for Testing Impact & Non Impact Resistant Building Envelope Components Using Uniform Static Air Pressure TAS 203-94,Criteria for Testing Products Subject to Cyclic Wind Pressure Loading 5.0 Test Specimen Description: 5.1 Product Sizes: Table 2 provides product sizes for the overall test specimens. Table 2: Overall Specimen Size Overall Area: Width (in.) Height(in.) 80.0 ftz Overall size 96 120 www.archtest.com . www.intertek.com/building Ak Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 . Architectural Testing Page 3 of 12 5.0 Test Specimen Description: (Continued) 5.2 Frame Construction: The frames for all three specimens were fabricated utilizing the members listed in Table 3. The specimen consisted of 3.5" CFS 20GA stud wall assembly. Studs were 24" on center with double studs every 48" on center. Studs were connected using 3/16" diameter rivets at all CFS member intersections. Double studs were attached by using two #10 x 1" self-tapping screws located 24" on center. Horizontal supports were staggered 4' 0-1/4" from the bottom of specimen and 1' 11-3/4" from the top of specimen. Specimen was sheathed with 1/2" gypsum board attached with #8 x 1-1/4"self-tapping drywall screws. Table 3: Wall Panel Details Frame Member Material Description 1/2" Gypsum Board. #8 x 1-1/4" Drywall Gypsum board self-tapping screws at 7" on center perimeter, 8" on center in field. 3.5" CFS min 20GA stud at 24" on Studs 20 ga. stud center. 3/16" diameter rivets at CFS member connection. Insulation Spray foam Min. 2.75" open cell spray foam 0.5 LBS density. (Sprayed on site. Min 1.25" polyurethane spray foam Insulation Spray foam 2.0 lb density with embedded 10 oz./yd. open weave glass fiber reinforcin mesh. EPS sheet EPS sheet 1" EPS sheet. 3.0 lb density. BASF Senergy Alpha Basecoat with Base coat Synthetic stucco embedded 20 oz./yd. open weave lass fiber reinforcing mesh. BASF Senergy Alpha Basecoat with Base coat Synthetic stucco embedded 20 oz./yd. open weave lass fiber reinforcing mesh. Waterproofing 100%acrylic BASF Senershield-R rimer Finish stucco 100%acrylic BASF Synergy Finish Coat. Textured Classic and colored www.archtest.com . www.intertek.com/building Ak Test Report No.:.C4826.01-450-18 Report Date: 4/18/2016 Architectural resting Page 4 Of 12 5.0 Test Specimen Description: (Continued) 5.2 Frame Construction: (Continued) 5.2.1 Frame Corner Construction: The frame corners were constructed as described in Table 4. Table 4: Frame Corner Construction Details Location joinery Type Details All corners 3/16" diameter rivets At CFS member connection. Horizontal supports 3/16" diameter rivets At CFS member connection. Double studs Two #10 x 1" self-tapping 24" on center along double studs screws 5.3 Installation: Table 5 provides details of the test specimen installation into the Pine test buck. The exterior perimeter of the test specimen was sealed with sealant. Table 5: Installation Details Location Anchor Description Anchor Location Head and sill 1/4 x 2-3/4"self-drilling screw 24" on center www.archtest.com . www.intertek.com/building Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing Page 5 of 12 6.0 Test Results: The temperature during TAS 202 testing was between 76°-80°F. Results are tabulated as follows: 6.1 Protocol TAS 202-94,Static Air Pressure Table 6 provides the results for the air infiltration test. Table 6: Test Specimen#3 TAS 202,Air Infiltration Test Results Test Pressure Results Air Infiltration at 1.57 psf 25 mph) 0.00 Cfm ft2 Air Infiltration at 6.24 psf 50 mph) 0.00 Cfm ft2 Table 7 provides the results for positive and negative uniform static load test. Table 7: Test Specimen#3 TAS 202,Preload and Design Load Test Results Load Indicator Deflection(in.) Permanent Set in.) (psf) Location Measured Allowed Measured Allowed +33.75 50% of Test B 0.316 0.667 0.010 0.240 Pressure +45.00 Design B 0.436 0.667 0.017 0.240 Pressure -33.75 50%of Test B 0.326 0.667 0.020 0.240 Pressure -45.00 Design B 0.463 0.667 0.030 0.240 Pressure www.archtest.com . www.intertek.com/building Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing Page 6 of 12 6.0 Test Results: (Continued) 6.1 Protocol TAS 202-94,Static Air Pressure(Continued) Table 8 provides the results for the water penetration test. Table 8: Test Specimen#3 TAS 202,Water Penetration Test Results Title of Test Pressure Results Water Penetration 6.8 sf Pass 15% of Positive Design Pressure p Table 9 provides the results for the structural overload test. Table 9: Test Specimen#3 TAS 202,Structural Overload Test Results Load Indicator Deflection in. Permanent Set in. (psf) Location Measured Allowed Measured Allowed +67.50 B 0.924 N/A 0.031 0.240 Test Pressure D 1.136 N/A 0.129 N/A -67.50 B 1.063 N/A 0.112 0.240 Test Pressure D 1.301 N/A 0.147 N/A Note: See Intertek ATI Sketch #3 for indicator locations. Deflection/permanent set reported is the overall deflection between three points (longest unsupported span) which accounts for support movement. Indicator D was reported without support movement. Conclusion: Intertek-ATI observed no signs of failure in any area of the test specimen during the TAS 202 testing; as such, the test specimen satisfies the requirements of TAS 202. www.archtest.com . www.intertek.com/building Ak Test Report No.: C4826.01-450-18 IL Report Date: 4/18/2016 Architectural Testing Page 7 of 12 6.0 Test Results: The temperature during TAS 201 testing was between 75°-80°F. Results are tabulated as follows: 6.2 Protocol TAS 201-94,Large Impact Procedures Tables 10, 11,and 12 provide the results for the large missile.impact test. Table 10: Test Specimen#1 TAS 201, Large Missile Impact Test Results Impact Missile Missile Missile # Weight Length Velocity lbs. in. (ft./sec.) 1 9.3 94 50.58 2 9.3 94 49.14 3 9.3 94 49.09 Table 11: Test Specimen#2 TAS 201, Large Missile Impact Test Results Impact ' Missile Missile Missile # Weight Length Velocity lbs. in. (ft./sec.) 1 9.4 92 49.26 2 9.4 92 49.68 3 9.4 92 49.85 Table 12: Test Specimen#3 TAS 201, Large Missile Impact Test Results Impact Missile Missile Missile # Weight Length Velocity lbs. (in.) ((ft./sec.) 1 9.4 92 50.38 2 9.4 92 49.98 3 9.4 92 49.55 Note: See Intertek-ATI Sketches#1 and#2 for impact locations Conclusion: The large missiles impacted each intended target and Intertek-ATI carefully inspected each impact location. Intertek-ATI observed no signs of penetration, rupture, or opening after the large missile impact test; as such, each test specimen satisfies the large missile requirements of TAS 201. www.archtest.com . www.intertek.com/building Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing Page 8 of 12 6.0 Test Results: The temperature during TAS 203 testing was 79°-88°F. Results are tabulated as follows: 6.3 Protocol TAS 203-94, Cyclic Wind Pressure Loading Tables 13 through 21 provide the results for the positive and negative cyclic load test. Table 13: Test Specimen#1 TAS 203, Cyclic Test Spectrum and Average Cycle Time Design +45.0/-45.0 psf Stage Pressure 1 2 3 4 Pressure Range (psf) 9.0—22.5 0—27.0 22.5—36.0 13.5—45.0 Average Cycle Time(sec.) 3.25 6.22 3.41 6.92 Number of Cycles 3500 300 600 100 5 6 7 8 Pressure Range (psf) 13.5 —45.0 22.5 —36.0 0—27.0 9.0 —22.5 Average Cycle Time(sec.) 7.90 4.33 3.79 3.27 Number of Cycles 50 1050 50 3350 Table 14: Test Sped en#1 TAS 203, Positive Cyclic Load Test Results Indicator Maximum Permanent Location Deflection Set in. in. B 0.816 0.042 D 0.988 0.085 Table 15: Test S ecimen #1 TAS 203,Ne ative Cyclic Load test results Indicator Maximum Permanent Location Deflection Set in. in. B 0.725 0.037 D 0.848 0.068 Note: See Intertek-ATI Sketch 93 for indicator locations. Deflection/permanent set reported is the overall deflection between three points(longest unsupported span) which accounts for support movement. Indicator D was reported without support movement www.archtest.com . www.intertek.com/building Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing Page 9 of 12 6.0 Test Results: (Continued) 6.3 Protocol TAS 203-94, Cyclic Wind Pressure Loading (Continued) Table 16: Test Specimen#2 TAS 203, Cyclic Test Spectrum and Average Cycle Time Design +45.0/-45.0 psf Stage Pressure 1 2 3 4 Pressure Range (psf) 9.0 —22.5 0—27.0 22.5—36.0 13.5—45.0 Average Cycle Time (sec.) 3.44 6.28 3.32 6.88 Number of Cycles 3500 300 600 100 5 6 7 8 Pressure Range (psf) 13.5—45.0 22.5—36.0 0—27.0 9.0—22.5 Average Cycle Time (sec.) 8.00 4.00 3.80 3.00 Number of Cycles 50 1050 50 3350 Table 17: Test Sped en#2 TAS 203, Positive Cyclic Load Test Results Indicator Maximum Permanent Location Deflection Set in. in. B 0.641 0.051 D 0.894 0.147 Table 18: Test S ecimen#2 TAS 203, Negative Cyclic Load Test Results Indicator Maximum Permanent Location Deflection Set in. in. B 0.641 0.072 D 0.852 0.184 Note: See Intertek-ATI Sketch #3 for indicator locations. Deflection/permanent set reported is the overall deflection between three points(longest unsupported span) which accounts for support movement. Indicator D was reported without support movement www.archtest.com . www.intertek.com/building ' �Ak Test Report No.: C4826.01-450-18 �- Report Date: 4/18/2016 Architectural Testing Page 10 of 12 6.0 Test Results: (Continued) 6.3 Protocol TAS 203-94, Cyclic Wind Pressure Loading (Continued) Table 19: Test Specimen#3 TAS 203,Cyclic Test Spectrum and Average Cycle Time Design +45.0/-45.0 psf Sta e Pressure 1 2 3 4 Pressure Range (psf) 9.0—22.5 0—27.0 22.5—36.0 13.5—45.0 Average Cycle Time(sec.) 2.60 2.90 3.60 7.00 Number of Cycles 3500 300 600 100 5 6 7 8 Pressure Range (psf) 13.5—45.0 22.5—36.0 0—27.0 9.0 —22.5 Average Cycle Time(sec.) 7.60 4.20 3.80 3.10 Number of Cycles 50 1050 50 3350 Table 20: Test S ecimen#3 TAS 203, Positive Cyclic Load Test Results Indicator Maximum Permanent Location Deflection Set in. in. B 0.587 0.002 D 0.750 0.069 Table 21: Test S ecimen#3 TAS 203,Negative Cyclic Load Test Results Indicator Maximum Permanent Location Deflection Set in. in. B 0.689 0.049 D 0.821 0.128 Note: See Intertek-ATI Sketch #3 for indicator locations. Deflection/permanent set reported is the overall deflection between three points(longest unsupported span) which accounts for support movement. Indicator D was reported without support movement Conclusion: Intertek-ATI observed no signs of failure in any area of the test specimens during the cyclic load test; as such, the test specimens satisfy the cyclic load requirements of TAS 203. www.archtest.com . www.intertek.com/building Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing Page 11 of 12 7.0 Test Equipment: Cannon: Constructed from steel piping utilizing compressed air to propel the missile Missile: 2x4 Southern Pine Timing Device:-Electronic beam type Cycling Mechanism: Computer controlled centrifugal blower with electronic pressure measuring device Deflection Measuring Device: Linear transducers, 1" dial indicators, 2" dial indicators 8.0 Laboratory Compliance Statements: The following are provided as required by the protocols for the testing reported herein. Upon completion of testing,specimens tested for TAS 201-94 met the requirements of Section 1626 of the Florida Building Code, Building. Upon completion of testing,specimens tested for TAS 202-94 met the requirements of Section 1620 of the Florida Building Code, Building. Upon completion of testing,specimens tested for TAS 203-94 met the requirements of Section 1625 of the Florida Building Code, Building. Tape and film were used to seal against air leakage during structural testing. In our opinion,the tape and film did not influence the results of the test. www,archtest.com . www.intertek.com/building Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing Page 12 of 12 Intertek-ATI will service this report for the entire test record retention period. Test records that are retained such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation will be retained by Intertek-ATI for the entire test record retention period. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Intertek-ATI. For ARCHITECTURAL TESTING, Inc. Nil*Signed bY' hA.Rent Alan Rule Joseph A. Reed,P.E. Technician Team Leader Director- Engineering AWR:cmd Attachments(pages): This report is complete only when all attachments listed are included. Appendix A: Sketches(3) Appendix B: Photographs(2) Appendix C: Drawings(4) This report produced.from controlled document ternplaty AT[00651.,issued 01/1.8/1.3. www.archtest.com . www.intertek.com/building �- Test Report No.: C4826.01-450-18 Architectural Testing Report Date: 4/18/2016 �1• �,,_._�'`'� mow. :.�� `� ,44 Sketch#1 Impact Locations- Specimen#1 www.archtest.com . www.intertek.com/building k Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing Sketch#2 Impact Locations -Specimens#2 and#3 www.archtest.com www.intertek.com/building I �Ak Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing r-- A , L-J --N Sketch#3 Indicator Locations www.archtest.com . www.intertek.com/building Ak Test Report No.: C4826.01-450-18 Report Date: 4/18/2016 Architectural Testing fr t k � Photograph No. 1 Exterior View www.archtest.com . www.intertek.com/building Test Report No.: C4826.01-450-18 Architectural Testing Report Date: 4/18/2016 1 i '� s ...SIR # k Et s r�<' v: k . h, # sf_ 63, Photograph No.2 Interior View www.archtest.com . www.intertek.com/building $' S1 (2)114 x 2 314 SELF TAPPING SCREWS @ 2'-0"OC TO 2X10 WOOD FRAME -- --------- -------- --- ————— ———————— — i i M Ci i I i I - , I 3116 DIA BUTTONHEAD RIVETS @ j ALL CFS MEMBER CONNECTION 1 ' i (2)#10 x 1" SELF TAPPING SCREWS -_ I @ 24"oc max I o TYR ALONG DBL STUDS i � � I _ I i S2 S2 I _ I i —- °I- --.__T.. (2)1/4 x 2 314 SELF TAPPING SCREWS @ 2'-0"OC TO 2X10 WOOD FRAME z' 2, }2, 2, _._ ......................... ..........._ .............._. Test sample compliz5 witli these dc(ails. Deviation'—Ivied. ELEVATION -EXTERIOR VIEW 2epmlt C4826.01-450-I8 Date 09/11/14 Verified t;y:Stephen Grata EXTERIOR EPS SHEATHING AND SYNTHETIC STUCCO FINSIH NOT SHOWN FOR CLARITY Scale 3/4" = V-0" THEDESKMI TIOEDMWPi6ARETHEanl6NEPROPBM()FNIXGEJ FRAMMMTB4LLr-7HECOWANYWRESSCPEER4 5THE00M GfrANDPNYOTMPFOPM RIGHTS TNTHBE PL SAND MATIDNS.W REWD.CE@5,RNMfS OR MOD6I Mf6 OFTHEE DDORIENIS WNHWFTHE WESEDWMMNCRISENF OFNE(GEN MW4G SYSTEM LLB S PRORIBM BYLAW ,� NexGen Framing System,LLC Insulated SHEET Cold Formed Steel Panel SCALE w/Synthetic Stucco Finish on Exterior NexGen Framing system,LLC 11/27/2013 & 445 Stan Dr,suite 1 DATE Melbourne,FL 32904 TC Drywall Finish on Interior Office(321)43 t-6536 DRAWN wwYv.NexGenFraming.conT _ ,jS1 (2)1/4 x 2 3/4 SELF TAPPING SCREWS @ 2'-0"OC TO 2XI 0 WOOD FRAME 8- ......................................................................... FULL LENGTH GYPSUM SHEET i ————————— ———————— - ———————— ———————— .......... ....... /4 w Al 8 x 11/4" SELF TAPPING DRYWALLSCREWS 7"OC MAX PERIMETER C MAX IN THE FIELD Lu w r/ A. 1/2"GYPSUM BOARD- A. A r V V S2 S 2 Uj 4/ 4 a. Z D '4 4 (2)1/4 x 2 314 SELF TAPPING SCREWS @ 2'-0"OC TO 2XI0 WOOD FRAME I Isi A --'V Test sample.complies ILitb these deckfuls. Deviations me fluted. ELEVATION INTERIOR VIEW I�Cpcjrl itC4826.01450-18 Date 09/11/14 Verified Bv:Stephen Grala INTERIOR DRWALL SHEATHING AND STUD CONFIGURATION SHOWN Afir ONLY DRYWALL CONNECTORS SHOWN FOR CLARITY wr Scale.3/4" = V-0" ME DBM IN TH5EDRAVANGSAWTHE EXCUSUE PROPM OFNE(GEN ffAMmSffPEM LLCTHE COMPANY DNMY REWVS 1HE COPOGHTANDANYOMPROPERlY W MINIHESE RANSAND ELLVATIDNS.ANY RUM=C%,RMONS OR MODnCAIMNS OFTHM DOalMENTSWUHMIME WRSSID WfUMN COURNTOF NaGEN FRAMR6 WMM LIA IS 9MUM BY LAW 2 of 4 NexGen Framing System,LLC Insulated SHEET Cold Formed Steel Panel SCALE w/Synthetic Stucco Finish on Exterior NexGen Framing System,LLC 11/27/2013 & 445 Stan Dr,Suite I W, DATE Melboume,FL 32904 TC Drywall Finish on Interior Office(321)431-6536 DRAWN v"vw.NexGcnFr;mning.cojjj •+; W iZ JQ 1 INSIDE iV o w PF - 1 OUTSIDE HORIZONTAL SECTION S2-S2 ONLY DRYWALL CONNECTORS SHOWN FOR CLARITY 1/4" 3 518" is j-, 11/2" 5 110 FINISHED WIDTH VERTICAL SECTION S1-S1 ONLY DRYWALL AND DOUBLE STUD CONNECTORS SHOWN FOR C*RITY Test sample complies with these details. ALL FRAMING MATERIAL IS 20GA 50 KSI De'iations are noted. COLD FORMED STEEL Report C4826.01450-18 Date 09/11/14 Verified 13y:Stephen Grala Scale 3/4" = V-0" TIEDERMINTIBEDRAWIN(SAPETIEEnMfVEPROPDDYDFKMENFR*MSYSIEMn47HEMIPANYBNJrSNRM&SnECOMM ANDPNYMMPFDPBM ' IttaMINTHESEgNGANDHEVATANS.ANVRBTIODULItIXS,RL7,MSCAMODMTIDHSOFTI{BEDODRAENMWUHOUTTHEWSSEDWMTENMN-WDFNnICBnRAhMSMEM=SFTMI BYLAW 3 of 4 NexGen Framing System,LLC Insulated SHEET Cold Formed Steel Panel f SCALE - w/Synthetic Stucco Finish on Exterior NexGen Framing System,LLC u/ZT/zoi3 & 445 Stan Dr,Suite 1 DATE — '. Melbourne,FL 32904 7c Drywall Finish on Interior Office(321)431-6536 DRAWN -' www.NexGenFraming.coni 1/2"GYPSUM BOARD .5"CFS MIN 20GA STUD 0 MAX 24"O.C. �/ ; MAX.2.75"OPEN CELL SPRAYFOAM OUBLE EVERR 4'OC MAX .5 LBS DENSITY \ ! MIN.1.25"POLYURETHANE CLOSED CELL _ 2.0Ibs DENSITY SPRAY FOAM WITH EMBEDED 10 ozlvd IMPACT OPEN WEAVE GLASS, FIBER REINFORCING MESH 1"EPS SHEET 3.0 LBS DENSITY JMA = i SYNTHETIC STUCCOOR EXAMPLE: T BASF-SENERGY ALPHA BASECOAT) !( I (100%ACRYLIC) W/EMBEDED MIN 20ozlvd HIGH IMPACT OPEN WEAVE GLASS, FIBER REINFORCING MESH / SYNTHETIC STUCCO BASECOAT (FOR EXAMPLE: BASF-SENERGY ALPHA BASECOAT) (100%ACRYLIC) y W/EMBEDED MIN 20oz/yd HIGH IMPACT i OPEN WEAVE GLASS, Y ; FIBER REINFORCING MESH ACRYLIC PRIMER FOR WATER PROOFING (FOR EXAMPLE: BASF-SENERSHIELD-R) ACRYLIC FINISH STUCCO (FOR EXAMPLE: BASF-SENERGY FINISH COAT) 100%ACRYLIC i TEXTURED(CLASSIC)AND COLORED x6t sample complies with these de(ails. De:iDliens are noted. TYP. INSULATED WALL PANEL Reportf! C4826.01450-18 N.T.S. Dane 09/11/14 Verified By:Stephen Grala NO CONNECTORS SHOWN FOR CLARITY Scale 3/4" = V-0" TNEDMISIN THEE DMVMGSMTNEEXQIEM PROM YOFNoM RRMSMIM n4TNE W1PANY0ff1MPSHl STRCDPAMANDANY=0PKFEW I✓iQa DIRSERNbMDEEVATD&AWFUROD)MOIS,FEVMMORMOD61 MNSOFT13ECOOIAM%VDHOJrTIEBMZSSEDWRMICOt WOFf✓ (ONWIMS15IEI•IUT S PROKMEDB/IAW NexGen Framing System,LLC r 4 of 4 Insulated k SHEET Cold Formed Steel Panel k SCALE w/Synthetic Stucco Finish on Exterior NexGen Framing System,LLC 445 Stan Dr,Suite 1 u/v/zoi3 DATE & Melbourne,FL 32904 Tc < Drywall Finish on Interior Office(321)431-6536 DRAWN www.NexGen Fram ing.com