Loading...
HomeMy WebLinkAboutSES Foam (2) c c � &I'M-14'ADIE I . o• e DIVISION: 07 00 00—THERMAL.AND MOISTURE PROTECTION SECTION: 07 2100—THERMAL INSULATION REPORT HOLDER: SES FOAM 4008 LOUETTA ROAD,,#538 SPRING,TEXAS 77388-4405 EVALUATION SUBJECT: SES FOAM 0.5 LB SPRAY POLYURETHANE FOAM PLASTICINSULATION 1 - ICC . ICC- ICC c PMG LISTED Look for the trusted marks of Conformity! ` "2014 Recipient of Prestigious Western States Seismic Policy Council � x WSSPC Award in Excellence" INTERNA71ONAL A Subsidiary of COOECOURCIr ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not SCOT"°d specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a t recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as PS to any finding or other matter in this report, or as to any product covered by the report. . „u,, ,x„ Copyright© 2015 ICC Evaluation Service, LLC.All rights reserved. J _ ICC EVALUATION C SERVICE ICC-ES VAR Environmental Report VAR-1030 Reissued September 2015 This report is subject to renewal September 2017. www.icc-es.org/ep 1 800-423-6587 1 (562)699-0543 A Subsidiary of the International Code Council° DIVISION:07 00 00—THERMAL AND MOISTURE high-pressure, plural component SPF application PROTECTION equipment.The bio-based content is as set forth in Table 1 Section:07 21 00—Thermal Insulation of this report. REPORT HOLDER: 4.0 CONDITIONS 4.1 Code Compliance: SES FOAM See ICC-ES report ESR-3375 for compliance of the SES 4008 LOUETTA ROAD,#538 Foam 0.5 lb Foam S Polyurethane Foam Plastic Insulation SPRING,TEXAS 77388-4405 with code requirements. (713)239-0262 www.sesfoam.com 4.2 Green Codes, Standards and Rating Systems Eligibility: EVALUATION SUBJECT: The information presented in Tables 2 through 5 of this report provides a matrix of areas of evaluation and SES FOAM 0.5 lb SPRAY POLYURETHANE FOAM corresponding limitations and/or additional project-specific PLASTIC INSULATION requirements, and offers benefits to individuals who are 1.0 EVALUATION SCOPE assessing eligibility for compliance. The final interpretation of the specific requirements of the Compliance with the following environmental criteria: code rests with the Authority Having Jurisdiction. ICC-ES Environmental Criteria for Determination of Compliance for items noted as "Verified Attribute" is Bio-based Material Content(EC102),dated March 1, 2012. subject to any conditions noted in the tables. Decisions on Compliance eligibility with the applicable sections of compliance for those items noted as"Eligible for Points" in the following codes and standards: Tables 2 through 5 rests with the user of this report, and those items are subject to the conditions noted.The user is ■ 2012 International Green Construction CodeTM (IgCC) advised of the project-specific provisions that may be (see Table 2 for details) contingent upon meeting specific conditions, and the ■ ASHRAE Standard 189.1 — 2009 (see Table 3 for verification of those conditions is outside the scope of this details) report. ■ National Green Building Standard (ICC 700-2008) (see Due to the variability of costs and volume, the bio-based Table 4 for details) content percentage listed in this report is based upon weight (mass). The use of cost or volume as the method ■ ANSI/GBI 01-2010, Green Building Assessment for calculation is outside the scope of this report. Protocol for Commercial Buildings (see Table 5 for details) 6.0 BASIS OF EVALUATION 2.0 USES The information in this report, including the "Verified Attributes," is based upon submission of documentation SES Foam 0.5 lb Foam S Polyurethane Foam Plastic demonstrating compliance with the requirements set forth Insulation is used as nonstructural thermal insulating in ICC-ES EC102. (Evaluation applies to IgCC Section material in wall cavities, floor/ceiling assemblies, or in 505.2.4, item 3; ASHRAE 189.1 Section 9.4.1.3; ICC 700 attics and crawl spaces. See ICC-ES report ESR-3375 for Section 606.1;ANSI/GBI-01 Section 10.1.2.2.) more information on uses and applications. 6.0 IDENTIFICATION 3.0 DESCRIPTION Containers of SES Foam 0.5 lb Foam S Polyurethane SES Foam 0.5 lb spray-applied polyurethane foam plastic Foam Plastic Insulation are identified by a label bearing the insulation is a two-component, open-cell, water-blown, SES Foam name and address, product name, spray-applied polyurethane foam (SPF) with a nominal manufacturing date, manufacturing location and the VAR density of 0.5 Ib/ft3. The foam is sprayed in place using Environmental Report number(VAR-1030). ICC-ES Verification of Attributes Reports are issited under the ICC-ES VAR Environmental Program.These reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.7here is no it by ICC luation Service,LLC.express or implied,as to any finding or other matter in this report,or as to any product covered by the report. MINN..NN �i;rxu. C.t[GYIkOC Copyright©2015 ICC Evaluation Service,LLC. All rights reserved. Page 7 of 2 J VAR-1030 1 Most Widely Accepted and Trusted Page 2 of 2 TABLE 1—BIO-BASED MATERIAL CONTENT SUMMARY PRODUCT NAME %MEAN BIO-BASED CONTENT METHOD OF DETERMINATION SES Foam 0.5 lb Spray Polyurethane Foam Plastic Insulation 17%(+/-3%)' ASTM D6866 Note: 'Based on precision and bias cited in ASTM D6866. TABLES 2 THROUGH 5 Section Possible Number Section Intent Points Conditions Of.Use To Qualify For Points Finding TABLE 2—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2012 INTERNATIONAL GREEN CONSTRUCTION CODE Bio-based materials shall be those materials that comply with one or more of the following: 505.2.4 Bio-based content N/A 3.The requirements of USDA 7CFR Part 2902. • Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 3—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2009 ASHRAE STANDARD 189.1 A minimum of 5%of building materials used,based on cost,shall be biobased products. Biobased products shall comply with the minimum biobased contents of the USDA's Designation of Biobased Items for Federal Procurement[7 CFR Part 2902],contain the 9.4.1.3 Biobased products N/A "USDA Certified Biobased Product"label,or be composed of solid wood,engineered wood,bamboo,wool,cotton,cork,agricultural fibers,or other biobased materials with at least 50%biobased content. Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 4—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2008 NATIONAL GREEN BUILDING STANDARD(ICC 700) The following biobased products are used: (h)products with the minimum biobased contents of the USDA 7 CFR Part 2902 606.1 Biobased products 3 (i)other biobased materials with a minimum of 50 percent biobased content(by weight f 8 max or volume) Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. TABLE 5—SUMMARY OF AREA OF ELIGIBILITY WITH THE ANSI/GBI—01 (2010)STANDARD Bio-based products accounted for 1%or more of the materials used in the building. Percentage=100 x A=B,where: A=Total cost or weight of bio-based products B=Total cost or weight of all building products 10.1.2.2 Materials content— 1 Cost or weight must be used consistently • Assemblies 7 max For USDA-designated products,products meeting or exceeding USDA's bio-based content,criteria or qualifying as USDA"BioPreferred"were used. Note:USDA 7 CFR Part 2902§2907.17 sets a minimum bio-based content of 7%(10% +/-3%).SES Foam 0.5 lb Spray exceeds this minimum. • =Verified attribute fa w ' " - • e inT SucraseaITM DIVISION 7:Thermal&Moisture Protection Patent Pending Thermal Barriers: Product Description: SucrasealTM spray foam must be separated from the SucrasealTM spray foam insulation is a spray-applied,two interior of the building(occupied space) by an approved component, open cell polyurethane foam insulation 15 minute thermal barrier such as %Z' inch gypsum system. The product is formed by the reaction of board or other equivalent material. Exceptions for the patent pending resin blend and polymeric methylene thermal barrier are allowed; for example, foam plastic diphenyl diisocyanate. The resin blend is comprised of in attics and crawlspaces with limited access. Consult Polyols,additives,fire retardants and blowing agents. local building codes for requirements and restrictions. The spray applied nature of SucrasealTM spray foam International Code Council AC377—Appendix X: allows the material to flow into voids and seal cracks, Demand an insulation product that has passed ICC-ES expanding to form a seamless thermal envelope. Acceptance Criteria 377 (Spray foam insulation), Additional characteristics include high yield, high R- Appendix X. The ICC developed a sound, vetted and value (resistance to heat flow), high renewable content justified protocol for life safety when utilizing foam and excellent fire resistance. Sucraseal' is available in plastics in attics and crawlspaces. Spray polyurethane two densities. foam is a cellular plastic and will burn and flash-over (like wood) in some fire situations. You should insist on Product Uses: a spray foam that has passed Appendix X. Whether the Walls Attics Ceilings foam is covered or uncovered, Appendix X is the Crawlspaces* Ducts benchmark for life safety. SucrasealTM meets the Interior Applications requirements of Appendix X without a costly, *Ventilated in low humidity environments burdensome additional ignition barrier or coating. ASTM E-84: Chemical Attributes: SucrasealT"° spray foam is an ASTM E-84 (NFPA 255, Component Viscosity(25`C) Density UL723)class 1(class A)spray foam insulation. Isocyante 200 cps 10.3 Ibs/gal Flame Spread Index<25 Resin 600 cps 10.3 Ibs/gal Smoke Developed Index<450 Thickness 4 inches Storage&Shelf Life: These numerical flame spread values are not a true SucrasealTM spray foam components have an optimal reflection on how this or any material will perform in shelf life of 6 months when stored in unopened actual fire conditions. containers at temperature between 50 — 70°F. Excessively high temperatures may reduce optimal shelf life. Store material at 60 — 707 for 48 hours prior to application. USDA ICC RED -CERTI �. �r;M�ta"`asn ;a�9s�s�i�,i���ae� t ���—\.•.J � � e Y AIL AS& Ails out Key Attributes: Property Test Method 1/2 lb 1 lb Apparent Density ASTM D-1622 0.5 Ibs/ft3(nominal) 1 Ibs/ft3(nominal) R-value(aged) ASTM C-518(757 mean) 3.7 R/in* 3.7 R/in* Compressive Strength ASTM D-1621 <5 Ibs/in2 <5 Ibs/in2 Closed Cell Content ASTM D-6226 <90%(Vol.) <90%(Vol.) Fungi Resistance ASTM G-21 Zero rating Zero rating Air Permeance ASTM E-283 <0.02 L/s-m2 <0.02 L/s-m2 Renewable Content ASTM D-6866 17% 25% Dimensional Stability,-40°F ASTM D-2126 <5%Change <5%Change Dimensional Stability,+2007 ASTM D-2126 <5%Change <5%Change Dimensional Stability,+1587&100%RH ASTM D-2126 <5%Change <5%Change *Calculated from flinch thick sample Environmental Considerations: For best results, SucrasealTM should be applied when strongly recommended that test sprays be conducted ambient conditions are between 40°F and 120°F with before installation for use in extreme temperatures. relative humidity less than 80%. When ambient conditions are below 40'F it is necessary to warm and Mixing and Heating: dry the building or substrates. It is critical to mix the SucrasealTm resin component very thoroughly before and during application. Graco helical Substrate Preparation: screw type mixers are the minimum recommended All surfaces must be clean and dry, free of dirt, oil, type. The isocyanate and resin components should be solvents, grease and loose particles for optimal heated to 105°F before application. For specific adhesion. SucrasealTM spray foam bonds tenaciously to recommendations, please contact SES Foam LLC. most clean substrates. Moisture content of wood products should be < 18% and concrete must age at Material Change-over: least 28 days before application of Sucraseal'rm spray When changing spray foam systems it is necessary to foam can occur. Consult SES Foam for specific flush water through the resin transfer pump, hose and recommendations on primers or substrates. proportioner. (NEVER flush water through the isocyanate assembly. Incompatibility issues may ensue Service Temperature: if proper flushing is not done. General guidelines are SucrasealT"" spray foam insulation is designed to be used for 1 gallon per 50 ft of hose length. in ambient temperatures from-407 and 200T. It is if 7 AML USDA IM f . CERURED O P �� "� PRODUCTDUCT i" J1E w..0 Al I DO NOT MIX OTHER MANUFACTURERS RESIN OR Safety and Handling Information: ISOCYANATE COMPONENTS WITH SUCRASEAL — It is critical to read and become familiar with the SIGNIFICANT PROCESSING ISSUES MAY OCCUR. Material Safety Datasheets prior to working with SucrasealTM spray foam liquid components. During Processing Parameters: application respiratory protection is required for the SucrasealTM spray foam is designed to be applied by applicator and bystanders or helpers. For more trained contractors using high pressure, plural information - consult Material Safety datasheets, component spray proportioners. The spray www.sesfoam.com,orwww.spraypolyurethane.ore proportioner must be able to maintain the designed temperature and pressure for SucrasealTM spray foam products: A/B/Hose Temperature 120-140°F A/B Dynamic Pressure 1000- 1500lbs/in2 Optimal spray settings will vary with proportioner, hose dimensions, gun configuration and ambient conditions. It is critical for sprayers to understand the limitations associated with their equipment. Pass thickness: Sucrasealym spray foam should be applied at a minimum thickness of 2 inches and a maximum thickness of 6 inches. If greater than 6 inch thickness is desired, sprayers should wait a minimum of 10 minutes between passes. Disclaimer: The descriptions,data,designs and information contained herein are presented in good faith and believed to be accurate. This information is provided for guidance ONLY.Many factors will affect the processing or application of SES Foam LLC products,it is necessary that you make tests to determine ultimate suitability for SES Foam LLC products for your particular application. No warranties of any kind, either expressed or implied, including warranties of merchantability or fitness for a particular purpose,are made regarding products described,data or designs presented. In no case shall the descriptions, information, data or designs provided be considered a part of our terms and conditions of sale. All information and technical assistance is given without warranty or guarantee and is subject to change without notice. You expressly agree to release SES Foam LLC from all liability in tort or contract based on the technical information provided. All such information is accepted at your own risk. e. ->> use : �ICCCERTIRED BIOBASED Evan s PRDOUCT aat� sn } ... �■ e o, a f oars` EVALUATION RET Nu e R € Originally Issued: 01/16/2015 Revised: 12/04/2015 Valid Through: 01/31/2017 EVALUATION SUBJECT: 3.0 PRODUCT DESCRIPTION SES 2.0 SPRAY FOAM INSULATION 3.1 Properties: SES 2.0 Spray Foam Insulation.is a spray- REPORT HOLDER: applied, .polyurethane foam plastic and complies as SES Foam,LLC medium-density insulation in accordance with Section 4008 Louetta Road,#538 3.1.1 of AC377. The insulation is a two-component spray Spring,Texas 77388 foam plastic with a nominal in-place density of 2.0 pcf(32 www.sesfoam.com kg/m3). CSI Division:07 THERMAL AND MOISTURE The spray-applied insulation is mixed in the field by PROTECTION combining a polymeric isocyanate (A component) and a CSI Section: 072100 Thermal Insulation resin blend(B component).The liquid components shall be stored in 55-gallon(208 L)drums at temperatures between 1.0 SCOPE OF EVALUATION 50°F and 70OF(10°C and 21°C).When Component A and Component B are stored in factory-sealed containers at the 1.1 Compliance to the following codes & regulations: recommended temperatures,the maximum shelf life is six • 2015,2012 and 2009 International Building Code® months. (IBC) • 2015, 2012 and 2009 International Residential 3.2 Thermal Resistance (R-Values): SES 2.0 Spray Code®(IRC) Foam Insulation has a thermal resistance (R-Value) at a • 2015, 2012 and 2009 International Energy mean temperature of 750F(24°C) as shown in Table I of Conservation Code®(IECC) this report. • 2010 Florida Building Code (2010 FBC)-See attached Supplement Table 1—Thermal Resistance R-Value 1.2 Evaluated in accordance with: Thickness R-Value • ICC-ES AC377,approved May 2015 (inch) °F•ft2•h/Btu 1 6.6 1.3 Properties assessed: 2 13 • Physical Properties 3 20 • Thermal Resistance(R-Values) 3.5 23 • Surface Burning Characteristics 4 27 • Exterior Walls Type 1,II,III or IV Construction 5 33 • Air Permeability 6 40 • Vapor Permeance 7 47 • Attic and crawl space installations 7.5 50 • Alternate Thermal Barrier Assemblies 8 53 2.0 PRODUCT USE 9 60 10 67 SES 2.0 Spray Foam Insulation complies with IBC Section 11 73 2603, IRC Section R316, 2015 and 2012 IECC Sections 11.5 77 C303, C402, R303, and R402, and 2009 IECC Sections 12 80 303 and 402. When installed in accordance with Section ForSI: 1 inch=25.4mm,1°F•ft'-h/Btu=0.176 110 K-m/W. 4.0 of this report, SES 2.0 Spray Foam Insulation can be 'R-Values are calculated based on tested K values at 1-inch and 3.5- inch thicknesses. used in wall cavities, floor assemblies Or ceiling z R-Values greater than 10 are rounded to the nearest whole number. assemblies, or in attic and crawl spaces as nonstructural thermal insulation material.The spray-applied foam plastic 3.3 Surface Burning Characteristics: At a maximum insulation is used in Type V-B construction under the IBC thickness of 4.0 inches(102 mm)and a nominal density of and in dwellings under the IRC. The spray-applied foam 2.0 pcf(32 kg/m3),the SES 2 lb Spray Foam Insulation has plastic insulation may be used in Type I, lI, III or IV a flame spread index of 25 or less and smoke-developed construction when installed in accordance with Section 4.6 index of450 or less when to to ' a cordance.with ASTM of this report. E84.The spray foam may b th c n ed behind a prescriptive therm ' ie a The product described in this Uniform Evaluation Service(UES)Reort has been evaluated as an alternative material,design or method of construction in order to satisfy and comply with the � intent of the provision of the code,as noted in this report,and for at least equivalence to that prescribed in the code in quality,strength,effectiveness,tin:resistance,durability and safely,asc applicable,in accordance with IBC Section 104.11. Copyright©2015 by International Association of Plumbing and Mechanical Officials.All rights reserved.Printed in the United States.No part of this publication may be reproduced,stored in an electronic retrieval system,or transmitted,in any form or by any means,electronic,mechanical,photocopying,recording or otherwise,without the prior written permission of the publisher. Ph:1-677-41ESRPT•Fax:909.472.4171•web:www.uniform-es.org•4755 East Philadelphia Sheet,Ontario,California 91761-2816—USA sari UES EVALUATION REPORT Nurillberi TM Originally Issued: 01/16/2015 Revised: 12/04/2015 Valid Through: 01/31/2017 3.4 Air Permeability: When tested in accordance with Barrier: The thermal barrier required by IBC Section ASTM E2178 at a minimum thickness of 1 inch(25.4 mm), 2603.4 or IRC Section R316.4 may be omitted when all of SES 2.0 Spray Foam Insulation is classified as an air- the following apply: impermeable insulation in accordance with Section 1203.3 a. The thickness of SES 2.0 Spray Foam Insulation of the 2015 IBC,and Section R806.5 of the 2015 and 2012 does not exceed 8'/a inches(210 mm)on walls and IRC or Section R806.4 of the 2009 IRC,as applicable. other vertical surfaces and 10% inches (260 mm) on ceilings and other horizontal and overhead 3.5 Vapor Permeance: When tested in accordance with surfaces;and the ASTM E96 desiccant method(Procedure A), SES 2.0 b. The SES 2.0 Spray Foam Insulation is coated with Spray Foam Insulation has a vapor permeance of less than a minimum 18 mils(0.46 mm)wet film thickness 1.0 perms [57.4 x 10' g/(Pa•s•m')], at a minimum (12 mils [0.30 mm] dry film thickness)of DC-315 thickness of V/s inch(41-.3 mm)and qualifies as a Class II Fireproof Paint intumescent coating as described in vapor retarder in accordance with IBC Section 202 and Section 3.6 of this report. The coating shall be IRC Section R202. applied in accordance with the coating manufacturer's instructions and this report. 3.6 DC-315 Fireproof Paint:DC-315 Fireproof Paint is a Surfaces to be coated shall be dry,clean and free of water-based latex intumescent coating manufactured by dirt,loose debris and other contaminants that could International Fireproof Technology,Inc.and is supplied in impact adhesion of the coating. 5 gallon (19L) pails and 55-gallon (208L) drums. When stored in factory-sealed containers at temperatures between 4.5 Installation for Attics and Crawl Spaces: When 407(4°C)and 90°F(320C),the coating has a shelf life of used in an attic or crawl space where entry is made 24 months. only for service of utilities SES 2.0 Spray Foam Insulation shall be installed in accordance with this 4.0 DESIGN AND INSTALLATION section. The insulation shall be separated from the interior of the building by an approved thermal barrier 4.1 Design: SES 2.0 Spray Foam Insulation shall comply as described in Section 4.3,4.4 and 5.2 of this report, with requirements in 2015 and 2012IECC Sections C402.1 as applicable. and R402, or 2009 IECC Section 402, as applicable. The manufacturer's published installation instructions for SES 4.5.1 Installation with a Prescriptive Ignition Barrier: 2.0 Spray Foam Insulation and this report shall be available Where entry is made only for the service of utilities,SES and strictly adhered to at all times on the jobsite during 2.0 Spray Foam Insulation may be installed within attics installation. or crawl spaces with an ignition barrier in accordance with IBC Section 2603.4.1.6,or IRC Sections R316.5.3 4.2 Installation: SES 2.0 Spray Foam Insulation shall be and R316.5.4,as applicable. The ignition barrier shall be spray-applied on the jobsite using a volumetric positive installed in a manner such that the foam plastic insulation displacement pump in accordance with the manufacturer's is not exposed,and is consistent with the requirements of published installation instructions. The applied insulation the type of construction required by the applicable code. shall be sprayed in multiple passes having a maximum thickness of 2 inches (50.8 mm) per pass up to the 4.5.2 Installation without a Prescriptive Ignition maximum insulation thickness specified in this report.The Barrier: When installation is in accordance with this maximum in-service temperature for all areas shall not section,the ignition barrier specified by Section 2603.4.1.6 exceed 180°F (82°C). The spray-applied foam plastic of the IBC or Sections R316.5.3 and R316.5.4 of the IRC, insulation shall not be used in electrical outlets or junction as applicable,may be omitted. boxes or in continuous contact with rain or water. The spray-applied foam plastic insulation shall be sprayed onto 4.5.2.1 General: When SES 2.0 Spray Foam Insulation is a substrate that is protected and clean from any debris or installed in attics and crawl spaces without a prescriptive weather related conditions during application. ignition barrier,the following conditions apply: a. The thickness of the foam plastic insulation applied 4.3 Installation with a Prescriptive Thermal Barrier: to the underside of the top of the space shall not SES 2.0 Spray Foam Insulation shall be separated from the exceed 11%inches(292 mm). interior by an approved thermal barrier of minimum%inch b. The thickness of the foam plastic insulation applied thick (12.7 mm) gypsum wallboard or an equivalent to the vertical surfaces shall not exceed 7'/2 inches thermal barrier. When installed in accordance with this (190 m). section the spray foam may be any thickness when installed c. Entry is only to service utilities in the attic or crawl behind a prescriptive thermal barrier. The barrier shall space and no storage is permitted. comply with, and be installed in accordance with IBC Section 2603.4 or IRC Section R316.4,as applicable. d. Attic or crawl space areas cannot be interconnected. 4.4 Installation without a Prescriptive Thermal e. Air from the attic or crawl space cannot be Page 2 of 5 UESEVALUATION REPORT TM Originally Issued: 01/16/2015 Revised: 12/04/2015 Valid Through: 01/31/2017 circulated to other parts of the building. 5.2. Except as indicated in Section 4.3 and Section 4.4 of f. In accordance with IBC Section 1203.2 or IRC this report or by the applicable code, the insulations shall Section R806, as applicable, attic ventilation is be separated from the interior of the building by a code provided,as applicable. approved thermal barrier. g. In accordance with IBC Section 1203.3 or IRC Section R408.1, as applicable, crawl-space 5.3. As noted in Sections 3.1 and 3.2 of this report, the ventilation is provided,as applicable. insulations shall not exceed the nominal density and h. In accordance with IMC(International Mechanical thickness. Code®)Section 701,combustion air is provided. 5.4. During installation the insulation and the surfaces to 4.5.2.2 Attics and Crawl Spaces: SES 2.0 Spray Foam which it is applied shall be protected from exposure to Insulation may be spray-applied in attics to the underside weather. of roof sheathing,roof rafters and/or vertical surfaces,and in crawl spaces to the underside of floors and/or vertical 5.5. The contractors that will be installing the insulations surfaces as described in this section. When applied to the shall be certified by SES Foam,LLC. underside of the top of the space,the thickness of the SES 2.0 Spray Foam Insulation shall not exceed 11% inches 5.6.Use of the insulation in areas of"very heavy"termite (292 mm),and when applied to vertical surfaces maximum infestation shall be in accordance with 2012 IBC Section thickness shall not exceed 7'/z inches(190 mm). The SES 2603.9,or 2009 IBC Section 2603.8,or IRC Section 318.4, 2.0 Spray Foam Insulation does not require the application as applicable. of either an ignition barrier or a fire protective coating. Optional:If desired, SES 2.0 Spray Foam Insulation may 5.7 The insulation at a 15/8-inch (41.3 mm) thickness or be coated with 4 mils(0.1 mm)wet film thickness(2.7 mils greater is a Class II vapor retarder as defined in Section dry film thickness [0.07 mm])of DC-315 Fireproof Paint R202 of the IRC and Section 202 of the IECC. as described in Section 3.6. 5.8.Labeling and jobsite certification of the insulation and 4.5.3 Unvented Attics: SES 2.0 Spray Foam Insulation coatings shall comply with IRC Sections N1101.4 and may be installed in unvented attic assemblies and unvented N1101.4.1, IECC Sections 303.1.1 and 303.1.2, as enclosed rafter assemblies in accordance with Section applicable. 1203.3 of the 2015 IBC or Section R806.5 of the 2015 and 2012 IRC, or Section R806.4 of the 2009 IRC, as 5.9 The insulations produced at SES Foam,LLC, located applicable. in St. Louis, Missouri shall be under a quality control program with inspections by Quality Control Consultants, 4.6 Exterior Walls of Buildings of Type 1, II, 111 or IV LLC. Construction. When SES 2.0 Spray Foam Insulation is used in exterior walls of buildings of Type I, II, 1II or IV 5.0 LIMITATIONS construction of any height the insulation shall comply with Section 2603.5 of the IBC and this section. SES 2.0 Spray 6.0 SUBSTANTIATING DATA Foam insulation shall be installed at a maximum thickness of 4-inches(102 mm). 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation, AC377, dated 4.6.1 Complying Exterior Wall Assemblies. Wall May 2015, including reports of tests in accordance with assemblies that comply with Section 2603.5 of the IBC and Appendix X of AC377. this report that may be used in exterior walls of buildings of Type I, II, III or IV construction of any height are 6.2 Reports of room corner testing in accordance with NFPA described in Table 2 of this report. 286. 5.0 LIMITATIONS 6.3 Reports of fire characteristics testing in accordance with NFPA 285. The SES 2.0 Spray Foam Insulation described in this report complies with those codes listed in Section 1.0 of this 6.4 Reports of potential heat of building material testing in report or is considered a suitable alternative to what is accordance with NFPA 259. specified,subject to the following conditions: 5.1 The insulation shall be installed in accordance with the 6.4 Reports of water vapor transmission testing in manufacturer's published installation instructions. It shall accordance with ASTM E96. also be installed in accordance to this evaluation report and the applicable code,and if there are any conflicts between the manufacturer's published installation instructions and this report,the more restrictive governs. Page 3 of 6 h x u ES EVALUATION r 1` . ® ir �4� d TM Originally Issued: 01/16/2015 Revised: 12/04/2015 Valid Through: 01/31/2017 7.0 IDENTIFICATION The spray foam insulation containers are identified with the following: a. Manufacturer's name(SES Foam,LLC) b. address and telephone number, c. the product trade names(SES 2 lb Spray Foam Insulation) d. use instructions e. density,flame-spread and smoke-development indices f, date of manufacture or batch/run number g. the IAPMO Uniform ES evaluation report number(ER-- 374)and Mark of Conformity h. the name or logo of the inspection agency (Quality Control Consultants,LLC) Each container of the DC-315 Fireproof paint is labeled with the manufacturer's name (International Fireproof Technology,Inc.),the product name,and use instructions. Either Mark of Conformity may be used as shown below: 'APMO UES ES 00 or TM IAPMO ER#374 Brian Gerber,P.E.,S.E. Vice President,Technical Operations Uniform Evaluation Service Richard Beek,PE,CBO,MCP Vice President,Uniform Evaluation Service GP Russ Chan CEO,The IAPMO Group For additional information about this evaluation report please visit www.uniform-es.ora or email at info,'a)uniform-es.org Page 4 of 6 4 r VESEVALUATION REPORT TM Originally Issued: 01/1 61201 5 Revised: 12/04/2016 Valid Through: 01/31/2017 Table 2—NFPA 285 Complying Exterior Wall Assemblies Wall Component Material Description Base Wall System(BWS) 1—concrete wall Use either 1,2 or 3 2—concrete masonry wall 3—1 layer Of'/8-inch thick Type X gypsum wallboard installed on the interior side of minimum 35/8 inch deep minimum No.20 gauge thick steel studs spaced a maximum or 24 inches on center.Lateral bracing installed minimum every 4 feet vertically or as required. Wall stud cavities shall be filed at each floor line with minimum 4 pcf -density mineral wool e. .Thermafiber)friction fit between steel wall studs. Resilient Channel Double-leg `hat' shaped steel resilient channel, minimum 30 gage, installed when used with BWS 3 above perpendicular to the wall studs (interior side only) and spaced a maximum of 24- inches on center between steel studs and Type X gypsum wallboard.Entire perimeter of window opening to be framed with resilient channel. Perimeter Fire Barrier Perimeter fire barrier system complying with Section 715.4 of the 2012 IBC shall be System installed,as applicable,to fill the void created at the intersection of the exterior curtain wall assembly and the concrete floor slab. Interior Insulation 1—None Use either 1, 2, 3, 4 or 5; or 2—Maximum 35/8 inch thickness of SES Foam 0.5 lb(Sucraseal 0.5)applied to the combination of 3 and 4; or interior surface of BWS 1 or 2 above.`,4 combination of 3 and 5 3—SES Foam 0.5 lb(Sucraseal 0.5)applied to the full depth of the wall stud cavity ,or less,with exterior gypsum sheathing(see BWS 3 above)as the substrate covering thh width of the cavity and the inside of the steel wall stud framing flange 4 4—Fiberglass batt insulation(faced or unfaced) 5—Mineral wool insulation faced or unfaced Exterior Sheathing 1—None(for BWS 1 or 2 above) Use either 1,2 or 3 2—%inch thick exterior gypsum sheathing(for BWS 3 above) 3—1/8 inch thick Type X exterior type gypsum sheathing for BWS 3 above) Exterior Insulation Maximum 4-inch thick SES Foam 2.0 Spray Foam Insulation' Exterior Wall Coverine 1 — Brick - steel brick veneer anchors, installed a maximum 24-inches on-center, Use either 1,2,3,4 or 5 vertically on each stud with maximum 2-inch air gap between exterior insulation and brick.Brick to be standard nominal 4-inch thick clay brick installed in a running bond pattern using Type S mortar. 2—Stucco - minimum %-inch thick, exterior cement plaster and lath. A secondary water-resistive barrier(WRB) shall be installed between the exterior insulation and the lath. The Secondary WRB shall not be full-coverage asphalt or butyl-based self- adhering membranes. 3—Minimum 2-inch thick natural stone.Joints shall be mortared(non-open jointed). 4—Minimum 1%z-inch thick concrete masonry unit,pre-cast concrete or artificial cast stone.Joints shall be mortared. 5—Minimum 1%a-inch thick terra cotta.Joints shall be mortared. Flashing of windows,doors or As an option,flash around windows,doors and other exterior wall penetrations with other exterior wall limited amounts of maximum 12-inch wide flashing tape (acrylic, asphalt or butyl- penetrations based)or liquid-applied membrane material with or without fiber mesh reinforcement. SI: I inch=25.4 mm; 1 pcf=16.0 kg/m3; 1 Btu/ft2=0.01128 mJ/mz I Fireblocking per Section 718 of the 2012 IBC and thermal barrier material requirements per Section 2603.4 of the 2012 IBC shall be met for Base Wall Systems 1 and 2,as required by specific wall construction details when a combustible concealed space is created on interior side of exterior wall assembly. 2 Exterior wall coverings shall be installed in accordance with the manufacturer's installation instructions and shall comply with the provisions of Chapter 14 of the IBC and Chapter 7 of the IRC,as applicable. e The potential heat of 4 inch thick SES 2.0 Spray Foam Insulation is 2,066 Btu/ftz per inch of thickness when tested in accordance with NFPA 259. 'The potential heat of 31/8 inch thick SES 0.5 lb Spray Foam Insulation is 466 Btu/ftz per inch of thickness when tested in accordance with NFPA 259. Page 5 of 5 ti V ES ' EVALUATION L , ' e TM Originally Issued: 01/16/2015 Revised: 12/04/2015 Valid Through: 01/31/2017 FLORIDA SUPPLEMENT SES 2.0 SPRAY FOAM INSULATION CSI Section: 072100 Thermal Insulation 1.0 RECOGNITION SES 2.0 Spray Foam Insulation evaluated in IAPMO UES Evaluation Report ER-374 is a satisfactory alternative to the following codes and regulations: • 2010 Florida Building Code, Building (FBC, Building) • 2010 Florida Building Code, Residential (FBC, Residential) 2.0 LIMITATIONS 2.1 Installation of spray foam insulation in exterior walls of one-story building located in High-Velocity Hurricane Zones shall comply with Section 2612.3.2.3 of the Florida Building Code,Building. 2.2 Installation of spray foam insulation in exterior walls of multistory buildings located in High-Velocity Hurricane Zones shall comply with Section 26-12.3.2.4 of the Florida Building Code,Building. 2.3 The clearance between the foam insulation installed above grade and exposed earth shall be in accordance with Section 2603.8 of the FBC, Building or Section R318.6 of the Florida Building Code,Residential,as applicable. 2.4 Verification shall be provided that a quality assurance agency audits the manufacturers quality assurance program and audits the-production quality of products,in accordance with Section (5)(d) of Florida Rule 61G20-3.008. The quality assurance agency shall be approved by the Commission(or the building official when the report holder does not possess an approval by the Commission). For additional information about this evaluation report please visit www.uniform-es.ore or email at inforZuniform-es.ore SES Foam,LLC 4408 Louetta Road,#538 Spring,Texas 77388 www.sesfoam.com Page 1 of 1 Q., a SES 2 lb Spray Foam Insulation Division 7: Thermal & Moisture Protection14to polyurethane systems Product Description: ASTM E-84 SES 2 lb spray foam insulation is a spray-applied, two SES 2 lb spray foam is an ASTM E-84(NFPA 255,UL723)class 1 component, closed cell polyurethane foam insulation system. (Class A)spray foam insulation. The product is formed by the reaction of proprietary resin Flame Spread Index<25 blend and polymeric methylene diphenyl diisocyanate. The Smoke Developed Index<450 resin blend is comprised of Polyols, additives, fire retardants Thickness 4 inches and blowing agents. These numerical flame spread values are not a true reflection on how this or any material will perform in actual fire The spray applied nature of SES 2 lb spray foam allows the conditions. material to flow into voids and seal cracks, expanding to form a monolithic structure with high R-value (resistance to heat Thermal Barriers: flow). SES 2 lb spray foam can form various control layers for SES 2 lb spray foam must be separated from the interior of the buildings and structures: insulation, air barrier, moisture building (occupied space) by an approved 15 minute thermal retarder and weather barrier. barrier such as %" inch gypsum board or other equivalent material. Consult local building codes for requirements and Product Uses: restrictions. Cold Storage Walls Attics Crawlspaces Tanks Pipe Insulation Chemical Attributes: Exterior Applications Ducts Foundations Component Viscosity(250C) Density Concrete slab Isocyante 200 cps 10.3 Ibs/gal Resin 700 cps 10.3 Ibs/gal Typical Physical Attributes: Propertyt Test Method Value Apparent Density ASTM D-1622 2 Ibs/ft3(nominal) R-value(aged) ASTM C-518 6.7 R/in* Compressive Strength ASTM D-1621 25 Ibs/in' Tensile Strength ASTM D-1623 20 Ibs/in2 Closed Cell Content ASTM D-6226 >90%(vol.) Water Vapor Transmission ASTM E-96 <2 perm-inches Water Absorption ASTM D-2842 <2% Dimensional Stability,-20°F ASTM D-2126 <5%Change Dimensional Stability,+158°F ASTM D-2126 <10%Change Dimensional Stability,+158°F&100%RH ASTM D-2126 <10%Change Ignition Barrier(Alternative) AC 377 Appendix X Pass without coating** Thermal Barrier(Alternative) NFPA 286 DC315 @ 89 ftZ/gal *Calculated from 3.5-inch thick sample. C **No storage permitted and no circulation of air with the rest of the structure. For full restriction, 7 e a S representative. ■■■.e esentat►ve. _ P - r t These values are typical. However values will vary and should not be considered part of the product specifications. It`is— imperative that the trained applicator read and understand this technical datasheet and MSDS to process the material correctly and understand environmental and equipment limitations. Storage&Shelf Life: SPF Processing Parameters: SES 2 lb spray foam components have an optimal shelf life of 6 SES 2 lb spray foam is designed to be applied by trained months when stored in unopened containers at temperature contractors using high pressure, plural component spray between 50-707. Excessively high temperatures may reduce proportioners. The spray proportioner must be able to optimal shelf life. Store material at 70-90°F for48 hours prior maintain the designed temperature and pressure for SES 2 lb to application of the product. spray foam products: Environmental Considerations: A/B/Hose Temperature 120- 140°F A/B Dynamic Pressure 1000-1500 Ibs/in2 SES 2 lb spray foam insulation is available in two grades for various environmental conditions: Optimal spray settings will vary with proportioner, hose dimensions, gun configuration and ambient conditions. It is AMBIENT TEMPERATURE critical for sprayers to understand the limitations associated Regular Winter with their equipment. 50- 110°F 30-80°F Pass thickness: Wind speeds in excess of 10 mph may cause loss of exotherm SES 2 lb spray foam should be applied at a minimum thickness or cause overspray onto adjacent objects or structures. It may of%inch and a maximum thickness of 2 inches. If greater than be necessary to use wind screens. 2 inch thickness is desired,sprayers should wait a minimum of Substrate Preparation: 10 minutes between passes. All surfaces must be clean and dry, free of dirt, oil, solvents, Safety and Handling Information: grease and loose particles for optimal adhesion. SES 2 lb spray It is critical to read and become familiar with the Material foam bonds tenaciously to most clean substrates. Moisture Safety Datasheets prior to working with SES 2 lb spray foam content of wood products should be< 18%and concrete must liquid components. During application respiratory protection age at least 28 days before application of SES 2 lb spray foam is required for the applicator and bystanders or helpers. For can occur. Consult SES Foam for specific recommendations on more information consult Material Safety Datasheets, primers or substrates. www.sesfoam.com,or www.spraypolyurethane.ore Service Temperature: SES 2 lb spray foam insulation is designed to be used in ambient temperatures from -407 and 200°F, 220°F intermittent. It is strongly recommended that test sprays be conducted before installation for use in extreme temperatures. The descriptions,data,designs and information contained herein are presented in good faith and believed to be accurate. This information is provided for guidance ONLY. Many factors will affect the processing or application of SES Foam LLC products,it is necessary that you make tests to determine ultimate suitability for SES Foam LLC products for your particular application. No warranties of any kind,either expressed or implied,including warranties of merchantability or fitness for a particular purpose,are made regarding products described,data or designs presented. In no case shall the descriptions, information,data or designs provided be considered a part of our terms and conditions of sale. All information and technical assistance is given without warranty or guarantee and is subject to change without notice. You expressly agree to release SES Foam LLC from all liability in tort or contract based on the technical information provided. All such information is accepted at your own risk. insuL m� Physical Properties of Insulfoam EPS A J caCuWPAnrY The physical properties provided in this manual are average Certification values determined by Insulfoam, Insulfoam raw material sup- Insulfoam must be notified at the time materials are ordered pliers and independent testing agencies.Testing results were if product must be certified to meet an ASTM or other speci- obtained under controlled laboratory conditions and do not fication and/or must bear an Underwriters Laboratories, Inc represent minimum standards. Insulfoam is not obligated to (UL) or Factory Mutual (FM} label or marking. Insulfoam will manufacture its products per a designer's specifications or perform the required tests and certify that materials meet physical standards unless agreed to in advance by Insulfoam. specifications,with or without exception, upon acceptance of It is the purchaser's obligation to ensure any purchased In- the order. sulfoam materials meet a specification's physical properties. .. . .. 1ype (il,. ", ty ®,f%.g. ., ,-: tp�ISr ? tl+pg°XIV. TypeXU y; Tt3st,t�ettrod NOtSfln81[58aii}Y�pbf} 1.0 1.25 1.5 2.0 2.50 3.0 ASTM C303 C yalue fCnn�lu�ancet� 'S�; ',gyp' ST�U�hr*its ASTM C518 .230 .220 .210 .200 0.198 0.196 or 1perirtcfl) r@AO F' .240 .235 .220 .210 0.206 0.198 ASTMC177 .260 .255 .240 .230 0.222 0.217 �t#V'alufi�larmat psistance)- a� � z {b'itY ASTM C518 r " M � 25'� 4.35 4.55 4.76 5.00 5.05 5.10 or I (pef inctfj y ,' 40-eF 4.17 4.25 4.55 4.76 4.85 3.92 4.17 5.05 ASTM C177 3.85 4.357.': . 4.60 y �rir`mptes INC 3trangttr 0 10-14 13-18 15-21 25-33 40 60 ASTM D1621 t�0�a�at�ern� � { FleXt_444e 0111t t1 psi;_" 25 30 35 50 60 75 ASTM C203 ' nehstonalidtiy gf tmaXlntUrn°} 2% 2% 2% 2% 2.0 2.0 ASTM D2126 y��Vlratar uapoP f�O eanc®,zq_ maid erm 1 r 5.0 3.6 3.5 2.0 2.5 2.5 ASTM E96 YVat91'1r,�j50rpti0l{{F11 GY o , . 4.0 3.0 3.0 2.0 2.0 2.0 ASTM C272 r Ca NI none none none none none none ` Gamy SjirFad # r `,° <20 <20 <20 <20 <20 <20 ASTM E84 # utlit)k�De,.ji 150-300 1 150-300 1 150-300 1 150-300 150-300 1 150-300 ASTM E84 Typicaf Physical Rrooertwsa .TYPe .TYPe7C� r Testdllett►isci '< r�Co► P69s&' strengths 13 16 20 28 ASTM D1621 4s1,10/a C13Ojt�rlatiatt}. j ;: FCt: uraF S#rtf #tt"(psi ' 33 40 50 70 ASTM C203 W er or Arafnsmissto '; r <1.0 <1.0 <1.0 <1.0 ASTM E96 r. :; sti�ptGi {ala 1t0I)�y r <1.0 <1.0 <1.0 <1.0 ASTM C272 P�fest{ss5re�as�slanat��rovtdeitbYresinYnnuf3tcturers independariktastagenoiesandlnsu!foam ✓ n{+ �' www.insulfoam.com Tel: ".248.5995 Manufacturing in: Alaska-Arizona-California - Colorado-Florida-Nebraska-Utah-Washington