HomeMy WebLinkAboutHEALTH DEPARTMENTAPPLICATION # : AP 1400084 STATE OF FLORIDA PERMIT #:56-SF-1927626 DEPARTMENT OF HEALTH DOCUMENT # : FI 1555124 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:07/12/2019 FEE PAID:25.00 RECEIPT #:56-PID-4013307 APPLICANT: Francisco & Peggy Perez AGENT: AlexanderJ. Piazza PSM, Inc PROPERTY ADDRESS: TBD Orange Ave Fort Pierce, FL 34945 LOT: BLOCK: SUBDIVISION: ID# : 2310-412-0002-000-7 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1500.00 [2] [ ] [27] SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [301 PUBLIC WELLS FT [ ] [05] OUTLET FILTER PolylokPL-68 [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-156-15SC3 2. [ ] [32] POTABLE WATER 16 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 7 FT [ ] [081 LEVEL [ ] [34] PROPERTY LINES 53 FT [ ] [091 DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 900 [21 SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 6.00 2. [ ] [381 SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [391 STABILIZATION 09/01/2020 [ ] [14] DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 6.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [421 AIMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [47] CONTRACTOR (OWNER) [ ] [221 FILL AMOUNT [ ] [48] OTHER INFILTRATOR ARC 24 [ ] [23] FILL TEXTURE [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. / St. Lucie CHID DATE: 03/25/2020 CONSTRUCTION [ APPROVED DISAPPROVED ] ' Envinon ental Specialist B -i i i J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: le St. Lucie CHD DATE: 09/01/2020 Environmental Specialist II rian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1400084 EID1927626 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1400084 PERMIT #:56-SF-1927626 DOCUMENT #:F11555124 DATE PAID.07/12/2019 FEE PAID:25.00 RECEIPT #:56-PID-4013307 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 500 gpd. New ST, filter, and 6x10 long DF installed. No violation, system ok to cover. Owner/builder notified by phone. Needs final nspection for mound system and final site grading. =inal system approved. Building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1400084 EID1927626