HomeMy WebLinkAboutBLOWER DOOR•ram.. �_��s �� z. r--'.;: x
Planning , Development. Services
Building P. Code Liegulation Mvisian
23®0 Virginia Ave, Rrn 29l
retort Pierce, R 3490.2
Phone: 772-462_2,. 6S Fax: 772-462-64e.3
B[ OWL.-E, DOOR TCS
1i as u5 pnel 0. ean U esi l��P$la'arsc��Ur�t
PrescPGp&e and PDerfo�4r�c�4�C��
Date: ,_�
�mnxa•a�t�r: a G o Peed
Address:
S 3 d� � w, �r
i r
4�5trL9� i�U9: ' rK; C_
1�i1141y®n5EP34�6©6� YSl
®CC)
rjpj C- 6 a CjihSL.�d
° g ma
i louse lr'fl'trat'On Test Results
UM (50) ' SLC C111-na•te zone
OILIMe = Z s esi ira e I Z 19 �7 2 :�
Acl r (50) = CFM (SO) ac �0 3 . �
23
Passing results must be / Volume =
%IQEC,iG171CG1 J��ii of of i reaL! i ao' iess 1170h it :'
�" ric,-1 (��) Or less
(V Pass i ) Fail
i"BC, Ene�•gs! �
she building or dwelling unit shall be tested and v f not
hour in Climate Zone 1 verified as having an air 2 and air changes per hour in Climate Zones 3 througli Skage . ieste o�ing shall b eXceeticonducted levith
blower door at a pressure o� 0.2 inches w. g! air changes per
Section 553.993(5) or (7), Florida Statutes or individuals licensed as seing ll be conducte
d by either individuals as de -fined
approved third party. A written report oI the results o� the =a _ north in Section ^89.105 din
Provided to the code Official. Testing shall be Performed at
any Small a e signed by the ()(�i (t e (i) a an
pery conducting the test and
rnErmal envelope, of all Penetrations of the building
s-QC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower
Pressure of 0.2 inch w. c. (50 Pa) in accordance with Section P,a02.c�.1.2 or'the
the dwelling unit shall be provided with whole -house mechanical ventilation i� accordance l!lwith Section Energy COdoor
oservation
Yestin>; Coml�as�v
N11507.3.
Company Name: Pro -Duct Services
'ddress: -1915 Rio Vista Drive, Ft. Pierce, FL 3='949
I hereby cerdn/ that the above House Infiltration results demonstrate compliance with F8C Energy Conserva
requirements in accordance wifI Section R^02.!!.1.2 Climate gone 2.
Lion
Signature
Printed Name: Man cin IClein
Lice nse/Cerciiication #- 5061633
BUILDING PERFORMANCE
INSTITUTE, INC.
107 Hermes Road, Suite 210
Malta, NY 12020rc
(377) 274-1274
='
www.bpi.org06,
;.
.
eBPIsm
Martin Klein
BPI ID#: 5061633
(SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES)
CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE
Infiltration & Duct I.cakap (IDI,) 4,262021
BUILDING PERFORMANCE INSTITUTE, INC.