HomeMy WebLinkAboutProduct Approval 7
ifs'
s- �' r-.r 11�fi af,�F«,- t .r+•` l
,( t r "r � x .� .i N 3h F�� a � r s_ t�a��.?�� .a {{. •'• y ti,� I y t }}
g.
ili 3IFs zl "t I��t�iPi� frl }t ��+li �� I � ..;# r. l1 as
t..x t'3 r <..:..z..`'(i+ {,_ :.�...i 1,;�.:�t;'�'�-,.�..>, rs..j.�r���Y-f�.,,�'�ri ti,: �iS,'t.�;�++ �S�")1�` I'✓!, 7f tt�j�}�t'r`1tr t i�..+%:r
• ...•.•... .sL._�_.a. .;Tt<'._9J._f.+l Y.vY. 1':.fl k :... v..f
iii;�i31:'i�;itli;silit! BCISHome Login UserReglsUatlon Hot Topics F Submit Surcharge Slats Facts Publications i FBCStaff BCIS Site btap I Links S Search
r
Busines ��i)
Professh—la"I r ► Product Approval
;,iMj• ,USER:Product
licA User
4'
1�0 )Uhtbll
Product Anoroval Menu>Product or Aooliration Search>Apollcation Us t>Application Detail '
r+z FL# FL20717
COP7!� Y
i .'' Application Type NewCodo Version 2014 LE
Application Status Approved
Comments
Archived
Product Manufacturer Carolina Carports,inc.
Address/Phone/Email 187 Cardinal Ridge Trail
Dobson,NC 27017
(336)367-6400
FLvalidation@yahoo.com
Authorized Signature robert cope
Jason.c@cclhq.biz
Technical Representative RECEIVED ,
Address/Phone/Erroll
Quality Assurance Representative APR 10 2017
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the Terrence E.Wolfe CONCULED FASTENERS OR ATTACHMENTS Evaluation Report
Florida License PE-44923 ARE THE RESRONSIBI!!1Y OF THE
Quality Assurance Entity Keystone Certifications,Inc.
Quallty Assurance Contract Expiration Date 03/14/2017 OFREWRD
Validated By Locke Bowden
'i' Validation Checklist-Hardcopy Received
Certificate of Independence FL20717 RO COi Letter of Cedification odf
Referenced Standard and Year(of standard) Standard ear
ASTM E 1592 2005
FM 4471 1992
Equivalence of Product Standards
Certified By
Sections from the Code TH91 Ovw PL�14-8 AM ALL PROPOSED WORM
ARE SUBJECT TO ANY COFIRECTIONS
'RE-QUIRED BY FIELD iNSPECTORS THAT
PLAY BE NECESSARY IN..QfttMA.Tt�_..........._.._...
Product"APproval Method._........._........................._..................Method i Option D..._................-...................._...._.......
CGfXr':f WITH ALL APPI.J^AME CGUC&
Date Submitted 06/16/2016
Date Validated 07/21/2016
Date Pending FBC Approval 07/28/2016
_ i
Date Approved 10/13/2016
= Surttrttary oFPraducts__ '
-- -._.._._-...... _._...__...__....._....._....._..._.._.__.............-._. _.._.............._............._.._.......—----------- ........ ......................_.........._....--•----...._................
PL 0 Glade],Number or Name — Description
20717.1 26 Ga.AG Roof Panel 26 Ga.AG Roof Panel over Open Framing
c Limits of Use Installation Instructlons
Approved for use In HVHZ:No FL20717 RO )I 26 Ga. AG Roof Panel Detall.pdf
Approved for use outside HVHZ:Yes Verified By:Terrence E.Wolfe,P.E.44923
Impact Resistant:N/A Created by Independent Third Party;Yes
Design Pressure,446.9 psf/-59.9 psf Evaluation Reports
Other:See Evaluation Report for additional design pressures. FL20717 RO AE 26 Ca.AG Roof PaneJ.pd(
Install per manufacturer's details.Not for use in HVHZ Zones. Created by Independent Third Party:Yes
Boar Hmt
Contact Us::2601 Blair Stone Road.Tallahassee FL 37399 Phone:850-4B7-1824
'The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.;:Privacy Statement;;Accessibility Statement:;Refund Statement
UnderFlorida law,email addresses are public records.If you do not%%ant your e-mail address released in response to a public-records request,do not send
electronic mall to this entity.instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter455,F.S.must provide the Department Wth an email address if
they have one.The emalls provided may be used'for Of dal communication Wth the licensee.Hoiveveremail addresses are public record.If you do not Wsh to
supply a personal address,please provide the Department with an email address%%hlrh can be made available to the public To determine If you are a licensee
under Chapter455,F.S.,please dick here_.
product Approval Acceptsi
Credit Card
Safe
LE ,COPY
Force Engineerilig&Testing Inc.
19530 Ramble\vood Drive
Humble,TX 77338
Product Evaluation Report
CAROLINA CARPORTS, INC.
26 Ga.AG Roof Panel over open framing
Florida Product Approval # 20717.1
Florida Building Code 2014
Per Rule 61G20-3
Method:1—D
Category:Structural Components
Subcategory:Roof Deck
Compliance Method:61G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Carolina Carports,Inc.
187 Cardinal Ridge Trail
• Dobson,NC 27017
Engineer Evaluator: h C
P
Terrence E.Wolfe,P.E.#44923
Florida Evaluation ANE ID:1920
h ( (Df
Validator:
Locke Bowden,P.E.,FL#49704
9450 Alysbury Place
Montgomery,AL 36117
Contents:
Evaluation Report Pages 1—4
0
C E N
j � No.449k�
e
STATE OF ;ar `
AZ O R I ID p` "k'
s,w orrtmi% �i Fs;•. ti
CAA ' 'r .
r�sna I`� o N IL {► ,,,
FL#20717.1
JUNE 16, 2016
' Force Engineering&Testing Inc.
19530 RambleNvood Drive
Humble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2014,Sections 1504.3.2,1504.7.
Product Description: AG Roof Panel, 26 Ga. Steel, 36" Wide, through fastened structural roof panel.
Structural Application.
Panel Material/Standards: Material: 26 Ga.Steel,ASTM A792 or ASTM A653 G90 conforming to Florida
Building Code 2014 Section 1507.4.3. Optional paint finish.
Yield Strength: Min.80.0 ksi
Corrosion Resistance:Panel Material shall comply with Florida Building Code
2014,Section 1507.4.3.
Panel Dimension(s): Thickness: 0.0200"min.coated thickness
Width: 36"maximum coverage
Rib Height: W major rib at 9"O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener: #12-14 x%" HWH SD#3 with 5/8"(16mm)diameter sealing washing or approved
equal.
Corrosion Resistance:Per Florida Building Code 2014,Section 1506.6,1507.4.4
Substrate Description: Minimum 14 Ga.(Grade 50)Steel tube framing or Minimum 18 Ga.(Grade 50)
Steel hat channel purlins/girts. See Table A for steel gauge. Framing must be
designed in accordance w/Florida Building Code 2014.
Design Pressures:
Table"A"
Maximum Design Pressure: -59.9 psf -62.5 psf -83.3 psf +46.9 psf +57.3 psf
Panel Fastener Pattern: 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1
Panel Span: 5'-0"O.C. 4'-0"O.C. 4'-0"O.C. 5'-0"O.C. 4'-0"O.C.
Substrate: Min.14 Ga. Min.18 Ga.Steel Min.14 Ga.Steel Min.18 Ga. Min.18 Ga.
Steel Framing Framing Framing Steel Framing I Steel Framing
*Design Pressure includes a Safety Factor=2.0.
LE
COPY
,`',1ff11r1fI`��I
,�� ��•C E, E• iyo ii
�. •�C G�
No.444g T; U
STATE OF
%D,e- FZ o R x
O
A� .,Es•. vti
FL#20717.1 JUKE lb 2016
a
Farce Engineering&Testing Inc.
19530 Ramblewood Drive
EIumble,TX 77338
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2014,Section 1504.3.2,1504.7.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014,as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ ASTM E 1592-05 Test method for structural performance of sheet metal
roof and siding systems by uniform static air pressure difference
■ FM 4471-92-Foot Traffic Resistance Test
Reference Data: 1. ASTM E 1592-05 Test
Force Engineering&Testing,Inc.(FBC Organization#TST-5328)
Report No.183-0063T-16A-E
2. FM 4471-10,Section 4.4 Foot Traffic Resistance Test
Force Engineering&Testing,Inc.(FBC Organization#TST-5328)
Report No.183-0109T-12,&183-0142T-15
3. Certificate of Independence
By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc.
(FBC Organization#ANE ID:1920)
Test Standard Equivalency: The FM 4471-10,Foot Traffic Resistance'test standard is equivalent to
FM 4471-92.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005(3)for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014,including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12,lap sealant must be used in the panel side laps.
EffInstallation: Install per manufacturer's recommended deto'llss. G{ COPY
Insulation: Manufacturers approved product(Optional)
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
`
ND.44q.C��/,�; j pry
STATE of ;Qr
smrorr�da, ,,ice�E; AZ 4 RI.� ;�
FL#20717.1 JUNE 16 2016
1 '
Force Engineering&Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure,appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2014 for roof cladding
wind loads.These component wind loads for roof cladding are compared to the
allowable pressure listed above.The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover.Support framing must be in compliance with Florida Building Code 2014
Chapter 22 for steel,and Chapter 16 for structural loading.
F ,` L
COPY
N,C E- �-
.O
C E H S F
No.444
STATE OR
626779
FL#20717.1
JUNE 16, 2016