Loading...
HomeMy WebLinkAboutAPPROVED window door scehedule€1 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE LOCATION Corner Zone WINDOW GLAZING ACCEPTANCE APPROVED PRESSURE RATING DESIGN PRESSURE M OPENING WINDOW SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER PSF (-)PSF (+)PSF {-)PSF TESTED DIMENSIONS MULLION REQ YIN SIZE REQ YININA 1. Int rr,i°d°,� '" `� FL15781.1I 55 60 35.0 -38.2 73x63 73x62 No No 2 Int rr'i°15�, ';, ,�n` ° FLI5781.1.1 55 60 35.1 -38.3 73 x c3 72x61 No No 3 End rr i"a°�'' '" `°""`; FL15781.11 55 60 36.4 -47.8 73 G3 52x49 No No 4 lot rNu,a° 'G"' FLI.5781..11 55 60 36.4 -39.6 73 x 63 52x49 No No 5 End r°'i€,Lt�"�` "h `�^ '�; FL15781.11 55 60 36.4 -47.8 73 x 63 52x49 No No 6 End w;na� " `'° `� FL15781.11 55 60 37.8 -50.6 73 x 63 3607 No No 7 End Window 7/8"Lwllii It', FL15781.11 55 60 35.9 -46.8 73x63 51x61 No No 8 Int Window '° FL15779.3 50 50 37.8 -41 .0 36x 72 24x23 No No 9 End Will ow TF,i,"'i10, FL15781.11 55 60 359 -46.7 73 x G3 52x61 No No 10 End Window FL1.5781.11 55 60 35.7 -46.5 73 x 63 55x61 YES No 11 Int Window 718"UmiIG FL15781.11 55 60 35.7 -38.9 73., 63 55x61 YES No