Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CCF_000313/engery cal'cs manual j
Bell Res HVAC Load Calculations for Ando Building Corporation 389 Sebastian Blvd Sebastian, FL. 32958 RHVACHVAC o os Prepared By: Karen O'Brien A/C Service Masters, LLC 1473 Ashboro Circle SE Palm Bay, FL. 32909 321-615-6562 Monday, December 28, 2020 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. - --- - - — — ---.. Bell Res hvac -Residential &Light Commercial HVAC Loads Elite Software Development,Inc. ' ' A/C Service Masters, LLC Palm B FL 32909 --. -- --- — - ---- Bell Res 1 Project Report General. -Project Information Project Title: Bell Res Designed By: John O'Brien Project Date: 12/28/2020 Client Name: Ando Building Corporation Client Address: 389 Sebastian Blvd Client City: Sebastian, FL. 32958 Client Phone: 772-589-5943 Client Fax: 772-589-5943 Company Name: A/C Service Masters, LLC Company Representative: Karen O'Brien Company Address: 1473 Ashboro Circle SE Company City: Palm Bay, FL. 32909 Company Phone: 321-615-6562 Company Fax: 321-956-9451 Company E-Mail Address: acservicemasters@yahoo.com Company Comment: Reference City: Fort Pierce, Florida Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Dry Bulb We Winter: 42 39.4 Summer: 90 78 Outdoor R I H um Indoor Rel.Hum Indoor Grains n/a n/a Dry Bulb 72 Difference n/a 59% 50% 75 61 Check Figures - Total Building Supply CFM: 1,600 CFM Per Square ft.: 0.731 Square ft. of Room Area: 2,189 Square ft. Per Ton: 582 Volume (ft3): 18,858 Building Loads - Total Heating Required Including Ventilation Air: 44,442 Btuh 44.442 MBH Total Sensible Gain: 34,759 Btuh 83 Total Latent Gain: 7,327 Btuh 17 % Total Cooling Required Including Ventilation Air: 42,086 Btuh 3.51 Tons (Based On Sensible +Latent) 3.76 Tons (Based On 77% Sensible Capacity) i Notes ., 4 fld Rhvac is an ACCA approved Manual J, Dsand S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. i All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads _- Elite Software Development, Inc. A/C Service Masters, LLC Palm Bay FL 32909Bell Res_ _ Page 3 _- Miscellaneous Report System 1 Main Floor Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data - Winter: Dry Bulb -Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Summer: 42 39.4 80% n/a 72 n/a 90 78 59% 50% 75 61.09 Duct Sizing Inputs Calculate: Main Trunk Yes R'no is Yes Use Schedule: No No Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. F Outside Air Data t� Infiltration Specified: Winter 0.320 AC/hr Summer 0.160 AC/hr 101 CFM 50 CFM Infiltration Actual: 0.320 AC/hr 0.160 AC/hr Above Grade Volume: X 18 858 Cu.ft. X 18 858 Cu.ft. X 6,035 0.0167 Cu.ft./hr 3,017 Cu.ft./hr Total Building Infiltration: 101 CFM X 0.0167 50 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) Winter Infiltration Specified: 0.320 AC/hr (101 CFM), Construction: Average Summer Infiltration Specified: 0.160 AC/hr (50 CFM), Construction: Average Duct Load Factor Scenarios forstem 1 _ No,._eDescriptio..n _ Location ..___ Attic Ceiling_ Duct -_-_Leakage -- Duct Insulation Surface Area From (T]MDD 1 Supply Main Attic 16B 0.12 6 591 No 1 Return Main Attic 16B 0.24 6 547 No E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads A/C Service Masters, LLC .Palm Bay. FL 3290O-- load Preview Report ... ....... Elite Software Development, Inc.' Bell Res Page 4 Scope _---� Neq Recl ft.1� Se La Ne Se 9 J 0 To Tod -!To Are GailGailGai Loss Ht CI Ac CFM CFM CFM Buildinq 3.51 3.76 582 2,189 34,759 7,327 42,086 44,442 1,600 1,600 1,600 Svstem 1 3.51 3.76 582 2,189 34,759 7,327 42,086 44,442 1,600 1,600 1,600 Supply Duct Latent 509 509 Return Duct 7,341 2,681 10,022 2,064 Zone 1 2,189 27,418 4,137 31,555 42,377 1,600 1,600 1.600 1-Master Bedroom 255 3,805 822 4,627 6,895 260 222 222 2-Master Bath 330 1,994 363 2,357 7,483 283 116 116 3-Foyer 63 571 84 655 1,561 59 33 33 4-Dinina 143 1,198 177 1,375 3,163 119 70 70 1 5-Grt Room 306 2,824 145 2,969 4,577 173 165 165 1 6-Kitchen / Nook 340 6,650 1,046 7,696 3,930 148 388 388 2 7-Bath 3 54 686 125 811 2,241 85 40 40 1 8-Den Closet 30 294 91 385 1,526 58 17 17 1 9-Den 143 2,868 321 3,189 1,786 67 167 167 1 10-Bed 2 174 2,317 351 2,668 2,338 88 135 135 1 11-Bath 2 51 278 50 328 923 35 16 16 1 12-Bedroom 3 195 2,657 454 3,111 3,904 147 155 155 1 13-Utility 105 1,275 108 1,383 2,051 77 74 74 1 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads A/C Service Masters, LLC Elite Software Development, Inc. IF - _ ,. -- ,:. Bell Res Duct Size Preview Page-S Room or Duct Name Source Minimu Veloci Max!mu Veloci Rough Facto Desig�L.ss U10elocit Duc Duc Htg Clg L Act. Duct Lengt Flow - ipgFlo e Svstem 1 Supply Runouts Zone 1 1-Master Bedroom Built -In 450 750 0.01 0.1 565.4 260k, A 222 2--6 2-Master Bath Built -In 450 750 0.01 0.1 592.6 283 -i 16 116 4--3 3-Fover Built -In 450 750 0.01 0.1 339.5 59 M3 33 2--3 4-Dininq Built -In 450 750 0.01 0.1 512.7 119m0 70 1--5 5-Grt Room Built -In 450 750 0.01 0.1 472.1 173����"65 165 1--8 6-Kitchen / Nook Built -In 450 750 0.01 0.1 555.9 148&i88 388 2--8 7-Bath 3 Built -In 450 750 0.01 0.1 458.8 85MO 40 1--4 8-Den Closet Built -In 450 750 0.01 0.1 350 58V 17 17 1--3 9-Den Built -In 450 750 0.01 0.1 479.5 6711 167 167 1--8 10-Bed2 Built -In 450 750 0.01 0.1 506 881,35 135 1--7 11-Bath 2 Built -In 450 750 0.01 0.1 743.6 35=6 16 1-2 12-Bedroom 3 Built -In 450 750 0.01 0.1 580.2 147=5 155 1-7 13-Utility Built -In 450 750 0.01 0.1 545.6 77M, 74 1-5 Other Ducts in System 1 Supply Main Trunk Built -In 550 600 0.003 0.1 554.6 1,600M, 1,600 23 Summary Svstem 1 Heating Flow: 1600 Cooling Flow: 1600 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads A/C Service Masters, LLC L.Ralm Bay FL 32909 j Equipment Data - System 1 - Main Floor Cooling System Type: Air Source Heat Pump Outdoor Model: ML16XP1-048-230A Indoor Model CBA27UHE-048-230+TDR Tradename: ML16XP Outdoor Manufacturer: LENNOX Description: Air Source Heat Pump AHRI Reference No.: 202908484 Capacity: 46,000 Efficiency: 16 SEER Elite Software Development, Inc,' Bell Res Page F Heating System Type: Air Source Heat Pump Model: ML 16XP 1-048-230A Tradename: ML16XP Manufacturer: LENNOX Description: Air Source Heat Pump Capacity: 43,000 Efficiency: 9.5 HSPF This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 72F, Sen. gain: 34,759 Btuh, Lat. gain: 7,327 Btuh, Sen. loss: 44,442 Btuh, Entering clg. coil DB: 79.2F, Entering clg. coil WB: 63.9F, Entering htg. coil DB: 70.8F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1247 CFM, Req. htg. airflow: 551 CFM E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM -Residential &Light Commercial HVAC Loads A/C S A/C Service Masters, LLC Elite Software Development, Inc. Palm Bay, FL 32909 �. w .e.r ., r B ell Res Detailed Room Loads -Room 1 - Master Bedroom (Average Load ` Procedure) Page Gen eral ,,, Calculation Mode: Htg. & clg. Occurrences: Room Length: 17.0 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: Ceiling Height: 255.0 sq.ft. Supply Air: 222 CFM Volume: 8.1 ft. Supply Air Changes: 6.4 AC/hr Number of Registers: 2,066 2 cu.ft. Req. Vent. Clg: 0 CFM Runout Air: 111 CFM Actual Winter Vent.: Percent of Supply.: 0 0 CFM Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 565 ft./min. Percent of Supply: 0 Runout Air Velocity: 565 ft./min. Actual Winter Infil.: 17 CFM Actual Loss: 0.204 in.wg./100 ft. Actual Summer Infil.: 9 CFM N -Wall-13A-4fcs 11 X 8.1 E -Wall-13A-4fcs 15 X 8.1 S -Wall-13A-4fcs 17 X 8.1 N -Wall-12C-Obw 5 X 1 E -GIs-3A-v-o shgc-0.23 3%S S -GIs-3A-v-o shgc-0.23 100%S (2) UP-Ceil-16C-30 17 X 15 Floor-22A-rm 48 ft..Per. Subtotals for Structure: Infil.: Win.: 17.5, Sum.: 8.7 Ductwork: AED Excursion: People: 230 lat/per, 300 sen/per: Equipment: Room Totals: Ceiling fan Color television Desk radio or clock radio Total 89.1 0.117 3.5 313 100 0.117 3.5 351 121.7 0.117 3.5 427 5 0.091 2.7 14 21.5 0.350 10.5 226 16 0.330 9.9 158 255 0.032 1.0 245 48 1.180 64.9 3,115 4,849 353 1.630 576 1,470 2 6,895 Cont. Cont. Output Output Sens. Lat. 250 0 683 0 52 0 1.8 0 159 1.8 0 179 1.8 0 218 1.1 0 5 11.7 0 252 9.8 0 156 1.3 0 326 0.0 0 0 0 1,295 0.408 362 144 765 29 460 600 0 972 822 3,805 Avg. Pct Sens. Lat. -Use Used Load Load 100 100 250 0 100 100 683 0 75 100 39 0 972 0 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads - A/C Service Masters, LLC Elite Software Development, Inc. Palm Bay. FL 329t]9 Bell R es „ . �. - - Detailed Room Loads -Room 2 _- Master Bath (Average Load Procedure) Page i General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 22.0 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: Ceiling Height: 330.0 sq.ft. 8.1 ft. Supply Air: 116 CFM Volume: Supply Air Changes: 2.6 AC/hr Number of Registers: 2,673 cu.ft. 4 Req. Vent. Clg: 0 CFM Runout Air: Actual Winter Vent.: 0 CFM 29 CFM Percent of Supply.: 0 Runout Duct Size: 3 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 593 ft./min. Percent of Supply: 0 Runout Air Velocity: 593 ft./min. Actual Winter Infil.: 17 CFM Actual Loss: 0.596 in.wg./100 ft. Actual Summer Infil.: 9 CFM N -Wall-13A-4fcs 5 X 8.1 40.5 0.117 3.5 142 1.8 0 72 W -Wall-13A-4fcs 15 X 8.1 106.5 0.117 3.5 374 1.8 0 191 S -Wall-13A-4fcs 22 X 8.1 172.2 0.117 3.5 604 1.8 0 308 N -Wall-12C-Obw 13.5 X 1 13.5 0.091 2.7 37 1.1 0 15 W -GIs-3A-v-o shgc-0.21 3%S 15 0.330 9.9 149 24.7 0 370 S -GIs-3A-v-o shgc-0.23 100%S 6 0.300 9.0 54 9.3 0 56 UP-Ceil-16C-30 22 X 15 330 0.032 1.0 317 1.3 0 422 Floor-22A-rm 56 ft..Per. 56 1.180 64.9 3,634 0.0 0 0 Subtotals for Structure: Infil.: Win.: 5,311 0 1,434 17.5, Sum.: 8.7 354 1.631 577 0.407 363 144 Ductwork: 1,595 401 AED Excursion: Room Totals: 15 7,483 363 1,994 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac -Residential 8 Ligh t nercial HVAC Loads Elite Software Development, Inc. A/C Service Masters, LLC n : Bell Res Palm Bay, FL 32909 - ---- Page 9 Detailed Room Loads - Room 3 --Foyer (Average Load Procedure)General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 7.0 ft. System Number: 1 Room Width: 9.0 ft. Zone Number: 1 Area: 63.0 sq.ft. Supply Air: 33 CFM Ceiling Height: 9.1 ft. Supply Air Changes: 3.5 AC/hr Volume: 573 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 17 CFM Percent of Supply.: 0 Runout Duct Size: 3 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 339 ft./min. Percent of Supply: 0 Runout Air Velocity: 339 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.199 in.wg./100 ft. Actual Summer Infil.: 2 CFM - Item m - - Area ------------------ -U- Htg Sen Clg ---- Lat Sen l Quantity Value HTM I nce I-ITKA r-!n I W -Wall-13A-4fcs 9 X 9.1 W -GIs-10C-f shgc-0.13 100%S (2) i UP-Ceil-16C-30 7 X 9 Floor-22A-rm 9 ft..Per. Subtotals for Structure: Infil.: Win.: 4.0, Sum.: 2.0 Ductwork: AED Excursion: Room Totals: Equipment Cooling_Loads Item Name __- Color television Ceiling fan Miscellaneous Equipment Total 41.1 0.117 3.5 40.8 0.250 7.5 63 0.032 1.0 9 1.180 64.9 82 1.636 Cont. Output Sens. Btuh 683 250 -933 144 1.8 0 74 306 6.5 0 264 60 1.3 0 81 584 0.0 0 0 1,094 0 419 134 0.403 84 33 333 115 4 1,561 84 571 Cont. Output Avg. Lat. In -Use Btuh _ Output 0 100 0 100 0 100 Pct Used /Hour 100 100 100 Sens. Load Btuh 683 250 -933 0 Lat. Load Btuh_j 0 0 0 0 -- -- - _ E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM -Residential &Light Commercial HVAC Loads ---- Elite Software Development, Inc.. A/C S A/C Service Masters, LLC Bell Res I Palm Bay FL 32904 etailed Room Loads - Room 4 - Dining (Average Load Procedur SUL Page 0 1. Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 11.0 ft. System Number: 1 Room Width: 13.0 ft. Zone Number: 1 Area: 143.0 sq.ft. Supply Air: 70 CFM Ceiling Height: 9.1 ft. Supply Air Changes: 3.2 AC/hr Volume: 1,301 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 70 CFM Percent of Supply.: 0 Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 513 ft./min. Percent of Supply: 0 % Runout Air Velocity: 513 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: 0.217 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item -- — Area -U- Htg Sen Cig — Lat Sen Description Quantity_ Value HTM Loss HTM rain rain W -Wall-13A-4fcs 14 X 9.1 91.4 0.117 3.5 321 1.8 0 164 S -Wall-13A-4fcs 5 X 9.1 45.5 0.117 3.5 160 1.8 0 81 W -GIs-3A-v-o shgc-0.21 80%S (2) 36 0.330 9.9 356 12.5 0 450 UP-Ceil-16C-30 11 X 13 143 0.032 1.0 137 1.3 0 183 Floor-22A-rm 19 ft..Per. 19 1.180 64.9 1,233 0.0 0 0 Subtotals for Structure: 2,207 0 878 1 Infil.: Win.: 8.5, Sum.: 4.3 173 1.631 282 0.405 177 70 Ductwork: 674 241 AED Excursion: 9 Room Totals: 3,163 177 1,198 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. A/C Service Masters, LLC Bell Res Palm Bay, FL 32909_ _ 1,96 Page 11 Detailed Room Loads - Room 5 - Grt Room (Average Load Procedure) General Calculation Mode. Htg. & cig. Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 18.0 ft. Zone Number: 1 Area: 306.0 sq.ft. Supply Air: 165 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 3.2 AC/hr Volume: 3,060 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 165 CFM Percent of Supply.: 0 % Runout Duct Size: 8 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 472 ft./min. Percent of Supply: 0 i Runout Air Velocity: 472 ft./min. Actual Winter Infil.: 7 CFM Actual Loss:_ 0.096 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item Area U ` Htg Sen Clg fiat Senn Desertion_____-_— Quantity Va1tJe HTM Loss HTM Gain Gain) E-Wall-13A-4fcs 12 X 6.8 0 0.117 3.5 0 1.8 0 0 E -Wall-12C-Obw 12 X 2.3 27.6 0.091 2.7 75 1.1 0 30 E -Wall-13A-4fcs 3.5 X 8.1 28.4 0.117 3.5 100 1.8 0 51 E -Wall-12C-Obw 3.5 X 1 3.5 0.091 2.7 10 1.1 0 4 E -GIs-3A-v-o shgc-0.19 100%S (4) 81.6 0.360 10.8 880 9.4 0 768 UP-Ceil-16C-30 17 X 18 306 0.032 1.0 294 1.3 0 392 Floor-22A-rm 31 ft..Per. 31 1,180 64.9 2,012 0.0 0 0 Subtotals for Structure: 3,371 0 1,245 Infil.: Win.: 7.0, Sum.: 3.5 141 1.631 230 0.404 145 57 Ductwork: 976 568 AED Excursion: 21 Equipment: 0 933 Room Totals: 4,577 145 2,824 Equipment Cooling Loads l !, Cont. Cont. Output Output Avg. Pct Sens. Lat. Sens. Lat. In -Use Used Load Load Item Name_-________Btuh Btuh Out u� t _../Hour Btuh_ Btuh Ceiling fan 250 0 100 100 _ 250 0 Color television 683 0 100 100 683 0 Total 933 0 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room b room.rh9 1 y Monday, December 28, 2020, 1:56 PM vac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. A/C Service Masters, LLC Bell Res _Palm Bay, FL 32909 1 1 li, Page_12 Detailed Room Loads - Room 6 - Kitchen / Nook (Average Load Procedure) General " - - _ _- Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 20.0 ft. Zone Number: 1 Area: 340.0 sq.ft. Supply Air: 388 CFM Ceiling Height: 9.1 ft. Supply Air Changes: 7.5 AC/hr Volume: 3,094 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 194 CFM Percent of Supply.: 0 % Runout Duct Size: 8 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 556 ft./min. Percent of Supply: 0 % Runout Air Velocity: 556 ft./min. Actual Winter Infil.: 7 CFM Actual Loss: 0.133 in.wg./100 ft. Actual Summer Infil.: 4 CFM SE-Wall-13A-4fcs 6 X 6.8 E -Wall-13A-4fcs 8.5 X 8.1 SE-Wall-13A-4fcs 2 X 8.1 SE-Wall-12C-Obw 6 X 2.3 SE-Wall-12C-Obw 2 X 1 SE-GIs-3A-v-o shgc-0.19 100%S (2) E -GIs-3A-v-d shgc-0.23 4%S (2) UP-Ceil-16C-30 17 X 20 Floor-22A-rm 25 ft..Per. Subtotals for Structure: Infil.: Win.: 7.0, Sum.: 3.5 Ductwork: AED Excursion: Equipment: Room Totals: Equipment Cooling Loads 0 0.117 3.5 0 1.8 44.9 0.117 3.5 157 1.8 16.2 0.117 3.5 57 1.8 13.8 0.091 2.7 38 1.1 2 0.091 2.7 5 1.1 40.8 0.360 10.8 440 9.4 24 0.300 9.0 216 25.9 340 0.032 1.0 326 1.3 25 1.180 64.9 1,622 0.0 2,861 142 1.631 231 0.409 838 3,930 Cont. Cont. Output Output Avg. Pct Sens. Lat. In -Use Used Item Name - Btuh Btuh Output /Hour Coffee maker - brewer 1331 _ 717 __ 100 25 Cooking range with hood - four burners on high heat 0 0 100 100 Toaster 3532 392 100 10 Dishwasher 4096 1433 100 25 Microwave 4949 1732 75 25 Refrigerator or freezer - 16 cubic feet 1000 0 100 100 Total 0 0 0 0 0 0 0 0 0 0 145 901 1,046 Sens. Load Btuh 333 0 353 1024 928 1000 3638 0 80 29 15 2 384 622 435 0 1,567 58 1,337 50 3,638 6,650 I Lat. Load Btuh 179 0 39 358 325 0 901 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM --- Elite Software Development, Inc.' — - -- vac - esidential & Light Commercial HVAC Loads A/C Service Masters, LLC Palm Bay, FL 32909 Bell Res es _ Page 13 Detailed Room Loads - Room 7 - Bath 3 (Average Load Procedure) General .; Calculation Mode: Htg. & clg. Occurrences: Room Length: 6.0 ft. System Number: 1 Room Width: 9.0 ft. Zone Number: 1 Area: 54.0 sq.ft. Supply Air: 40 CFM Ceiling Height: 8.1 ft. Supply Air Changes: 5.5 AC/hr Volume: 437 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 40 CFM Percent of Supply.: 0 Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 459 ft./min. Percent of Supply: 0 Runout Air Velocity: 459 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.239 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item Area -U- -_-_ Htg Sen Clg ------- -- Lat Sen DBSCripti-n_. Quantity V2111P HTKA I ncc urea -Wall-13A-4fcs 6 X 8.1 32.3 0.117 3.5 113 1.8 0 58 E -Wall-13A-4fcs 9 X 8.1 68.4 0.117 3.5 240 1.8 0 122 E -GIs-3A-v-o shgc-0.23 5%S 4.5 0.330 9.9 45 26.2 0 118 S -GIs-10C-f shgc-0.16 100%S 16.3 0.290 8.7 142 7.7 0 126 UP-Ceil-16C-30 6 X 9 54 0.032 1.0 52 1.3 0 69 Floor-22A-rm 15 ft..Per. 15 1.180 64.9 973 0.0 0 0 Subtotals for Structure: 1,565 0 493 Infil.: Win.: 6.0, Sum..- 3.0 122 1.630 198 0.412 125 50 Ductwork: 478 138 AED Excursion: 5 Room Totals.- 2,241 125 686 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc.-' A/C Service Masters, LLC Bell Res Palm Bay, FL 32909 Page 14 Detailed Room Loads - Room 8 - Den Closet (Average Load Procedure) General - Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 6.0 ft. System Number: 1 Room Width: 5.0 ft. Zone Number: 1 Area: 30.0 sq.ft. Supply Air: 17 CFM Ceiling Height: 8.1 ft. Supply Air Changes: 4.2 AC/hr Volume: 243 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 17 CFM Percent of Supply.: 0 Runout Duct Size: 3 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 350 ft./min. Percent of Supply: 0 % Runout Air Velocity: 350 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.211 in.wg./100 ft. Actual Summer Infil.: 2 CFM Item Area —U- Htg Sen Clg Lat Sen� Description _ Quantity Value " HTM t ncc -ITAit- Moir E -Wall-13A-4fcs 5 X 8.1 N -Wall-13A-4fcs 6 X 8.1 UP-Ceil-16C-30 6 X 5 Floor-22A-rm 11 ft.. Per. li Subtotals for Structure: Infil.: Win.: 4.4, Sum.: 2.2 Ductwork: ' AED Excursion: Room Totals: Equipment Cooli0g_Loads_ 40.5 0.117 3.5 48.6 0.117 3.5 30 0.032 1.0 11 1.180 64.9 Item. Name Coffee maker - brewer Cooking range with hood - four burners on high heat Toaster Dishwasher Microwave Refrigerator or freezer - 16 cubic feet Miscellaneous Equipment Total 1.627 Cont. Output Sens. Btuh_ 1331 0 3532 4096 4949 1000 -3638 142 1.8 171 1.8 29 1.3 714 0.0 1,056 145 0.404 325 1,526 Cont. Output Avg. Pct Lat. In -Use Used _Btuh Output /Hour 717 100 25 0 100 100 392 100 10 1433 100 25 1732 75 25 0 100 100 -901 100 100 0 72 0 87 0 38 0 0 0 197 91 36 59 2 91 294 Sens. Load _ Btuh 333 0 353 1024 928 1000 -3638 0 Lat. Load!. Btuh 179 0 39 358 325 0 -901 0 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. A/C Service Masters, LLC Bell Res Palm Bay, FL 32909 _.. . , ,. a .::,: _ w ... Page 15 es Detailed Room Loads - Room 9 - Den (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: Room Length: 11.0 ft. System Number: Room Width: 13.0 ft. Zone Number: Area: 143.0 sq.ft. Supply Air: Ceiling Height: 8.1 ft. Supply Air Changes: Volume: 1,158 cu.ft. Req. Vent. Clg: Number of Registers: 1 Actual Winter Vent.: Runout Air: 167 CFM Percent of Supply.: Runout Duct Size: 8 in. Actual Summer Vent.: Runout Air Velocity: 480 ft./min. Percent of Supply: Runout Air Velocity: 480 ft./min. Actual Winter Infil.: Actual Loss: 0.099 in.wg./100 ft. Actual Summer Infil.: Item Area -U- Htg Sen Cig i Description 01jnntity Value HTM I H N -Wall-13A-4fcs 11 X 8.1 N -GIs-3A-v-o shgc-0.23 100%S UP-Ceil-16C-30 11 X 13 Floor-22A-rm 11 ft..Per. Subtotals for Structure: Infil.: Win.: 4.4, Sum.: 2.2 Ductwork: AED Excursion: People: 230 lat/per, 300 sen/per: Equipment: Room Totals: Equipment Cooling Loads - Item Name Ceiling fan Color television Computer and monitor Total 1 1 1 167 CFM 8.7 AC/hr 0 CFM 0 CFM 0 % 0 CFM 0 % 4 CFM 2 CFM Lat ---- Sen 74.1 0.117 3.5 .0TM 260 1.8 vain 0 vain i 133 j 15 0.330 9.9 149 9.8 0 147 143 0.032 1.0 137 1.3 0 183 11 1.180 64.9 714 0.0 0 0 1,260 0 463 89 1.627 145 0.404 91 36 381 577 22 1 230 300 0 1,471 1,786 321 2,868 j Cont. Cont. Output Output Avg. Pct Sens. Lat. Sens. Lat. In -Use Used Load Load Btuh Btuh _ Output /Hour _Btuh Btuh_ 250 0 100 100 250 0 683 0 100 100 683 0 1536 0 35 100 538 0 1471 0 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac -Residential &Light Commercial HVAC Loads Elite Software Development, Inc. A/C Service Masters, LLC '� Palm Bay, FL 32909 Bell Res Page 16 Detailed Room Loads --Room 10 - Bed 2 (Average Load Procedure) General _ - - Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 1 Room Width: 14.5 ft. Zone Number: 1 Area: 174.0 sq.ft. Supply Air: 135 CFM Ceiling Height: 8.1 ft. Supply Air Changes: 5.8 AC/hr Volume: 1,409 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 135 CFM Percent of Supply.: 0 Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 506 ft./min. Percent of Supply: 0 Runout Air Velocity: 506 ft./min. Actual Winter Infil.: 6 CFM Actual Loss: 0.133 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item Area —U- Htg Sen Clg Lat Sen Description _ Quantity Value HTM Loss HTIM Gain Gain. N -Wall-13A-4fcs 14.5 X 8.1 102.5 0.117 3.5 360 1.8 0 183 N -GIs-3A-v-o shgc-0.23 100%S 15 0.330 9.9 149 9.8 0 147 UP-Ceil-16C-30 12 X 14.5 174 0.032 1.0 167 1.3 0 223 Floor-22A-rm 15 ft..Per. 15 1.180 64.9 973 0.0 0 0 Subtotals for Structure: 1,649 0 553 Infil.: Win.: 5.8, Sum.: 2.9 117 1.626 191 0.409 121 48 Ductwork: 498 466 AED Excursion: 17 People: 230 lat/per, 300 sen/per: 1 230 300 Equipment: 0 933 Room Totals: 2,338 351 2,317 Equip-ment Cooling Loads Cont. Cont. Output Output Avg. Pct Sens. Lat. Sens. Lat. In -Use Used Load Load Item Name Btuh Btuh Output /Hour Btuh Btuh_, Ceiling fan 250 0 100 _ 100 2.50 0 Color television 683 0 100 100 683 0 Total 933 0 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM ------- Bell Res /C S -Residential &Light Commercial HVAC Loads Elite Software Development, Inc. ' A/C Service Masters, LLC P I B FL Page 17 es Detailed Room Loads - Room 11 - Bath 2 (Average Load Procedure) Genera - Calculation Mode: Htg. & clg. Occurrences: Room Length: 6.0 ft. System Number: Room Width: 8.5 ft. Zone Number: Area: 51.0 sq.ft. Supply Air: Ceiling Height: 8.1 ft. Supply Air Changes: Volume: 413 cu.ft. Req. Vent. Clg: Number of Registers: 1 Actual Winter Vent.: Runout Air: 16 CFM Percent of Supply.: Runout Duct Size: 2 in. Actual Summer Vent.: Runout Air Velocity: 744 ft./min. Percent of Supply: Runout Air Velocity: 744 ft./min. Actual Winter Infil.: Actual Loss: 1.690 in.wg./100 ft. Actual Summer Infil.: ---------_._— itemArea--— ..------------------- -U- Htg Sen -- Cig Description. _ .._ _---_ __ ----_._---_...Quantity_ Value HTM Loss HTM N -Wall-13A-4fcs 6 X 8.1 42.6 0.117 3.5 150 1.8 N -GIs-3A-v-o shgc-0.23 100%S 6 0.330 9.9 59 9.8 UP-Ceil-16C-30 6 X 8.5 51 0.032 1.0 49 1.3 Floor-22A-rm 6 ft..Per. 6 1.180 64.9 389 0.0 Subtotals for Structure: 647 Infil.: Win.: 2.4, Sum.: 1.2 49 1.626 79 0.412 Ductwork: 197 AED Excursion: Room Totals: 923 1 1 16 CFM 2.4 AC/hr 0 CFM 0 CFM 0 % 0 CFM 0 % 2 CFM 1 CFM Lat Sen 0 76 0 59 0 65 0 0 0 200 50 20 56 2 50 278 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Lo 9 A/C Service Masters, LLC Palm Bay,-- --- Elite Software Development, Inc.' Bell Res Bell es Detailed Room Loads - Room 12 - Bedroom 3 (Average Load Procedures AN -- - Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: 195.0 sq.ft. Supply Air: 155 CFM Ceiling Height: 8.1 ft. Supply Air Changes: 5.9 AC/hr Volume: 1,580 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 155 CFM Percent of Supply.: 0 Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 580 ft./min. Percent of Supply: 0 Runout Air Velocity: 580 ft./min. Actual Winter Infil.: 11 CFM Actual Loss: 0.174 in.wg./100 ft. Actual Summer Infil.: 5 CFM N -Wall-13A-4fcs 13 X 8.1 W -Wall-12C-Osw 14 X 8.1 N -GIs-3A-v-o shgc-0.23 100%S UP-Ceil-16C-30 13 X 15 Floor-22A-rm 27 ft..Per. Subtotals for Structure: Infil.: Win.: 10.8, Sum.: 5.4 Ductwork: AED Excursion: People: 230 lat/per, 300 sen/per: Equipment: Room Totals: Equipment Cooling Loads Item Name Color television Ceiling fan Total 90.3 0.117 3.5 113.4 0.091 2.7 15 0.330 9.9 195 0.032 1.0 27 1.180 64.9 219 1.632 1 317 1.8 0 310 2.0 0 149 9.8 0 187 1.3 0 1,752 0.0 0 2,715 0 357 0.407 224 832 3,904 230 0 454 Cont. Cont. Output Output Avg. Pct Sens. Sens. Lat. In -Use Used Load -_ Btuh Btuh Output /Hour Btuh 683 0 100 100 683 250 0 100 100 250 933 162 222 147 250 0 781 89 534 20 300 933 2,657 Lat. Load, Bt 0 0 0 E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. A/C Service Masters, LLC Palm Bay, FL 32909 �+ it Bell Res Bell Detailed Room Loads - Room 13 - Utility (Average Load Procedure) General -, Calculation Mode: Htg. & clg. Occurrences: Room Length: 15.0 ft. System Number: 1 Room Width: 7.0 ft. Zone Number: 1 Area: 105.0 sq.ft. Supply Air: 74 CFM Ceiling Height: 8.1 ft. Supply Air Changes: 5.2 AC/hr Volume: 851 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 74 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 546 ft./min. Percent of Supply: 0 Runout Air Velocity: 546 ft./min. Actual Winter Infil.: 5 CFM Actual Loss: _ _ 0.245 in.wg./100 ft. Actual Summer Infil.: 3 CFM Item Area U. Htg Sen Clg Lat Sen Description �____ Quantity Value MTM Loss HIM, Gain Gain W -Wall-12C-Osw 7 X 8.1 37.7 0.091 2.7 103 2.0 0 74 S -Wall-13A-4fcs 6 X 8.1 48.6 0.117 3.5 171 1.8 0 87 W -Door-11 D 2.8 X 6.8 19 0.390 11.7 223 10.1 0 193 UP-Ceil-16C-30 15 X 7 105 0.032 1.0 101 1.3 0 134 Floor-22A-rm 13 ft..Per. 13 1.180 64.9 844 0.0 0 0 Subtotals for Structure: 1,442 0 488 Infil.: Win.: 5.2, Sum.: 2.6 105 1.633 172 0.408 108 43 Ductwork: 437 2506 AED Excursion: Equipment: 0 478 Room Totals: 2,051 108 1,275 Equipment Cooling Loads Cont. Cont. Output Output Avg. Pct Sens. Lat. Item Name_ Sens. Lat. In -Use Used Load Load Vented clothes dryer - 10 percent to space Btu--h Btuh Output. 1707 0 50 /Hour 50 Btuh__.. __ 427 ----- Bt_u_h_ Clothes washing machine - 10 percent to space 205 0 50 50 51 0 0 j Total 478 0 ' E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM Rhvac - Residential & Light Commercial HVAC Loads A/C Service Masters, LLC Palm Bay, FL 32909_ System 1 Room Load Summary K] Elite Software Development, Inc. Bell Res Page 20 Htg Min Run Run - Clg Clg Min A Room Area Sens Htg Duct Duct Sens Lat Clg Sy` No Name ---- - -- -SF-. Btuh---.- .-._CFM Size ---Zone 1--- _ 1 Master Bedroom 255 6,895 90 2-6 565 3,805 822 173 222 2 Master Bath 330 7,483 97 4-3 593 1,994 363 91 116 3 Foyer 63 1,561 20 2-3 339 571 84 26 33 4 Dining 143 3,163 41 1-5 513 1,198 177 54 70 5 Grt Room 306 4,577 59 1-8 472 2,824 145 128 165 6 Kitchen / Nook 340 3,930 51 2-8 556 6,650 1,046 303 388 7 Bath 3 54 2,241 29 1-4 459 686 125 31 40 8 Den Closet 30 1,526 20 1-3 350 294 91 13 17 9 Den 143 1,786 23 1-8 480 2,868 321 130 167 10 Bed 2 174 2,338 30 1-7 506 2,317 351 105 135 11 Bath 2 51 923 12 1-2 744 278 50 13 16 12 Bedroom 3 195 3,904 51 1-7 580 2,657 454 121 155 13 Utility 105 2,051 27 1-5 546 1,275 108 58 74 Duct Latent 509 Return Duct 2,064 7,341 2,681 System 1 total 2,189 44,442 551 34,759 7,327 1,247 1,600 System 1 Main Trunk Size: 23 in. Velocity: 555 ft./min Loss per 100 ft.: 0.024 in.wg L Cooling S�rstem Su` - -- -:- Cooling Sensible/Latent Sensib e - ._..- ---- -- --- Tons Split Bt' Net Required: 3.51 83% / 17% 34,759 7,327 42,086 Recommended: 3.76 77% / 23% 34,759 10,383 45,141 Actual: 3.92 61 % / 39% 28,670 18,330 47,000 E91Jipment.Data - Type: Heating System Air Source Heat Pump oolinQ System Air Source Heat Pump Model: ML16XP1-048-230A ML16XP1-048-230A Indoor Model: CBA27UHE-048-230+TDR Brand: ML16XP ML16XP Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 9.5 HSPF 16 SEER Sound: 0 0 Capacity: 43,000 Btuh 46,000 Btuh Sensible Capacity: n/a 28,670 Btuh Latent Capacity: n/a 18,330 Btuh AHRI Reference No.: n/a 202908484 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 72F, Sen. gain: 34,759 Btuh, Lat. gain: 7,327 Btuh, Sen. loss: 44,442 Btuh, Entering clg. coil DB: 79.2F, Entering clg. coil WB: 63.9F, Entering htg. coil DB: 70.817, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1247 CFM, Req. htg. airflow: 551 CFM E:\RHVAC 9\Projects\Ando-Bell Res- 2188-W-room by room.rh9 Monday, December 28, 2020, 1:56 PM ACCk , Ar Cariknrcj Ca0-ad�is dAmeri�; County, Town, Municipality, Jurisdiction Header Information Form RIPER 1.01 8 Mar 10 Contractor A/C Service MAsters ,LLC REQUIRED ATTACHMENTS' ATTACHED — - - Manual A Form (and supporting worksheets): Yes 0 No ❑ Mechanical License # CAC1816310 or MJ1AE Form' (and supporting worksheets): Yes ❑ No N OEM performance data (heating, cooling, blower): Yes ❑ No Building Plan # Manual D Friction Rate Worksheet: Yes ❑ Nog Duct distribution system sketch: Yes ❑ Nog Home Address (Street or Lot#, Block, Subdivision) 5242 Slash Pine Trail Fort Pierce, FL. 34951 HVAC LOAD CALCULATION.1 Design -Conditions Boil. ding -Construction -information - Winter Design Conditions Building Outdoor temperature 42 T Orientation (Front door faces) West Indoor temperature 72 T North, East, West, South, Northeast, Northwest, Southeast, Southwest Total heat loss - 44442 Btu/h Number of bedrooms -- I Summer Design Conditions Conditioned floor area 21 &9 Scl Ft Outdoor temperature aG of Number of occupants Indoor temperature _7S of Windows Grains difference - _&j Gr @_5a % Rh Eave overhang depth Ft Roof Sensible heat gain -_ 347CZ0 Btu/h Internal shade <-- Latent heat gain __ 7 27 Btu/h Blinds, drapes, etc ve D 1 p Window Total heat gain - _42D O J Btu/h Number of skylights EQUIPMENTHVAC • 41 Heating_EquipmentData CaOlincr nttinment Bata BtoweLData Equipment type _Heat pump Equipment type Heat um Furnace, Heal pump, Boiler, etc. _ _ _ ___ _-p- Heating CFM Air Conditioner, Heat pump, etc g 1-60� CFM Model - --ML16XP1-048-230A Model ML16XP1-048-230A Cooling CFM _'�-��� CFM Heating output capacity 43oD0 Btu/h Sensible cooling capacity 2U670 Btu/h Heat pumps - capacity at winter design outdoor conditions Latent cooling capacity _ 1-833-0 Btu/h Auxiliary heat output capacity Btu/h Total cooling capacity 6aoa Btu/h • •1 Design airflow 1 600 CFM Longest supply duct: Ft Duct Materials Used (circle) External Static Pressure (ESP) IWC - Trunk Duct: Duct board, Flex, Sheet metal, Longest return duct: Ft Lined sheet metal, Other (specify) Component Pressure Losses (CPL)_____ IWC Total Effective Length (TEL) Ft Branch Duct: Duct board, Flex, Sheet metal, Available Static Pressure (ASP) IWC Friction Rate: IWC Lined sheet metal, Other (specify) ASP = ESP - CPL Friction Rate = (ASP x 100) =TEL Contractor's Printed Name wren �ien. _ -__ Date Contractor's Signature Reserved for use by County, Town, Municipality, or Authority having jurisdiction. The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program.