Loading...
HomeMy WebLinkAboutProduct Approval, metal 10/12/2020 Florida Building Code Online �. IF - (TR BCIS Home Log in User Registration Hot Topics Submit surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search b Product Approval USER:Public User oi. r Pranuct APPMI:al Menu>Praducc or At pghcat,on Search>APpUceaon Lkl>Application Dfltall - = I FL 9 FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v,date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators,LLC Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 rchard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R,Priest,RE, Validation Checklist-Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr 12d Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code mvw.floridabuilding.org/prlpr app dtl.aspx?param--wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 113 a 10/12/2020 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Date Revised 10/05/2020 Summary of Products !FL# 'Model,Number or Name Description j 17022.1 1 -"5V Crimp"(R6) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel mechanically attached to 15/32"plywood or Wood Deck with fasteners i Limits of Use -------------- -- - -- --- - - - --'Installation Instructions f Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdF Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssrpdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 117022.2 2-"5V Crimp"(R6) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof panel, mechanically attached to 15/32"plywood or Wood Deck with j exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 IT FL 17022.2 5 V CRIMP 0,032 ALUM ssr.pdF Approved for use outside HVHZ:Yes Verified By: Locke Bowden,RE.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions.InstaII the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr,gd- i assembly in compliance with the installation method listed in Created by Independent Third Party: Yes 1 this report and applicable code sections of FBC. Refer to j manufacturer's installation instructions. 17022.3 3-"1.5"Mechanical Seam" (RS) 1.5"rib height, 16"wide,24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with clips and Fasteners. j Limits of Use - I Installation Instructions Approved for use in HVHZ:No FL17022 R7 TI FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ:Yes 'seam 24ga ssrpdf Impact Resistant:No Verified By: Locke Bowden,P.E.49704 Design Pressure: +N/A/Table A Created by Independent Third Party: Yes Other:Refer to evaluation report for conditions and limitations.Evaluation Reports of use.Install the assembly in compliance with the installation 1`1-17022 R7 AE FL 17022.3 1.5 MECHANICAL f method listed in this report and applicable code sections of seam 24ga ssrpdf FBC.Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes j 17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height, 16"wide,0.032"aluminum,standing seam roof j panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ:Yes ALUMINUM ssr pdd Impact Resistant:No Verified By: Locke Bowden,P.E.49704 3 Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes I Other:Refer to evaluation report for conditions and limitations.Evaluation Reports of use.Install the assembly in compliance with the installation FL17022 R7 AE FL 17022 4 MECHANCIAL SEAM j method listed in this report and applicable code sections of .ALUMINUM ssrpdf FBC.Refer to manufacturer's installation instructions. Created by Independent Third Party: Yes 17022.5 — 5-"1 in. Nail Strip"(115) 1"rib height, 16"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck j with fasteners. Limits of Use Installation Instructions — Approved for use in HVHZ:No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssrpdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 j Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A i Evaluation Reports Other:Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssrpdf 11 i I of use.Install the assembly in compliance with the installation Created by Independent Third Party:Yes II If www.floddabuilding.Orgtpr/pr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d°/a3d 2/3 i !p��m •li e q ;o o aYGidYf� r.�;a���- ��Y�atA:R -1�L"i1t� �1�.51'ltL.iriDJ��th-Ate.?-�,��,,_�.�..•0 `-,1 2160 SW Poma Drive Palm City, FL 34990 _.____j772)872-8034 11 .� Compliant with Florida Building Code 2017 (61" ed.) Compliant with Florida Product Approval Rule #61G20-3- Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min.0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex-Washer Head wood screw* to penetrate 3/16" min, thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, &4 Attachment): #10 x 1-1/2" Hex-Washer Head wood screw*to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope:Shall be in compliance with FBC Sec. 1507. See Fastener attachment specifications above l Install Details: Table A Allowable Loads _METHOD 1—r—METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE' -86 PSF -_93.5 PSF ��w -101 PSF -228 PSF ROW SPACING 16" o.c. _ 16"~o.c. ! 8"O.C. 6„o.c. FASTENER SPACING (ALONG Panel width) I 12' 9.c. 12#"1o0.c' � 12#'10c. 12#,lOc1 FASTENER SIZE Reference Data: ARCHITECTURAL TESTING,INC.TST ID#: 1527 UL 580-06& 1897-042 Test Report CM893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04;is equivalent to test standard UL 1897-1?f i r *Design Pressure margin of safety,2:1 �q71A LR,. Locke Bowden,P.E.does not have,not will acquire a financial inPot q.j C; m aq�r mkt facturing or distributing products under this evaluation. Locke Bowden,P.E.is not owned,operated,or controlled by at y coiAparNPmbb9faLtureo,or E_istributing products under this report. r 6+�S -T of r• .r' ' o �. 't'ONA� 4�.;' " I I F FL17022.1 5V Crimp (26GA Steel), 24"Wide Roof Panel - Details -imitations: 1. Underlayment to be compliance with current Florida Building Code(FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6111 ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method: 1-D 4. Engineering analysis for"project specific approval by local authorities wrurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ad., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not Imply warranty, installation, recommended product use outside of this report. Fasteners- ln 5-V Crimp Roof Panel#10x1-1/2MTaAo Spacing andAealgn Pressures Hex Washer Head Wood screws 21 3 I I i I Decic 15132"or greater Plywood,or Wood plank i 14" '12* ,JFTIOMAL STRIATIONS I Panel Profile Nominal 12" Nominal 12" o.c. O.C. Fasten 9 x -1/2"Min. or #10 x 1-1/2"Min.per -fable"A" Hex Washer Head Screw Spaced 12"o.c.across the Panel Width PanelXodplank Refer to Table'W'for Spacing Along Panel OverlapLength -15132"orgreater Plywood,or I I