HomeMy WebLinkAboutPlot Plans Survey'
_BARS X 12' LONG ti DRILLED OUT & EI O.. E¢D
� 3
II
WITH 6" MINIMUM EMBEDMENT `a 24" O.�'
'
SCOPE OF WORK
ALL AREAS ADJACENT TO EXISTING
CONSTRUCT NEW MASTER BATHROOM PER PLAN.
FOUNDATION
- REMODEL EXISTING KITCHEN PER PLAN.
- CONSTRUCT UTILITY CLOSET PER PLAN.
EXISTING CONCRETE FLOOR
FOUNDATION
THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC 2017 FOR
j
EXISTING BUILDINGS CHAPTER 7 AND 8,
b" THICK (2500 PSI) CONCRETE
SLAB OVER VAPOR BARRIER
NOTES:
ON CLEAN COMPACTED
1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL
CHEMICALLY TREATED FILL
DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT.
2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE
ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES.
3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER
SCALED DIMENSIONS.
4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE
(FBC) 2017, FBC 2017 RESIDENTIAL, FBC 2017 PLUMBING CODE, FBC 2017
MECHANICAL CODE, FBC 2017 ENERGY CONSERVATION, AND THE NEC (NFPA
70) 2014 EDITION.
F
OQR RE 'AIR D TAIL nts..
5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY
T.O
ATED AT ALL AREAS REQUIRED FOR NEW PLUMBING INSTALLATIONS
HEAVY TERMITE INFESTATION AREA PER FRC301.
- - - -
6) ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B.0
2017 FOR EXISTING BUILDINGS.
STRUCTURAL NOTES
1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10.
2) SLAB / FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE
STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS.
3) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTINGS: 3" BEAMS: 1`%" SUSPENDED SLABS: 1'/2"
4) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED.
5) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO
Vvvv
TNDO W f DOOR SCAIXIEWULEJ
MARE
SIZE / TYPETWTES
A
2 8 6 8 INTERIOR DOOR
B
5 0 6 8 INTERIOR SLIDER DOOR
C
3 0 6 8 BARN SLIDER DOOR
E
EXIST. WBVDOWS / DOORS
INSTALATION OF HARDWARE IS NOT PERMITED.
6) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE
SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD
PRACTICIES. VT4 -
WALL FINISH / INSULATION NOTES L
1) INTERIOR TO BE %" DRYWALL FINISH.
2) ALL INTERIOR GYPSUM BOARD TO BE MIN.%" THICK WITH (13 GAGE, 1 3/8"'
LONG, 19/64" HEAD, 0.098" DIAMETER,1 '/n" LONG, ANNULAR -RINGED; 5D d
COOLER NAIL, 0.086" DIAMETER, 1 5/8" LONG,15/64" HEAD; OR GYPSUM BOARD
NAIL, 0.086" DIAMETER 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS
AND 12" O.C. FOR SCREWS. 191r '
3) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS
MAT GYPSUM BACKERS INCOMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR vcLmiW
C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS'
L TILE IN TUB AND SHOWER ' G
RECOMMENDATIONS BACKERS FOR WALL E
RECOM I vJ
AREAS AND WALL PANELS IN SHOWER AREAS. (PER FRC 702.4.1 & FRC 702.4.2). 3 1
4) WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF
NOT GREATER THAN 450.�.
5) WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD
CLASSIFICATION OF NOT GREATER THAN 200. �^ �' -ON
6) ALL EXPOSED INSULATION MATERIALS INSTALLED ON ATTIC FLOORS SHALL —Tim-
HAVE A CRITICAL RADIANT FLUX NOT LESS THAN 0.12 WATT PER SQUARE
CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED TO
THE UNDERSIDE OF THE ROOF DEC OR THE ATTIC WALLS SHALL
7 PER FRC 702.2.1 ALL GYPSUM BOARD MAT
COMPLY WITH SECTION FRC316: ' v'�' tom,-
M--rrrt.
ERIALS AND ACCESSORIES SHALL
CONFORM TO ASTM C 36, C 79, C 475, C 514, C 630, C 931, C 960, C 1002, C 1047, C
1177, C 1178, C 1278, C 1395, C 1396 OR C 1658 AND SHALL BE INSTALLED IN
ACCORDANCE WITH THE PROVISIONS OF FRC, AND ADHESIVES FOR THE
INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557 LIN
8)INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERSI
OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING
ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL
SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 BIILTT INSUTAi'IQhI
WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450
WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
tea.,.....
PLUMBING NOTES:
1) ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2017-PLUMBING LU
2) DWV PIPING SHALL BE SCHEDULE 40 PVC. /
3) WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L rw TOP PLATE OR lY0 S1W
COPPER, CPVC, OR PER t METAL RUNNER Ate= WL j
4) SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND
WITHIN BLDG.
J 4?_
5) HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF R-3 SHALL
BE APPLIED TO PIPING LARGER THAN'/." NOMINAL DIAMETER, PIPING FROM i 2°7G4' WOOD FRAMING16A Q.0 y
WATER HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE DR 1'h' X3 S/r METAL STUDS
CONDITIONED SPACE, PIPING FROM THE WATER HEATER TO THE 'µ AI14 ". }
DISTRIBUTION MANIFOLD, PIPING LOCATED UNDER THE FLOOR SLAB,
BURRIED PIPING, SUPPLY AND RETUN PIPING IN RECIRCULATION SYSTEMS,
PIPING WITH RUN LENGTHS GREATER THAN 20 FEET. N N
E HEATERS INSTALLED SHALL BE IN ACCORDANCE WITH FBC zola � � , �-- a
6 WATER F-
ENERGY CONSERVATION. \ \
w
--- V'DRYWALL BATH SIDES
ELECTRICAL NOTES m�
1) LL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) BATT. PLATE OR S Yx'X3 �2"if4"
AALL EDITION. MEIALRU1 W-/-TAPCONSOR
014
2) RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN 6 ' (off was 0 X-D' A.C. ("d PIAR.S
ONDITIONED SPACES. FOR FLOOR)
3) SMOKE DETECTORS TO BE 110V WI BATTERY BACK UP - ARC
CONDITIONED AND UNCFAULT CIRCUIT 4v z
4) SMOKE DETECTORS TO BE LOCATED AS SHOWN, AND INSIDE AND OUTSIDE OF FLOOR
ALL EXISTING BEDROOM INTERIOR DOORS (NOT SHOWN) IF NOT EXISTING
VERIFY. �, `
5) SMOKE DETECTORS TO BE INTERCONNECTED SO THAT ONE SMOKE
DETECTOR ACTIVATES ALL SMOKE DETECTORS IN THE RESIDENCE -
6) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS
SERVING: FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, -
LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS.
7) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-
VOLT, SINGLE-PHASE 15 AND20 AMP CIRCUITS SREVING: BATHROOMS, TYPXAL rnr =
GARAGES, KITCHENS, ACCESORY BUILDINGS, OUTDOORS, OR WITHIN 72" OF « m. �„
EDGE OF ANY SINK
8) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN 10' OF ALL ��� -- — - -
10 PROVIDE TAMPER RESISTANT RECPT CROOF
E9) EXHAUST FANS TO BE V S PER NEC REQUIREMENT
BEDROOMS.
S.
)
11) TIE ELECTRICAL INTO EXISTING ELECTRICAL SERVICE.
,
i
n
d
tt J
� Y /
\ \
\ /
O1_�b \ /
i
0 o FILE COP`
GYI -...
EVvrJ rur�
G ___ �% - ,/�*= I_�,2" n OOMPLMNtCICj'
ST. L CIE COUNTY
PAUL WELCH INC.
MECHANICAL * ELECTRICAL * CIVIL ENGINEERING
1984 S.W. BILTMORE ST. SUITE# 1 14
✓ PORT SAINT LuCIE, FL 34984
- PHONE
f772) 785.9888 EMAIL
PAUL WELCH P.E. FL. REG. NO. 9945 OM
DEC 0 4 2020