Product Evaluation Report
GULF COAST SUPPLY& MANUFACTURING, LLC
24 Ga. Gu►fLokTm 16" Wide Roof Panel over 15132"Plywood
Florida Product Approval #11651.9 R2
Florida Building Code 2014
Per Rule 61 G20-3
Method: 1 -D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61G20-3.00TQ��E�LANS AND ALL PROPOSED WORK
NON HVHZ ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
-.'iEALCU FASTENERS 01 ATTACHMENTS Product Manufacturer: COMPLY WITH ALL APPLICABLE CODES.
ARE THE RESPONSIOIUTYOFTWE-ulf Coast Supply & Manufacturing, LLC. ""1101"'
CONTRACTOR OF RECORD 14429 SW 2nd Place, Suite G30 ��`pPN,E�''•S'.kCis;
Newberry, FL32669 t-�O�NSF•.'y
*. NO, 7551.9
.Engineer Evaluator:
Dan Kuhn, P.E. #75519
•• STATE OF :Q
Florida Evaluation ANE ID: 10743 ;T�s��OR 10
01VA L VyG�`�
70� G� Validator: ',,,,,,,�,t,•
II l Locke Bowden, P.E. #49704 o,6,13%15
�.LUCIE COLNTY BLZLD +G D -ION 9450 Alysbury Place
.::VIEWED FOR CO L
:VIEWED BY Montgomery, AL 36117
dE Al
i,ANS.kND ER-NUT MIDST BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE. Contents:
Evaluation Report Pages 1 — 5
FILE COPY .,FL#11651.9.R2•JUNE 15,2015
.
. . • ® ® .
.�
FLORIDA000,'N
® . GuIfCdaA
SUPPLY & MANUFACTURING
TIM
24 GA. GULFLDKTM 16" WIDE ROOF PANEL OVER 15/32" PLYWOOD:
FLORIDA PRODUCT APPROVAL NO. 11651.9 R2
TM
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Product Description: GulfLokTM'7/s" Nailstrip Roof Panel, Minimum 24 Ga. Steel, Maximum 16"
Coverage, Roof panel restrained with fasteners into minimum 15/32" plywood
decking. Non Structural application.
Panel Material/Standards: Material: Minimum 24 Ga. Steel,ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2014 Section 1507.4.3.
Paint Finish Optional
Yield Strength: 50.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.0235" Minimum
Width: 16 Coverage Maximum
Female Rib: 7/a" Tall
Male Rib: 3/a" Tall Rib with Slotted Strip
Panel,Seam: Snap Lock
Panel Clip: 24 Ga.Zinc Aluminum Coated Steel, 24" Long. Used at Corner Zones only,
where required design pressures exceed-121.75 psf.
Panel Fastener: Through Panel Slot: (1)#10-12xl" Pancake Type A
1/a" Minimum Penetration through Plywood.
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4
Substrate Description: Minimum 15/32" thick,APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this evaluation.
Must be designed in accordance w/Florida Building Code 2014.
Design Uplift Pressures:
Table"A" Maximum Design Pressures
Roof 4reas Assembly, Assembly B /ass_embly C Assembly D
.Maximum Design Pressures 81.75 psf 96.75 psf -121.75 psf -161 psf
Fa Meer Sp cng
Sealant No No Yes No
<Fal flip Nb NjoNo Yes
*Design Pressure includes a Safety Factor=2.0.
FL#11651.9 R2•JUNE 15,2015
EVALUATIONPRODUCT REPORT
FLORIDA PRODUCT APPROVAL G ull "Cozi\�t
SUPPLY & MANUFACTURING
TM
QUIPLOK
24 GA. GULFLOKTM 16"WME ROOF PANEL OVER 15/32" PLYWOOD
FLORIDA PRODUCT APPROVAL NO. 11651.9 R2
TM
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06-Test for Uplift Resistance of Roof Assemblies
• UL 1897-04- Uplift Test for Roof Covering Systems.
Reference Data: 1. UL 580-94/ 1897-98 Uplift Test
Force Engineering &Testing, Inc. (FBC Organization #TST-5328)
Report No. 117-0089T-05 Dated 06/2005
2. UL 580-94/ 1897-98 Uplift Test
Force Engineering &Testing, Inc. (FBC Organization #TST 5328)
Report No. 117-0301T-10A-C, Dated 07/26/2013
3. TAS 125
Architectural Testing, Inc. (FBC Organization#TST-1527)
Report No. B9000.01-450-18, Dated 12/12/2012
4. Certificate of Independence
By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC
(FBC Organization #ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test
standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61 G20-3.005(3)for
manufacturing under a quality assurance program audited by an approved quality
assurance entity.
FL#11651.9 R2•JUNE 15,2015
EVALUATIONPRODUCT REPORT
116 1 B •LANE,BOCA RATON., j °' - FL COA#30464
/ \I
ORIDA kODUCTAPPROVALGulfco6ft
SUPPLY & MANUFACTURING
24 GA. ® !E; ROOF PA NELOVER • •
FLORIDA PRODUCT APPROVAL NO. 11651.9 R2
TM
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including
Section 1507.4.2 and in accordance with Manufacturers recommendations.
Installation: Install per Manufacturer's recommended details.
Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs outside
the parameters listed on the load table, design wind loads shall be determined
for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10
using allowable stress design. The maximum fastener spacing listed herein shall
not be exceeded.This evaluation report is not applicable in High Velocity
Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this
product in High Velocity Hurricane Zone.
FL#11651.9 R2•1UNE 15,2015
PRODUCT EVALUATION
. REPORT
11610 P i• ' ' • . • • . i e e
t000I
Gulfc&M
SUPPLY & MANUFACTURING
FLORIDA PRODUCT APJ PJ RNINA-1 A N, O. 11651.9 R2
TM
ENGINEER LOAD TABLE:24 Ga. GulfLokTM 16"Wide Roof Panel over 15/32" Plywood
Buiciing5 aging a Roof Mean Heights 20'-0"; Roof Slope: 2" 12 - 12 /1. " Viable oa Hip Roof;Wind Speeds 120-
1SOrnph, Exposure C,�Risk ategay II, Enclosed Building, based on Florida Building Code 2014.
120 130 140 150 160 170 180
WIIND FASTENER SUBSTRATE
Penetration)(MIN. do (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER
n) SPACING SPACING SPACING SPACING SPACING SPACING SPACING
4f1 4
CDX
�ZO£NE1 x r
)#1'0-12x1" PLYWOOD ASSEMBLY A ASSEMBLY A ASSEMBLY A SSEMBLY/a ASSEMBLY A ASSEMBLY A ASSEMBLY A
ZONE 2 (1)#10-12x1" PLYWOOD ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A
r
Z(9NE 3 (t1�)#10-12x1'• "PLYWOOD
ASSEMBLY A ASSEMBLY MIMI ASSEMBLY B SSEMBLY B ASSEMBLY C
x:., , .
1.)PANEL DESCRIPTION:GULFLOKTM,MIN.24 GA,7/8" RIB, 16" MAXIMUM COVERAGE,SNAP SEAM.
2.)PANEL FASTENER:(1)#10-12X1" PANCAKE TYPE A, 1A" MIN. PENETRATION THROUGH PLYWOOD.
3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:81.75 PSF AT 101/4" O.C.ASSEMBLY A,96.75 PSF AT 5�/e"O.C.ASSEMBLY B,
-121.75 PSF AT 51/8"O.C.WITH SEALANT ASSEMBLY C,-161 PSF AT 51/a"O.C.WITH CLIP ASSEMBLY D. PRESSURE BASED ON UL 580/UL
1897 TESTING BY FORCE ENGINEERING&TESTING.
4.)PLYWOOD DECKING:MIN.15/32"THICK,APA RATED PLYWOOD,GRADE C-D. MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA
BUILDING CODE,2014.
5.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE 2014
zONE2 11IPROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or
ZONE 3 n 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be
---------• a
`� -------- � less than either 4%of the minimum width of the building or 3 feet.
RIDGE /' ,�/I ASSEMBLYA/B
\ \ /
\� \---------- I
` I 16 COVERAGE
ZONE Jt�-\\\\\
/ \
(1)#10-12 X 1"TYPE A PANCAKE
SAVE SPACING:SEE UPLIFT TABLE
ZONE 2 GABLE ROOF ASSEMBLY C
—J— ----------------- ta
—1/4"-5/16°DIAMETER BEAD OFTITEBOND SEALANT
I I
I 1
RIDGE (1)#10-12 X 1"TYPE A PANCAKE
___ __ ____________! a SPACING:SEE UPLIFT TABLE
14----------------------4 _ka
I ASSEMBLY D W/CLIP
ZONE 1
GulfLok'"CLIP 24 GA.
I 1
-}'----------------------I-
ZONE 3 �EAVE (1)#10-1 2 X V TYPE A PANCAKE
SPACING:SEE UPLIFT TABLE
FL#11651.9 R2•JUNE 15,2015
PRODUCTEVALUATION REPORT
111670 BOCA.RATON, 33498 FL,COA14.4