Loading...
HomeMy WebLinkAboutProduct Approval; Metal RoofingFlorida Building Code Online Page 1 of 3 ProfessionalRegulation KIS Home Log to User Registration Hot Topics ! submit Surcharge Stats & Facts Publlmt Ores C011tact Us 3CJS Site Map Links Search 3 Product Approval b- USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL20484-Rl Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer UNION CORRUGATING COMPANY Address/Phone/Email 701 S. KING ST. FAYETTEVILLE, INC 28301 (910) 483-0479 Ext 256 jstieby@ union corrugating. com Authorized Signature John Stieby jstieby@unioncorrugating.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Bala Sockalingam the Evaluation Report Florida License PE-62240 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 09/07/2027 Validated By Yoosef Lavi, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL20464 R1 COI Certificatelndependence.pdf Standard FM 4470 TAS 125 UL 1897 UL 580 Year 2012 2003 2012 2006 https://www.floridabuilding.org/pr/pr app_dti.aspx?param—wGEVXQwtDgsJ9a49YAgXJ... 12/3/2019 Florida Building Code Online Page 2 of 3 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 08/23/2017 08/28/2017 09/01/2017 12/12/2017 FL # I Model, Number or Name I Description I Z0484.1 5V Min 26 ga., 24" wide through fastened panel over 15/32" thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 R1 11 Ev_aluationReportC2175 1.1)df Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-169 Evaluation Reports Other: Uplift load of 71.0 psf @ fastener spacing of 24" o.c. FL20484 R1 AE Evaluation Re ortC2175 1, df & 169.0 psf @ fastener spacing of 6" o.c. Created by Independent Third Party: Yes 20484.2 Advantage-Lok I1 Min 26 ga., 16" wide concealed fastened panel over 7/16" thick OSB & 15/32" & thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 R1 II EvaluationRe ortC2175 2. df Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam P.E. 62240 Impact Resistant; N/A Created by independent Third Party: Yes Design Pressure: +N/A/-116 Evaluation Reports Other: Maximum uplift load of 116.0 psf @ seam fastener FL20484 R1 AF FvaivatianReportC2175, 2.pdf spacing of 4-5/8" ox. along seam into min. 15/32" thick APA Created by Independent Third Party: Yes rated plywood with retainer strap. 20484.3 7deck Aluminum Advantage-Lok II Max 16.375" wide, nom 0.032" thick (min.) aluminum concealed fastener roof panel over min 15/32" thick plywood or 7/16" thick OSB. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 R1 I1 EvaluationReoortC2175 3.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam P.E. 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-93.5 Evaluation Reports Other: Uplift load of 22.5 psf at fastener spacing of 18.5" FL20484 R1 AE Evaluation ReoortC2175 3.pdf o.c. and 86.0 psf at fastener spacing of 4.63" o.c. in 15/32" Created by Independent Third Party: Yes plywood or 7/16" OSB. Uplift load of 93.5 psf at fastener spacing of 4.63" o.c. with structural sealant in 15/32" plywood. 20484.4 Aluminum SL150 Max 16" wide, nom 0.032" thick (min.) aluminum snap -lock standing seam metal panel over min 15/32" thick plywood deck or 7/16" thick OSB Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 R1 II EvatuationReportC2175 4.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam P.E. 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-86 Evaluation Reports Other: Uplift load of 45.0 psf at clip spacing of 24" o.c. and FL20484 kl AE EvaluationReoortC2175 4.odf 78.5 psf at clip spacing of 6" o.c. in 15/32" plywood or 7/16" Created by Independent Third Party: Yes OSB. Uplift load of 86.0 psf at clip spacing of 6" o.c. with structural sealant in 15/32" plywood. 20484.5 MasterRib Min 29 ga., 36" wide through fastened panel over 15132" thick plywood or 7/16" thick OSB Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 R1 II EvaluatlonReoortC2175 5.odf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-124 Evaluation Reports Other: Uplift load of 56.0 psf @ fastener spacing of 24" o.c. FLL2 4$4_ R1 AE EvaivationRenortC2175 5.ndf & 124.0 psf @ fastener spacing of 6" o.c. Created by Independent Third Party: Yes 20484.6 MasterRib Min 29 ga., 36" wide through fastened panel over 15/32" thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484_ R1 Il EvaluatlonRenorl:Q 175 6.ndf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-88.5 Evaluation Reports Other: Uplift load of 56 psf for Fastening System 1. Uplift FL20434 R1 AE EvaluationReoortC2175 6.pdf load of 88.5 psf for Fastening System 2. Created by Independent Third Party: Yes https:ll*ww.floridabuilding.orglprlpr_app dtl.aspx?param=wGEVXQWtDgsj9a49YAgXJ... 12/3/2019 Florida Building Code Online Page 3 of 3 20484.7 ML150 I Max 16.5" wide, min 24 ga. steel standing seam panel over 15/32" thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL204i5A R1 II Eva ugtionRe o 2 7.Lidf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 62240 Impact Resistant: N/A Created by rndependent Third Party: Yes Design Pressure: +N/A/-124 Evaluation Reports Other: Maximum uplift load or 124 psf @ clip spacing of 6" FL20484 R1 AE Evaluation ReportC,'„2175_7_odf o.c. with 180 seam, self -adhering membrane and fixed clip. Created by Independent Third Party: Yes 20484.8 PBR or R Panel Min 26 ga., 36" wide through fastened panel over 15/32" thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 RI II Evaluation Re ortC2175 8. df Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam P.E. 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-161.5 Evaluation Reports Other: Uplift load of 30.0 psf at fastener spacing of 48" o.c. FL20484 RI AE EvaluationReoortC2175 8,pdf and 161.5 psf at fastener spacing of 6" o.c. Created by Independent Third Party: Yes 20484.9 SL175 Max 18" wide, min 24 ga., snap -lock standing seam metal panel over 15/32" thick plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL20484 R1 fi EyaluationRepprtC2175 9.pdf Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam, P.E. 62240 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-93.5 Evaluation Reports Other: Uplift load of 39.8 psf @ clip spacing of 36" o.c. and FL20484 R1 AE Evaluation Re ortC2175 9. df 78.6 psf @ clip spacing of 8" o.c with felt. Uplift load of 93.5 Created by Independent Third Party: Yes psf @ clip spacing of 12" o.c. with self -adhering membrane. back Next Contact Us :: 260E Blair Stone Road Tallahassee FL 3 399 Phone: $50-487-1824 The State of Fiorida is an AAIFFO employer, Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public-rewrtis request, do not send electmNc mail t0 this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official comm uniration with the licensee. However email addresses are pubfic record. If you do not wish to supply a personal address, please provide the Department with an emal I address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click hem . Product Approval Accepts: ® !Check Credit Card Safe https://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJ... 12/3/2019 EVALUATION REPORT OF UNION CORRUGATING COMPANY `26 GA. ADVANTAGE-LOK 11' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 20484.2-R1 ROOFING METAL ROOFING Prepared For: Union Corrugating Company 701 S. King St. Fayetteville, NC 28301 Telephone: (910) 483-0479 Fax: (910) 483-1091 Prepared By: Bala Sockaliungam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (I Page) Report No. C2175-2 Date: 8.23.2017 FL 20484.2-R1 C2175-2 8.23.2017 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: Advantage-Lok 11 Panel Panel Description: Max. 16" wide coverage with 1" high ribs Materials: Minimum 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 7/16" thick OSB or min. 15/32" thick APA rated plywood or min. 3/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017_ New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction. Existing Underlayment: One layer of asphalt shingles over one layer of 430 felt. For reroofing (Optional) construction only. Slope: 2:12 or greater in accordance with FBC 2017 Section 1507.4.2 Design Uplift Pressure: 30.0 psf @ panel fastener spacing of 13-7/8" o.c. along seam (Factor of Safety = 2) 63.5 psf @ panel fastener spacing of 9-1/4" o.c. along seam 78.5 psf @ panel fastener spacing of 4-5/8" o.c. along seam 112.5 psf @ scam fastener spacing of 4-5/8" o.c. along seam with 3/16" diameter bead sealant in panel seam 116.0 psf @ scam fastener spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA rated plywood with retainer strap Panel Attachment: # 10-12 pancake head wood screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". Retainer Strap: 5" wide, 24 ga., 50 ksi strap fastened to deck with 2 rows of #10-12 x 1" long pancake head screws at 12" o.c. spacing and 6" staggered. The strap is continuous over the entire corner or edge roof zones. Prior to the panel installation, two rows of 3/8" bead of adhesive are field applied along the length of the strap. Seam Sealant: Sikaflex-201 or APS 500 Advance Polymer Sealant. In lieu of Sikaflex or APS sealant, adhesive/sealant with greater or equal tensile properties may be used. Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL 1897-04 `Uplift Tests for Roof Covering FL 20484.2-R1 C2175-2 8.23.2017 Page 3 of 3 Systems' or TAS 1.25-03 `Standard Requirements for Metal Roofing Systems'. Test Equivalency: The test procedures in UL 1897-04 comply with test procedures prescribed in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E 108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580 & UL1897 Test Reports PRI Construction Materials Technologies UCC-006-02-1 Rev 1, Reporting Date 2/10/12 TAS 125 Test Report Farabaugh Engineering and Testing Inc. Project No. T302-16, Reporting Date 11/16/16, Revised Date 1/18/17 Project No. T303-16, Reporting Date 11/16/16, Revised Date 1/18/17 Project No. T304-16, Reporting Date 11/16/16, Revised Date 1/18/17 z z Ox m ax m m N N Z � � K D m ? -u r Z z Y Z m r m r r IfI 10 i D F W O (/) F— I I N e Om po c C7 mp apo ➢N �U' p n' V Mn as Z n Z n Z -vO was, MO ry m r n X m r o� �z a W z Nn vV) Z Uf nz nz � v dl 01 A 4A N m Zlm m3Li:U� -O �]'a LJ afJr�Z(/7. jf�i furl OOn CCp�p'DC =tom ZaQZ TI�77Zy�az—o,-�-nn� Z ozor mllM co O O QO ��c�il��a{�zno,uriaa \O UI��Z�fTr3 A�;L7 T m 2 cm: m ce V)nO c-i -=1>-zp� io-`1 M'mQ� jp� �ulQ-;Tm� m ����ZSDd�Im1 fm'1wr z nn mn to am mp-i_p ➢ O Z �O pmlzr r A W r r ppmnzD�co O m z mOO-mOm'm O m O yrnQ ➢pp m n � zQrlm-amg"� z -M -r M Fq z ;u8=-M"T'K o Q N� Z'a-1m CZ,m 2 �T`C]ZD Y m Z vzi O Oa .�z�rm � cg-i O Z r r � p C m ODo n Np C `c ��0 o z a i na m in Q a 4+ 41 W O i➢n :i czi�m M2Z c rn m rn W Z 0 QQ A y O m D m m m rn o� z O z.z O O z m a z z m z rn z m � mz m-4 m p z z z z � cn� C 0 0 0 0 La Z O Z Z Z Z -um z � m cn Ln o rn c m J D 1 J ONzlt AOVANTAGELOK 11 PANEL Y � CUN5uCTANTS IWNUFACTURER o z cs z BALA SOCKAUNGAM. PH.D., P.E. UNION CORRUGATING CO. 1210 N WISING 74 ASURE C 701 S. KING STREET f Tub o>< Tc1na FAYETTEViLLE, NC 2$301 PH R 918-492-5992 FAX: 565-M6 1543 910-483-2195 m m c p z - y O - o N O A N O� C Z a z 0 n R' O X -o � 6 zz a Tr a I Z z o M I < M c m 1n�n m =za m� o �q z O'K L7 �m � z x 5,'m> r u